112 resultados para electrochemical detection
Resumo:
In this paper we present a set of field tests for detection of human in the water with an unmanned surface vehicle using infrared and color cameras. These experiments aimed to contribute in the development of victim target tracking and obstacle avoidance for unmanned surface vehicles operating in marine search and rescue missions. This research is integrated in the work conducted in the European FP7 research project Icarus aiming to develop robotic tools for large scale rescue operations. The tests consisted in the use of the ROAZ unmanned surface vehicle equipped with a precision GPS system for localization and both visible spectrum and IR cameras to detect the target. In the experimental setup, the test human target was deployed in the water wearing a life vest and a diver suit (thus having lower temperature signature in the body except hands and head) and was equipped with a GPS logger. Multiple target approaches were performed in order to test the system with different sun incidence relative angles. The experimental setup, detection method and preliminary results from the field trials performed in the summer of 2013 in Sesimbra, Portugal and in La Spezia, Italy are also presented in this work.
Resumo:
Oceans - San Diego, 2013
Resumo:
A furazolidona é uma substância ativa do medicamento Giarlam que contém um espetro anti-bacteriano relativamente amplo e que é frequentemente usado para tratar certas doenças bacterianas e protozoárias no homem. A maioria dos fármacos exige uma dosagem que garanta os níveis de segurança e eficácia de atuação. A necessidade de dosear os medicamentos e os seus metabólitos exige o desenvolvimento constante de métodos analíticos eficientes. Neste trabalho desenvolveu-se um novo sensor eletroquímico para a deteção da furazolidona, baseado num elétrodo de pasta de carbono modificado com um polímero molecularmente impresso. A procura de novos materiais que permitam uma melhor seletividade e sensibilidade aos sistemas de deteção é especialmente importante no desenvolvimento de métodos analíticos. Os polímeros molecularmente impressos enquadram-se nesse perfil e o seu uso tem vindo a ser cada vez mais frequente como ferramenta importante em química analítica. Assim, sintetizou-se um polímero com cavidades seletivas para a Furazolidona. Este polímero foi, misturado com grafite e perafina de modo a produzir uma pasta de carbono. Uma seringa de plástico foi usada como suporte da pasta de carbono. O comportamento eletroquímico do sensor foi avaliado e diversas condições de utilização foram estudadas e otimizadas. O sensor apresenta um comportamento linear entre a intensidade do pico e a concentração numa gama de concentrações entre 1 e 100 μM, um limite de deteção de 1 μM e uma precisão (repetibilidade) inferior a 7%. A aplicabilidade do sensor fabricado em amostras complexas foi avaliada pela deteção do fármaco em amostras de urina.
Resumo:
In the present work, the development of a genosensor for the event-specific detection of MON810 transgenic maize is proposed. Taking advantage of nanostructuration, a cost-effective three dimensional electrode was fabricated and a ternary monolayer containing a dithiol, a monothiol and the thiolated capture probe was optimized to minimize the unspecific signals. A sandwich format assay was selected as a way of precluding inefficient hybridization associated with stable secondary target structures. A comparison between the analytical performance of the Au nanostructured electrodes and commercially available screen-printed electrodes highlighted the superior performance of the nanostructured ones. Finally, the genosensor was effectively applied to detect the transgenic sequence in real samples, showing its potential for future quantitative analysis.
Resumo:
Potentiometric detection with homemade polymeric membrane microelectrodes was coupled to a magnetic sandwich immunoassay for Salmonella typhimurium determination. Cadmium and sodium ion selective electrodes were used respectively as indicator and pseudo-reference electrodes and were prepared in pipette tips to allow potentiometric measurements in microliter sample volumes. In the proposed method, the concentration of S. typhimurium was proportional to the amount of cadmium released upon dissolution of a CdS nanoparticle labeled to the secondary detection antibody. The limit of detection was 2 cells per 100 μL. The immunomagnetic assay with potentiometric detection is suitable for sensitive and rapid (average total time per assay of 75 minutes) detection of S. typhimurium in milk samples. The proposed method is easy to perform, safe, sensitive, and low cost and has potential for in situ analysis.
Resumo:
The purpose of this work was to develop a reliable alternative method for the determination of the dithiocarbamate pesticide mancozeb (MCZ) in formulations. Furthermore, a method for the analysis of MCZ's major degradation product, ethylenethiourea (ETU), was also proposed. Cyclic voltammetry was used to characterize the electrochemical behavior of MCZ and ETU, and square-wave adsorptive stripping voltammetry (SWAdSV) was employed for MCZ quantification in commercial formulations. It was found that both MCZ and ETU are irreversibly reduced (− 0.6 V and − 0.5 V vs Ag/AgCl, respectively) at the surface of a glassy carbon electrode in a mainly diffusion-controlled process, presenting maximum peak current intensities at pH 7.0 (in phosphate buffered saline electrolyte). Several parameters of the SWAdSV technique were optimized and linear relationships between concentration and peak current intensity were established between 10–90 μmol L− 1 and 10–110 μmol L− 1 for MCZ and ETU, respectively. The limits of detection were 7.0 μmol L− 1 for MCZ and 7.8 μmol L− 1 for ETU. The optimized method for MCZ was successfully applied to the quantification of this pesticide in two commercial formulations. The developed procedures provided accurate and precise results and could be interesting alternatives to the established methods for quality control of the studied products, as well as for analysis of MCZ and ETU in environmental samples.
Resumo:
No dia-a-dia, os organismos vivos estão sujeitos a vários tipos de agressões de origem endógena e exógena. A produção endógena exagerada de contaminantes que ocorre nos processos metabólicos dos seres vivos está intimamente associada ao aparecimento e desenvolvimento de várias patologias. Por outro lado, e devido às atividades antropogénicas, muitos contaminantes de origem ambiental e alimentar entram por via exógena no organismo dos seres vivos provocando igualmente danos a nível celular. De modo a protegerem-se dos efeitos pejorativos provocados por estes compostos, os organismos vivos desenvolveram mecanismos complexos de defesa antioxidante. Este trabalho consistiu no estudo eletroquímico do dano oxidativo induzido por contaminantes (PAH (hidrocarbonetos aromáticos policíclicos), H2O2, NO• e HClO) e do efeito protetor, ao dano oxidativo, promovido por antioxidantes no material baseado no ADN recorrendo à utilização de um biossensor de bases púricas, adenina-EPC (elétrodo pasta de carbono) e dA20-EPC, utilizando a voltametria de onda quadrada (VOQ) como técnica de deteção. A aplicação da eletroquímica apresenta várias vantagens para a quantificação da capacidade antioxidante total (CAT) pois, permite a redução da quantidade de reagentes e amostra em análise, elimina a etapa de remoção de cor (a cor é um interferente nos métodos óticos) e não requer equipamentos dispendiosos. Foram seguidas diferentes abordagens para a construção dos biossensores. A primeira consistiu na construção de um adenina-EPC em três etapas: i) condicionamento do EPC, ii) eletrodeposição da adenina no EPC e iii) leitura do sinal eletroquímico. Assim, foram otimizados diversos parâmetros: concentração de adenina (150,0 mg/L), potencial de condicionamento (Ec) (+ 1,80 V), potencial de deposição (Ed) (+ 0,40 V), tempo de condicionamento (tc) (180 s) e tempo de deposição (td) (240 s). Foi aplicado o adenina-EPC no estudo do dano oxidativo provocado por PAH (benzo (g,h,i) perileno) e constatou-se que era necessário transformar o benzo (g,h,i) perileno num radical para se possível observar danos oxidativos induzidos no biossensor. A nova estratégia consistiu na construção de um dA20-EPC, através da adsorção física de uma gota de dA20 na superfície do EPC, com posterior secagem e leitura do sinal eletroquímico. Neste procedimento foi otimizada a concentração de dA20 (100,0 mg/L). O dano oxidativo provocado pelo H2O2, NO• e HClO foi estudado sobre o dA20-EPC e verificou-se que os três contaminantes induziam dano oxidativo no dA20-EPC. Confirmou-se a capacidade do ácido ascórbico (AA) em proteger o dA20-EPC do dano oxidativo induzido por H2O2 e NO•. O biossensor desenvolvido (dA20-EPC) foi aplicado na avaliação da CAT de diferentes amostras reais (café, sumo de laranja e água aromatizada de laranja) usando-se como contaminantes o H2O2 e NO•. Todas as amostras analisadas apresentaram ter capacidade antioxidante. Quando se usou o dA20-EPC na presença de H2O2, verificou-se que as amostras de café apresentam valores mais elevados de CAT (1130-1488 mg AAE/L) do que as amostras de bebidas (110 mg AAE/L em água aromatizada e 775 mg AAE/L em sumo). Os valores de CAT obtidos para amostras de sumo e água aromatizada na presença de NO• indicam que a amostra de sumo possui maior teor de CAT (526 mg AAE/L) conforme era esperado, do que a amostra de água aromatizada (172 mg AAE/L).