76 resultados para multiple square wave voltammetry
Resumo:
Fluvoxamine (FVX) can be reduced at a mercury- drop electrode, with a maximum peak current intensity being obtained at a potential of -0.7 V vs. Ag/ AgCl, in an aqueous electrolyte solution of pH 2. The compound was determined in a pharmaceutical product and in spiked human serum by square-wave adsorptivestripping voltammetry (SWAdSV) after accumulation at the electrode surface, under batch conditions. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was also possible to determine FVX in the pharmaceutical product by use of a flow-injection analysis (FIA) system with SWAdSV detection. The methods developed were validated and successfully applied to the quantification of FVX in a pharmaceutical product. Recoveries between 76 and 89% were obtained in serum analysis. The FIA– SWAdSV method enabled analysis of up to 120 samples per hour at reduced cost, implying the possibility of competing with the chromatographic methods usually used for this analysis.
Resumo:
Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with SWAdSV detection (FIA-SWAdSV) were developed for the determination of paroxetine (PRX). The methods were based on the reduction of PRX at a mercury drop electrode at −1.55V versus Ag/AgCl, in a borate buffer of pH 8.8, and the possibility of accumulating the compound at the electrode surface. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was also possible to determine PRX using FIASWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs. Both methods developed were validated and successfully applied to the quantification of PRX in pharmaceutical products.
Resumo:
An electrochemical method is proposed for the determination of maltol in food. Microwave-assisted extraction procedures were developed to assist sample pre-treating steps. Experiments carried out in cyclic voltammetry showed an irreversible and adsorption controlled reduction of maltol. A cathodic peak was observed at -1.0 V for a Hanging Mercury Drop Electrode versus an AgCl/Ag (in saturated KCl), and the peak potential was pH independent. Square wave voltammetric procedures were selected to plot calibration curves. These procedures were carried out with the optimum conditions: pH 6.5; frequency 50 Hz; deposition potential 0.6 V; and deposition time 10 s. A linear behaviour was observed within 5.0 × 10-8 and 3.5 × 10-7 M. The proposed method was applied to the analysis of cakes, and results were compared with those obtained by an independent method. The voltammetric procedure was proven suitable for the analysis of cakes and provided environmental and economical advantages, including reduced toxicity and volume of effluents and decreased consumption of reagents.
Resumo:
A novel reusable molecularly imprinted polymer (MIP) assembled on a polymeric layer of carboxylated poly(vinyl chloride) (PVCsingle bondCOOH) for myoglobin (Myo) detection was developed. This polymer was casted on the gold working area of a screen printed electrode (Au-SPE), creating a novel disposable device relying on plastic antibodies. Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and Fourier transform infrared spectroscopy (FTIR) studies confirmed the surface modification. The MIP/Au-SPE devices displayed a linear behaviour in EIS from 0.852 to 4.26 μg mL−1, of positive slope 6.50 ± 1.48 (kΩ mL μg−1). The limit of detection was 2.25 μg mL−1. Square wave voltammetric (SWV) assays were made in parallel and showed linear responses between 1.1 and 2.98 μg mL−1. A current decrease was observed against Myo concentration, producing average slopes of −0.28 ± 0.038 μA mL μg−1. MIP/Au-SPE also showed good results in terms of selectivity. The error% found for each interfering species were 7% for troponin T (TnT), 11% for bovine serum albumin (BSA) and 2% for creatine kinase MB (CKMB), respectively. Overall, the technical modification over the Au-SPE was found a suitable approach for screening Myo in biological fluids.
Resumo:
The purpose of this work was to develop a reliable alternative method for the determination of the dithiocarbamate pesticide mancozeb (MCZ) in formulations. Furthermore, a method for the analysis of MCZ's major degradation product, ethylenethiourea (ETU), was also proposed. Cyclic voltammetry was used to characterize the electrochemical behavior of MCZ and ETU, and square-wave adsorptive stripping voltammetry (SWAdSV) was employed for MCZ quantification in commercial formulations. It was found that both MCZ and ETU are irreversibly reduced (− 0.6 V and − 0.5 V vs Ag/AgCl, respectively) at the surface of a glassy carbon electrode in a mainly diffusion-controlled process, presenting maximum peak current intensities at pH 7.0 (in phosphate buffered saline electrolyte). Several parameters of the SWAdSV technique were optimized and linear relationships between concentration and peak current intensity were established between 10–90 μmol L− 1 and 10–110 μmol L− 1 for MCZ and ETU, respectively. The limits of detection were 7.0 μmol L− 1 for MCZ and 7.8 μmol L− 1 for ETU. The optimized method for MCZ was successfully applied to the quantification of this pesticide in two commercial formulations. The developed procedures provided accurate and precise results and could be interesting alternatives to the established methods for quality control of the studied products, as well as for analysis of MCZ and ETU in environmental samples.
Resumo:
This work describes the development of an electrochemical enzymatic biosensor for quantification of the pesticide formetanate hydrochloride (FMT). It is based on a gold electrode modified with electrodeposited gold nanoparticles and laccase. The principle behind its development relies on FMT's capacity to inhibit the laccase catalytic reaction that occurs in the presence of phenolic substrates. The optimum values for the relevant experimental variables such as gold nanoparticles electrochemical deposition (at − 0.2 V for 100 s), laccase immobilization (via glutaraldehyde cross-linking), laccase concentration (12.4 mg/mL), substrate selection and concentration (5.83×10−5 M of aminophenol), pH (5.0), buffer (Britton–Robinson), and square-wave voltammetric parameters were determined. The developed biosensor was successfully applied to FMT determination in mango and grapes. The attained limit of detection was 9.5×10−8 ± 9.5×10−10 M (0.02 ± 2.6×10−4 mg/kg on a fresh fruit weight basis). Recoveries for the five tested spiking levels ranged from 95.5 ± 2.9 (grapes) to 108.6 ± 2.5% (mango). The results indicated that the proposed device presents suitable characteristics in terms of sensitivity (20.58 ± 0.49 A/μM), linearity (9.43×10−7 to 1.13×10−5 M), accuracy, repeatability (RSD of 1.4%), reproducibility (RSD of 1.8%) and stability (19 days) for testing of compliance with established maximum residue limits of FMT in fruits and vegetables.
Resumo:
In this paper we wish to illustrate different perspectives used to create Multiple-Choice questions and we will show how we can improve these in the construction of math tests. As it is known, web technologies have a great influence on student’s behaviour. Based on an on-line project beginning at 2007 which has been contributing to help students on their individual work, we would like to share our experience and thoughts with colleagues who have a common concern when they have the task of constructing Multiple-Choice tests. We feel that Multiple-Choice tests play an important and a very useful supporting role in selfevaluation or self-examination of our students. Nonetheless, good Multiple–Choice Test Items are generally more complex and time-consuming to create than other types of tests. It requires a certain amount of skill. However, this skill maybe increases through study, practice and experience. This paper discusses a number of issues related to the use of Multiple-Choice questions, lists the advantages and disadvantages of this question format contrasting it with open questions. Some examples are given in this context.
Resumo:
Multiple-Choice items are used in many different kinds of tests in several areas of knowledge. They can be considered an interesting tool to the self-assessing or as an alternative or complementary instrument to the traditional methods for assessing knowledge. The objectivity and accuracy of the multiple-choice tests is an important reason to think about. They are especially useful when the number of students to evaluate is too large. Moodle (Modular Object-Oriented Dynamic Learning Environment) is an Open Source course management system centered around learners' needs and designed to support collaborative approaches to teaching and learning. Moodle offers to the users a rich interface, context-specific help buttons, and a wide variety of tools such as discussion forums, wikis, chat, surveys, quizzes, glossaries, journals, grade books and more, that allow them to learn and collaborate in a truly interactive space. Come together the interactivity of the Moodle platform and the objectivity of this kind of tests one can easily build manifold random tests. The proposal of this paper is to relate our journey in the construction of these tests and share our experience in the use of the Moodle platform to create, take advantage and improve the multiple-choices tests in the Mathematic area.
Resumo:
The purpose of this paper is to analyse if Multiple-Choice Tests may be considered an interesting alternative for assessing knowledge, particularly in the Mathematics area, as opposed to the traditional methods, such as open questions exams. In this sense we illustrate some opinions of the researchers in this area. Often the perception of the people about the construction of this kind of exams is that they are easy to create. But it is not true! Construct well written tests it’s a hard work and needs writing ability from the teachers. Our proposal is analyse the construction difficulties of multiple - choice tests as well some advantages and limitations of this type of tests. We also show the frequent critics and worries, since the beginning of this objective format usage. Finally in this context some examples of Multiple-Choice Items in the Mathematics area are given, and we illustrate as how we can take advantage and improve this kind of tests.
Resumo:
The oxidation of codeine on glassy carbon electrodes has been studied in detail using differential pulse voltammetry. The results obtained using a glassy carbon electrode clearly show a much more complex oxidation mechanism than that previously reported when platinum and gold electrodes were used. To clarify the codeine oxidative profile, several metabolites and analogues of this alkaloid, codeine N-oxide, norcodeine, dihydrocodeine, acetylcodeine and 6- chlorodesoxycodeine, were synthesized and studied. It was deduced that the anodic waves observed in codeine oxidation are related to the presence of methoxy, hydroxy and tertiary amine groups. Due to the similarity of potentials at which these oxidative processes take place, at some pHs an overlap of peaks occurs and only one anodic wave is observed.
Resumo:
The oxidative behavior of heroin in aqueous solution is reported. In order to identify its oxidation peaks, several metabolites, 6-monoacetylmorphine, 3-monoacetylmorphine and norheroin, were synthesized and their electrochemical behavior studied using differential pulse voltammetry. The anodic waves observed for heroin correspond to the oxidation of the tertiary amine group and its follow-up product (secondary amine), and to the oxidation of the phenolic group obtained from hydrolysis, at alkaline pHs, of the 3-acetyl group. The results enabled a new oxidative mechanism for heroin to be proposed in which a secondary amine, norheroin, and an aldehyde are obtained. The voltammetric behavior of 6-monoacetylmorphine and morphine was found to be similar demonstrating that the presence of an acetyl substituent on the 6-hydroxy group does not have a relevant influence on the peak potential of the wave resulting from oxidation of the 3-phenolic group.
Resumo:
An extraction-anodic adsorptive stripping voltammetric procedure using microwave-assisted solvent extraction and a gold ultramicroelectrode was developed for determining the pesticide ametryn in soil samples. The method is based on the use of acetonitrile as extraction solvent and on controlled adsorptive accumulation of the herbicide at the potential of 0.50 V (vs. Ag/AgCl) in the presence of Britton-Robinson buffer (pH 3.3). Soil sample extracts were analysed directly after drying and redissolution with the supporting electrolyte but without other pre-treatment. The limit of detection obtained for a 10 s collection time was 0.021 µg g-1. Recovery experiments for the global procedure, at the 0.500 µg g-1 level, gave satisfactory mean and standard deviation results which were comparable to those obtained by HPLC with UV detection.
Resumo:
We perform a comparison between the fractional iteration and decomposition methods applied to the wave equation on Cantor set. The operators are taken in the local sense. The results illustrate the significant features of the two methods which are both very effective and straightforward for solving the differential equations with local fractional derivative.
Resumo:
Recently, there have been a few research efforts towards extending the capabilities of fieldbus networks to encompass wireless support. In previous works we have proposed a hybrid wired/wireless PROFIBUS network solution where the interconnection between the heterogeneous communication media was accomplished through bridge-like interconnecting devices. The resulting networking architecture embraced a multiple logical ring (MLR) approach, thus with multiple independent tokens, to which a specific bridging protocol extension, the inter-domain protocol (IDP), was proposed. The IDP offers compatibility with standard PROFIBUS, and includes mechanisms to support inter-cell mobility of wireless nodes. We advance that work by proposing a worst-case response timing analysis of the IDP.
Resumo:
We propose a wireless medium access control (MAC) protocol that provides static-priority scheduling of messages in a guaranteed collision-free manner. Our protocol supports multiple broadcast domains, resolves the wireless hidden terminal problem and allows for parallel transmissions across a mesh network. Arbitration of messages is achieved without the notion of a master coordinating node, global clock synchronization or out-of-band signaling. The protocol relies on bit-dominance similar to what is used in the CAN bus except that in order to operate on a wireless physical layer, nodes are not required to receive incoming bits while transmitting. The use of bit-dominance efficiently allows for a much larger number of priorities than would be possible using existing wireless solutions. A MAC protocol with these properties enables schedulability analysis of sporadic message streams in wireless multihop networks.