37 resultados para LIQUID-CHROMATOGRAPHY
Resumo:
A detailed study of voltammetric behavior of ethiofencarb (ETF) is reported using glassy carbon electrode (GCE) and hanging mercury drop electrode (HMDE). With GCE, it is possible to verify that the oxidative mechanism is irreversible, independent of pH, and the maximum intensity current was observed at +1.20 V vs. AgCl/Ag at pH 1.9. A linear calibration line was obtained from 1.0x10-4 to 8.0x10-4 mol L-1 with SWV method. To complete the electrochemical knowledge of ETF pesticide, the reduction was also explored with HMDE. A well-defined peak was observed at –1.00V vs. AgCl/Ag in a large range of pH with higher signal at pH 7.0. Linearity was obtained in 4.2x10-6 and 9.4x10-6 mol L-1 ETF concentration range. An immediate alkaline hydrolysis of ETF was executed, producing a phenolic compound (2-ethylthiomethylphenol) (EMP), and the electrochemical activity of the product was examined. It was deduced that it is oxidized on GCE at +0.75V vs. AgCl/Ag with a maximum peak intensity current at pH 3.2, but the compound had no reduction activity on HMDE. Using the decrease of potential peak, a flow injection analysis (FIA) system was developed connected to an amperometric detector, enabling the determination of EMP over concentration range of 1.0x10-7 and 1.0x10-5 mol L-1 at a sampling rate of 60 h-1. The results provided by FIA methodology were performed by comparison with results from high-performance liquid chromatography (HPLC) technique and demonstrated good agreement with relative deviations lower than 4%. Recovery trials were performed and the obtained values were between 98 and 104%.
Resumo:
Ochratoxin A (OTA) is a mycotoxin produced by a variety of fungi, such as Penicillium verrucosum and Aspergillium spp., which has been found to have a wide number of potentially deadly toxic effects, and can enter the human organism through a variety of means. It then finds its way into the bloodstream and, after a lengthy process, is eventually excreted through the urine. It can thus be detected in its original form not only in blood samples but also in this biological medium. As such, and in an attempt to evaluate the exposure of the Portuguese population to this mycotoxin, morning urine samples were collected during the Winter of 2007, from each of five geographically distinct Portuguese locations — Bragança, Porto, Coimbra, Alentejo, and Algarve — and subjected to extraction by immunoaffinity columns and to OTA quantification through liquid chromatography coupled with fluorescence detection. Prevalent incidence was higher than 95% with Coimbra being the exception (incidence of 73.3%). In nearly all locations, the OTA content of most samples was found to be above the limit of quantification (LOQ) of 0.008 ng/ml. Indeed, excluding Coimbra, with an OTA content level of 0.014 ng/ml, all regions featured content values over 0.021 ng/ml.
Resumo:
Because polycyclic aromatic hydrocarbons (PAHs) have been proven to be toxic, mutagenic, and/or carcinogenic, there is widespread interest in analyzing and evaluating exposure to PAHs in atmospheric environments influenced by different emission sources. Because traffic emissions are one of the biggest sources of fine particles, more information on carcinogenic PAHs associated with fine particles needs to be provided. Aiming to further understand the impact of traffic particulate matter (PM) on human health, this study evaluated the influence of traffic on PM10 (PM with aerodynamic diameter <10 µm) and PM2.5 (PM with aerodynamic diameter <2.5 µm), considering their concentrations and compositions in carcinogenic PAHs. Samples were collected at one site influenced by traffic emissions and at one reference site using lowvolume samplers. Analysis of PAHs was performed by microwave-assisted extraction combined with liquid chromatography (MAE-LC); 17 PAHs, including 9 carcinogenic ones, were quantified. At the site influenced by traffic emissions, PM10 and PM2.5 concentrations were, respectively, 380 and 390% higher than at the background site. When influenced by traffic emissions, the total concentration of nine carcinogenic compounds (naphthalene, chrysene, benzo(a)anthracene, benzo(b) fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, indeno(1,2,3-cd)pyrene, and dibenzo(a,l)pyrene) was increased by 2400 and 3000% in PM10 and PM2.5, respectively; these nine carcinogenic compounds represented 68 and 74% of total PAHs (ƩPAHs) for PM10 and PM2.5, respectively. All PAHs, including the carcinogenic compounds, were mainly present in fine particles. Considering the strong influence of these fine particles on human health, these conclusions are relevant for the development of strategies to protect public health.
Resumo:
A glutathione-S-transferase (GST)based biosensor was developed to quantify the thiocarbamate herbicide molinate in environmental water.The biosensor construction was based on GST immobilization onto a glassy carbon electrode via aminosilane–glutaraldehyde covalent attachment. The principle supporting the use of this biosensor consists of the GST inhibition process promoted by molinate. Differential pulse voltammetry was used to obtain a calibration curve for molinate concentration, ranging from 0.19 to 7.9 mgL -1 and presenting a detection limit of 0.064 mgL- 1. The developed biosensor is stable,and reusable during 15 days.The GST-based biosensor was successfully applied to quantify molinate in rice paddy field floodwater samples. The results achieved with the developed biosensor were in accordance with those obtained by high performance liquid chromatography. The proposed device is suitable for screening environmental water analysis and, since no sample preparation is required, it can be used in situ and in real-time measurements.
Resumo:
The present work describes the development of an analytical method for the determination of methiocarb and its degradation products (methiocarb sulfoxide and methiocarb sulfone) in banana samples, using the QuEChERS (quick, easy, cheap, effective, rugged, and safe) procedure followed by liquid chromatography coupled to photodiode array detector (LCPAD). Calibration curves were linear in the range of 0.5−10 mg L−1 for all compounds studied. The average recoveries, measured at 0.1 mg kg−1 wet weight, were 92.0 (RSD = 1.8%, n = 3), 84.0 (RSD = 3.9%, n = 3), and 95.2% (RSD = 1.9%, n = 3) for methiocarb sulfoxide, methiocarb sulfone, and methiocarb, respectively. Banana samples treated with methiocarb were collected from an experimental field. The developed method was applied to the analysis of 24 samples (peel and pulp) and to 5 banana pulp samples. Generally, the highest levels were found for methiocarb sulfoxide and methiocarb. Methiocarb sulfone levels were below the limit of quantification, except in one sample (not detected).
Resumo:
Paracetamol is among the most worldwide consumed pharmaceuticals. Although its occurrence in the environment is well documented, data about the presence of its metabolites and transformation products is very scarce. The present work describes the development of an analytical method for the simultaneous determination of paracetamol, its principal metabolite (paracetamol-glucuronide) and its main transformation product (p-aminophenol) based on solid phase extraction (SPE) and high performance liquid chromatography coupled to diode array detection (HPLC-DAD). The method was applied to analysis of river waters, showing to be suitable to be used in routine analysis. Different SPE sorbents were compared and the use of two Oasis WAX cartridges in tandem proved to be the most adequate approach for sample clean up and pre-concentration. Under optimized conditions, limits of detection in the range 40–67 ng/L were obtained, as well as mean recoveries between 60 and 110% with relative standard deviations (RSD) below 6%. Finally, the developed SPE-HPLC/DAD method was successfully applied to the analysis of the selected compounds in samples from seven rivers located in the north of Portugal. Nevertheless all the compounds were detected, it was the first time that paracetamol-glucuronide was found in river water at concentrations up to 3.57 μg/L.
Resumo:
Ibuprofen is amongst the most worldwide consumed pharmaceuticals. The present work presents the first data in the occurrence of ibuprofen in Portuguese surface waters, focusing in the north area of the country, which is one of the most densely populated areas of Portugal. Analysis of ibuprofen is based on pre-concentration of the analyte with solid phase extraction and subsequent determination with liquid chromatography coupled to fluorescence detection. A total of 42 water samples, including surface waters, landfill leachates,Wastewater Treatment Plant (WWTP), and hospital effluents, were analyzed in order to evaluate the occurrence of ibuprofen in the north of Portugal. In general, the highest concentrations were found in the river mouths and in the estuarine zone. The maximum concentrations found were 48,720 ngL−1 in the landfill leachate, 3,868 ngL−1 in hospital effluent, 616 ngL−1 in WWTP effluent, and 723 ngL−1 in surface waters (Lima river). Environmental risk assessment was evaluated and at the measured concentrations only landfill leachates reveal potential ecotoxicological risk for aquatic organisms. Owing to a high consumption rate of ibuprofen among Portuguese population, as prescribed and nonprescribed medicine, the importance of hospitals, WWTPs, and landfills as sources of entrance of pharmaceuticals in the environment was pointed out. Landfill leachates showed the highest contribution for ibuprofen mass loading into surface waters. On the basis of our findings, more studies are needed as an attempt to assess more vulnerable areas.
Resumo:
An analytical method using microwave-assisted extraction (MAE) and liquid chromatography (LC) with fluorescence detection (FD) for the determination of ochratoxin A (OTA) in bread samples is described. A 24 orthogonal composite design coupled with response surface methodology was used to study the influence of MAE parameters (extraction time, temperature, solvent volume, and stirring speed) in order to maximize OTA recovery. The optimized MAE conditions were the following: 25 mL of acetonitrile, 10 min of extraction, at 80 °C, and maximum stirring speed. Validation of the overall methodology was performed by spiking assays at five levels (0.1–3.00 ng/g). The quantification limit was 0.005 ng/g. The established method was then applied to 64 bread samples (wheat, maize, and wheat/maize bread) collected in Oporto region (Northern Portugal). OTAwas detected in 84 % of the samples with a maximum value of 2.87 ng/g below the European maximum limit established for OTA in cereal products of 3 ng/g.
Resumo:
Atmospheric pollution by motor vehicles is considered a relevant source of damage to architectural heritage. Thus the aim of this work was to assess the atmospheric depositions and patterns of polycyclic aromatic hydrocarbons (PAHs) in façades of historical monuments. Eighteen PAHs (16 PAHs considered by US EPA as priority pollutants, dibenzo[a,l]pyrene and benzo[j]fluoranthene) were determined in thin black layers collected from façades of two historical monuments: Hospital Santo António and Lapa Church (Oporto, Portugal). Scanning electron microscopy (SEM) was used for morphological and elemental characterisation of thin black layers; PAHs were quantified by microwave-assisted extraction combined with liquid chromatography (MAE-LC). The thickness of thin black layers were 80–110 μm and they contained significant levels of iron, sulfur, calcium and phosphorus. Total concentrations of 18 PAHs ranged from 7.74 to 147.92 ng/g (mean of 45.52 ng/g) in thin black layers of Hospital Santo António, giving a range three times lower than at Lapa Church (5.44– 429.26 ng/g; mean of 110.25 ng/g); four to six rings compounds accounted at both monuments approximately for 80–85% of ΣPAHs. The diagnostic ratios showed that traffic emissions were significant source of PAHs in thin black layers. Composition profiles of PAHs in thin black layers of both monuments were similar to those of ambient air, thus showing that air pollution has a significant impact on the conditions and stone decay of historical building façades. The obtained results confirm that historical monuments in urban areas act as passive repositories for air pollutants present in the surrounding atmosphere.
Resumo:
Mestrado em Engenharia Química - Ramo Optimização Energética na Indústria Química
Resumo:
O recente surgimento de nanopartículas de ferro valente-zero (nFZV), um material com elevada capacidade de remediação de solos por via de reacções de oxidação/redução pode ser uma opção viável para a remoção de fármacos do solo. A sua aplicação já é uma realidade em alguns tipos de solos contaminados por compostos específicos e, com este trabalho, procura-se estudar a sua capacidade de remediação de solos contaminados por compostos farmacêuticos, recorrendo-se a uma tecnologia “verde” de síntese destas nanopartículas. Esta tecnologia é bastante recente, ainda não aplicada no campo de trabalho, que se baseia no uso de folhas de certas árvores para produzir extratos naturais que reduzem o ferro (III) a ferro zero valente, formando nFZV. Desta forma procedeu-se, à escala laboratorial, ao estudo da eficiência das nFZV na degradação de um fármaco – paracetamol – e comparou-se com a eficiência demonstrada por oxidantes, muito utilizados hoje em dia em casos de remediação in situ como o permanganato de potássio, o peróxido de hidrogénio, o persulfato de sódio e o reagente de Fenton. O estudo foi efectuado em dois meios diferentes: solução aquosa e solo arenoso. De forma muito sucinta, o estudo baseou-se na introdução dos oxidantes/nFZV em soluções/solos contaminados com paracetamol e consequente monitorização do processo de remediação através de cromatografia líquida de alta eficiência. Nos ensaios com soluções aquosas contaminadas com paracetamol, o permanganato de potássio e o reagente de Fenton revelaram capacidade para degradar o paracetamol, atingindo mesmo um grau de degradação de 100%. O persulfato de sódio também demonstrou uma capacidade de degradação do paracetamol, chegando a atingir 99% de degradação, mas apenas recorrendo ao uso de um volume de oxidante elevado quando comparado com os outros dois oxidantes já referidos. Por outro lado, o peróxido de hidrogénio não demonstrou qualquer capacidade de degradação do paracetamol, pelo que o seu uso não passou desta fase. Verificou-se também que o uso de ferro granulado para o tratamento de água contaminada com paracetamol revelou resultados diferentes dos observados no uso de nFZV, obtendo-se eficiências de 87%. Existiram dificuldades analíticas na quantificação do paracetamol, especificamente relacionadas com o uso do extracto de folhas de amoreira, cuja composição continha substâncias que causaram dificuldades acentuadas na análise dos cromatogramas. Por fim, um pequeno teste de combinação do reagente de Fenton com os fenómenos de biodegradação resultantes dos microrganismos presentes em folhas do extracto de chá preto demonstrou que este pode ser uma área que pode e deve ser mais estudada. Desta forma, a utilização das nFZV para o tratamento de água contaminada com paracetamol não permitiu a retirada de conclusões seguras sobre a capacidade que as nFZV produzidas com extractos de folhas de amoreira e de chá preto têm de degradação do paracetamol. Nos testes de remediação de solos contaminados os resultados demonstraram que, mais uma vez, tanto o permanganato de potássio como o reagente de Fenton se revelam como os melhores oxidantes para a degradação do paracetamol, obtendo-se a degradação total do paracetamol. Por outro lado, voltou a ser necessário uma elevada quantidade de persulfato de sódio quando comparada com os dois anteriores, para que ocorra a degradação desta mesma quantidade de paracetamol, demonstrando mais uma vez que, apesar de não ideal, o persulfato demonstra capacidade de degradação do paracetamol.
Resumo:
A new analytical methodology, based on liquid chromatography with fluorescence detection (LC-FD), after extraction, enzymatic hydrolysis, and solid-phase extraction (SPE) through Oasis HLB cartridges, was developed and validated for the simultaneous determination of three monohydroxy derivatives of polycyclic aromatic hydrocarbons (PAHs). The optimized analytical method is sensitive, accurate, and precise, with recoveries between 62 and 110% and limits of detection of 227, 9, and 45 ng/g for 1-hydroxynaphthalene, 2-hydroxyfluorene, and 1-hydroxypyrene, respectively. Their levels were estimated in different cephalopod matrices (edible tissues and hemolymph). The methodology was applied to samples of the major cephalopod species consumed worldwide. Of the 18 samples analyzed, 39% were contaminated with 1-hydroxynaphthalene, which was the only PAH metabolite detected. Its concentration ranged from 786 to 1145 ng/g. This highly sensitive and specific method allows the identification and quantitation of PAH metabolites in forthcoming food safety and environmental monitoring programs.
Resumo:
O leite é um alimento complexo, pela sua composição rico em água, proteínas, lípidos, vitaminas e minerais. Devido ao seu alto valor nutricional é fundamental para a amamentação de crianças e animais em crescimento, pois fornece componentes fundamentais para o desenvolvimento e manutenção da saúde. Os antimicrobianos são amplamente utilizados como uma medida terapêutica no tratamento de infeções bacterianas, profilaxia e como promotores de crescimento (aditivos). A presença de resíduos de antimicrobianos no leite pode representar riscos para a saúde humana, como reações alérgicas em indivíduos hipersensíveis e resistências. Os objetivos deste estudo são o desenvolvimento de novos métodos de limpeza e de pré-concentração para amostras de leite, por meio de extração em fase sólida (SPE), com a finalidade de realizar uma melhor identificação e quantificação de antimicrobiana por Cromatografia Líquida de Alta Performance (HPLC). Todos os métodos desenvolvidos são de fácil execução, com taxas de recuperação dos agentes antimicrobianos viáveis, com uma percentagem de recuperação a partir de 85%. O método cromatográfico utilizado para a deteção e quantificação (HPLC-DAD) têm os limites de deteção (LD) entre 2.43ng / mL e 1.62ng / mL e os limites de quantificação (LQ) entre 7,36 ng / mL e 4.92 ng / mL, o que significa este método vai de encontro às diretrizes estipuladas pela União Europeia para os agentes antimicrobianos estudados. A combinação dos métodos propostos de limpeza e pré-concentração por SPE e multirresíduo por HPLC-DAD permite, por conseguinte, a deteção e quantificação de resíduos de antibióticos no leite, tornando esta uma alternativa importante e útil no processo de controlo de qualidade para a indústria de alimentos e outras área.
Resumo:
Advanced glycation end-products are Maillard reaction products that are found in thermal processed food. This compounds are often referred as unhealthy for human diet, namely because of their capacity to form amino-acid dimers. There is a broad range of answers to get about how these products are formed, how they interact with the organism and how these reactions can be inhibited to prevent the referred effects. Some compounds from garlic are thought to be able to inhibit these reactions. This study using spectrophotometric, High Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS) and Fourier transformed infrared spectroscopy (FTIR) analysis, helps to understand better not only not only the effect of some compounds obtained from garlic, diallyl sulfide (DAS), diallyl disulfide (DADS) and diallyl trisulfide (DATS), on these AGEs production reaction, but also helped to understand better the reaction itself.
Resumo:
O leite é um alimento complexo, pela sua composição rico em água, proteínas, lípidos, vitaminas e minerais. Devido ao seu alto valor nutricional é fundamental para a amamentação de crianças e animais em crescimento, pois fornece componentes fundamentais para o desenvolvimento e manutenção da saúde. Os antimicrobianos são amplamente utilizados como uma medida terapêutica no tratamento de infeções bacterianas, profilaxia e como promotores de crescimento (aditivos). A presença de resíduos de antimicrobianos no leite pode representar riscos para a saúde humana, como reações alérgicas em indivíduos hipersensíveis e resistências. Os objetivos deste estudo são o desenvolvimento de novos métodos de limpeza e de pré- concentração para amostras de leite, por meio de extração em fase sólida (SPE), com a finalidade de realizar uma melhor identificação e quantificação de antimicrobiana por Cromatografia Líquida de Alta Performance (HPLC). Todos os métodos desenvolvidos são de fácil execução, com taxas de recuperação dos agentes antimicrobianos viáveis, com uma percentagem de recuperação a partir de 85%. O método cromatográfico utilizado para a deteção e quantificação (HPLC-DAD) têm os limites de deteção (LD) entre 2.43ng / mL e 1.62ng / mL e os limites de quantificação (LQ) entre 7,36 ng / mL e 4.92 ng / mL, o que significa este método vai de encontro às diretrizes estipuladas pela União Europeia para os agentes antimicrobianos estudados. A combinação dos métodos propostos de limpeza e pré-concentração por SPE e multirresíduo por HPLC-DAD permite, por conseguinte, a deteção e quantificação de resíduos de antibióticos no leite, tornando esta uma alternativa importante e útil no processo de controlo de qualidade para a indústria de alimentos e outras área.