78 resultados para Quantification methods


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aims to evaluate the feasibility of using image-based cytometry (IBC) in the analysis of algal cell quantification and viability, using Pseudokirchneriella subcapitata as a cell model. Cell concentration was determined by IBC to be in a linear range between 1 × 105 and 8 × 106 cells mL−1. Algal viability was defined on the basis that the intact membrane of viable cells excludes the SYTOX Green (SG) probe. The disruption of membrane integrity represents irreversible damage and consequently results in cell death. Using IBC, we were able to successfully discriminate between live (SG-negative cells) and dead algal cells (heat-treated at 65 °C for 60 min; SG-positive cells). The observed viability of algal populations containing different proportions of killed cells was well correlated (R 2 = 0.994) with the theoretical viability. The validation of the use of this technology was carried out by exposing algal cells of P. subcapitata to a copper stress test for 96 h. IBC allowed us to follow the evolution of cell concentration and the viability of copper-exposed algal populations. This technology overcomes several main drawbacks usually associated with microscopy counting, such as labour-intensive experiments, tedious work and lack of the representativeness of the cell counting. In conclusion, IBC allowed a fast and automated determination of the total number of algal cells and allowed us to analyse viability. This technology can provide a useful tool for a wide variety of fields that utilise microalgae, such as the aquatic toxicology and biotechnology fields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eruca sativa (rocket salad) has been intensely consumed all over the world, insomuch as, this work was undertaken to evaluate the antioxidant status and the environmental contamination (positive and negative nutritional contribution) of leaves and stems from this vegetable. Antioxidant capacity of rocket salad was assessed by mean of optical methods, such as the total phenolic content (TPC), reducing power assay and DPPH radical scavenging activity. The extent of the environmental contamination was reached through the quantification of thirteen organochlorine pesticides (OCP) by using gas chromatography coupled with electron-capture detector (GC-ECD) and compound confirmations employing gas chromatography tandem mass-spectrometry (GC-MS/MS). The OCP residues were extracted by using Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) methodology.The extent of the environmental contamination was reached through the quantification of thirteen OCP by using gas chromatography coupled with electron-capture detector (GC-ECD) and compound confirmations employing GC-MS/MS. The OCP residues were extracted by using Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) methodology. This demonstrated that leaves presented more antioxidant activity than stems, emphasizing that leaves contained six times more polyphenolic compounds than stems. In what concerns the OCP occurrence, the average recoveries obtained at the three levels tested (40, 60 and 80 µg kg−1) ranged from 55% to 149% with a relative standard deviation of 11%, (except hexachrorobenzene). Three vegetables samples were collected from supermarkets and analysed following this study. According to data, only one sample achieved 16.21 of β-hexachlorocyclohexane, confirmed by GC-MS/MS. About OCP quantification, the data indicated that only one sample achieved 16.21 µg kg−1 of β-hexachlorocyclohexane, confirmed by GC-MS/MS, being the QuEChERS a good choice for the of OCPs extraction. Furthermore, the leaves consumption guaranty higher levels of antioxidants than stems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O ensaio de dureza, e mais concretamente o ensaio de micro dureza Vickers, é no universo dos ensaios mecânicos um dos mais utilizados quer seja na indústria, no ensino ou na investigação e desenvolvimento de produto no âmbito das ciências dos materiais. Na grande maioria dos casos, a utilização deste ensaio tem como principal aplicação a caracterização ou controlo da qualidade de fabrico de materiais metálicos. Sendo um ensaio de relativa simplicidade de execução, rapidez e com resultados comparáveis e relacionáveis a outras grandezas físicas das propriedades dos materiais. Contudo, e tratando-se de um método de ensaio cuja intervenção humana é importante, na medição da indentação gerada por penetração mecânica através de um sistema ótico, não deixa de exibir algumas debilidades que daí advêm, como sendo o treino dos técnicos e respetivas acuidades visuais, fenómenos de fadiga visual que afetam os resultados ao longo de um turno de trabalho; ora estes fenómenos afetam a repetibilidade e reprodutibilidade dos resultados obtidos no ensaio. O CINFU possui um micro durómetro Vickers, cuja realização dos ensaios depende de um técnico treinado para a execução do mesmo, apresentando todas as debilidades já mencionadas e que o tornou elegível para o estudo e aplicação de uma solução alternativa. Assim, esta dissertação apresenta o desenvolvimento de uma solução alternativa ao método ótico convencional na medição de micro dureza Vickers. Utilizando programação em LabVIEW da National Instruments, juntamente com as ferramentas de visão computacional (NI Vision), o programa começa por solicitar ao técnico a seleção da câmara para aquisição da imagem digital acoplada ao micro durómetro, seleção do método de ensaio (Força de ensaio); posteriormente o programa efetua o tratamento da imagem (aplicação de filtros para eliminação do ruído de fundo da imagem original), segue-se, por indicação do operador, a zona de interesse (ROI) e por sua vez são identificadas automaticamente os vértices da calote e respetivas distâncias das diagonais geradas concluindo, após aceitação das mesmas, com o respetivo cálculo de micro dureza resultante. Para validação dos resultados foram utilizados blocos-padrão de dureza certificada (CRM), cujos resultados foram satisfatórios, tendo-se obtido um elevado nível de exatidão nas medições efetuadas. Por fim, desenvolveu-se uma folha de cálculo em Excel com a determinação da incerteza associada às medições de micro dureza Vickers. Foram então comparados os resultados nas duas metodologias possíveis, pelo método ótico convencional e pela utilização das ferramentas de visão computacional, tendo-se obtido bons resultados com a solução proposta.