20 resultados para GAS BURNERS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A procedure for the determination of seven indicator PCBs in soils and sediments using microwave-assisted extraction (MAE) and headspace solid-phase microextraction (HS-SPME) prior to GC-MS/MS is described. Optimization of the HS-SPME was carried out for the most important parameters such as extraction time, sample volume and temperature. The adopted methodology has reduced consumption of organic solvents and analysis runtime. Under the optimized conditions, the method detection limit ranged from 0.6 to 1 ng/g when 5 g of sample was extracted, the precision on real samples ranged from 4 to 21% and the recovery from 69 to 104%. The proposed method, which included the analysis of a certified reference material in its validation procedure, can be extended to several other PCBs and used in the monitoring of soil or sediments for the presence of PCBs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amulti-residue methodology based on a solid phase extraction followed by gas chromatography–tandem mass spectrometry was developed for trace analysis of 32 compounds in water matrices, including estrogens and several pesticides from different chemical families, some of them with endocrine disrupting properties. Matrix standard calibration solutions were prepared by adding known amounts of the analytes to a residue-free sample to compensate matrix-induced chromatographic response enhancement observed for certain pesticides. Validation was done mainly according to the International Conference on Harmonisation recommendations, as well as some European and American validation guidelines with specifications for pesticides analysis and/or GC–MS methodology. As the assumption of homoscedasticity was not met for analytical data, weighted least squares linear regression procedure was applied as a simple and effective way to counteract the greater influence of the greater concentrations on the fitted regression line, improving accuracy at the lower end of the calibration curve. The method was considered validated for 31 compounds after consistent evaluation of the key analytical parameters: specificity, linearity, limit of detection and quantification, range, precision, accuracy, extraction efficiency, stability and robustness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O potencial de um reservatório de shale gas e influenciado por um grande número de fatores, tais como a sua mineralogia e textura, o seu tipo e maturação de querogénio, a saturação de fluidos, os mecanismos de armazenamento de gás, a profundidade do reservatório e a temperatura e pressão de poros. Nesse sentido, o principal objetivo desta tese foi estabelecer uma metodologia de avaliação preliminar de potenciais jazigos de shale gas (estudo de afloramentos com base numa litoestratigrafia de alta resolução), que foi posteriormente aplicada na Formação de Vale das Fontes (Bacia Lusitânica, Portugal). Esta tese tem a particularidade de contribuir, não só para o aprofundamento da informação a nível geoquímico do local, mas também na abordagem inovadora que permitiu a caracterização petrofísica da Formação de Vale das Fontes. Para a aplicação da metodologia estabelecida, foi necessária a realização dos seguintes ensaios laboratoriais: Rock-Eval 6, picnometria de gás hélio, ensaio de resistência a compressão simples, Darcypress e a difracção de raios-X, aplicando o método de Rietveld. Os resultados obtidos na análise petrofísica mostram uma formação rochosa de baixa porosidade que segundo a classificação ISRM, e classificada como ”Resistente”, para alem de revelar comportamento dúctil e elevado índice de fragilidade. A permeabilidade média obtida situa a Formação no intervalo correspondente as permeabilidades atribuídas aos jazigos de tigh gas, indicando a necessidade de fracturação hidráulica, no caso de uma eventual exploração de hidrocarbonetos, enquanto a difracção de raios-X destaca a calcite, o quartzo e os filossilicatos como os minerais mais presentes na Formação. Do ponto de vista geoquímico, os resultados obtidos mostram que apesar do considerável teor médio de carbono orgânico total, a natureza da matéria orgânica analisada e maioritariamente imatura, composta, principalmente, por querogénio do tipo IV, o que indica a incapacidade de a formação gerar hidrocarbonetos em quantidades economicamente exploráveis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ammonia is an important gas in many power plants and industrial processes so its detection is of extreme importance in environmental monitoring and process control due to its high toxicity. Ammonia’s threshold limit is 25 ppm and the exposure time limit is 8 h, however exposure to 35 ppm is only secure for 10 min. In this work a brief introduction to ammonia aspects are presented, like its physical and chemical properties, the dangers in its manipulation, its ways of production and its sources. The application areas in which ammonia gas detection is important and needed are also referred: environmental gas analysis (e.g. intense farming), automotive-, chemical- and medical industries. In order to monitor ammonia gas in these different areas there are some requirements that must be attended. These requirements determine the choice of sensor and, therefore, several types of sensors with different characteristics were developed, like metal oxides, surface acoustic wave-, catalytic-, and optical sensors, indirect gas analyzers, and conducting polymers. All the sensors types are described, but more attention will be given to polyaniline (PANI), particularly to its characteristics, syntheses, chemical doping processes, deposition methods, transduction modes, and its adhesion to inorganic materials. Besides this, short descriptions of PANI nanostructures, the use of electrospinning in the formation of nanofibers/microfibers, and graphene and its characteristics are included. The created sensor is an instrument that tries to achieve a goal of the medical community in the control of the breath’s ammonia levels being an easy and non-invasive method for diagnostic of kidney malfunction and/or gastric ulcers. For that the device should be capable to detect different levels of ammonia gas concentrations. So, in the present work an ammonia gas sensor was developed using a conductive polymer composite which was immobilized on a carbon transducer surface. The experiments were targeted to ammonia measurements at ppb level. Ammonia gas measurements were carried out in the concentration range from 1 ppb to 500 ppb. A commercial substrate was used; screen-printed carbon electrodes. After adequate surface pre-treatment of the substrate, its electrodes were covered by a nanofibrous polymeric composite. The conducting polyaniline doped with sulfuric acid (H2SO4) was blended with reduced graphene oxide (RGO) obtained by wet chemical synthesis. This composite formed the basis for the formation of nanofibers by electrospinning. Nanofibers will increase the sensitivity of the sensing material. The electrospun PANI-RGO fibers were placed on the substrate and then dried at ambient temperature. Amperometric measurements were performed at different ammonia gas concentrations (1 to 500 ppb). The I-V characteristics were registered and some interfering gases were studied (NO2, ethanol, and acetone). The gas samples were prepared in a custom setup and were diluted with dry nitrogen gas. Electrospun nanofibers of PANI-RGO composite demonstrated an enhancement in NH3 gas detection when comparing with only electrospun PANI nanofibers. Was visible higher range of resistance at concentrations from 1 to 500 ppb. It was also observed that the sensor had stable, reproducible and recoverable properties. Moreover, it had better response and recovery times. The new sensing material of the developed sensor demonstrated to be a good candidate for ammonia gas determination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho centrou-se na otimização do rendimento térmico de duas caldeiras aquatubulares da empresa RAR- Refinaria de Açúcar Reunidas, com a finalidade de identificar onde ocorrem perdas de energia e, desta forma, propor soluções para a sua minimização. Para tal, realizaram-se ensaios em duas caldeiras da empresa providas de queimadores mistos, ou seja podem operar com fuelóleo e gás natural, tanto individualmente, como simultaneamente, sendo que para a realização dos ensaios apenas se utilizou o fuelóleo devido ao seu menor custo. Na caldeira designada por 1 realizaram-se ensaios para os caudais de 300, 500, 800, 1000, 1200, 1400 e 1600 kg/h de fuelóleo. A gama de rendimentos térmicos obtida foi entre 88,3 e 91,2%. Na caldeira designada por 3, efetuaram-se ensaios para os caudais de fuelóleo de 300, 500, 700, 900, 1000, 1200, 1400, 1500 e 1800 kg/h e os rendimentos térmicos obtidos foram entre 85,2 e 88,0%. Em ambas as caldeiras e para caudais baixos verificou-se que a quantidade de ar introduzida no processo de combustão era superior à necessária, conduzindo a uma diminuição dos valores de rendimento térmico. Para 500 kg/h de fuelóleo, por exemplo, a quantidade de ar utilizada foi cerca de duas vezes superiores ao valor estequiométrico. Tendo em conta estes factos, foi proposto ao gestor de energia a implementação de uma nova relação de ar/combustível vs caudal de combustível no sistema de controlo das referidas caldeiras. Após alguns testes (excluindo 300 kg/h de fuelóleo devido a questões de operação), considerou-se como caudal mínimo de operação os 500 Kg/h de fuelóleo nas respetivas caldeiras 1 e 3. Verificou-se que os rendimentos térmicos aumentaram, no caso da caldeira 1, para valores entre os 90,1 e 91,3% e, na caldeira 3, para valores entre 89,0 e 90,9%. Por fim, efetuou-se uma breve análise económica com o intuito de se avaliar e quantificar o que a empresa pode poupar com esta medida. O lucro anual pode oscilar entre 14.400 e 62.640€ ou 104.400 e 136.800€, para as caldeiras 1 e 3, respetivamente.