13 resultados para 153-924
em Instituto Politécnico do Porto, Portugal
Resumo:
In health care there has been a growing interest and investment in new tools to have a constant monitoring of patients. The increasing of average life ex-pectation and, consequently, the costs in health care due to elderly population are the motivation for this investment. However, healthmonitoring is not only important to elderly people, it can be also applied to people with cognitive disabilities. In this article we present some systems, which try to support these persons on doing their day-to-day activities and how it can improve their life quality. Also, we present an idea to a project that tries to help the persons with cognitive disabilities by providing assistance in geo-guidance and keep their caregivers aware of their location.
Resumo:
É objectivo deste trabalho caracterizar biomecanicamente o gesto de alcançar em indivíduos pós Acidente Vascular Encefálico. A amostra é constituída por 4 indivíduos sem patologia do foro neuro-músculo-esquelético e 4 indivíduos com confirmação imagiológica do diagnóstico de AVE único e unilateral no território da artéria cerebral média, há pelo menos 3 meses; ausência de neglet; ausência de alterações visuais, perceptivas ou cognitivas e capacidade de realizar movimento activo no membro superior predominantemente afectado de pelo menos 15º no ombro e cotovelo. A partir de uma posição de sentado pré-definida, cada indivíduo foi instruído a executar a tarefa funcional de alcançar um alvo (copo com sumo), colocado sobre uma mesa, no limite anatómico da distância de alcance funcional da mão. Para a análise cinemática foram usadas 4 câmaras dispostas duas a duas para avaliação do movimento de cada um dos membros superiores. Foram colocados marcadores reflectores nas seguintes estruturas ósseas: esterno; acrómio (bilateralmente); epicôndilo lateral; processo estilóide do cúbito, 3º metacarpo e grande trocânter. Foi também colocado um marcador no objecto-alvo. Recorreu-se ao software APAS para análise das seguintes variáveis cinemáticas: tempo de execução do movimento, velocidade máxima da mão, unidades de movimento, trajectória (através do índex de curvatura) e extensão do cotovelo. Verificou-se que no grupo de indivíduos com AVE comparativamente ao grupo de indivíduos sem patologia, o tempo de execução do movimento foi superior (5,8±2,48 e 0,9±0,22 respectivamente), a velocidade máxima da mão foi inferior (101,7±32,62 e 153,3±56,32 respectivamente), o número de unidades de movimento foi superior (6,3±1,50 e 2,5±0,58 respectivamente), o índex de curvatura foi superior (1,8±0,54 e 1,2±0,1 respectivamente) e a amplitude de extensão do cotovelo foi inferior (15,3±16,48 e 50,2±6,72 respectivamente). Os indivíduos com AVE apresentam alterações nos parâmetros cinemáticos analisados, quando comparados com indivíduos sem patologia.
Resumo:
Mestrado em Engenharia Química
Resumo:
O objectivo desta tese é dimensionar um secador em leito fluidizado para secagem de cereais, nomeadamente, secagem de sementes de trigo. Inicialmente determinaram-se as condições de hidrodinâmica (velocidade de fluidização, TDH, condições mínimas de “slugging”, expansão do leito, dimensionamento do distribuidor e queda de pressão). Com as condições de hidrodinâmica definidas, foi possível estimar as dimensões físicas do secador. Neste ponto, foram realizados estudos relativamente à cinética da secagem e à própria secagem. Foi também estudado o transporte pneumático das sementes. Deste modo, determinaram-se as velocidades necessárias ao transporte pneumático e respectivas quedas de pressão. Por fim, foi realizada uma análise custos para que se soubesse o custo deste sistema de secagem. O estudo da secagem foi feito para uma temperatura de operação de 50ºC, tendo a ressalva que no limite se poderia trabalhar com 60ºC. A velocidade de operação é de 2,43 m/s, a altura do leito fixo é de 0,4 m, a qual sofre uma expansão durante a fluidização, assumindo o valor de 0,79 m. O valor do TDH obtido foi de 1,97 m, que somado à expansão do leito permite obter uma altura total da coluna de 2,76 m. A altura do leito fixo permite retirar o valor do diâmetro que é de 0,52 m. Verifica-se que a altura do leito expandido é inferior à altura mínima de “slugging” (1,20 m), no entanto, a velocidade de operação é superior à velocidade mínima de “slugging” (1,13 m/s). Como só uma das condições mínimas é cumprida, existe a possibilidade da ocorrência de “slugging”. Finalmente, foi necessário dimensionar o distribuidor, que com o diâmetro de orifício de 3 mm, valor inferior ao da partícula (3,48 mm), permite a distruibuição do fluido de secagem na coluna através dos seus 3061 orifícios. O inicio do estudo da secagem centrou-se na determinação do tempo de secagem. Além das duas temperaturas atrás referidas, foram igualmente consideradas duas humidades iniciais para os cereais (21,33% e 18,91%). Temperaturas superiores traduzem-se em tempos de secagem inferiores, paralelamente, teores de humidade inicial inferiores indicam tempos menores. Para a temperatura de 50ºC, os tempos de secagem assumiram os valores de 2,8 horas para a 21,33% de humidade e 2,7 horas para 18,91% de humidade. Foram também tidas em conta três alturas do ano para a captação do ar de secagem, Verão e Inverno representando os extremos, e a Meia- Estação. Para estes três casos, foi possível verificar que a humidade específica do ar não apresenta alterações significativas entre a entrada no secador e a corrente de saída do mesmo equipamento, do mesmo modo que a temperatura de saída pouco difere da de entrada. Este desvio de cerca de 1% para as humidades e para as temperaturas é explicado pela ausência de humidade externa nas sementes e na pouca quantidade de humidade interna. Desta forma, estes desvios de 1% permitem a utilização de uma razão de reciclagem na ordem dos 100% sem que o comportamento da secagem se altere significativamente. O uso de 100% de reciclagem permite uma poupança energética de cerca de 98% no Inverno e na Meia-Estação e de cerca de 93% no Verão. Caso não fosse realizada reciclagem, seria necessário fornecer à corrente de ar cerca de 18,81 kW para elevar a sua temperatura de 20ºC para 50ºC (Meia-Estação), cerca de 24,67 kW para elevar a sua temperatura de 10ºC para 50ºC (Inverno) e na ordem dos 8,90 kW para elevar a sua temperatura dos 35ºC para 50ºC (Verão). No caso do transporte pneumático, existem duas linhas, uma horizontal e uma vertical, logo foi necessário estimar o valor da velocidade das partículas para estes dois casos. Na linha vertical, a velocidade da partícula é cerca de 25,03 m/s e cerca de 35,95 m/s na linha horizontal. O menor valor para a linha vertical prende-se com o facto de nesta zona ter que se vencer a força gravítica. Em ambos os circuitos a velocidade do fluido é cerca de 47,17 m/s. No interior da coluna, a velocidade do fluido tem o valor de 10,90 m/s e a velocidade das partículas é de 1,04 m/s. A queda de pressão total no sistema é cerca de 2408 Pa. A análise de custos ao sistema de secagem indicou que este sistema irá acarretar um custo total (fabrico mais transporte) de cerca de 153035€. Este sistema necessita de electricidade para funcionar, e esta irá acarretar um custo anual de cerca de 7951,4€. Embora este sistema de secagem apresente a possibilidade de se realizar uma razão de reciclagem na ordem dos 100% e também seja possível adaptar o mesmo para diferentes tipos de cereais, e até outros tipos de materiais, desde que possam ser fluidizados, o seu custo impede que a realização deste investimento não seja atractiva, especialmente tendo em consideração que se trata de uma instalação à escala piloto com uma capacidade de 45 kgs.
Resumo:
The goal of this work was the treatment of polluted waste gases in a bubble column reactor (BCR), in order to determinate the maximum value of reactor’s efficiency (RE), varying the inlet concentration (C in) of the pollutants. The gaseous mixtures studied were: (i) air with styrene and (ii) air with styrene and acetone. The liquid phase used to contain the biomass in the reactor was a basal salt medium (BSM), fundamental for the microorganisms’ development. The reactor used in this project consists of a glass column of 620mm height and inside diameter 75mm. In all essays there were continually measured: pH, dissolved oxygen and liquid’s temperature. Temperature and pH were controlled (T=24ºC, 7.0 ≤ pH ≤ 7.7). In all experiments the liquid volume (including the biomass) used in the reactor was kept constant (1.5L) as well as the total gas flowrate (1 L/min). Concerning the goal of the work, some parameters were calculated: the organic load (OL), removal efficiency (RE), elimination capacity (EC), biomass concentration (xf) and dry biomass concentration (Xdw). In a first series of experiments, the gas mixture used was air with styrene, varying its concentration from 191 mg.m-3 to 6500 mg.m-3.It was concluded that the RE maximum value (97%) was obtained for C in Sty = 4200 mg.m-3. For the maximum tested value of C in Sty, RE obtained was 20%. In a second step, the gaseous mixture included acetone, varying C in Sty between 225 mg.m-3 and 2659 mg.m-3 and C in Ac between 153mg.m-3 and 1389 mg.m-3. The aim of these tests was the determination of C in Ac for which RE was maximum, obtaining C in Ac = 750 mg.m-3. A third series of experiments was performed, in which C in Ac was maintained equal to that value and C in Sty was varied until higher values (5422 mg.m-3). RE maximum values obtained in this last series were 100% for styrene and 40% for acetone. One important conclusion is the fact that the microorganisms available degrade better styrene than acetone. On the ambit of this study, it was possible to identify the species available in biomass: Xanthobacter antotrophicus py2, Enterobacter aerogenes, Nocardia, Corynebacterium Spp., Rhodococcus rhodochrous e Pseudomonas Sp.
Resumo:
Specific marine macro algae species abundant at the Portuguese coast (Laminaria hyperborea, Bifurcaria bifurcata, Sargassum muticum and Fucus spiralis) were shown to be effective for removing toxic metals (Cd(II), Zn(II) and Pb(II)) from aqueous solutions. The initial metal concentrations in solution were about 75–100 mg L−1. The observed biosorption capacities for cadmium, zinc and lead ions were in the ranges of 23.9–39.5, 18.6–32.0 and 32.3–50.4 mg g−1, respectively. Kinetic studies revealed that the metal uptake rate was rather fast, with 75% of the total amount occurring in the first 10 min for all algal species. Experimental data were well fitted by a pseudo-second order rate equation. The contribution of internal diffusion mechanism was significant only to the initial biosorption stage. Results indicate that all the studied macro algae species can provide an efficient and cost-effective technology for eliminating heavy metals from industrial effluents.
Resumo:
Dissertação de Mestrado apresentada ao Instituto Superior de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Marketing Digital, sob orientação de Mestre Maria Antónia Rodrigues Ferreira
Resumo:
A presente dissertação insere-se no âmbito da unidade curricular de “Dissertação/Projeto/Estágio”, do 2º ano do mestrado em Engenharia Eletrotécnica – Sistemas Elétricos de Energia. Com o crescente aumento do consumo energético a nível mundial, e consequente esgotamento dos recursos fósseis, surge a necessidade de procurar soluções alternativas para a produção de energia. As energias renováveis aparecem como uma solução sustentável na produção de eletricidade, pois a sua produção representa um menor custo. Este trabalho tem como principais objetivos o dimensionamento de uma central de produção fotovoltaica para o ISEP nos regimes de exploração em autoconsumo e pequena produção, tendo em conta o atual Decreto-Lei (DL) n.º 153/2014, e também a análise de viabilidade económica dessa mesma instalação. O sistema fotovoltaico usado no dimensionamento em autoconsumo e pequena produção foi realizado com recurso ao software PVsyst. Tendo em conta que os consumos do ISEP são bastante inferiores nos períodos de férias escolares e fins-de-semana, e também por haver uma limitação de área disponível para a colocação dos módulos fotovoltaicos, a melhor opção a adotar será um sistema fotovoltaico de 237 kWp, tanto para autoconsumo como para pequena produção. Outro objetivo é a realização de um estudo de viabilidade económica do sistema fotovoltaico dimensionado. Os resultados obtidos permitem então clarificar qual dos regimes de exploração é mais viável para o ISEP, sendo que esses resultados poderão servir de apoio a uma futura decisão, caso o ISEP decida instalar um sistema deste tipo.
Resumo:
BACKGROUND AND PURPOSE: A single bout of aerobic exercise acutely decreases blood pressure, even in older adults with hypertension. Nonetheless, blood pressure responses to aerobic exercise in very old adults with hypertension have not yet been documented. Therefore, this study aimed to assess the effect of a single session of aerobic exercise on postexercise blood pressure in very old adults with hypertension. METHODS: Eighteen older adults with essential hypertension were randomized into exercise (N = 9, age: 83.4 ± 3.2 years old) or control (N = 9, age: 82.7 ± 2.5 years old) groups. The exercise group performed a session of aerobic exercise constituting 2 periods of 10 minutes of walking at an intensity of 40% to 60% of the heart rate reserve. The control group rested for the same period of time. Anthropometric variables and medication status were evaluated at baseline. Heart rate and systolic and diastolic blood pressures were measured at baseline, after exercise, and at 20 and 40 minutes postexercise. RESULTS: Systolic blood pressure showed a significant interaction for group × time (F3,24 = 6.698; P = .002; ηp = 0.153). In the exercise group, the systolic blood pressure at 20 (127.3 ± 20.9 mm Hg) and 40 minutes (123.7 ± 21.0 mm Hg) postexercise was significantly lower in comparison with baseline (135.6 ± 20.6 mm Hg). Diastolic blood pressure did not change. Heart rate was significantly higher after the exercise session. In the control group, no significant differences were observed. CONCLUSIONS: A single session of aerobic exercise acutely reduces blood pressure in very old adults with hypertension and may be considered an important nonpharmacological strategy to control hypertension in this age group.
Resumo:
Introduction: Lesions at ipsilateral systems related to postural control at ipsilesional side, may justify the lower performance of stroke subjects during walking. Purpose: To analyse bilateral ankle antagonist coactivation during double-support in stroke subjects. Methods: Sixteen (8 females; 8 males) subjects with a first isquemic stroke, and twenty two controls (12 females; 10 males) participated in this study. The double support phase was assessed through ground reaction forces and electromyography of ankle muscles was assessed in both limbs. Results: Ipsilesional limb presented statistical significant differences from control when assuming specific roles during double support, being the tibialis anterior and soleus pair the one in which this atypical behavior was more pronounced. Conclusion: The ipsilesional limb presents a dysfunctional behavior when a higher postural control activity was demanded.
Resumo:
Nos últimos anos o consumo de energia elétrica produzida a partir de fontes renováveis tem aumentado significativamente. Este aumento deve-se ao impacto ambiental que recursos como o petróleo, gás, urânio, carvão, entre outros, têm no meio ambiente e que são notáveis no diaa- dia com as alterações climáticas e o aquecimento global. Por sua vez, estes recursos têm um ciclo de vida limitado e a dada altura tornar-se-ão escassos. A preocupação de uma melhoria contínua na redução dos impactos ambientais levou à criação de Normas para uma gestão mais eficiente e sustentável do consumo de energia nos edifícios. Parte da eletricidade vendida pelas empresas de comercialização é produzida através de fontes renováveis, e com a recente publicação do Decreto de Lei nº 153/2014 de 20 outubro de 2014 que regulamenta o autoconsumo, permitindo que também os consumidores possam produzir a sua própria energia nas suas residências para reduzir os custos com a compra de eletricidade. Neste contexto surgiram os edifícios inteligentes. Por edifícios inteligentes entende-se que são edifícios construídos com materiais que os tornam mais eficientes, possuem iluminação e equipamentos elétricos mais eficientes, e têm sistemas de produção de energia que permitem alimentar o próprio edifício, para um consumo mais sustentado. Os sistemas implementados nos edifícios inteligentes visam a monitorização e gestão da energia consumida e produzida para evitar desperdícios de consumo. O trabalho desenvolvido visa o estudo e a implementação de Redes Neuronais Artificiais (RNA) para prever os consumos de energia elétrica dos edifícios N e I do ISEP/GECAD, bem como a previsão da produção dos seus painéis fotovoltáicos. O estudo feito aos dados de consumo permitiu identificar perfis típicos de consumo ao longo de uma semana e de que forma são influenciados pelo contexto, nomeadamente, com os dias da semana versus fim-de-semana, e com as estações do ano, sendo analisados perfis de consumo de inverno e verão. A produção de energia através de painéis fotovoltaicos foi também analisada para perceber se a produção atual é suficiente para satisfazer as necessidades de consumo dos edifícios. Também foi analisada a possibilidade da produção satisfazer parcialmente as necessidades de consumos específicos, por exemplo, da iluminação dos edifícios, dos seus sistemas de ar condicionado ou dos equipamentos usados.
Resumo:
Nos últimos anos, tem-se assistido a uma maior preocupação com o meio ambiente, a atual conjuntura mundial está cada vez mais direcionada para a eficiência energética e para a utilização de fontes de energias renováveis. Os principais governos mundiais, incluindo o português, já perceberam a necessidade de enveredar por esse caminho e nesse sentido aplicam medidas que direcionam e consciencializam a população para a eficiência energética e para as energias renováveis. Em Portugal, o setor das energias renováveis assume atualmente uma posição de extrema importância, resultante da expressão que governo português tem vindo a implementar no panorama energético nacional, da qual resulta uma importante contribuição para o desenvolvimento económico, na criação de riqueza e geração de emprego. Neste contexto, e no caso particular da energia fotovoltaica têm sido implementadas medidas que incentivam a aposta nesta tecnologia, prova disso é o Decreto-Lei n.º 153/2014 aprovado em conselho de ministros em Setembro de 2014, que promove essencialmente o autoconsumo. O autoconsumo consiste na utilização de painéis fotovoltaicos para produção de energia elétrica para consumo próprio com ou sem recurso a equipamentos de acumulação. Em termos práticos, este sistema permite que os consumidores produzam a sua própria energia através de uma fonte renovável ao invés de adquirir essa energia na rede elétrica de serviço público. As políticas de incentivo ao autoconsumo proporcionam uma oportunidade para os consumidores interessados em investir na produção da própria energia elétrica, neste sentido e de forma a ajudar no dimensionamento de unidades de produção de autoconsumo foi desenvolvida, no âmbito desta tese, uma ferramenta de apoio ao dimensionamento de sistemas de autoconsumo fotovoltaico sem acumulação em ambiente doméstico, com o objetivo de estimar as necessidades de potência fotovoltaica a instalar em habitações de baixa tensão normal. Na base da construção desta ferramenta estiveram essencialmente os perfis de consumo, aprovados pela Entidade Reguladora dos Serviços Energéticos, de todos os clientes finais que não dispõem de equipamento de medição com registo de consumos e também a estimativa de produção fotovoltaica desenvolvida pelo Centro Comum de Investigação da Comissão Europeia. A aplicação desenvolvida tem como principal funcionalidade proporcionar ao utilizador o dimensionamento de unidades de produção de autoconsumo fotovoltaico, mediante a introdução de alguns dados tais como o distrito, a potência contratada, a tarifa e o consumo energético anual. Esta aplicação apresenta resultados relativos ao dimensionamento do sistema, como é o caso da potência a instalar e da estimativa de produção fotovoltaica anual, e resultados relativos à análise económica do sistema como é o caso do valor atual líquido, da taxa interna de rentabilidade e do payback do investimento.