39 resultados para Interior Architecture
Resumo:
Coarse Grained Reconfigurable Architectures (CGRAs) are emerging as enabling platforms to meet the high performance demanded by modern applications (e.g. 4G, CDMA, etc.). Recently proposed CGRAs offer time-multiplexing and dynamic applications parallelism to enhance device utilization and reduce energy consumption at the cost of additional memory (up to 50% area of the overall platform). To reduce the memory overheads, novel CGRAs employ either statistical compression, intermediate compact representation, or multicasting. Each compaction technique has different properties (i.e. compression ratio, decompression time and decompression energy) and is best suited for a particular class of applications. However, existing research only deals with these methods separately. Moreover, they only analyze the compaction ratio and do not evaluate the associated energy overheads. To tackle these issues, we propose a polymorphic compression architecture that interleaves these techniques in a unique platform. The proposed architecture allows each application to take advantage of a separate compression/decompression hierarchy (consisting of various types and implementations of hardware/software decoders) tailored to its needs. Simulation results, using different applications (FFT, Matrix multiplication, and WLAN), reveal that the choice of compression hierarchy has a significant impact on compression ratio (up to 52%), decompression energy (up to 4 orders of magnitude), and configuration time (from 33 n to 1.5 s) for the tested applications. Synthesis results reveal that introducing adaptivity incurs negligible additional overheads (1%) compared to the overall platform area.
Resumo:
20th International Conference on Reliable Software Technologies - Ada-Europe 2015 (Ada-Europe 2015), Madrid, Spain.
Resumo:
Demo in Workshop on ns-3 (WNS3 2015). 13 to 14, May, 2015. Castelldefels, Spain.
Resumo:
Poster presented in 28th GI/ITG International Conference on Architecture of Computing Systems (ARCS 2015). 25 to 28, Mar, 2015, Poster Session. Porto, Portugal.
Resumo:
A dissertação teve como finalidade a realização de uma Auditoria Energética e da Qualidade do Ar Interior ao edifício de serviços da Câmara Municipal de Vila Nova de Gaia. No intuito de alcançar esta finalidade foram seguidos, em todo o processo, os regulamentos em vigor até à presente data da dissertação, de apoio à especialidade, nomeadamente o Regulamento das Características de Comportamento Térmico dos Edifícios, Regulamento dos Sistemas Energéticos de Climatização em Edifícios e Regulamento dos Sistemas Energéticos de Climatização em Edifícios e da Qualidade do Ar Interior. Na análise à Qualidade do Ar Interior foram verificados quase todos os parâmetros impostos por lei, exceto os das bactérias e dos fungos. Para as substâncias como dióxido de carbono (CO2), monóxido de carbono (CO), ozono (O3), formaldeído (HCOH) e radão, os valores em média foram iguais a 894 ppm, 1,23 ppm, 0,07 ppm, 0,01 ppm e 378 Bq/m3 e estavam dentro dos limites regulamentares (984 ppm, 10,7ppm, 0,10 ppm, 0,08 ppm e 400 Bq/m3). Para os compostos orgânicos voláteis (COVs) e partículas do tipo PM10, os valores respetivos foram em média de 0,70 ppm e 0,16 mg/m3 e estavam acima dos limites regulamentares (0,26 ppm, 0,15 mg/m3). Admite-se que existem fontes emissoras de COVs dentro do edifício e que, para uma adequação ao tipo de tratamento ou sugestão de melhoria, seria necessário realizar uma análise por cromatografia de forma a identificar os compostos em causa. As concentrações de PM10 mais elevadas explicam-se porque existe uma abertura direta desses espaços ao exterior e em alguns casos esta é permanente. A análise energética permitiu um levantamento de todos os consumos de energia elétrica do edifício, realizando deste modo a desagregação em percentagem de cada equipamento consumidor. Em paralelo e até para se poder realizar a certificação energética do edifício foi realizado um estudo de simulação térmica dinâmica recorrendo ao programa DesignBuilder v2. Criou-se um modelo do edifício que foi validado após simulação e comparação com o consumo elétrico do ano de referência (desvio de 2,78%). Pela simulação verificou-se que os maiores consumidores de energia são a iluminação interior e o sistema de arrefecimento e determinou-se os Indicadores de Eficiência Energética (IEE) Real (com correção climática) e Nominal com valores de 73,8 e 46,5 , respetivamente. Implementando as condições nominais de utilização e funcionamento no edifício, segundo o Regulamento dos Sistemas Energéticos de vi Climatização em Edifícios (RSECE), concluiu-se que a classe energética deste edifício é do tipo D. O valor do IEE nominal foi superior ao IEE referência de 35,5 , e o requisito legal não se verificou. Assim, foi necessário apresentar medidas para um plano de racionalização energética (PRE). Nas medidas estudadas de melhoria da eficiência energética (aplicação de películas solares, compensação do fator de potência, instalação de um sistema de minigeração fotovoltaico e aplicação de iluminação eficiente tanto no interior como no exterior do edifício) destaca-se a correção do fator de potência, pois o valor pago de energia reactiva em 2011 foi de cerca de 1500 €. Admitindo ser necessário redimensionar os condensadores e que o custo é 1.840,00 €, ter-se-á um retorno do investimento em 1,2 anos. Outra medida é a aplicação de películas solares nos envidraçados com um custo de 5.046,00 €, esta terá um período de retorno de 1 ano e uma poupança de 37,90 MWh/ano. Finalmente refere-se a instalação de reguladores de tensão e substituição de determinadas lâmpadas por LEDs na iluminação interior, que prevê uma poupança anual de 25 MWh/ano e um período de retorno do investimento de 3,7 anos.
Resumo:
Presented at INForum - Simpósio de Informática (INFORUM 2015). 7 to 8, Sep, 2015. Covilhã, Portugal.
Resumo:
Presented at INForum - Simpósio de Informática (INFORUM 2015). 7 to 8, Sep, 2015. Portugal.
Resumo:
Crowdsourcing is evolving into powerful outsourcing options for organizations by providing access to the intellectual capital within a vast knowledge community. Innovation brokering services have emerged to facilitate crowdsourcing projects by connecting up companies with potential solution providers within the wider ‘crowd’. Most existing innovation brokering services are primarily aimed at larger organizations, however, Small and Medium Enterprises (SMEs) offer considerable potential for crowdsourcing activity since they are typically the innovation and employment engines in society; they are typically more nimble and responsive to the business environment than the larger companies. SMEs have very different challenges and needs to larger organizations since they have fewer resources, a more limited knowledge and skill base, and immature management practices. Consequently, innovation brokering for SMEs require considerably more support than for larger organizations. This paper identifies the crowdsourcing innovation brokerage facilities needed by SMEs, and presents an architecture that encourages knowledge sharing, development of community, support in mixing and matching capabilities, and management of stakeholders’ risks. Innovation brokering is emerging as a novel business model that is challenging concepts of the traditional value chain and organizational boundaries.
Resumo:
Esta dissertação descreve o trabalho desenvolvido ao longo de um ano e um mês desde a pesquisa teórica até à prática experimental no âmbito da unidade curricular de Dissertação/estágio do Mestrado em Engenharia Química, no ramo Tecnologias em Proteção Ambiental. O tema desta dissertação consiste na avaliação do funcionamento de duas estações de tratamento de águas residuais (ETAR) do interior do município de Vila Nova de Gaia no que diz respeito ao possível aumento da resistência a antibióticos na ETAR de Febros e na ETAR de Lever. Os testes de sensibilidade a antibióticos (TSA) foram executados para ambas as ETAR, sendo as amostras de água recolhidas na entrada e na saída dos reatores biológicos (tratamento secundário). Além disso, foram realizados testes de avaliação da eficiência de desinfeção por radiação ultravioleta (UV) relativamente à Escherichia coli (E. coli) na ETAR de Lever. Os antibióticos selecionados para a realização deste trabalho foram a Eritromicina, a Azitromicina, a Claritromicina, a Ofloxacina, a Ciprofloxacina, o Sulfametoxazol, o Trimetoprim e o Metronidazol. Esta seleção baseou-se no facto de estes serem alguns dos antibióticos mais consumidos e mais persistentes no meio ambiente. A bactéria E. coli (isolada a partir de amostras das águas residuais estudadas) foi escolhida para a realização deste estudo uma vez que está sempre presente nas águas residuais domésticas e está associada a fenómenos de multirresistência a antibióticos. Os testes de TSA foram realizados seguindo a metodologia de difusão por discos. No período do estudo (Março a Junho de 2015) identificaram-se situações quer de aumento de resistência quer de aumento de sensibilidade aos antibióticos testados. As situações mais graves de aumento de resistência, a que corresponderam a halos nulos, verificaram-se para os antibióticos Claritromicina, Trimetoprim e Metronidazol, ocorrendo com maior frequência para os dois últimos, que aliás são fármacos que são administrados em simultâneo. Os períodos mais problemáticos em termos de aumento das resistências foram ligeiramente diferentes nas duas ETAR. No caso da ETAR de Febros correspondeu ao mês Abril e na ETAR de Lever ocorreu entre o final de Abril e o início de Maio. Considera-se que estes períodos poderão coincidir com um aumento do consumo destes fármacos devido à sua utilização no combate a infeções respiratórias muito comuns nesta altura do ano. Não se observou qualquer sensibilidade da E. coli para o Metronidazol porque é um antibiótico com indicação para algumas bactérias anaeróbias, fungos e giardia, e que à partida não tem capacidade para eliminar a E. coli. A eficiência da desinfeção na ETAR de Lever relativamente à remoção de E. coli foi satisfatória. Sendo de salientar a importância da manutenção, no que se refere à identificação de possíveis avarias nas lâmpadas e correspondente limpeza. Os resultados deste trabalho provam a existência de estirpes da bactéria E. coli resistentes a alguns dos antibióticos estudados, o que reforça a importância da desinfeção no tratamento de águas residuais domésticas.