22 resultados para URBAN HEAT-ISLAND
Resumo:
The aim of this work was to assess the influence of meteorological conditions on the dispersion of particulate matter from an industrial zone into urban and suburban areas. The particulate matter concentration was related to the most important meteorological variables such as wind direction, velocity and frequency. A coal-fired power plant was considered to be the main emission source with two stacks of 225 m height. A middle point between the two stacks was taken as the centre of two concentric circles with 6 and 20 km radius delimiting the sampling area. About 40 sampling collectors were placed within this area. Meteorological data was obtained from a portable meteorological station placed at approximately 1.7 km to SE from the stacks. Additional data was obtained from the electrical company that runs the coal power plant. These data covers the years from 2006 to the present. A detailed statistical analysis was performed to identify the most frequent meteorological conditions concerning mainly wind speed and direction. This analysis revealed that the most frequent wind blows from Northwest and North and the strongest winds blow from Northwest. Particulate matter deposition was obtained in two sampling campaigns carried out in summer and in spring. For the first campaign the monthly average flux deposition was 1.90 g/m2 and for the second campaign this value was 0.79 g/m2. Wind dispersion occurred predominantly from North to South, away from the nearest residential area, located at about 6 km to Northwest from the stacks. Nevertheless, the higher deposition fluxes occurred in the NW/N and NE/E quadrants. This study was conducted considering only the contribution of particulate matter from coal combustion, however, others sources may be present as well, such as road traffic. Additional chemical analyses and microanalysis are needed to identify the source linkage to flux deposition levels.
Resumo:
Due to their detrimental effects on human health, the scientific interest in ultrafine particles (UFP) has been increasing, but available information is far from comprehensive. Compared to the remaining population, the elderly are potentially highly susceptible to the effects of outdoor air pollution. Thus, this study aimed to (1) determine the levels of outdoor pollutants in an urban area with emphasis on UFP concentrations and (2) estimate the respective dose rates of exposure for elderly populations. UFP were continuously measured over 3 weeks at 3 sites in north Portugal: 2 urban (U1 and U2) and 1 rural used as reference (R1). Meteorological parameters and outdoor pollutants including particulate matter (PM10), ozone (O3), nitric oxide (NO), and nitrogen dioxide (NO2) were also measured. The dose rates of inhalation exposure to UFP were estimated for three different elderly age categories: 64–70, 71–80, and >81 years. Over the sampling period levels of PM10, O3 and NO2 were in compliance with European legislation. Mean UFP were 1.7 × 104 and 1.2 × 104 particles/cm3 at U1 and U2, respectively, whereas at rural site levels were 20–70% lower (mean of 1 ×104 particles/cm3). Vehicular traffic and local emissions were the predominant identified sources of UFP at urban sites. In addition, results of correlation analysis showed that UFP were meteorologically dependent. Exposure dose rates were 1.2- to 1.4-fold higher at urban than reference sites with the highest levels noted for adults at 71–80 yr, attributed mainly to higher inhalation rates.
Resumo:
A set of radiation measurements were carried out in several public and private institutions. These were selected with basis on the people affluence and passage to these sites. These measurements were registration formed either indoor, outdoor or underground and were compiled in three Case Studies. Radiation doses measurements were also made, surface and underground locations, and compiled in other two Case Studies. There were sampled, at the same time, humidity, temperature, atmospheric pressure and relevant construction materials at sampling locations. They were collected and registration formed to analyse if there is any relation or contribution for the measured value in each specific place. Geostatistical models were used to elaborate maps of the results both for radiation values and for doses. Preliminary relations were established among the measured parameters.
Resumo:
Os aproveitamentos geotérmicos têm vindo a aumentar significativamente em todo o mundo, sendo os Estados Unidos da América, o maior produtor desta energia proveniente do interior da Terra, com cerca de 3.187 MW de capacidade instalada. Portugal tem capacidade instalada total de 29 MW, no entanto no que se refere ao aproveitamento de “alta entalpia”, isto é, o aproveitamento geotérmico para produção elétrica, apenas se encontra no arquipélago dos Açores, na ilha de S. Miguel, onde estão instaladas e em funcionamento duas centrais geotérmicas com a potência total de 23 MW, com produção de energia de 185 GWh. Em Portugal Continental, não se consegue produzir energia elétrica devido às temperaturas existentes, restringindo esta utilização apenas ao aproveitamento de baixa entalpia (máximo de 76 ºC). Este aproveitamento normalmente é feito em cascata, segundo, predominando o aquecimento de águas sanitárias, climatização, e para termas, usando águas termominerais. Para a exploração deste recurso renovável, é necessário conhecer a hidrogeologia do país, e relacioná-la com a fracturação, e acidentes tectónicos. Portugal Continental, está divido em quatros partes distintas a nível hidrogeológico, o Maciço Antigo, a Orla Ocidental, a Bacia Tejo-Sado e a Orla Meridional. Qualquer aproveitamento geotérmico em Portugal terá de atender a estas características, potenciando também, novas explorações geotérmicas orientadas para as pessoas, respeitando os valores sociais, culturais e ambientais. Neste contexto, existem alguns complexos geotérmicos em funcionamento, outros abandonados, e muitos outros em estudo para uma breve aplicação. Um exemplo de sucesso no aproveitamento do calor geotérmico, é o complexo de Chaves, que foi evoluindo desde 1985, até aos dias de hoje, continuando em exploração e em expansão para um melhor servir da população local. A existência de dois furos, e brevemente dum terceiro, servem para o abastecimento duma piscina, dum hotel, das termas, e da balneoterapia. Devido à riqueza a nível das temperaturas, dos caudais, e ao nível das necessidades energéticas existentes, este complexo apresenta um tempo de retorno de investimento de cerca de 7 anos, o que é geralmente considerado para investimentos para fins públicos, como é o caso. No âmbito das investigações agora realizadas, foi constatado que estes projetos suportam a cobertura de alguma incerteza hidrogeológica, dada a importante procura existente.
Resumo:
The excessive use of pesticides and fertilisers in agriculture has generated a decrease in groundwater and surface water quality in many regions of the EU, constituting a hazard for human health and the environment. Besides, on-site sewage disposal is an important source of groundwater contamination in urban and peri-urban areas. The assessment of groundwater vulnerability to contamination is an important tool to fulfil the demands of EU Directives. The purpose of this study is to assess the groundwater vulnerability to contamination related mainly to agricultural activities in a peri-urban area (Vila do Conde, NW Portugal). The hydrogeological framework is characterised mainly by fissured granitic basement and sedimentary cover. Water samples were collected and analysed for temperature, pH, electrical conductivity, chloride, phosphate, nitrate and nitrite. An evaluation of groundwater vulnerability to contamination was applied (GOD-S, Pesticide DRASTIC-Fm, SINTACS and SI) and the potential nitrate contamination risk was assessed, both on a hydrogeological GIS-based mapping. A principal component analysis was performed to characterised patterns of relationship among groundwater contamination, vulnerability, and the hydrogeological setting assessed. Levels of nitrate above legislation limits were detected in 75 % of the samples analysed. Alluvia units showed the highest nitrate concentrations and also the highest vulnerability and risk. Nitrate contamination is a serious problem affecting groundwater, particularly shallow aquifers, especially due to agriculture activities, livestock and cesspools. GIS-based cartography provided an accurate way to improve knowledge on water circulation models and global functioning of local aquifer systems. Finally, this study highlights the adequacy of an integrated approach, combining hydrogeochemical data, vulnerability assessments and multivariate analysis, to understand groundwater processes in peri-urban areas.
Resumo:
Due to their detrimental effects on human health, scientific interest in ultrafine particles (UFP), has been increasing but available information is far from comprehensive. Children, who represent one of the most susceptible subpopulation, spend the majority of time in schools and homes. Thus, the aim of this study is to (1) assess indoor levels of particle number concentrations (PNC) in ultrafine and fine (20–1000 nm) range at school and home environments and (2) compare indoor respective dose rates for 3- to 5-yr-old children. Indoor particle number concentrations in range of 20–1000 nm were consecutively measured during 56 d at two preschools (S1 and S2) and three homes (H1–H3) situated in Porto, Portugal. At both preschools different indoor microenvironments, such as classrooms and canteens, were evaluated. The results showed that total mean indoor PNC as determined for all indoor microenvironments were significantly higher at S1 than S2. At homes, indoor levels of PNC with means ranging between 1.09 × 104 and 1.24 × 104 particles/cm3 were 10–70% lower than total indoor means of preschools (1.32 × 104 to 1.84 × 104 particles/cm3). Nevertheless, estimated dose rates of particles were 1.3- to 2.1-fold higher at homes than preschools, mainly due to longer period of time spent at home. Daily activity patterns of 3- to 5-yr-old children significantly influenced overall dose rates of particles. Therefore, future studies focusing on health effects of airborne pollutants always need to account for children’s exposures in different microenvironments such as homes, schools, and transportation modes in order to obtain an accurate representation of children overall exposure.
Resumo:
A presente dissertação tem como objetivo principal o estudo da importância que os sistemas de energias renováveis têm na obtenção da classe de eficiência energética em edifícios de habitação. Analisou-se assim, qual dos sistemas apresentados na legislação é mais vantajoso na relação entre a classe energética e o investimento necessário a efetuar. Como caso de estudo, utilizou-se um edifício de habitação em fase de projeto situada em ambiente urbano, a uma distância muito curta da costa marítima, no distrito do Porto. A primeira etapa da dissertação passou pela caracterização do edifício, determinando as suas necessidades nominais anuais de energia para aquecimento, para arrefecimento, para preparação de águas quentes sanitárias e por fim, as necessidades nominais de energia primária. Com isto, obteve-se a classe de eficiência energética da habitação sem a utilização de qualquer tipo de sistema de aproveitamento de energia renovável. Após esta obtenção, verificou-se que o edifício em análise já possuía uma classe muito eficiente, classe A, superior à classe mínima exigida pelo regulamento, B-. A desvantagem do edifício já possuir esta classe é que a implementação de sistemas de energia não iriam alterar drasticamente a classe, e por isso, não se iria conseguir retirar uma dedução correta de qual o melhor para promover a eficiência energética. De seguida, procedeu-se ao estudo dos sistemas de energia renovável, apresentando sistemas adequados para a habitação e calculando-se as novas classes de eficiência energética, com a utilização de cada sistema. Consecutivamente, começou-se a retirar ilações dos sistemas mais eficientes, ou seja, os sistemas que tem como função aquecer a moradia ou a função de preparar águas quentes sanitárias, pois, iriam mitigar necessidades nominais de energia, enquanto os sistemas de produção de energia elétrica apenas iriam contribuir para uma melhoria energética. Outra desvantagem verificada foi que, devido ao local onde a habitação se situa, não seria possível efetuar uma análise a todos os sistemas de aproveitamento de energia renovável. iv Por fim, efetuou-se uma análise dos investimentos necessários para a implementação dos sistemas de energias renováveis face às diminuições percentuais do rácio de eficiência energética. Posto isto, obteve-se os melhores sistemas a implementar na moradia, no ponto de vista de melhorar a classe de eficiência energética, seria uma caldeira a pellets com função de aquecimento e produção de águas quentes sanitárias, enquanto que, do ponto de vista financeiro obteve-se o sistema de aquecimento e produção de águas quentes sanitárias através de um recuperador de calor a lenha, que em ambos os casos a classe de eficiência energética passou de A para A+.