40 resultados para electrolyte exclusion


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrochemical behavior of citalopram was studied by square-wave and square-wave adsorptive-stripping voltammetry (SWAdSV). Citalopram can be reduced and accumulated at a mercury drop electrode, with a maximum peak current intensity being obtained at a potential of approximately -1.25V vs. AgCl/Ag, in an aqueous electrolyte solution of pH 12. A SWAdSV method has been developed for the determination of citalopram in pharmaceutical preparations. The method shows a linear range between 1.0x10-7 and 2.0x10-6 mol L-1 with a limit of detection of 5x10-8 mol L-1 for an accumulation time of 30 s. The precision of the method was evaluated by assessing the repeatability and intermediate precision, achieving good relative standard deviations in all cases (≤2.3%). The proposed method was applied to the determination of citalopram in five pharmaceutical products and the results obtained are in good agreement with the labeled values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fluvoxamine (FVX) can be reduced at a mercury- drop electrode, with a maximum peak current intensity being obtained at a potential of -0.7 V vs. Ag/ AgCl, in an aqueous electrolyte solution of pH 2. The compound was determined in a pharmaceutical product and in spiked human serum by square-wave adsorptivestripping voltammetry (SWAdSV) after accumulation at the electrode surface, under batch conditions. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was also possible to determine FVX in the pharmaceutical product by use of a flow-injection analysis (FIA) system with SWAdSV detection. The methods developed were validated and successfully applied to the quantification of FVX in a pharmaceutical product. Recoveries between 76 and 89% were obtained in serum analysis. The FIA– SWAdSV method enabled analysis of up to 120 samples per hour at reduced cost, implying the possibility of competing with the chromatographic methods usually used for this analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two analytical methods for the quality control of dihydrocodeine in commercial pharmaceutical formulations have been developed and compared with reference methods: a square wave voltammetric (SWV) method and a flow injection analysis system with electrochemical detection (FIA-EC). The electrochemical methods proposed were successfully applied to the determination of dihydrocodeine in pharmaceutical tablets and in oral solutions. These methods do not require any pretreatment of the samples, the formulation only being dissolved in a suitable electrolyte. Validation of the methods showed it to be precise, accurate and linear over the concentration range of analysis. The automatic procedure based on a flow injection analysis manifold allows a sampling rate of 115 determinations per hour.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An extraction-adsorptive stripping voltammetric procedure for the determination of the pesticide dialifos in soil samples using microwave-assisted solvent extraction and a mercury film ultramicroelectrode was developed. The method is based on the use of hexane-acetone solvent (1:1, v/v) and on controlled adsorptive accumulation of the insecticide at the potential of -0.10V (versus Ag/AgCl) in the presence of Britton-Robinson buffer (pH 2.0). Soil sample extracts were analyzed directly after drying and redissolution with the supporting electrolyte, but without other pretreatment. The limit of detection obtained for a 10sec collection time was 2.0x10-8 mol L-1. Recovery experiments for the global procedure, at the 0.100µgg-1 level, gave satisfactory average and standard deviation results for the two different soils tested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An extraction-anodic adsorptive stripping voltammetric procedure using microwave-assisted solvent extraction and a gold ultramicroelectrode was developed for determining the pesticide ametryn in soil samples. The method is based on the use of acetonitrile as extraction solvent and on controlled adsorptive accumulation of the herbicide at the potential of 0.50 V (vs. Ag/AgCl) in the presence of Britton-Robinson buffer (pH 3.3). Soil sample extracts were analysed directly after drying and redissolution with the supporting electrolyte but without other pre-treatment. The limit of detection obtained for a 10 s collection time was 0.021 µg g-1. Recovery experiments for the global procedure, at the 0.500 µg g-1 level, gave satisfactory mean and standard deviation results which were comparable to those obtained by HPLC with UV detection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrochemical behaviour of the herbicide Asulam was studied by cyclic and square wave voltammetry. Asulam may be irreversibly oxidised at a glassy carbon electrode. Maximum currents were obtained at pH=1.9 in aqueous electrolyte solution. Based on the electrochemical behaviour of Asulam, two analytical methodologies were developed for its determination in water samples, using square wave voltammetry (SWV) and flow injection analysis (FIA) coupled with an amperometric detector. Limits of detection of 7.1x10-6 mol L-1 and 1.2x10-8 mol L-1 for SWV and FIA respectively, were achieved. Repeatability was calculated by assessing the relative standard deviation (%) for 10 consecutive determinations of one sample. The found values were 2.1% for SWV and 5.0% for FIA. Validation of the results provided by SWV and FIA methodologies was performed by comparison with results from an HPLC-DAD technique. Good relative deviations were found (<5%). Recovery trials were performed to assess the accuracy of the results and the obtained values were between 84% and 107% for both methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The remediation of contaminated sites supports the goal of sustainable development but may also have environmental impacts at a local, regional and global scale. Life cycle assessment (LCA) has increasingly been used in order to support site remediation decision-making. This review article discusses existing LCA methods and proposed models focusing on critical decisions and assumptions of the LCA application to site remediation activities. It is concluded that LCA has limitations as an adequate holistic decisionmaking tool since spatial and temporal differentiation of non-global impacts assessment is a major hurdle in site remediation LCA. Moreover, a consequential LCA perspective should be adopted when the different remediation services to be compared generate different site’s physical states, displacing alternative post-remediation scenarios. The environmental effects of the post-remediation stage of the site is generally disregarded in the past site remediation LCA studies and such exclusion may produce misleading conclusions and misdirected decision-making. In addition, clear guidance accepted by all stakeholders on remediation capital equipment exclusion and on dealing with multifunctional processes should be developed for site remediation LCA applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the use of integer and fractional electrical elements, for modelling two electrochemical systems. A first type of system consists of botanical elements and a second type is implemented by electrolyte processes with fractal electrodes. Experimental results are analyzed in the frequency domain, and the pros and cons of adopting fractional-order electrical components for modelling these systems are compared.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The oxidative behaviour of fluoxetine was studied at a glassy carbon electrode in various buffer systems and at different pH using cyclic, differential pulse and square wave voltammetry. A new square wave voltammetric method suitable for the quality control of fluoxetine in commercial formulations has been developed using a borate pH 9 buffer solution as supporting electrolyte. Under optimized conditions, a linear response was obtained in the range 10 to 16 μM with a detection limit of 1.0 μM. Validation parameters such as sensitivity, precision and accuracy were evaluated. The proposed method was successfully applied to the determination of fluoxetine in pharmaceutical formulations. The results were statistically compared with those obtained by the reference high-performance liquid chromatographic method. No significant differences were found between the methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Video poker machines, a former symbol of fraud and gambling in Brazil, are now being converted into computer-based educational tools for Brazilian public primary schools and also for governmental and non-governmental institutions dealing with communities of poverty and social exclusion, in an attempt to reduce poverty risks (decrease money spent on gambling) and promote social inclusion (increase access and motivation to education). Thousands of illegal gambling machines are seized by federal authorities, in Brazil, every year, and usually destroyed at the end of the criminal apprehension process. This paper describes a project developed by the University of Southern Santa Catarina, Brazil, responsible for the conversion process of gambling machines, and the social inclusion opportunities derived from it. All project members worked on a volunteer basis, seeking to promote social inclusion of Brazilian young boys and girls, namely through digital inclusion. So far, the project has been able to convert over 200 gambling machines and install them in over 40 public primary schools, thus directly benefiting more than 12,000 schoolchildren. The initial motivation behind this project was technology based, however the different options arising from the conversion process of the gambling machines have also motivated a rather innovative and unique experience in allowing schoolchildren and young people with special (educational) needs to access to computer-based pedagogical applications. The availability of these converted machines also helps to place Information and Communication Technologies (ICT) in the very daily educational environment of these children and youngsters, thus serving social and cultural inclusion aspects, by establishing a dialogue with the community and their technological expectations, and also directly contributing to their digital literacy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de Mestrado apresentada ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Contabilidade e Finanças sob orientação de: Amélia Ferreira da Silva “Esta versão contém as críticas e sugestões dos elementos do júri”

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: Os exercícios de fortalecimento dos músculos do pavimento pélvico (EFMPP) são considerados a primeira intervenção no tratamento da incontinência urinária de esforço (IUE), porém os EFMPP são distintos, não existindo evidência sobre os parâmetros de treino. Objetivo: Identificar o protocolo e/ ou os parâmetros de treino dos músculos do pavimento pélvico (MPP) mais eficaz no tratamento da IUE feminina. Método: A pesquisa bibliográfica foi realizada entre janeiro de 1992 a março de 2014 nas bases de dados PubMed, Cochrane Library, PEDro, web of Science e LILACS. Os artigos incluídos eram de língua inglesa, estudos experimentais, no qual comparavam EFMPP com o tratamento placebo, usual ou sem tratamento, com idade compreendida entre os 18 e os 65 anos e diagnóstico de IUE. Os critérios de exclusão abrangeram o diagnóstico de IUE desencadeada por fatores externos ao trato urinário inferior, grávidas, puérperas, prolapso ≥ 2 e outros tipos de IU. A avaliação da qualidade metodológica for realizada através da escala PEDro. Resultados: Sete artigos de elevada qualidade metodológica foram incluídos na presente revisão. A amostra foi constituída por 331 mulheres, com idade média de 44,4 anos, duração média das perdas urinárias de 64 meses e a gravidade da IUE variou entre ligeira a severa. Os programas de EFMPP eram distintos em relação aos parâmetros de treino dos MPP, sendo que alguns estudos incluíram o treino abdominal, supervisão e técnicas adjuvantes. A taxa de curada da quantidade de perda urinária variou entre 28,6 a 80%, enquanto a força dos MPP variou de 15,6% a 161,7%. Conclusão: Na presente revisão sistemática, os EFMPP combinados com palpação digital, biofeedback e cones vaginais parecem ser mais eficazes na redução da quantidade de perda urinária, comparado com os EFMPP isolados ou sem tratamento. Esta revisão permitiu igualmente identificar as 12 semanas de duração da intervenção, 10 repetições por série e diferentes posições, sendo os parâmetros de treino mais consistentes na redução dos sintomas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: Os exercícios de fortalecimento dos músculos do pavimento pélvico (EFMPP) são considerados a primeira intervenção no tratamento da incontinência urinária de esforço (IUE), porém os EFMPP são distintos, não existindo evidência sobre os parâmetros de treino. Objetivo: Identificar o protocolo e/ ou os parâmetros de treino dos músculos do pavimento pélvico (MPP) mais eficaz no tratamento da IUE feminina. Método: A pesquisa bibliográfica foi realizada entre janeiro de 1992 a março de 2014 nas bases de dados PubMed, Cochrane Library, PEDro, web of Science e LILACS. Os artigos incluídos eram de língua inglesa, estudos experimentais, no qual comparavam EFMPP com o tratamento placebo, usual ou sem tratamento, com idade compreendida entre os 18 e os 65 anos e diagnóstico de IUE. Os critérios de exclusão abrangeram o diagnóstico de IUE desencadeada por fatores externos ao trato urinário inferior, grávidas, puérperas, prolapso ≥ 2 e outros tipos de IU. A avaliação da qualidade metodológica for realizada através da escala PEDro. Resultados: Sete artigos de elevada qualidade metodológica foram incluídos na presente revisão. A amostra foi constituída por 331 mulheres, com idade média de 44,4 anos, duração média das perdas urinárias de 64 meses e a gravidade da IUE variou entre ligeira a severa. Os programas de EFMPP eram distintos em relação aos parâmetros de treino dos MPP, sendo que alguns estudos incluíram o treino abdominal, supervisão e técnicas adjuvantes. A taxa de curada da quantidade de perda urinária variou entre 28,6 a 80%, enquanto a força dos MPP variou de 15,6% a 161,7%. Conclusão: Na presente revisão sistemática, os EFMPP combinados com palpação digital, biofeedback e cones vaginais parecem ser mais eficazes na redução da quantidade de perda urinária, comparado com os EFMPP isolados ou sem tratamento. Esta revisão permitiu igualmente identificar as 12 semanas de duração da intervenção, 10 repetições por série e diferentes posições, sendo os parâmetros de treino mais consistentes na redução dos sintomas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Optically transparent cocatalyst film materials is very desirable for improved photoelectrochemical (PEC)oxygen evolution reaction (OER) over light harvesting photoelectrodes which require the exciting light to irradiate through the cocatalyst side, i.e., front-side illumination. In view of the reaction overpotential at electrode/electrolyte interface, the OER electrocatalysts have been extensively used as cocatalysts for PEC water oxidation on photoanode. In this work, the feasibility of a one-step fabrication of the transparent thin film catalyst for efficient electrochemical OER is investigated. The Ni-Fe bimetal oxide films, 200 nm in thickness, are used for study. Using a reactive magnetron co-sputtering technique, transparent(> 50% in wavelength range 500-2000 nm) Ni-Fe oxide films with high electrocatalytic activities were successfully prepared at room temperature. Upon optimization, the as-prepared bimetal oxide film with atomic ratio of Fe/Ni = 3:7 demonstrates the lowest overpotential for the OER in aqueous KOH solution, as low as 329 mV at current density of 2 mA cm 2, which is 135 and 108 mV lower than that of as-sputtered FeOx and NiOx thin films, respectively. It appears that this fabrication strategy is very promising to deposit optically transparent cocatalyst films on photoabsorbers for efficient PEC water splitting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The most effective therapeutic option for managing nonmuscle invasive bladder cancer (NMIBC), over the last 30 years, consists of intravesical instillations with the attenuated strain Bacillus Calmette-Gu´erin (the BCG vaccine). This has been performed as an adjuvant therapeutic to transurethral resection of bladder tumour (TURBT) and mostly directed towards patients with highgrade tumours, T1 tumours, and in situ carcinomas. However, from 20% to 40% of the patients do not respond and frequently present tumour progression. Since BCG effectiveness is unpredictable, it is important to find consistent biomarkers that can aid either in the prediction of the outcome and/or side effects development. Accordingly, we conducted a systematic critical review to identify themost preeminent predictive molecular markers associated with BCG response. To the best of our knowledge, this is the first review exclusively focusing on predictive biomarkers for BCG treatment outcome. Using a specific query, 1324 abstracts were gathered, then inclusion/exclusion criteria were applied, and finally 87 manuscripts were included. Several molecules, including CD68 and genetic polymorphisms, have been identified as promising surrogate biomarkers. Combinatory analysis of the candidate predictive markers is a crucial step to create a predictive profile of treatment response.