40 resultados para STORAGE CAPACITY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accumulation of microcystin-LR (MC-LR) in edible aquatic organisms, particularly in bivalves, is widely documented. In this study, the effects of food storage and processing conditions on the free MC-LR concentration in clams (Corbicula fluminea) fed MC-LR-producing Microcystisaeruginosa (1 × 105 cell/mL) for four days, and the bioaccessibility of MC-LR after in vitro proteolytic digestion were investigated. The concentration of free MC-LR in clams decreased sequentially over the time with unrefrigerated and refrigerated storage and increased with freezing storage. Overall, cooking for short periods of time resulted in a significantly higher concentration (P < 0.05) of free MC-LR in clams, specifically microwave (MW) radiation treatment for 0.5 (57.5%) and 1 min (59%) and boiling treatment for 5 (163.4%) and 15 min (213.4%). The bioaccessibility of MC-LR after proteolytic digestion was reduced to 83%, potentially because of MC-LR degradation by pancreatic enzymes. Our results suggest that risk assessment based on direct comparison between MC-LR concentrations determined in raw food products and the tolerable daily intake (TDI) value set for the MC-LR might not be representative of true human exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O Despacho económico de um sistema eléctrico de energia com a coordenação hidrotérmica tem como objectivo alcançar a operação óptima do sistema em um determinado período de tempo, ao menor custo possível, e com alto grau de fiabilidade. O problema é muito complexo, pois depende do grau de dificuldade em se prever os caudais dos afluentes, e da capacidade das albufeiras das centrais hídricas. De um modo geral, a produção térmica é determinada de modo a proporcionar o uso mais racional possível da água, dentro do contexto de incertezas quanto às afluências futuras, de modo a, por um lado manter o sistemas o mais económico possível, e por outro, evitar o desperdício energético implícito em descarregamentos de volumes de água turbináveis. Neste trabalho é proposta uma metodologia baseada em programação linear para a solução da coordenação hidrotérmica de curto prazo, e que permite obter custos-sombra de água em centrais hídricas com armazenamento. Esta metodologia foi posteriormente implementado num programa computacional em Microsoft Excel 2010 para a solução numa primeira fase, da rede de 24 barramentos do IEEE, e numa segunda fase, para a solução da Rede Nacional de Transporte referente ao ano de 2010. Para efeitos de análise e validação de dados, os dados provenientes do programa, são depois comparados aos dados dos relatórios da REN. Por último, os dados provenientes do programa em Excel são colocados e analisados no programa PowerWorld Simulator 8.0.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In-network storage of data in wireless sensor networks contributes to reduce the communications inside the network and to favor data aggregation. In this paper, we consider the use of n out of m codes and data dispersal in combination to in-network storage. In particular, we provide an abstract model of in-network storage to show how n out of m codes can be used, and we discuss how this can be achieved in five cases of study. We also define a model aimed at evaluating the probability of correct data encoding and decoding, we exploit this model and simulations to show how, in the cases of study, the parameters of the n out of m codes and the network should be configured in order to achieve correct data coding and decoding with high probability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work measures and tries to compare the Antioxidant Capacity (AC) of 50 commercial beverages of different kinds: 6 wines, 12 beers, 18 soft drinks and 14 flavoured waters. Because there is no reference procedure established for this purpose, three different optical methods were used to analyse these samples: Total Radical trapping Antioxidant Parameter (TRAP), Trolox Equivalent Antioxidant Capacity (TEAC) and Ferric ion Reducing Antioxidant Parameter (FRAP). These methods differ on the chemical background and nature of redox system. The TRAP method involves the transfer of hydrogen atoms while TEAC and FRAP involves electron transfer reactions. The AC was also assessed against three antioxidants of reference, Ascorbic acid (AA), Gallic acid (GA) and 6-hydroxy-2,5,7,8-tetramethyl- 2-carboxylic acid (Trolox). The results obtained were analyzed statistically. Anova one-way tests were applied to all results and suggested that methods and standards exhibited significant statistical differences. The possible effect of sample features in the AC, such as gas, flavours, food colouring, sweeteners, acidity regulators, preservatives, stabilizers, vitamins, juice percentage, alcohol percentage, antioxidants and the colour was also investigated. The AC levels seemed to change with brand, kind of antioxidants added, and kind of flavour, depending on the sample. In general, higher ACs were obtained for FRAP as method, and beer for kind of sample, and the standard expressing the smaller AC values was GA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The total antioxidant capacity (TAC) of 28 flavoured water samples was assessed by ferric reducing antioxidant potential (FRAP), oxygen radical absorbance capacity (ORAC), trolox equivalent antioxidant capacity (TEAC) and total reactive antioxidant potential (TRAP) methods. It was observed that flavoured waters had higher antioxidant activity than the corresponding natural ones. The observed differences were attributed to flavours, juice and vitamins. Generally, higher TAC contents were obtained on lemon waters and lower values on guava and raspberry flavoured waters. Lower and higher TACs were obtained by TRAP and ORAC method, respectively. Statistical analysis suggested that vitamins and flavours increased the antioxidant content of the commercial waters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Demo in Workshop on ns-3 (WNS3 2015). 13 to 14, May, 2015. Castelldefels, Spain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endophyte-assisted phytoremediation has recently been suggested as a successful approach for ecological restoration of metal contaminated soils, however little information is available on the influence of endophytic bacteria on the phytoextraction capacity of metal hyperaccumulating plants in multi-metal polluted soils. The aims of our study were to isolate and characterize metal-resistant and 1-aminocyclopropane-1-carboxylate (ACC) utilizing endophytic bacteria from tissues of the newly discovered Zn/Cd hyperaccumulator Sedum plumbizincicola and to examine if these endophytic bacterial strains could improve the efficiency of phytoextraction of multi-metal contaminated soils. Among a collection of 42 metal resistant bacterial strains isolated from the tissues of S. plumbizincicola grown on Pb/Zn mine tailings, five plant growth promoting endophytic bacterial strains (PGPE) were selected due to their ability to promote plant growth and to utilize ACC as the sole nitrogen source. The five isolates were identified as Bacillus pumilus E2S2, Bacillus sp. E1S2, Bacillus sp. E4S1, Achromobacter sp. E4L5 and Stenotrophomonas sp. E1L and subsequent testing revealed that they all exhibited traits associated with plant growth promotion, such as production of indole-3-acetic acid and siderophores and solubilization of phosphorus. These five strains showed high resistance to heavy metals (Cd, Zn and Pb) and various antibiotics. Further, inoculation of these ACC utilizing strains significantly increased the concentrations of water extractable Cd and Zn in soil. Moreover, a pot experiment was conducted to elucidate the effects of inoculating metal-resistant ACC utilizing strains on the growth of S. plumbizincicola and its uptake of Cd, Zn and Pb in multi-metal contaminated soils. Out of the five strains, B. pumilus E2S2 significantly increased root (146%) and shoot (17%) length, fresh (37%) and dry biomass (32%) of S. plumbizincicola as well as plant Cd uptake (43%), whereas Bacillus sp. E1S2 significantly enhanced the accumulation of Zn (18%) in plants compared with non-inoculated controls. The inoculated strains also showed high levels of colonization in rhizosphere and plant tissues. Results demonstrate the potential to improve phytoextraction of soils contaminated with multiple heavy metals by inoculating metal hyperaccumulating plants with their own selected functional endophytic bacterial strains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we formulate the electricity retailers’ short-term decision-making problem in a liberalized retail market as a multi-objective optimization model. Retailers with light physical assets, such as generation and storage units in the distribution network, are considered. Following advances in smart grid technologies, electricity retailers are becoming able to employ incentive-based demand response (DR) programs in addition to their physical assets to effectively manage the risks of market price and load variations. In this model, the DR scheduling is performed simultaneously with the dispatch of generation and storage units. The ultimate goal is to find the optimal values of the hourly financial incentives offered to the end-users. The proposed model considers the capacity obligations imposed on retailers by the grid operator. The profit seeking retailer also has the objective to minimize the peak demand to avoid the high capacity charges in form of grid tariffs or penalties. The non-dominated sorting genetic algorithm II (NSGA-II) is used to solve the multi-objective problem. It is a fast and elitist multi-objective evolutionary algorithm. A case study is solved to illustrate the efficient performance of the proposed methodology. Simulation results show the effectiveness of the model for designing the incentive-based DR programs and indicate the efficiency of NSGA-II in solving the retailers’ multi-objective problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The integration of wind power in eletricity generation brings new challenges to unit commitment due to the random nature of wind speed. For this particular optimisation problem, wind uncertainty has been handled in practice by means of conservative stochastic scenario-based optimisation models, or through additional operating reserve settings. However, generation companies may have different attitudes towards operating costs, load curtailment, or waste of wind energy, when considering the risk caused by wind power variability. Therefore, alternative and possibly more adequate approaches should be explored. This work is divided in two main parts. Firstly we survey the main formulations presented in the literature for the integration of wind power in the unit commitment problem (UCP) and present an alternative model for the wind-thermal unit commitment. We make use of the utility theory concepts to develop a multi-criteria stochastic model. The objectives considered are the minimisation of costs, load curtailment and waste of wind energy. Those are represented by individual utility functions and aggregated in a single additive utility function. This last function is adequately linearised leading to a mixed-integer linear program (MILP) model that can be tackled by general-purpose solvers in order to find the most preferred solution. In the second part we discuss the integration of pumped-storage hydro (PSH) units in the UCP with large wind penetration. Those units can provide extra flexibility by using wind energy to pump and store water in the form of potential energy that can be generated after during peak load periods. PSH units are added to the first model, yielding a MILP model with wind-hydro-thermal coordination. Results showed that the proposed methodology is able to reflect the risk profiles of decision makers for both models. By including PSH units, the results are significantly improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Na sociedade atual, a preocupação com o ambiente, por um lado, e com o conforto e a segurança, por outro, faz com que a sustentabilidade energética se assuma como uma forma de intervenção adequada às exigências de qualidade de vida e à eficiência no âmbito da economia. Nesta conformidade, é incontornável a mais-valia do Smart Panel, um quadro elétrico inteligente criado com vista à consecução daqueles desideratos, o que motivou o tema do presente trabalho. Assim, pretende-se demonstrar as potencialidades do Smart Panel, um novo conceito de quadro elétrico que visa a otimização da sua funcionalidade na gestão dinâmica e pragmática das instalações elétricas, nomeadamente no que respeita ao controlo, monitorização e atuação sobre os dispositivos, quer in loco quer, sobretudo, à distância. Para a consecução deste objetivo, concorrem outros que o potenciam, designadamente a compreensão do funcionamento do quadro elétrico (QE) tradicional, a comparação deste com o Smart Panel e a demonstração das vantagens da utilização desta nova tecnologia. A grande finalidade do trabalho desenvolvido é, por um lado, colocar a formação académica ao serviço de um bom desempenho profissional futuro, por outro ir ao encontro da tendência tecnológica inerente às necessidades que o homem, hoje, tem de controlar. Deste modo, num primeiro momento, é feita uma abordagem geral ao quadro eléctrico tradicional a fim de ser compreendido o seu funcionamento, aplicações e potencialidades. Para tanto, a explanação inclui a apresentação de conceitos teóricos subjacentes à conceção, produção e montagem do QE. São explicitados os diversos componentes que o integram e funções que desempenham, bem como as interações que estabelecem entre si e os normativos a que devem obedecer, para conformidade. Houve a preocupação de incluir imagens coadjuvantes das explicações, descrições e procedimentos técnicos. No terceiro capítulo é abordada a tecnologia Smart Panel, introduzindo o conceito e objetivos que lhe subjazem. Explicita-se o modo de funcionamento deste sistema que agrupa proteção, supervisão, controlo, armazenamento e manutenção preventiva, e demonstra-se de que forma a capacidade de leitura de dados, de comunicação e de comando do quadro elétrico à distância se afigura uma revolução tecnológica facilitadora do cumprimento das necessidades de segurança, conforto e economia da vida moderna. Os capítulos quarto, quinto e sexto versam uma componente prática do trabalho. No capítulo quarto é explanado um suporte formativo e posterior demonstração do kit de ensaio, que servirá de apoio à apresentação da tecnologia Smart Panel aos clientes. Além deste suporte de formação, no quinto capítulo é elaborada uma lista de procedimentos de verificação a serem executados aos componentes de comunicação que integram o Smart Panel, para fornecimento ao quadrista. Por fim, no sexto capítulo incluem-se dois casos de estudo: o estudo A centra-se na aplicação da tecnologia Smart Panel ao projeto de um QE tradicional, que implica fazer o levantamento de toda a aparelhagem existente e, de seguida, proceder à transposição para a tecnologia Smart Panel por forma a cumprir os requisitos estabelecidos pelo cliente. O estudo de caso B consiste na elaboração de um projeto de um quadro eléctrico com a tecnologia Smart Panel em função de determinados requisitos e necessidades do cliente, por forma a garantir as funções desejadas.