55 resultados para activity, detection, monitoring, wearable, sensors, accelerometer


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective Public health organizations recommend that preschool-aged children accumulate at least 3 h of physical activity (PA) daily. Objective monitoring using pedometers offers an opportunity to measure preschooler's PA and assess compliance with this recommendation. The purpose of this study was to derive step-based recommendations consistent with the 3 h PA recommendation for preschool-aged children. Method The study sample comprised 916 preschool-aged children, aged 3 to 6 years (mean age = 5.0 ± 0.8 years). Children were recruited from kindergartens located in Portugal, between 2009 and 2013. Children wore an ActiGraph GT1M accelerometer that measured PA intensity and steps per day simultaneously over a 7-day monitoring period. Receiver operating characteristic (ROC) curve analysis was used to identify the daily step count threshold associated with meeting the daily 3 hour PA recommendation. Results A significant correlation was observed between minutes of total PA and steps per day (r = 0.76, p < 0.001). The optimal step count for ≥ 3 h of total PA was 9099 steps per day (sensitivity (90%) and specificity (66%)) with area under the ROC curve = 0.86 (95% CI: 0.84 to 0.88). Conclusion Preschool-aged children who accumulate less than 9000 steps per day may be considered Insufficiently Active.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Environmental pollution continues to be an emerging study field, as there are thousands of anthropogenic compounds mixed in the environment whose possible mechanisms of toxicity and physiological outcomes are of great concern. Developing methods to access and prioritize the screening of these compounds at trace levels in order to support regulatory efforts is, therefore, very important. A methodology based on solid phase extraction followed by derivatization and gas chromatography-mass spectrometry analysis was developed for the assessment of four endocrine disrupting compounds (EDCs) in water matrices: bisphenol A, estrone, 17b-estradiol and 17a-ethinylestradiol. The study was performed, simultaneously, by two different laboratories in order to evaluate the robustness of the method and to increase the quality control over its application in routine analysis. Validation was done according to the International Conference on Harmonisation recommendations and other international guidelines with specifications for the GC-MS methodology. Matrix-induced chromatographic response enhancement was avoided by using matrix-standard calibration solutions and heteroscedasticity has been overtaken by a weighted least squares linear regression model application. Consistent evaluation of key analytical parameters such as extraction efficiency, sensitivity, specificity, linearity, limits of detection and quantification, precision, accuracy and robustness was done in accordance with standards established for acceptance. Finally, the application of the optimized method in the assessment of the selected analytes in environmental samples suggested that it is an expedite methodology for routine analysis of EDC residues in water matrices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Os serviços baseados em localização vieram dar um novo alento à criatividade dos programadores de aplicações móveis. A vulgarização de dispositivos com capacidades de localização integradas deu origem ao desenvolvimento de aplicações que gerem e apresentam informação baseada na posição do utilizador. Desde então, o mercado móvel tem assistido ao aparecimento de novas categorias de aplicações que tiram proveito desta capacidade. Entre elas, destaca-se a monitorização remota de dispositivos, que tem vindo a assumir uma importância crescente, tanto no sector particular como no sector empresarial. Esta dissertação começa por apresentar o estado da arte sobre os diferentes sistemas de posicionamento, categorizados pela sua eficácia em ambientes internos ou externos, assim como diferentes protocolos de comunicação em tempo quase-real. É também feita uma análise ao estado actual do mercado móvel. Actualmente o mercado possui diferentes plataformas móveis com características únicas que as fazem rivalizar entre si, com vista a expandirem a sua quota de mercado. É por isso elaborado um breve estudo sobre os sistemas operativos móveis mais relevantes da actualidade. É igualmente feita uma abordagem mais profunda à arquitectura da plataforma móvel da Apple - o iOS – que serviu de base ao desenvolvimento de uma solução optimizada para localização e monitorização de dispositivos móveis. A monitorização implica uma utilização intensiva de recursos energéticos e de largura de banda que os dispositivos móveis da actualidade não estão aptos a suportar. Dado o grande consumo energético do GPS face à precária autonomia destes dispositivos, é apresentado um estudo em que se expõem soluções que permitem gerir de forma optimizada a utilização do GPS. O elevado custo dos planos de dados facultados pelas operadoras móveis é também considerado, pelo que são exploradas soluções que visam minimizar a utilização de largura de banda. Deste trabalho, nasce a aplicação EyeGotcha, que para além de permitir localizar outros utilizadores de dispositivos móveis de forma optimizada, permite também monitorizar as suas acções baseando-se num conjunto de regras pré-definidas. Estas acções são reportadas às entidades monitoras, de modo automatizado e sob a forma de alertas. Visionando-se a comercialização da aplicação, é portanto apresentado um modelo de negócio que permite obter receitas capazes de cobrirem os custos de manutenção de serviços, aos quais o funcionamento da aplicação móvel está subjugado.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Esta tese descreve o desenvolvimento do hardware e do software de um sistema com a capacidade de reconhecer o número de passos que uma pessoa efectua durante uma actividade física. O sistema consiste num acelerómetro controlado por um microcontrolador, que comunica com um dispositivo móvel através de Bluetooth. De modo a realizar o sistema foi necessário analisar uma vasta bibliografia, para conhecer o estado da arte desta tecnologia, entender o princípio de funcionamento do protocolo Bluetooth e os conceitos biomecânicos por detrás da marcha humana. A proposta deste trabalho apresentava como elemento diferenciador do estado da arte o uso de um acelerómetro em conjunto com sensores de pressão. Com a conjugação destes sensores pretendia-se aumentar a precisão de um equipamento que normalmente não é reconhecido por essa característica. Contudo, a indisponibilidade dos sensores de pressão levou a que o sistema só fosse constituído pelo acelerómetro. Embora, o sistema foi projectado considerando que os sensores de pressão serão incluídos num futuro desenvolvimento. Neste trabalho foram desenvolvidos dois algoritmos para detectar os passos que uma pessoa executa, com pé onde é colocado o sensor, quando caminha ou corre. Num dos testes realizados o algoritmo da “aceleração composta” detectou 84% dos passos, enquanto o algoritmo da “aceleração simples”detectou 99%. A plataforma para a interface gráfica pretendia-se que fosse um telemóvel, contudo não foi possível obter um telemóvel que suporta-se o perfil SPP (Serial Port Profile), necessário para a comunicação com o módulo Bluetooth usado. A solução passou por usar como plataforma um computador portátil com Bluetooth, para o qual foi desenvolvido a aplicação “Pedómetro ISEP” em Visual Basic. O “Pedómetro ISEP” apresenta várias funcionalidades, entre elas destaca-se o cálculo da distância percorrida, da velocidade, e das calorias consumidas, bem como, o registo desses valores em tabelas e da possibilidade de desenhar os gráficos representativos do progresso do utilizador.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A gestão de redes informáticas converteu-se num fator vital para uma rede operar de forma eficiente, produtiva e lucrativa. A gestão envolve a monitorização e o controlo dos sistemas para que estes funcionam como o pretendido, ações de configuração, monitorização, reconfiguração dos componentes, são essenciais para o objetivo de melhorar o desempenho, diminuir o tempo de inatividade, melhor a segurança e efetuar contabilização. Paralelamente, a classificação de tráfego é um tema de bastante relevância em várias atividades relacionadas com as redes, tais como a previsão de QoS, segurança, monitorização, contabilização, planeamento de capacidade de backbones e deteção de invasão. A variação de determinados tipos de tráfego pode influenciar decisões técnicas na área da gestão de redes, assim como decisões políticas e sociais. Neste trabalho pretende-se desenvolver um estudo dos vários protocolos, ferramentas de gestão e de classificação de tráfego disponíveis para apoiar a atividade de gestão. O estudo efetuado terminou com a proposta e implementação de uma solução de gestão adequado a um cenário real bastante rico na diversidade de tecnologias e sistemas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new fluorescent sensor for nitric oxide (NO) is presented that is based on its reaction with a non fluorescent substance, reduced fluoresceinamine, producing the highly fluorescent fluoresceinamine. Using a portable homemade stabilized light source consisting of 450 nm LED and fiber optics to guide the light, the sensor responds linearly within seconds in the NO concentration range between about 10–750 µM with a limit of detection (LOD) of about 1 µM. The system generated precise intensity readings, with a relative standard deviation of less than 1%. The suitability of the sensor was assessed by monitoring the NO generated by either the nitrous acid decomposition reaction or from a NO-releasing compound. Using relatively high incubation times, the sensor also responds quantitatively to hydrogen peroxide and potassium superoxide, however, using transient signal measurements results in no interfering species.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

New PVC membrane electrodes for the determination of sulfadiazine (SDZ) are presented. The electrodes are fabricated with conventional and tubular configurations with a graphite-based electrical contact, and no internal reference solution. The selective membranes consist of bis(triphenylphosphoranilidene)ammonium·SDZ (electrode A), tetraoctylammonium bromide (electrode B), or iron(II)-phthalocyanine (FePC) (electrode C) electroactive materials dispersed in a PVC matrix of o-nitrophenyl octyl ether (o-NPOE) plasticizer. The sensors A, B, and C displayed linear responses over the concentration ranges 1.0*10-2 – 1.0*10–5, 1.0*10–2 – 7.5*10–6, and 3.2*10–2 – 7.0* 10–6 mol l–1 (detection limits of 1.09, 2.04 and 0.87 mg ml–1) with anionic slopes of –57.3 ± 0.1, –46.7 ± 0.5, and –65.1 ± 0.2 mV decade–1, respectively. No effect from pH was observed within 4.0 – 5.5, 4.8 – 10, and 4.5 – 8, respectively, and good selectivity was found. The sensors were applied to the analysis of pharmaceuticals and biological fluids in steady state and in flow conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

New potentiometric membrane sensors with cylindrical configuration for tetracycline (TC) are described based on the use of a newly designed molecularly imprinted polymer (MIP) material consisting of 2-vinylpyridine as a functional monomer in a plasticized PVC membrane. The sensor exhibited significantly enhanced response towards TC over the concentration range 1.59 10 5–1.0 10 3 mol L 1 at pH 3–5 with a lower detection limit of 1.29 10 5 mol L 1. The response was near-Nernstian, with average slopes of 63.9 mV decade 1. The effect of lipophilic salts and various foreign common ions were tested and were found to be negligible. The possibility of applying the proposed sensor to TC determination in spiked biological fluid samples was demonstrated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The electrooxidative behavior of citalopram (CTL) in aqueous media was studied by cyclic voltammetry (CV) and square-wave voltammetry (SWV) at a glassy-carbon electrode. The electrochemical behaviour of CTL involves two electrons and two protons in the irreversible and diffusion controlled oxidation of the tertiary amine group. The maximum analytical signal was obtained in a phosphate buffer (pH ¼ 8.2). For analytical purposes, an SWV method and a flow-injection analysis (FIA) system with amperometric detection were developed. The optimised SWV method showed a linear range between 1.10 10 5–1.20 10 4 molL 1, with a limit of detection (LOD) of 9.5 10 6 molL 1. Using the FIA method, a linear range between 2.00 10 6–9.00 10 5 molL 1 and an LODof 1.9 10 6 molL 1 were obtained. The validation of both methods revealed good performance characteristics confirming applicability for the quantification of CTL in several pharmaceutical products.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Molecularly imprinted polymers (MIP) were used as potentiometric sensors for the selective recognition and determination of chlormequat (CMQ). They were produced after radical polymerization of 4-vinyl pyridine (4-VP) or methacrylic acid (MAA) monomers in the presence of a cross-linker. CMQwas used as template. Similar nonimprinted (NI) polymers (NIP) were produced by removing the template from reaction media. The effect of kind and amount of MIP or NIP sensors on the potentiometric behavior was investigated. Main analytical features were evaluated in steady and flow modes of operation. The sensor MIP/4-VP exhibited the best performance, presenting fast near-Nernstian response for CMQover the concentration range 6.2×10-6 – 1.0×10-2 mol L-1 with detection limits of 4.1×10-6 mol L-1. The sensor was independent from the pH of test solutions in the range 5 – 10. Potentiometric selectivity coefficients of the proposed sensors were evaluated over several inorganic and organic cations. Results pointed out a good selectivity to CMQ. The sensor was applied to the potentiometric determination of CMQin commercial phytopharmaceuticals and spiked water samples. Recoveries ranged 96 to 108.5%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To counteract and prevent the deleterious effect of free radicals the living organisms have developed complex endogenous and exogenous antioxidant systems. Several analytical methodologies have been proposed in order to quantify antioxidants in food, beverages and biological fluids. This paper revises the electroanalytical approaches developed for the assessment of the total or individual antioxidant capacity. Four electrochemical sensing approaches have been identified, based on the direct electrochemical detection of antioxidant at bare or chemically modified electrodes, and using enzymatic and DNA-based biosensors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ochratoxin A (OTA) is a mycotoxin produced by a variety of fungi, such as Penicillium verrucosum and Aspergillium spp., which has been found to have a wide number of potentially deadly toxic effects, and can enter the human organism through a variety of means. It then finds its way into the bloodstream and, after a lengthy process, is eventually excreted through the urine. It can thus be detected in its original form not only in blood samples but also in this biological medium. As such, and in an attempt to evaluate the exposure of the Portuguese population to this mycotoxin, morning urine samples were collected during the Winter of 2007, from each of five geographically distinct Portuguese locations — Bragança, Porto, Coimbra, Alentejo, and Algarve — and subjected to extraction by immunoaffinity columns and to OTA quantification through liquid chromatography coupled with fluorescence detection. Prevalent incidence was higher than 95% with Coimbra being the exception (incidence of 73.3%). In nearly all locations, the OTA content of most samples was found to be above the limit of quantification (LOQ) of 0.008 ng/ml. Indeed, excluding Coimbra, with an OTA content level of 0.014 ng/ml, all regions featured content values over 0.021 ng/ml.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ibuprofen is amongst the most worldwide consumed pharmaceuticals. The present work presents the first data in the occurrence of ibuprofen in Portuguese surface waters, focusing in the north area of the country, which is one of the most densely populated areas of Portugal. Analysis of ibuprofen is based on pre-concentration of the analyte with solid phase extraction and subsequent determination with liquid chromatography coupled to fluorescence detection. A total of 42 water samples, including surface waters, landfill leachates,Wastewater Treatment Plant (WWTP), and hospital effluents, were analyzed in order to evaluate the occurrence of ibuprofen in the north of Portugal. In general, the highest concentrations were found in the river mouths and in the estuarine zone. The maximum concentrations found were 48,720 ngL−1 in the landfill leachate, 3,868 ngL−1 in hospital effluent, 616 ngL−1 in WWTP effluent, and 723 ngL−1 in surface waters (Lima river). Environmental risk assessment was evaluated and at the measured concentrations only landfill leachates reveal potential ecotoxicological risk for aquatic organisms. Owing to a high consumption rate of ibuprofen among Portuguese population, as prescribed and nonprescribed medicine, the importance of hospitals, WWTPs, and landfills as sources of entrance of pharmaceuticals in the environment was pointed out. Landfill leachates showed the highest contribution for ibuprofen mass loading into surface waters. On the basis of our findings, more studies are needed as an attempt to assess more vulnerable areas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Celiac disease (CD) is a gluten-induced autoimmune enteropathy characterized by the presence of antibodies against gliadin (AGA) and anti-tissue transglutaminase (anti-tTG) antibodies. A disposable electrochemical dual immunosensor for the simultaneous detection of IgA and IgG type AGA and antitTG antibodies in real patient’s samples is presented. The proposed immunosensor is based on a dual screen-printed carbon electrode, with two working electrodes, nanostructured with a carbon–metal hybrid system that worked as the transducer surface. The immunosensing strategy consisted of the immobilization of gliadin and tTG (i.e. CD specific antigens) on the nanostructured electrode surface. The electrochemical detection of the human antibodies present in the assayed serum samples was carried out through the antigen–antibody interaction and recorded using alkaline phosphatase labelled anti-human antibodies and a mixture of 3-indoxyl phosphate with silver ions was used as the substrate. The analytical signal was based on the anodic redissolution of enzymatically generated silver by cyclic voltammetry. The results obtained were corroborated with commercial ELISA kits indicating that the developed sensor can be a good alternative to the traditional methods allowing a decentralization of the analyses towards a point-of-care strategy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atualmente, as radiações ionizantes desempenham um papel fundamental nas áreas de diagnóstico e terapia, estando omnipresentes em ambientes hospitalares. Contudo, devido aos efeitos biológicos adversos da radiação, torna-se essencial a protecção dos profissionais de saúde e pacientes. Consequentemente, um array de detetores capazes de produzir um sinal acústico, aquando da presença de radiação ionizante excedendo determinados valores limite e transmissão via wireless das leituras para um sistema central _e de grande interesse prático. Nesta dissertação, foi implementado um sistema capaz de alimentar um array de sensores de radiação para monitorização de diferentes espaços e transmissão das leituras efetuadas via wireless. A aquisição de dados foi realizada, recorrendo à utilização de um conversor analógico-digital. Vários testes de validação foram realizados, através de vários passos para alcançar a concretização do sistema final, nomeadamente testes relativos ao circuito de detecção, módulos de comunicação wireless, bem como o uso de diferentes ambientes de desenvolvimento integrados (IDE). Os resultados destes testes mostram a visualização e gravação adequadas dos dados relativos aos níveis de radiação, bem como a transmissão de dados de forma viável, permitindo a monitorização de espaços sujeitos à presença de radiação ionizante. Desta forma, um array de contadores Geiger-Müller, ligados a módulos wireless XBee open-source e uma placa Arduino, possibilitou a implementação de um sistema viável e de baixo custo para monitorização de radiação ionizante e registar esses mesmos dados para posterior análise.