53 resultados para solid sampling technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many solid tumors have a poor response to systemic chemotherapy, local radiotherapy or surgical recession. They are responsible for premature morbidity and decreased patient survival. The radiofrequency ablation is an emerging technique, and is now becoming more widespread throughout the world because it is minimally invasive, image guided, which offers the possibility of an effective and less costly approach. The procedure can be performed percutaneously, guided by several imaging modalities as Ultrasound, Computed Tomography and Magnetic Resonance. This article pretends to demonstrate the state-of-the-art of this technique focusing in the technical aspects and application of radiofrequency ablation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a methodology to address reactive power compensation using Evolutionary Particle Swarm Optimization (EPSO) technique programmed in the MATLAB environment. The main objective is to find the best operation point minimizing power losses with reactive power compensation, subjected to all operational constraints, namely full AC power flow equations, active and reactive power generation constraints. The methodology has been tested with the IEEE 14 bus test system demonstrating the ability and effectiveness of the proposed approach to handle the reactive power compensation problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new and efficient methodology for distribution network reconfiguration integrated with optimal power flow (OPF) based on a Benders decomposition approach. The objective minimizes power losses, balancing load among feeders and subject to constraints: capacity limit of branches, minimum and maximum power limits of substations or distributed generators, minimum deviation of bus voltages and radial optimal operation of networks. The Generalized Benders decomposition algorithm is applied to solve the problem. The formulation can be embedded under two stages; the first one is the Master problem and is formulated as a mixed integer non-linear programming problem. This stage determines the radial topology of the distribution network. The second stage is the Slave problem and is formulated as a non-linear programming problem. This stage is used to determine the feasibility of the Master problem solution by means of an OPF and provides information to formulate the linear Benders cuts that connect both problems. The model is programmed in GAMS. The effectiveness of the proposal is demonstrated through two examples extracted from the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multiresidue gas chromatographic method for the determination of six fungicides (captan, chlorthalonil, folpet, iprodione, procymidone and vinclozolin) and one acaricide (dicofol) in still and fortified wines was developed. Solid-phase microextraction (SPME) was chosen for the extraction of the compounds from the studied matrices and tandem mass spectrometry (MS/MS) detection was used. The extraction consists in a solvent free and automated procedure and the detection is highly sensitive and selective. Good linearity was obtained with correlation coefficients of regression (R2) > 0.99 for all the compounds. Satisfactory results of repeatability and intermediate precision were obtained for most of the analytes (RSD < 20%). Recoveries from spiked wine ranged from 80.1% to 112.0%. Limits of quantification (LOQs) were considerably below the proposedmaximumresidue limits (MRLs) for these compounds in grapes and below the suggested limits for wine (MRLs/10), with the exception of captan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química. Ramo Tecnologias de Protecção Ambiental.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Da crescente necessidade de alimentos e da necessidade de travar a destruição de culturas por animais e insectos foram sintetizados os pesticidas. Por entre uma vasta gama de pesticidas alguns são desreguladores endócrinos o que se traduz num perigo para a saúde humana pois pode despoletar alterações nos seres vivos mesmo em concentrações muito baixas. Devido a diversos factores nomeadamente a lixiviação, ventos e outros agentes ambientais assim como a presença de terrenos agrícolas junto a diversos rios, estes encontram-se contaminados com pesticidas desreguladores endócrinos. O objectivo deste trabalho foi avaliar quais os pesticidas desreguladores endócrinos presentes nas águas de rios da região Norte. Neste trabalho utilizou-se a técnica de microextracção em fase sólida recorrendo a uma fibra de PDMS (100 μm). Para tal as condições de optimização foram testadas nomeadamente a quantidade de NaCl, quantidade de metanol, temperatura do injector e tempo de exposição. Os parâmetros obtidos óptimos foram 0 % de NaCl, tempo de exposição de 45 min, temperatura do injector de 260 ºC e 2,5 % de metanol. Conseguiu-se a separação de todos os pesticidas desreguladores endócrinos com a seguinte programação temperaturas: inicio a 60ºC por um minuto seguido de um aumento de 20 °C/min até aos 200 °C onde permanece por um minuto e de seguida um aumento de 5 °C/min até aos 245 °C onde permanece por 40 min. Fizeram-se curvas de calibração entre 0,01 μg/L e 10 μg/L. Constatou-se no entanto uma falta de reprodutibilidade entre as injecções utilizando esta técnica. Os rios analisados foram o Rio Douro, Rio Tâmega, Ria de Aveiro, Rio Lima, Rio Minho, Rio Sousa, Rio Águeda, Rio Cávado e Rio Leça. No Rio Tâmega foram encontrados os seguintes pesticidas: diazinão, α-HCH, β-HCH, δ-HCH, lindano, HCB, simazina/ atrazina, vinclozolina, alacloro, 2,4-D, malatião, aldrina, bifentrina, metoxicloro e fenvalerato. No rio Douro estão presentes HCB, simazina/ atrazina, vinclozolina, 2,4-D, malatião, aldrina, fenvalerato e deltametrina. No rio Lima encontra-se diazinão, α-HCH, δ-HCH, 2,4-D, HCB, vinclozolina, lindano, simazina/atrazina, alacloro, malatião, aldrina, fenvalerato e deltametrina. No rio Sousa os pesticidas encontrados foram: diazinão, HCB, aldrina, α-HCH, β-HCH, δ-HCH, lindano, simazina/ atrazina, 2,4-D, cipermetrina, alacloro, fenvalerato e malatião. No rio Cávado estão presentes o diazinão, α-HCH, β-HCH, δ-HCH, lindano, HCB, 2,4-D, malatião, metoxicloro, cipermetrina e o fenvalerato. Na ria de Aveiro encontrou-se o diazinão, α-HCH, β-HCH, δ-HCH, lindano, HCB, simazina/atrazina, 2,4-D, Malatião e aldrina. No rio Águeda estão presentes o diazinão, HCB, 2,4-D, aldrina e malatião. E por último no rio Leça esta presente o diazinão, 2,4-D, alacloro, malatião, aldrina, cipermetrina e fenvalerato. A importância deste trabalho reside na demonstração da presença destes pesticidas, desreguladores endócrinos nas águas superficiais da região Norte.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A procura de piscinas para a prática de atividades desportivas, recreativas e/ou terapêuticas tem sofrido um aumento gradual ao longo do tempo. No entanto, nas piscinas existem vários perigos associados à sua utilização. Relativamente aos perigos químicos, a utilização de desinfetantes à base de cloro, bromo ou compostos derivados vai, por um lado, inativar microrganismos patogénicos mas, por outro, dar origem a subprodutos ao reagir com compostos orgânicos presentes na água. Os trihalometanos são um exemplo de subprodutos que se podem formar e, entre os compostos principais, estão o clorofórmio (TCM), bromodiclorometano (BDCM), clorodibromometano (CDBM) e bromofórmio (TBM). Este trabalho teve como objetivo o desenvolvimento de uma metodologia analítica para a determinação de trihalometanos em água e ar de piscinas e a sua aplicação a um conjunto de amostras. Para a análise dos compostos, foi utilizada a microextração em fase sólida no espaço de cabeça (HS-SPME) com posterior quantificação dos compostos por cromatografia gasosa com detetor de captura eletrónica (GC-ECD). Foi realizada uma otimização das condições de extração dos compostos em estudo em amostras de água, através da realização de dois planeamentos experimentais. As condições ótimas são assim obtidas para uma temperatura de extração de 45ºC, um tempo de extração de 25 min e um tempo de dessorção de 5 min. Foram analisadas amostras de águas de piscina cedidas pelo Centro de Estudos de Águas, sendo avaliada a aplicação da técnica HS-SPME e o efeito de matriz. O modo como se manuseiam as soluções que contêm os compostos em estudo influencia os resultados devido ao facto destes serem bastante voláteis. Concluiu-se também que existe efeito de matriz, logo a concentração das amostras deverá ser determinada através do método de adição de padrão. A caraterização da água de piscinas interiores permitiu conhecer a concentração de trihalometanos (THMs). Foram obtidas concentrações de TCM entre 4,5 e 406,5 μg/L sendo que apenas 4 das 27 amostras analisadas ultrapassam o valor limite imposto pelo Decreto-Lei nº306/2007 (100 μg/L) no que diz respeito a águas de consumo humano e que é normalmente utilizado como valor indicativo para a qualidade das águas de piscina. Relativamente à concentração obtida no ar de uma piscina interior, foi detetada uma concentração média de 224 μg/m3 de TCM, valor muito abaixo dos 10000 μg/m3 impostos pelo Decreto-lei nº24/2012, como valor limite para exposição profissional a agentes químicos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hoje em dia algumas das principais preocupações que se tem na exploração a céu aberto, são a diminuição de custos e a máxima rentabilidade dos equipamentos. São dois aspectos que estão interligados uma vez que a rentabilização dos equipamentos tem como resultado directo a diminuição dos custos de todas as operações inerentes à exploração a céu aberto e, consequentemente, a diminuição dos custos finais de produção. É por essa lógica de pensamento que se procurou perceber e compreender o funcionamento e a rentabilidade dos equipamentos em função dos diferentes estados de fracturação do maciço rochoso. Este estudo foi realizado numa pedreira a norte de Portugal e complementa outros estudos já realizados, com o objectivo de definir características do diagrama de fogo que assegurem a maior rentabilidade da referida exploração. O estudo baseia-se em determinar os rendimentos da pá carregadora calculando os tempos de ciclo, isto é, o tempo que a pá demorou a carregar, a movimentar e a descarregar o material desmontado dos vários rebentamentos. Calculou-se o rendimento do martelo demolidor na fragmentação de grandes blocos, que não entrariam directamente no britador primário, o qual também foi alvo de estudo, nomeadamente, no que diz respeito aos tempos de encravamento e de britagem, onde se tentou correlacionar esses tempos com os vários desmontes e estimou-se o consumo de energia do britador primário utilizando a equação de Bond. Por fim, realizou-se um estudo comparativo do consumo energético entre as várias fases da exploração a céu aberto. Foram realizados levantamentos geológico-geotécnicos de superfícies de descontinuidades recorrendo à técnica de amostragem linear nas superfícies do maciço rochoso para perceber o tipo de fragmentação e orientação do mesmo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An Electrocardiogram (ECG) monitoring system deals with several challenges related with noise sources. The main goal of this text was the study of Adaptive Signal Processing Algorithms for ECG noise reduction when applied to real signals. This document presents an adaptive ltering technique based on Least Mean Square (LMS) algorithm to remove the artefacts caused by electromyography (EMG) and power line noise into ECG signal. For this experiments it was used real noise signals, mainly to observe the di erence between real noise and simulated noise sources. It was obtained very good results due to the ability of noise removing that can be reached with this technique. A recolha de sinais electrocardiogr a cos (ECG) sofre de diversos problemas relacionados com ru dos. O objectivo deste trabalho foi o estudo de algoritmos adaptativos para processamento digital de sinal, para redu c~ao de ru do em sinais ECG reais. Este texto apresenta uma t ecnica de redu c~ao de ru do baseada no algoritmo Least Mean Square (LMS) para remo c~ao de ru dos causados quer pela actividade muscular (EMG) quer por ru dos causados pela rede de energia el ectrica. Para as experiencias foram utilizados ru dos reais, principalmente para aferir a diferen ca de performance do algoritmo entre os sinais reais e os simulados. Foram conseguidos bons resultados, essencialmente devido as excelentes caracter sticas que esta t ecnica tem para remover ru dos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O aumento da utilização do mercúrio, Hg, tanto para fins industriais como na aplicação de compostos mercuriais na agricultura, originaram um aumento significativo da contaminação ambiental, especialmente das águas e dos alimentos. Foi aprofundado o estudo sobre o mercúrio, nomeadamente as suas principais fontes de emissão, a sua toxicidade, os principais efeitos nos seres humanos, algumas medidas preventivas, os limites máximos que a legislação permite, que no caso das águas analisadas é de 0,001mg/L, os métodos analíticos para a sua determinação e alguns métodos de amostragem, tanto para o mercúrio em águas como em sedimentos. Em Almadén (Espanha), existe uma mina que pode ser considerada como uma das maiores anomalias geoqímica de mercúrio na Terra. Com este trabalho pretendeu-se perceber a possível existência de mercúrio nas águas termais ao longo da zona de falha Penacova-Régua-Verin e avaliar a existência de uma relação entre os níveis de mercúrio e o seu contexto geológico. Neste trabalho, foi desenvolvido um método simples para a determinação dos níveis de mercúrio em águas, utilizando a espectrometria de absorção atómica de fonte contínua de alta resolução acoplado à técnica de vapor frio. O objectivo deste trabalho foi avaliar os níveis de mercúrio existente em algumas águas engarrafadas e termais. Os limites de detecção da técnica utilizada foram 0,0595 μg/L e os de quantificação foram 0,2100 μg/L. Depois de analisadas as amostras verificou-se que os níveis de mercúrio encontrados nas águas eram inferiores ao limite de quantificação da técnica e por isso, não foi possível extrapolar qualquer relação entre os níveis de mercúrio e as alterações do fundo geológico. Como o limite de quantificação é inferior ao limite máximo permitido por lei, pode então dizer-se que todas as águas se encontram abaixo do limite máximo permitido.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper describes a procedure to isolate volatiles from rock-rose (Cistus ladanifer L.) using simultaneous distillation–extraction (SDE). High-value volatile compounds (HVVC) were selected and the influence of the extraction conditions investigated. The effect of the solvent nature and extraction time on SDE efficiency was studied. The best performance was achieved with pentane in 1 h operation. The extraction efficiencies ranged from 65% to 85% and the repeatability varied between 4% and 6% (as a CV%). The C. ladanifer SDE extracts were analysed by headspace solid phase microextraction (HS-SPME) followed by gas chromatography with flame ionization detection (GC-FID). The HS-SPME sampling conditions such as fiber coating, temperature, ionic strength and exposure time were optimized. The best results were achieved with an 85 µm polyacrylate fiber for a 60 min headspace extraction at 40ºC with 20% (w/v) of NaCl. For optimized conditions the recovery was in average higher than 90% for all compounds and the intermediate precision ranged from 4 to 9% (as CV %). The volatiles α-pinene (22.2 mg g−1 of extract), 2,2,6-trimethylcyclohexanone (6.1 mg g−1 of extract), borneol (3.0 mg g−1 of extract) and bornyl acetate (3.9 mg g−1 of extract) were identified in the SDE extracts obtained from the fresh plant material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies were undertaken to determine the adsorption behavior of α-cypermethrin [R)-α-cyano-3-phenoxybenzyl(1S)-cis- 3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropanecarboxylate, and (S)-α-cyano-3-phenoxybenzyl (1R)-cis-3-(2,2-dichlorovinyl)-2,2- dimethylcyclopropanecarboxylate] in solutions on granules of cork and activated carbon (GAC). The adsorption studies were carried out using a batch equilibrium technique. A gas chromatograph with an electron capture detector (GC-ECD) was used to analyze α-cypermethrin after solid phase extraction with C18 disks. Physical properties including real density, pore volume, surface area and pore diameter of cork were evaluated by mercury porosimetry. Characterization of cork particles showed variations thereby indicating the highly heterogeneous structure of the material. The average surface area of cork particles was lower than that of GAC. Kinetics adsorption studies allowed the determination of the equilibrium time—24 hours for both cork (1–2 mm and 3–4 mm) and GAC. For the studied α-cypermethrin concentration range, GAC revealed to be a better sorbent. However, adsorption parameters for equilibrium concentrations, obtained through the Langmuir and Freundlich models, showed that granulated cork 1–2 mm have the maximum amount of adsorbed α-cypermethrin (qm) (303 μg/g); followed by GAC (186 μg/g) and cork 3-4 mm (136 μg/g). The standard deviation (SD) values, demonstrate that Freundlich model better describes the α-cypermethrin adsorption phenomena on GAC, while α-cypermethrin adsorption on cork (1-2 mm and 3-4 mm) is better described by the Langmuir. In view of the adsorption results obtained in this study it appears that granulated cork may be a better and a cheaper alternative to GAC for removing α-cypermethrin from water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p’-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work presented describes the development and evaluation of two flow-injection analysis (FIA) systems for the automated determination of carbaryl in spiked natural waters and commercial formulations. Samples are injected directly into the system where they are subjected to alkaline hydrolysis thus forming 1-naphthol. This product is readily oxidised at a glassy carbon electrode. The electrochemical behaviour of 1-naphthol allows the development of an FIA system with an amperometric detector in which 1-naphthol determination, and thus measurement of carbaryl concentration, can be performed. Linear response over the range 1.0×10–7 to 1.0×10–5 mol L–1, with a sampling rate of 80 samples h–1, was recorded. The detection limit was 1.0×10–8 mol L–1. Another FIA manifold was constructed but this used a colorimetric detector. The methodology was based on the coupling of 1-naphthol with phenylhydrazine hydrochloride to produce a red complex which has maximum absorbance at 495 nm. The response was linear from 1.0×10–5 to 1.5×10–3 mol L–1 with a detection limit of 1.0×10–6 mol L–1. Sample-throughput was about 60 samples h–1. Validation of the results provided by the two FIA methodologies was performed by comparing them with results from a standard HPLC–UV technique. The relative deviation was <5%. Recovery trials were also carried out and the values obtained ranged from 97.0 to 102.0% for both methods. The repeatability (RSD, %) of 12 consecutive injections of one sample was 0.8% and 1.6% for the amperometric and colorimetric systems, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A SPME-GC-MS/MS method for the determination of eight organophosphorus pesticides (azinphos-methyl, chlorpyriphos, chlorpyriphos-methyl, diazinon, fenitrothion, fenthion, malathion, and methidathion) in still and fortified wine was developed. The extraction procedure is simple, solvent free, and without any sample pretreatment. Limits of detection (LOD) and quantitation (LOQ) values in the range 0.1–14.3 lg/L and 0.2–43.3 lg/L, respectively, were obtained. The LOQ values are below the maximum residue levels (MRLs) established by European Regulation for grapes, with the exception of methidathion. Coefficients of correlation (R2) higher than 0.99 were obtained for the majority of the pesticides, in all different wines analyzed.