37 resultados para post space preparation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Anticipatory postural adjustments during gait initiation have an important role in postural stability but also in gait performance. However, these first phase mechanisms of gait initiation have received little attention, particularly in subcortical post-stroke subjects, where bilateral postural control pathways can be impaired. This study aims to evaluate ankle anticipatory postural adjustments during gait initiation in chronic post-stroke subjects with lesion in the territory of middle cerebral artery. Methods: Eleven subjects with post-stroke hemiparesis with the ability to walk independently and twelve healthy controls participated in this study. Bilateral electromyographic activity of tibialis anterior, soleus and medial gastrocnemius was collected during gait initiation to assess the muscle onset timing, period of activation/deactivation and magnitude of muscle activity during postural phase of gait initiation. This phase was identified through centre of pressure signal. Findings: Post-stroke group presented only half of the tibialis anterior relative magnitude observed in healthy subjects in contralesional limb (t=2.38, p=0.027) and decreased soleus deactivation period (contralesional limb, t=2.25, p=0.04; ipsilesional limb, t=3.67, p=0.003) as well its onset timing (contralesional limb, t=3.2. p=0.005; ipsilesional limb, t=2.88, p=0.033) in both limbs. A decreased centre of pressure displacement backward (t=3.45, p=0.002) and toward the first swing limb (t=3.29, p=0.004) was observed in post-stroke subjects. Interpretation: These findings indicate that chronic post-stroke subjects with lesion at middle cerebral artery territory present dysfunction in ankle anticipatory postural adjustments in both limbs during gait initiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to compare two methods of assessing the postural phase of gait initiation as to intrasession reliability, in healthy and post-stroke subjects. As a secondary aim, this study aims to analyse anticipatory postural adjustments during gait initiation based on the centre of pressure (CoP) displacements in post-stroke participants. The CoP signal was acquired during gait initiation in fifteen post-stroke subjects and twenty-three healthy controls. Postural phase was identified through a baseline-based method and a maximal displacement based method. In both healthy and post-stroke participants higher intra-class correlation coefficient and lower coefficient of variation values were obtained with the baseline-based method when compared to the maximal displacement based method. Post-stroke participants presented decreased CoP displacement backward and toward the first swing limb compared to controls when the baseline-based method was used. With the maximal displacement based method, there were differences between groups only regarding backward CoP displacement. Postural phase duration in medial-lateral direction was also increased in post-stroke participants when using the maximal displacement based method. The findings obtained indicate that the baseline-based method is more reliable detecting the onset of gait initiation in both groups, while the maximal displacement based method presents greater sensitivity for post-stroke participants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atmospheric temperatures characterize Earth as a slow dynamics spatiotemporal system, revealing long-memory and complex behavior. Temperature time series of 54 worldwide geographic locations are considered as representative of the Earth weather dynamics. These data are then interpreted as the time evolution of a set of state space variables describing a complex system. The data are analyzed by means of multidimensional scaling (MDS), and the fractional state space portrait (fSSP). A centennial perspective covering the period from 1910 to 2012 allows MDS to identify similarities among different Earth’s locations. The multivariate mutual information is proposed to determine the “optimal” order of the time derivative for the fSSP representation. The fSSP emerges as a valuable alternative for visualizing system dynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Forecasting future sales is one of the most important issues that is beyond all strategic and planning decisions in effective operations of retail businesses. For profitable retail businesses, accurate demand forecasting is crucial in organizing and planning production, purchasing, transportation and labor force. Retail sales series belong to a special type of time series that typically contain trend and seasonal patterns, presenting challenges in developing effective forecasting models. This work compares the forecasting performance of state space models and ARIMA models. The forecasting performance is demonstrated through a case study of retail sales of five different categories of women footwear: Boots, Booties, Flats, Sandals and Shoes. On both methodologies the model with the minimum value of Akaike's Information Criteria for the in-sample period was selected from all admissible models for further evaluation in the out-of-sample. Both one-step and multiple-step forecasts were produced. The results show that when an automatic algorithm the overall out-of-sample forecasting performance of state space and ARIMA models evaluated via RMSE, MAE and MAPE is quite similar on both one-step and multi-step forecasts. We also conclude that state space and ARIMA produce coverage probabilities that are close to the nominal rates for both one-step and multi-step forecasts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente documento relata todas as atividades que foram desenvolvidas no estágio curricular realizado na empresa Bosch Car Multimédia em Braga, no âmbito da disciplina "Dissertação/ Projeto/Estágio Profissional"do Mestrado em Engenharia de Instrumentação e Metrologia, do Instituto Superior de Engenharia do Porto. Sendo a Bosch uma empresa de grandes dimensões, necessita de inúmeros equipamentos elétricos devido aos elevados padrões de qualidade exigidos, para poder estar em conformidade a nível das calibrações. A redução de custos e dos tempos de calibração foram as principais motivações para a implementação de um Laboratório de Metrologia Elétrica na empresa. Inicialmente, foi destinado um espaço para o laboratório e adquirido todo o equipamento necessário. Além disto, foi necessário treinar e formar os colaboradores destinados ao laboratório, quer na área das normas a aplicar no processo, quer em específico, com a empresa fornecedora do software de calibração. Ao longo dos doze meses, o estágio teve diversas fases, desde a aprendizagem do software utilizado, METCAL, elaboração de procedimentos de calibração para cada tipo de equipamentos na fábrica, realização de calibrações em coordenação com as diferentes áreas da empresa nos tempos e datas programados e análise dos certificados com sentido crítico, nomeadamente a nível de layout apresentado e incertezas associadas, para que o processo possa constantemente ser melhorado. Todas estas fases possibilitaram a aquisição e aplicação de vários conceitos importantes na área da Metrologia Elétrica. A implementação de um Laboratório de Metrologia é um processo bastante longo e complexo, e por estas razões, atualmente ainda se realizam procedimentos para novos tipos de equipamentos, sendo feitas melhorias e estudos para que no futuro, a sua capacidade seja cada vez maior e melhor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Post-MAPS is a web platform that collects gastroenterological exam data from several european hospital centers, to be used in future clinical studies and was developed in partnership with experts from the gastroenterological area and information technology (IT) technicians. However, although functional, this platform has some issues that are crucial for its functioning, and can render user interaction unpleasant and exhaustive. Accordingly, we proposed the development of a new web platform, in which we aimed for an improvement in terms of usability, data uni cation and interoperability. Therefore, it was necessary to identify and study different ways of acquiring clinical data and review some of the existing clinical databases in order to understand how they work and what type of data they store, as well as their impact and contribution to clinical knowledge. Closely linked to the data model is the ability to share data with other systems, so, we also studied the concept of interoperability and analyzed some of the most widely used international standards, such as DICOM, HL7 and openEHR. As one of the primary objectives of this project was to achieve a better level of usability, practices related to Human Computer-Interaction, such as requirement analysis, creation of conceptual models, prototyping, and evaluation were also studied. Before we began the development, we conducted an analysis of the previous platform, from a functional point of view, which allowed us to gather not only a list of architectural and interface issues, but also a list of improvement opportunities. It was also performed a small preliminary study in order to evaluate the platform's usability, where we were able to realize that perceived usability is different between users, and that, in some aspects, varies according to their location, age and years of experience. Based on the information gathered during the platform's analysis and in the conclusions of the preliminary study, a new platform was developed, prepared for all potential users, from the inexperienced to the most comfortable with technology. It presents major improvements in terms of usability, also providing several new features that simplify the users' work, improving their interaction with the system, making their experience more enjoyable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A crescente necessidade de reduzir a dependência energética e a emissão de gases de efeito de estufa levou à adoção de uma série de políticas a nível europeu com vista a aumentar a eficiência energética e nível de controlo de equipamentos, reduzir o consumo e aumentar a percentagem de energia produzida a partir de fontes renováveis. Estas medidas levaram ao desenvolvimento de duas situações críticas para o setor elétrico: a substituição das cargas lineares tradicionais, pouco eficientes, por cargas não-lineares mais eficientes e o aparecimento da produção distribuída de energia a partir de fontes renováveis. Embora apresentem vantagens bem documentadas, ambas as situações podem afetar negativamente a qualidade de energia elétrica na rede de distribuição, principalmente na rede de baixa tensão onde é feita a ligação com a maior parte dos clientes e onde se encontram as cargas não-lineares e a ligação às fontes de energia descentralizadas. Isto significa que a monitorização da qualidade de energia tem, atualmente, uma importância acrescida devido aos custos relacionados com perdas inerentes à falta de qualidade de energia elétrica na rede e à necessidade de verificar que determinados parâmetros relacionados com a qualidade de energia elétrica se encontram dentro dos limites previstos nas normas e nos contratos com clientes de forma a evitar disputas ou reclamações. Neste sentido, a rede de distribuição tem vindo a sofrer alterações a nível das subestações e dos postos de transformação que visam aumentar a visibilidade da qualidade de energia na rede em tempo real. No entanto, estas medidas só permitem monitorizar a qualidade de energia até aos postos de transformação de média para baixa tensão, não revelando o estado real da qualidade de energia nos pontos de entrega ao cliente. A monitorização nestes pontos é feita periodicamente e não em tempo real, ficando aquém do necessário para assegurar a deteção correta de problemas de qualidade de energia no lado do consumidor. De facto, a metodologia de monitorização utilizada atualmente envolve o envio de técnicos ao local onde surgiu uma reclamação ou a um ponto de medição previsto para instalar um analisador de energia que permanece na instalação durante um determinado período de tempo. Este tipo de monitorização à posteriori impossibilita desde logo a deteção do problema de qualidade de energia que levou à reclamação, caso não se trate de um problema contínuo. Na melhor situação, o aparelho poderá detetar uma réplica do evento, mas a larga percentagem anomalias ficam fora deste processo por serem extemporâneas. De facto, para detetar o evento que deu origem ao problema é necessário monitorizar permanentemente a qualidade de energia. No entanto este método de monitorização implica a instalação permanente de equipamentos e não é viável do ponto de vista das empresas de distribuição de energia já que os equipamentos têm custos demasiado elevados e implicam a necessidade de espaços maiores nos pontos de entrega para conter os equipamentos e o contador elétrico. Uma alternativa possível que pode tornar viável a monitorização permanente da qualidade de energia consiste na introdução de uma funcionalidade de monitorização nos contadores de energia de determinados pontos da rede de distribuição. Os contadores são obrigatórios em todas as instalações ligadas à rede, para efeitos de faturação. Tradicionalmente estes contadores são eletromecânicos e recentemente começaram a ser substituídos por contadores inteligentes (smart meters), de natureza eletrónica, que para além de fazer a contagem de energia permitem a recolha de informação sobre outros parâmetros e aplicação de uma serie de funcionalidades pelo operador de rede de distribuição devido às suas capacidades de comunicação. A reutilização deste equipamento com finalidade de analisar a qualidade da energia junto dos pontos de entrega surge assim como uma forma privilegiada dado que se trata essencialmente de explorar algumas das suas características adicionais. Este trabalho tem como objetivo analisar a possibilidade descrita de monitorizar a qualidade de energia elétrica de forma permanente no ponto de entrega ao cliente através da utilização do contador elétrico do mesmo e elaborar um conjunto de requisitos para o contador tendo em conta a normalização aplicável, as características dos equipamentos utilizados atualmente pelo operador de rede e as necessidades do sistema elétrico relativamente à monitorização de qualidade de energia.