58 resultados para Gas distribution.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traffic emissions and tobacco smoke are considered two main sources of polycyclic aromatic hydrocarbons (PAHs) in indoor and outdoor air. In this study, the impact of these sources on the level of fine particulate matter (PM2.5) and on the distribution of 15 PAHs regarded as priority pollutants by the US-EPA on PM2.5 were evaluated and compared. Outdoor and indoor PM2.5 samples were collected during winter 2008 in Oporto city in Portugal, for sampling periods of 12 and 24 hours, respectively. The outdoor PM2.5 were sampled at one site directly influenced by traffic emissions and the indoor PM2.5 samples were collected at one home directly influenced by tobacco smoke and another one without smoke. A methodology based on microwave-assisted extraction and liquid chromatography with fluorescence detection was applied for the efficient PAHs determination in indoor and outdoor PM2.5. PAHs in indoor PM2.5 concentrations were significantly influenced by the presence of traffic and tobacco smoking emissions. The mean of ΣPAHs in the outdoor traffic PM2.5 was not significantly different from the value attained in the indoor without smoking site. The tobacco smoke increased significantly PAHs concentrations on average about 1000 times more, when compared with the outdoor profile samples suggesting that tobacco smoking may be the most important source of indoor PAHs pollution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p’-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A SPME-GC-MS/MS method for the determination of eight organophosphorus pesticides (azinphos-methyl, chlorpyriphos, chlorpyriphos-methyl, diazinon, fenitrothion, fenthion, malathion, and methidathion) in still and fortified wine was developed. The extraction procedure is simple, solvent free, and without any sample pretreatment. Limits of detection (LOD) and quantitation (LOQ) values in the range 0.1–14.3 lg/L and 0.2–43.3 lg/L, respectively, were obtained. The LOQ values are below the maximum residue levels (MRLs) established by European Regulation for grapes, with the exception of methidathion. Coefficients of correlation (R2) higher than 0.99 were obtained for the majority of the pesticides, in all different wines analyzed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work describes a solid-phase microextraction (SPME) gas chromatography_tandem mass spectrometry (MS/MS) method to quantify 24 pesticides in fortified white wine and fortified red wine. In this study “fortified wine” refers to a wine in which fermentation is arrested before completion by alcohol distillate addition, allowing sugar and alcoholic contents to be higher (around 80-100 g/L total sugars and 19-22% alcohol strength (v/v)). The analytical method showed good linearity, presenting correlation coefficients (R2) ≥ 0.989 for all compounds. Limits of detection (LOD) and quantitation (LOQ) in the ranges of 0.05-72.35 and 0.16-219.23 μg/L, respectively, were obtained. LOQs are below the maximum residue levels (MRL) set by European Regulation for grapes. The proposed method was applied to 17 commercial fortified wines. The analyzed pesticides were not detected in the wines tested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A procedure for the determination of seven indicator PCBs in soils and sediments using microwave-assisted extraction (MAE) and headspace solid-phase microextraction (HS-SPME) prior to GC-MS/MS is described. Optimization of the HS-SPME was carried out for the most important parameters such as extraction time, sample volume and temperature. The adopted methodology has reduced consumption of organic solvents and analysis runtime. Under the optimized conditions, the method detection limit ranged from 0.6 to 1 ng/g when 5 g of sample was extracted, the precision on real samples ranged from 4 to 21% and the recovery from 69 to 104%. The proposed method, which included the analysis of a certified reference material in its validation procedure, can be extended to several other PCBs and used in the monitoring of soil or sediments for the presence of PCBs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amulti-residue methodology based on a solid phase extraction followed by gas chromatography–tandem mass spectrometry was developed for trace analysis of 32 compounds in water matrices, including estrogens and several pesticides from different chemical families, some of them with endocrine disrupting properties. Matrix standard calibration solutions were prepared by adding known amounts of the analytes to a residue-free sample to compensate matrix-induced chromatographic response enhancement observed for certain pesticides. Validation was done mainly according to the International Conference on Harmonisation recommendations, as well as some European and American validation guidelines with specifications for pesticides analysis and/or GC–MS methodology. As the assumption of homoscedasticity was not met for analytical data, weighted least squares linear regression procedure was applied as a simple and effective way to counteract the greater influence of the greater concentrations on the fitted regression line, improving accuracy at the lower end of the calibration curve. The method was considered validated for 31 compounds after consistent evaluation of the key analytical parameters: specificity, linearity, limit of detection and quantification, range, precision, accuracy, extraction efficiency, stability and robustness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this work were: (1) to identify an isotherm model to relate the contaminant contents in the gas phase with those in the solid and non-aqueous liquid phases; (2) to develop a methodology for the estimation of the contaminant distribution in the different phases of the soil; and (3) to evaluate the influence of soil water content on the contaminant distribution in soil. For sandy soils with negligible contents of clay and natural organic matter, contaminated with benzene, toluene, ethylbenzene, xylene, trichloroethylene (TCE), and perchloroethylene (PCE), it was concluded that: (1) Freundlich’s model showed to be adequate to relate the contaminant contents in the gas phase with those in the solid and non-aqueous liquid phases; (2) the distribution of the contaminants in the different phases present in the soil could be estimated with differences lower than 10% for 83% of the cases; and (3) an increase of the soil water content led to a decrease of the amount of contaminant in the solid and non-aqueous liquid phases, increasing the amount in the other phases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to characterize air pollution and the associated carcinogenic risks of polycyclic aromatic hydrocarbon (PAHs) at an urban site, to identify possible emission sources of PAHs using several statistical methodologies, and to analyze the influence of other air pollutants and meteorological variables on PAH concentrations.The air quality and meteorological data were collected in Oporto, the second largest city of Portugal. Eighteen PAHs (the 16 PAHs considered by United States Environment Protection Agency (USEPA) as priority pollutants, dibenzo[a,l]pyrene, and benzo[j]fluoranthene) were collected daily for 24 h in air (gas phase and in particles) during 40 consecutive days in November and December 2008 by constant low-flow samplers and using polytetrafluoroethylene (PTFE) membrane filters for particulate (PM10 and PM2.5 bound) PAHs and pre-cleaned polyurethane foam plugs for gaseous compounds. The other monitored air pollutants were SO2, PM10, NO2, CO, and O3; the meteorological variables were temperature, relative humidity, wind speed, total precipitation, and solar radiation. Benzo[a]pyrene reached a mean concentration of 2.02 ngm−3, surpassing the EU annual limit value. The target carcinogenic risks were equal than the health-based guideline level set by USEPA (10−6) at the studied site, with the cancer risks of eight PAHs reaching senior levels of 9.98×10−7 in PM10 and 1.06×10−6 in air. The applied statistical methods, correlation matrix, cluster analysis, and principal component analysis, were in agreement in the grouping of the PAHs. The groups were formed according to their chemical structure (number of rings), phase distribution, and emission sources. PAH diagnostic ratios were also calculated to evaluate the main emission sources. Diesel vehicular emissions were the major source of PAHs at the studied site. Besides that source, emissions from residential heating and oil refinery were identified to contribute to PAH levels at the respective area. Additionally, principal component regression indicated that SO2, NO2, PM10, CO, and solar radiation had positive correlation with PAHs concentrations, while O3, temperature, relative humidity, and wind speed were negatively correlated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Future distribution systems will have to deal with an intensive penetration of distributed energy resources ensuring reliable and secure operation according to the smart grid paradigm. SCADA (Supervisory Control and Data Acquisition) is an essential infrastructure for this evolution. This paper proposes a new conceptual design of an intelligent SCADA with a decentralized, flexible, and intelligent approach, adaptive to the context (context awareness). This SCADA model is used to support the energy resource management undertaken by a distribution network operator (DNO). Resource management considers all the involved costs, power flows, and electricity prices, allowing the use of network reconfiguration and load curtailment. Locational Marginal Prices (LMP) are evaluated and used in specific situations to apply Demand Response (DR) programs on a global or a local basis. The paper includes a case study using a 114 bus distribution network and load demand based on real data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the ground reaction forces (GRF) and plantar pressures between unloaded and occasional loaded gait. The GRF and plantar pressures of 60 participants were recorded during unloaded gait and occasional loaded gait (wearing a backpack that raised their body mass index to 30); this load criterion was adopted because is considered potentially harmful in permanent loaded gait (obese people). The results indicate an overall increase (absolute values) of GRF and plantar pressures during occasional loaded gait (p < 0.05); also, higher normalized (by total weight) values in the medial midfoot and toes, and lower values in the lateral rearfoot region were observed. During loaded gait the magnitude of the vertical GRF (impact and thrust maximum) decreased and the shear forces increased more than did the proportion of the load (normalized values). These data suggest a different pattern of GRF and plantar pressure distribution during occasional loaded compared to unloaded gait.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This technical report describes the PDFs which have been implemented to model the behaviours of certain parameters of the Repeater-Based Hybrid Wired/Wireless PROFIBUS Network Simulator (RHW2PNetSim) and Bridge-Based Hybrid Wired/Wireless PROFIBUS Network Simulator (BHW2PNetSim).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As alterações climáticas e as emissões de CO2 são questões que suscitam a nível internacional e nacional o desenvolvimento de estratégias que atenuem os seus impactes. A Eficiência Energética (EE) é essencial para que num futuro próximo não haja impactes significativos no meio ambiente devido a elevado e ineficiente consumo energético. A União Europeia (UE) e Portugal têm desenvolvido políticas e programas que estimulam a eficiência energética, bem como a diminuição de gases com efeito de estufa (GEE) e a promoção da utilização de fontes de energia renovável. Por outro lado vivemos numa sociedade que passa cerca de 80% do seu tempo em edifícios e, nestes, é consumida 40% da energia mundial. Com uma dependência energética superior a 80%, Portugal tem vindo a apostar, nos últimos anos, em fontes de energia renovável. Esta aposta serve como substituição de fontes, mas não leva directamente à redução de consumos. A redução da factura de energia só pode ser atingida com uma maior eficiência energética e melhores práticas de gestão de energia em edifícios, transportes e industria. Esta dissertação centra-se especificamente num conjunto de edifícios públicos, património municipal da autarquia de Matosinhos, cujo modelo de fornecimento da energia eléctrica é passível de análise crítica no sentido de uma optimização radical ao nível da concepção da rede e exploração, com consequente redução de custos ao nível da facturação. Esta nova metodologia de exploração e gestão de sistemas eléctricos incidirá na criação de um “campus” energético autárquico resultante do novo layout da rede e respectivo fornecimento de energia a partir da rede de distribuição pública. O estudo permitirá fornecer ferramentas fundamentais para a gestão municipal e empresarial ao nível da sustentabilidade energética nos edifícios públicos com abrangência aos serviços empresariais. De referir que a gestão das instalações eléctricas para optimização do desempenho, eficiência e qualidade de energia é aplicável aos 308 municípios nacionais com relevância para as empresas que apresentam consumos significativos nos seus edifícios. Enquanto funcionário da Câmara Municipal de Matosinhos, este município foi uma escolha natural como referência, na análise da relação existente entre a administração local e a gestão da energia. Para ajudar à análise foi efectuado um benchmarketing a cinco edifícios municipais: Edifício dos Paços do Concelho, Biblioteca Municipal Florbela Espanca, Palacete Visconde Trevões, ex-Edifício dos SMAS e Edifício do ex-Tribunal, visando potenciar a correcta gestão de energia destes edifícios por parte das entidades que os gerem, perante novas oportunidades de melhoria e soluções encontradas. Como contributo às metas impostas pela Directiva 2009/28/CE para 2020, a qual prevê uma redução de 20% no consumo final de energia através da eficiência energética, a incorporação de 20% de energia renovável no consumo energético global e a consequente redução em 20% da emissão de GEE, é apresentado um estudo ao nível de um parque fotovoltaico com a componente técnica e económica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O potencial de um reservatório de shale gas e influenciado por um grande número de fatores, tais como a sua mineralogia e textura, o seu tipo e maturação de querogénio, a saturação de fluidos, os mecanismos de armazenamento de gás, a profundidade do reservatório e a temperatura e pressão de poros. Nesse sentido, o principal objetivo desta tese foi estabelecer uma metodologia de avaliação preliminar de potenciais jazigos de shale gas (estudo de afloramentos com base numa litoestratigrafia de alta resolução), que foi posteriormente aplicada na Formação de Vale das Fontes (Bacia Lusitânica, Portugal). Esta tese tem a particularidade de contribuir, não só para o aprofundamento da informação a nível geoquímico do local, mas também na abordagem inovadora que permitiu a caracterização petrofísica da Formação de Vale das Fontes. Para a aplicação da metodologia estabelecida, foi necessária a realização dos seguintes ensaios laboratoriais: Rock-Eval 6, picnometria de gás hélio, ensaio de resistência a compressão simples, Darcypress e a difracção de raios-X, aplicando o método de Rietveld. Os resultados obtidos na análise petrofísica mostram uma formação rochosa de baixa porosidade que segundo a classificação ISRM, e classificada como ”Resistente”, para alem de revelar comportamento dúctil e elevado índice de fragilidade. A permeabilidade média obtida situa a Formação no intervalo correspondente as permeabilidades atribuídas aos jazigos de tigh gas, indicando a necessidade de fracturação hidráulica, no caso de uma eventual exploração de hidrocarbonetos, enquanto a difracção de raios-X destaca a calcite, o quartzo e os filossilicatos como os minerais mais presentes na Formação. Do ponto de vista geoquímico, os resultados obtidos mostram que apesar do considerável teor médio de carbono orgânico total, a natureza da matéria orgânica analisada e maioritariamente imatura, composta, principalmente, por querogénio do tipo IV, o que indica a incapacidade de a formação gerar hidrocarbonetos em quantidades economicamente exploráveis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a PSO based approach to increase the probability of delivering power to any load point by identifying new investments in distribution energy systems. The statistical failure and repair data of distribution components is the main basis of the proposed methodology that uses a fuzzyprobabilistic modeling for the components outage parameters. The fuzzy membership functions of the outage parameters of each component are based on statistical records. A Modified Discrete PSO optimization model is developed in order to identify the adequate investments in distribution energy system components which allow increasing the probability of delivering power to any customer in the distribution system at the minimum possible cost for the system operator. To illustrate the application of the proposed methodology, the paper includes a case study that considers a 180 bus distribution network.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a methodology to increase the probability of delivering power to any load point through the identification of new investments. The methodology uses a fuzzy set approach to model the uncertainty of outage parameters, load and generation. A DC fuzzy multicriteria optimization model considering the Pareto front and based on mixed integer non-linear optimization programming is developed in order to identify the adequate investments in distribution networks components which allow increasing the probability of delivering power to all customers in the distribution network at the minimum possible cost for the system operator, while minimizing the non supplied energy cost. To illustrate the application of the proposed methodology, the paper includes a case study which considers an 33 bus distribution network.