27 resultados para Residual capacity reclaiming
Resumo:
Firms located within a cluster have access to tacit, complex and specific local knowledge which allow them to develop competitive advantage. However, firms have no equal ability to access and to apply that knowledge, meaning that not all have a similar knowledge absorptive capacity. Using a sample of the largest Portuguese firms within a footwear cluster, this paper examine whether there are significant differences in firm’s absorptive capacity and whether such differences within a cluster are related to firms’ specific characteristics. The results suggest that absorptive capacity is significantly associated with the firms’ characteristics, namely size, export intensity and position within the cluster.
Resumo:
Modeling the fundamental performance limits of Wireless Sensor Networks (WSNs) is of paramount importance to understand their behavior under worst-case conditions and to make the appropriate design choices. In that direction this paper contributes with an analytical methodology for modeling cluster-tree WSNs where the data sink can either be static or mobile. We assess the validity and pessimism of analytical model by comparing the worst-case results with the values measured through an experimental test-bed based on Commercial-Off- The-Shelf (COTS) technologies, namely TelosB motes running TinyOS.
Resumo:
This paper proposes a new strategy to integrate shared resources and precedence constraints among real-time tasks, assuming no precise information on critical sections and computation times is available. The concept of bandwidth inheritance is combined with a capacity sharing and stealing mechanism to efficiently exchange bandwidth among tasks to minimise the degree of deviation from the ideal system’s behaviour caused by inter-application blocking. The proposed Capacity Exchange Protocol (CXP) is simpler than other proposed solutions for sharing resources in open real-time systems since it does not attempt to return the inherited capacity in the same exact amount to blocked servers. This loss of optimality is worth the reduced complexity as the protocol’s behaviour nevertheless tends to be fair and outperforms the previous solutions in highly dynamic scenarios as demonstrated by extensive simulations. A formal analysis of CXP is presented and the conditions under which it is possible to guarantee hard real-time tasks are discussed.
Resumo:
This paper proposes a new strategy to integrate shared resources and precedence constraints among real-time tasks, assuming no precise information on critical sections and computation times is available. The concept of bandwidth inheritance is combined with a greedy capacity sharing and stealing policy to efficiently exchange bandwidth among tasks, minimising the degree of deviation from the ideal system's behaviour caused by inter-application blocking. The proposed capacity exchange protocol (CXP) focus on exchanging extra capacities as early, and not necessarily as fairly, as possible. This loss of optimality is worth the reduced complexity as the protocol's behaviour nevertheless tends to be fair in the long run and outperforms other solutions in highly dynamic scenarios, as demonstrated by extensive simulations.
Resumo:
The use of fiber reinforced plastics has increased in the last decades due to their unique properties. Advantages of their use are related with low weight, high strength and stiffness. Drilling of composite plates can be carried out in conventional machinery with some adaptations. However, the presence of typical defects like delamination can affect mechanical properties of produced parts. In this paper delamination influence in bearing stress of drilled hybrid carbon+glass/epoxy quasi-isotropic plates is studied by using image processing and analysis techniques. Results from bearing test show that damage minimization is an important mean to improve mechanical properties of the joint area of the plate. The appropriateness of the image processing and analysis techniques used in the measurement of the damaged area is demonstrated.
Resumo:
The impact of metals (Cd, Cr, Cu and Zn) on growth, cell volume and cell division of the freshwateralga Pseudokirchneriella subcapitata exposed over a period of 72 h was investigated. The algal cells wereexposed to three nominal concentrations of each metal: low (closed to 72 h-EC10values), intermediate(closed to 72 h-EC50values) and high (upper than 72 h-EC90values). The exposure to low metal concen-trations resulted in a decrease of cell volume. On the contrary, for the highest metal concentrations anincrease of cell volume was observed; this effect was particularly notorious for Cd and less pronouncedfor Zn. Two behaviours were found when algal cells were exposed to intermediate concentrations ofmetals: Cu(II) and Cr(VI) induced a reduction of cell volume, while Cd(II) and Zn(II) provoked an oppositeeffect. The simultaneous nucleus staining and cell image analysis, allowed distinguishing three phases inP. subcapitata cell cycle: growth of mother cell; cell division, which includes two divisions of the nucleus;and, release of four autospores. The exposure of P. subcapitata cells to the highest metal concentrationsresulted in the arrest of cell growth before the first nucleus division [for Cr(VI) and Cu(II)] or after thesecond nucleus division but before the cytokinesis (release of autospores) when exposed to Cd(II). Thedifferent impact of metals on algal cell volume and cell-cycle progression, suggests that different toxic-ity mechanisms underlie the action of different metals studied. The simultaneous nucleus staining andcell image analysis, used in the present work, can be a useful tool in the analysis of the toxicity of thepollutants, in P. subcapitata, and help in the elucidation of their different modes of action.
Resumo:
Portugal continental apresenta uma vasta área florestal, que representa cerca de 35,4% da ocupação total do solo, com predominância de espécies como o eucalipto (Eucalyptus globulus) e o pinheiro-bravo (Pinus pinaster). Estas espécies apresentam uma elevada importância a nível económico, designadamente devido à sua ampla utilização, nomeadamente na indústria de celulose e papel, gerando elevadas quantidades de resíduos. Este resíduo de biomassa florestal é utilizado, na sua totalidade, para a geração de energia, na forma de eletricidade ou aquecimento. No entanto, existem outras opções viáveis, a nível económico, tais como a valorização destes subprodutos como fonte de compostos polifenólicos tornando-os, assim, um produto de valor acrescentado. A extração de compostos fenólicos de subprodutos florestais, como folhas de eucalipto e agulhas de pinheiros tem vindo a aumentar devido, principalmente, à substituição de antioxidantes sintéticos, contribuindo para a valorização de subprodutos florestais. Contudo, apesar de todas as potenciais aplicações e vantagens, apenas algumas centenas de espécies aromáticas identificadas são utilizadas à escala comercial. Neste trabalho foi avaliada a capacidade antioxidante de subprodutos da floresta, otimizando as condições de extração através do estudo dos fatores: tempo de extração, temperatura e composição de solvente através do método de superfície de resposta. O planeamento experimental utilizado teve como base um planeamento de compósito central e a avaliação do perfil de antioxidantes das matrizes analisadas foi realizada através de métodos de quantificação total, como o teor fenólico total, a atividade anti-radicalar – método do DPPH (radical 2,2-difenil-1-picrilhidrazilo) e o método de FRAP. Estes métodos analíticos convencionais foram modificados e, devidamente validados, para a análise em leitor de microplacas. Verificou-se que os extratos de pinheiro e de eucalipto, tanto as amostras verdes com as amostras, apresentam uma promissora capacidade antioxidante. O planeamento fatorial aplicado permitiu otimizar as condições de extração em relação às matrizes verdes. Contudo, o mesmo não se verificou em relação às matrizes secas. A composição (% de água) é sem dúvida o fator com mais efeito em todas as amostras (coeficientes de primeira e segunda ordem no modelo). Também a temperatura foi identificada como um fator com efeito significativo sobre os sistemas em análise.
Resumo:
Signal-to-interference ratio (SIR) performance of a multiband orthogonal frequency division multiplexing ultra-wideband system with residual timing offset is investigated. To do so, an exact mathematical derivation of the SIR of this system is derived. It becomes obvious that, unlike a cyclic prefixing based system, a zero padding based system is sensitive to residual timing offset.
Resumo:
This work measures and tries to compare the Antioxidant Capacity (AC) of 50 commercial beverages of different kinds: 6 wines, 12 beers, 18 soft drinks and 14 flavoured waters. Because there is no reference procedure established for this purpose, three different optical methods were used to analyse these samples: Total Radical trapping Antioxidant Parameter (TRAP), Trolox Equivalent Antioxidant Capacity (TEAC) and Ferric ion Reducing Antioxidant Parameter (FRAP). These methods differ on the chemical background and nature of redox system. The TRAP method involves the transfer of hydrogen atoms while TEAC and FRAP involves electron transfer reactions. The AC was also assessed against three antioxidants of reference, Ascorbic acid (AA), Gallic acid (GA) and 6-hydroxy-2,5,7,8-tetramethyl- 2-carboxylic acid (Trolox). The results obtained were analyzed statistically. Anova one-way tests were applied to all results and suggested that methods and standards exhibited significant statistical differences. The possible effect of sample features in the AC, such as gas, flavours, food colouring, sweeteners, acidity regulators, preservatives, stabilizers, vitamins, juice percentage, alcohol percentage, antioxidants and the colour was also investigated. The AC levels seemed to change with brand, kind of antioxidants added, and kind of flavour, depending on the sample. In general, higher ACs were obtained for FRAP as method, and beer for kind of sample, and the standard expressing the smaller AC values was GA.
Resumo:
The total antioxidant capacity (TAC) of 28 flavoured water samples was assessed by ferric reducing antioxidant potential (FRAP), oxygen radical absorbance capacity (ORAC), trolox equivalent antioxidant capacity (TEAC) and total reactive antioxidant potential (TRAP) methods. It was observed that flavoured waters had higher antioxidant activity than the corresponding natural ones. The observed differences were attributed to flavours, juice and vitamins. Generally, higher TAC contents were obtained on lemon waters and lower values on guava and raspberry flavoured waters. Lower and higher TACs were obtained by TRAP and ORAC method, respectively. Statistical analysis suggested that vitamins and flavours increased the antioxidant content of the commercial waters.
Resumo:
Endophyte-assisted phytoremediation has recently been suggested as a successful approach for ecological restoration of metal contaminated soils, however little information is available on the influence of endophytic bacteria on the phytoextraction capacity of metal hyperaccumulating plants in multi-metal polluted soils. The aims of our study were to isolate and characterize metal-resistant and 1-aminocyclopropane-1-carboxylate (ACC) utilizing endophytic bacteria from tissues of the newly discovered Zn/Cd hyperaccumulator Sedum plumbizincicola and to examine if these endophytic bacterial strains could improve the efficiency of phytoextraction of multi-metal contaminated soils. Among a collection of 42 metal resistant bacterial strains isolated from the tissues of S. plumbizincicola grown on Pb/Zn mine tailings, five plant growth promoting endophytic bacterial strains (PGPE) were selected due to their ability to promote plant growth and to utilize ACC as the sole nitrogen source. The five isolates were identified as Bacillus pumilus E2S2, Bacillus sp. E1S2, Bacillus sp. E4S1, Achromobacter sp. E4L5 and Stenotrophomonas sp. E1L and subsequent testing revealed that they all exhibited traits associated with plant growth promotion, such as production of indole-3-acetic acid and siderophores and solubilization of phosphorus. These five strains showed high resistance to heavy metals (Cd, Zn and Pb) and various antibiotics. Further, inoculation of these ACC utilizing strains significantly increased the concentrations of water extractable Cd and Zn in soil. Moreover, a pot experiment was conducted to elucidate the effects of inoculating metal-resistant ACC utilizing strains on the growth of S. plumbizincicola and its uptake of Cd, Zn and Pb in multi-metal contaminated soils. Out of the five strains, B. pumilus E2S2 significantly increased root (146%) and shoot (17%) length, fresh (37%) and dry biomass (32%) of S. plumbizincicola as well as plant Cd uptake (43%), whereas Bacillus sp. E1S2 significantly enhanced the accumulation of Zn (18%) in plants compared with non-inoculated controls. The inoculated strains also showed high levels of colonization in rhizosphere and plant tissues. Results demonstrate the potential to improve phytoextraction of soils contaminated with multiple heavy metals by inoculating metal hyperaccumulating plants with their own selected functional endophytic bacterial strains.
Resumo:
A água é um recurso natural único, escasso e essencial a todos os seres vivos, o que a torna um bem de extrema importância. Nos dias de hoje, o desperdício deste bem, aliado ao aumento da sua procura, tornou-se um problema devido à decrescente disponibilidade de água doce no nosso planeta. Todas as águas que rejeitamos depois da sua utilização para diversos fins, designadas de águas residuais, necessitam de tratamento antes de serem devolvidas ao meio ambiente. O seu tratamento é realizado numa Estação de Tratamento de Águas Residuais (ETAR) e o processo de tratamento depende das suas características. A ETAR das Termas de S. Vicente, em Penafiel, trabalha no seu limite de capacidade, apresenta uma sobrecarga hidráulica gerada por uma afluência de águas pluviais e o processamento das lamas geradas não permite uma secagem tão completa como seria desejável. Assim, este trabalho teve como objetivo o estudo do funcionamento desta ETAR com a finalidade de propor soluções que o possam otimizar. As soluções propostas para otimizar o funcionamento da ETAR em estudo são: i) a substituição de grades de limpeza manual por grades de limpeza automática de forma a reduzir a necessidade da intervenção do operador ao nível da remoção e condicionamento dos gradados; ii) a construção de um desarenador arejado que além de remover areias de diâmetro superior a 0,2 mm promove também a remoção de gorduras, protegendo desta forma os equipamentos a jusante da abrasão/desgaste prematuros e reduzindo a formação de depósitos nas tubagens; iii) a construção de um tanque de equalização de forma a garantir uma distribuição mais uniforme dos caudais e da carga poluente; iv) a substituição do enchimento do leito percolador por um meio de suporte plástico que permite atingir melhores eficiências de remoção neste tratamento biológico; v) a alteração do agente de desinfeção para radiação ultravioleta, evitando a adição de produtos químicos na água residual e possível formação de subprodutos prejudiciais ao ambiente, como ocorreria no caso da cloragem; e vi) a substituição da desidratação de lamas em leitos de secagem por filtros de banda, que é um processo mais rápido, que ocupa menos espaço e permite atingir elevadas eficiências de remoção de humidade. Para cada uma das sugestões são apresentadas as correspondentes especificações técnicas e dimensionamento. As sugestões de melhoria apresentadas neste trabalho constituem uma alternativa mais económica do que a ampliação da ETAR, que genericamente corresponde à duplicação da linha de tratamento atual. Devido à menor complexidade em termos de construção, estas sugestões podem vir a ser implementadas num futuro próximo, prolongando assim um pouco mais a vida útil da ETAR atual.