142 resultados para operation control


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Currently, power systems (PS) already accommodate a substantial penetration of distributed generation (DG) and operate in competitive environments. In the future, as the result of the liberalisation and political regulations, PS will have to deal with large-scale integration of DG and other distributed energy resources (DER), such as storage and provide market agents to ensure a flexible and secure operation. This cannot be done with the traditional PS operational tools used today like the quite restricted information systems Supervisory Control and Data Acquisition (SCADA) [1]. The trend to use the local generation in the active operation of the power system requires new solutions for data management system. The relevant standards have been developed separately in the last few years so there is a need to unify them in order to receive a common and interoperable solution. For the distribution operation the CIM models described in the IEC 61968/70 are especially relevant. In Europe dispersed and renewable energy resources (D&RER) are mostly operated without remote control mechanisms and feed the maximal amount of available power into the grid. To improve the network operation performance the idea of virtual power plants (VPP) will become a reality. In the future power generation of D&RER will be scheduled with a high accuracy. In order to realize VPP decentralized energy management, communication facilities are needed that have standardized interfaces and protocols. IEC 61850 is suitable to serve as a general standard for all communication tasks in power systems [2]. The paper deals with international activities and experiences in the implementation of a new data management and communication concept in the distribution system. The difficulties in the coordination of the inconsistent developed in parallel communication and data management standards - are first addressed in the paper. The upcoming unification work taking into account the growing role of D&RER in the PS is shown. It is possible to overcome the lag in current practical experiences using new tools for creating and maintenance the CIM data and simulation of the IEC 61850 protocol – the prototype of which is presented in the paper –. The origin and the accuracy of the data requirements depend on the data use (e.g. operation or planning) so some remarks concerning the definition of the digital interface incorporated in the merging unit idea from the power utility point of view are presented in the paper too. To summarize some required future work has been identified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the energy management of the isolated operation of small power system, the economic scheduling of the generation units is a crucial problem. Applying right timing can maximize the performance of the supply. The optimal operation of a wind turbine, a solar unit, a fuel cell and a storage battery is searched by a mixed-integer linear programming implemented in General Algebraic Modeling Systems (GAMS). A Virtual Power Producer (VPP) can optimal operate the generation units, assured the good functioning of equipment, including the maintenance, operation cost and the generation measurement and control. A central control at system allows a VPP to manage the optimal generation and their load control. The application of methodology to a real case study in Budapest Tech, demonstrates the effectiveness of this method to solve the optimal isolated dispatch of the DC micro-grid renewable energy park. The problem has been converged in 0.09 s and 30 iterations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies Optimal Intelligent Supervisory Control System (OISCS) model for the design of control systems which can work in the presence of cyber-physical elements with privacy protection. The development of such architecture has the possibility of providing new ways of integrated control into systems where large amounts of fast computation are not easily available, either due to limitations on power, physical size or choice of computing elements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes a new approach in the Intelligent Training of Operators in Power Systems Control Centres, considering the new reality of Renewable Sources, Distributed Generation, and Electricity Markets, under the emerging paradigms of Cyber-Physical Systems and Ambient Intelligence. We propose Intelligent Tutoring Systems as the approach to deal with the intelligent training of operators in these new circumstances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the context of electricity markets, transmission pricing is an important tool to achieve an efficient operation of the electricity system. The electricity market is influenced by several factors; however the transmission network management is one of the most important aspects, because the network is a natural monopoly. The transmission tariffs can help to regulate the market, for this reason transmission tariffs must follow strict criteria. This paper presents the following methods to tariff the use of transmission networks by electricity market players: Post-Stamp Method; MW-Mile Method Distribution Factors Methods; Tracing Methodology; Bialek’s Tracing Method and Locational Marginal Price. A nine bus transmission network is used to illustrate the application of the tariff methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Control Centre operators are essential to assure a good performance of Power Systems. Operators’ actions are critical in dealing with incidents, especially severe faults, like blackouts. In this paper we present an Intelligent Tutoring approach for training Portuguese Control Centre operators in incident analysis and diagnosis, and service restoration of Power Systems, offering context awareness and an easy integration in the working environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose- Economics and business have evolved as sciences in order to accommodate more of ‘real world’ solutions for the problems approached. In many cases, both business and economics have been supported by other disciplines in order to obtain a more complete framework for the study of complex issues. The aim of this paper is to explore the contribution of three heterodox economics disciplines to the knowledge of business co-operation. Design/methodology/approach- This approach is theoretical and it shows that many relevant aspects of business co-operation have been proposed by economic geography, institutional economics, and economic sociology. Findings- This paper highlights the business mechanisms of co-operation, reflecting on the role of places, institution and the social context where businesses operate. Research Implications- It contributes with a theoretical framework for the explanation of business co-operations and networks that goes beyond the traditional economics theories. Originality/value- This paper contributes with a framework for the study of business co-operation both from an economics and management perspective. This framework embodies a number of non-quantitative issues that are critical for understanding the complex networks in which firms operate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica – Sistemas Eléctricos de Energia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Paper and thin layer chromatography methods are frequently used in Classic Nuclear Medicine for the determination of radiochemical purity (RCP) on radiopharmaceutical preparations. An aliquot of the radiopharmaceutical to be tested is spotted at the origin of a chromatographic strip (stationary phase), which in turn is placed in a chromatographic chamber in order to separate and quantify radiochemical species present in the radiopharmaceutical preparation. There are several methods for the RCP measurement, based on the use of equipment as dose calibrators, well scintillation counters, radiochromatografic scanners and gamma cameras. The purpose of this study was to compare these quantification methods for the determination of RCP. Material and Methods: 99mTc-Tetrofosmin and 99mTc-HDP are the radiopharmaceuticals chosen to serve as the basis for this study. For the determination of RCP of 99mTc-Tetrofosmin we used ITLC-SG (2.5 x 10 cm) and 2-butanone (99mTc-tetrofosmin Rf = 0.55, 99mTcO4- Rf = 1.0, other labeled impurities 99mTc-RH RF = 0.0). For the determination of RCP of 99mTc-HDP, Whatman 31ET and acetone was used (99mTc-HDP Rf = 0.0, 99mTcO4- Rf = 1.0, other labeled impurities RF = 0.0). After the development of the solvent front, the strips were allowed to dry and then imaged on the gamma camera (256x256 matrix; zoom 2; LEHR parallel-hole collimator; 5-minute image) and on the radiochromatogram scanner. Then, strips were cut in Rf 0.8 in the case of 99mTc-tetrofosmin and Rf 0.5 in the case of 99mTc-HDP. The resultant pieces were smashed in an assay tube (to minimize the effect of counting geometry) and counted in the dose calibrator and in the well scintillation counter (during 1 minute). The RCP was calculated using the formula: % 99mTc-Complex = [(99mTc-Complex) / (Total amount of 99mTc-labeled species)] x 100. Statistical analysis was done using the test of hypotheses for the difference between means in independent samples. Results:The gamma camera based method demonstrated higher operator-dependency (especially concerning the drawing of the ROIs) and the measures obtained using the dose calibrator are very sensitive to the amount of activity spotted in the chromatographic strip, so the use of a minimum of 3.7 MBq activity is essential to minimize quantification errors. Radiochromatographic scanner and well scintillation counter showed concordant results and demonstrated the higher level of precision. Conclusions: Radiochromatographic scanners and well scintillation counters based methods demonstrate to be the most accurate and less operator-dependant methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Em Portugal, como em outros países, podem ser encontrados milhares de trabalhadores com doenças e outros problemas resultantes da exposição aos compostos orgânicos voláteis (COV’s). No entanto são poucos os estudos aplicados à actividade industrial. Neste trabalho validou-se/estimou-se a exposição ocupacional a COV´s dos trabalhadores que executam a tarefa de ‘aplicação de revestimento do mobiliário’, mais conhecida por ‘acabamento de móveis’ na secção de acabamentos do sector de mobiliário de madeira, que se situa nos concelhos de Paços de Ferreira e Paredes, concelhos do Norte de Portugal. A amostra foi constituída por 17 empresas e foram avaliados 34 tarefas que corresponde ao mesmo número de trabalhadores, uma vez que eles executam essa tarefa durante as oito horas diárias de trabalho. Para avaliar a exposição dos trabalhadores foram utilizadas duas abordagens da higiene do trabalho: a pragmática, através da aplicação do método Toolkit e a tradicional com recurso a amostragens de ar e análises laboratoriais. Os resultados obtidos sugerem que o Toolkit é uma boa ferramenta para ser utilizada pelas Pequenas e Médias Empresas (PME’s), que trabalhem com substâncias em pó ou líquidas. É um método expedito e que não acarreta grandes esforços financeiros. Verificou-se ainda que a maioria dos trabalhadores estão em risco de exposição a COV’s. Sendo necessário tomar medidas de controlo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho, elaborado entre Fevereiro e Julho de 2011, pretendeu analisar o impacto de algumas estratégias de optimização, adoptadas no âmbito da gestão de processo. As soluções estudadas tiveram como objectivo fazer face a alguns problemas de funcionamento da estação de tratamento de águas residuais (ETAR) de Crestuma, com recurso aos meios existentes. Para esse efeito foi realizada uma análise ao histórico dos registos de exploração referentes ao período de Janeiro de 2008 a Julho de 2011, pois foi considerado que este seria o período necessário para a análise e apuramento de resultados conclusivos. A ETAR fica situada na freguesia de Crestuma, actualmente com 2619 habitantes, localizada na confluência do regato de Vessadas com o rio Douro. Destina-se a tratar as águas residuais provenientes do sistema de drenagem de três localidades, S. Fioso, S. Picoto e S. Vessada, contribuindo para a despoluição do rio Douro. Genericamente, a ETAR tem apresentado um desempenho bastante satisfatório, respeitando os valores limites de emissão previstos na legislação actual (Decreto-Lei 152/97). A permanência de grandes quantidades de lama no processo, associada a uma elevada idade das lamas, está na origem da sua má sedimentabilidade, dificultando, por sua vez, a sua remoção do sistema. Com objectivo de se conseguir remover as lamas biológicas de uma forma mais eficiente, foi adoptada uma estratégia que compreendeu duas etapas. Com a finalidade de melhorar a sedimentabilidade, numa primeira etapa foi introduzido no processo um produto biológico, composto essencialmente por fungos, comercialmente conhecido por Optibiom 7450L. Com vista a obter-se uma maior eficiência na desidratação das lamas, a segunda etapa consistiu na substituição do polímero usado na lama espessada, por outro, de composição diferente, comercialmente conhecido por Easy 6040. Com as alterações introduzidas, foi possível obter um melhor controlo do processo e convergir para parâmetros de funcionamento mais próximos dos valores referidos na bibliografia. As alterações mais relevantes foram verificadas nos valores de sólidos suspensos totais (SST) no reactor biológico e na recirculação, tendo-se obtido valores médios de 3846 e 9716 mg/L, respectivamente (correspondendo a valores anteriores ao tratamento de 5301 e 7430 mg/L). Assim, a razão entre as concentrações de SST na corrente de recirculação e no reactor biológico passou de 1,4 para 2,6. A idade das lamas diminuiu de 42 para 36 dias com a adição do polímero Easy 6040 e o índice volumétrico de lamas apresentou uma redução, de 134 mL/g para 100 mL/g, o que se traduziu numa melhor sedimentabilidade das lamas. Desta forma, obteve-se uma diminuição de 33,3% no volume de lama produzida por m3 de afluente tratado, bem como uma redução de 27% no número de horas de funcionamento da centrífuga e um decréscimo ligeiro no consumo global de energia da ETAR (0,89%). Conclui-se que as alterações introduzidas no processo, adição de um produto biológico composto por fungos (Optibiom 7450L) e substituição do polímero usado na lama espessada por outro de composição diferente (Easy 6040), conduziram a uma melhoria no funcionamento do tratamento biológico da ETAR de Crestuma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The introduction of electricity markets and integration of Distributed Generation (DG) have been influencing the power system’s structure change. Recently, the smart grid concept has been introduced, to guarantee a more efficient operation of the power system using the advantages of this new paradigm. Basically, a smart grid is a structure that integrates different players, considering constant communication between them to improve power system operation and management. One of the players revealing a big importance in this context is the Virtual Power Player (VPP). In the transportation sector the Electric Vehicle (EV) is arising as an alternative to conventional vehicles propel by fossil fuels. The power system can benefit from this massive introduction of EVs, taking advantage on EVs’ ability to connect to the electric network to charge, and on the future expectation of EVs ability to discharge to the network using the Vehicle-to-Grid (V2G) capacity. This thesis proposes alternative strategies to control these two EV modes with the objective of enhancing the management of the power system. Moreover, power system must ensure the trips of EVs that will be connected to the electric network. The EV user specifies a certain amount of energy that will be necessary to charge, in order to ensure the distance to travel. The introduction of EVs in the power system turns the Energy Resource Management (ERM) under a smart grid environment, into a complex problem that can take several minutes or hours to reach the optimal solution. Adequate optimization techniques are required to accommodate this kind of complexity while solving the ERM problem in a reasonable execution time. This thesis presents a tool that solves the ERM considering the intensive use of EVs in the smart grid context. The objective is to obtain the minimum cost of ERM considering: the operation cost of DG, the cost of the energy acquired to external suppliers, the EV users payments and remuneration and penalty costs. This tool is directed to VPPs that manage specific network areas, where a high penetration level of EVs is expected to be connected in these areas. The ERM is solved using two methodologies: the adaptation of a deterministic technique proposed in a previous work, and the adaptation of the Simulated Annealing (SA) technique. With the purpose of improving the SA performance for this case, three heuristics are additionally proposed, taking advantage on the particularities and specificities of an ERM with these characteristics. A set of case studies are presented in this thesis, considering a 32 bus distribution network and up to 3000 EVs. The first case study solves the scheduling without considering EVs, to be used as a reference case for comparisons with the proposed approaches. The second case study evaluates the complexity of the ERM with the integration of EVs. The third case study evaluates the performance of scheduling with different control modes for EVs. These control modes, combined with the proposed SA approach and with the developed heuristics, aim at improving the quality of the ERM, while reducing drastically its execution time. The proposed control modes are: uncoordinated charging, smart charging and V2G capability. The fourth and final case study presents the ERM approach applied to consecutive days.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os hospitais necessitam de desenvolver programas de gestão de equipamentos médicos, onde contenha informação pertinente e uma metodologia de planeamento eficaz, para a aquisição do equipamento médico novo, assim como otimizar o controlo metrológico destes equipamentos. Para tal foi fornecida informação sobre os aspetos mais relevantes a ter em conta na compra do equipamento médico, como as especificações e funcionalidades necessárias, normas a que o equipamento deve obedecer, garantias, manutenção e calibração/verificação quando aplicável. A escolha dos equipamentos médicos incidiu sobre os esfigmomanómetros e os monitores de sinais vitais. Estudou-se o funcionamento destes equipamentos e prosseguiu-se depois para a realização de entrevistas aos seus utilizadores, com o intuito de perceber a satisfação, os critérios e as necessidades relativas aos equipamentos existentes na ULSM. Em seguida foram realizadas as fichas de normalização onde se definiram as características físicas, fisiológicas e tecnológicas associadas a ambos os tipos de dispositivos médicos. Posteriormente estudaram-se as normas com as quais os equipamentos devem estar em conformidade para garantir o bom funcionamento. Por fim pesquisou-se quais os requisitos metrológicos, técnicos e os procedimentos de verificação a que os equipamentos devem obedecer. Este documento irá servir como suporte para a aquisição e controlo dos equipamentos médicos aqui estudados, melhorando a sua gestão, manutenção e controlo metrológico.