34 resultados para Double Strap Joint
Resumo:
We address the problem of coordinating two non-holonomic mobile robots that move in formation while transporting a long payload. A competitive dynamics is introduced that gradually controls the activation and deactivation of individual behaviors. This process introduces (asymmetrical) hysteresis during behavioral switching. As a result behavioral oscillations, due to noisy information, are eliminated. Results in indoor environments show that if parameter values are chosen within reasonable ranges then, in spite of noise in the robots communi- cation and sensors, the overall robotic system works quite well even in cluttered environments. The robots overt behavior is stable and smooth.
Resumo:
This work addresses both experimental and numerical analyses regarding the tensile behaviour of CFRP single-strap repairs. Two fundamental geometrical parameters were studied: overlap length and patch thickness. The numerical model used ABAQUS® software and a developed cohesive mixed-mode damage model adequate for ductile adhesives, and implemented within interface finite elements. Stress analyses and strength predictions were carried out. Experimental and numerical comparisons were performed on failure modes, failure load and equivalent stiffness of the repair. Good correlation was found between experimental and numerical results, showing that the proposed model can be successfully applied to bonded joints or repairs.
Resumo:
This article studies several Fractional Order Control algorithms used for joint control of a hexapod robot. Both Padé and series approximations to the fractional derivative are considered for the control algorithm. The walking performance is evaluated through two indices: The mean absolute density of energy used per unit distance travelled, and the control effort. A set of simulation experiments reveals the influence of the different approximations upon the proposed indices. The results show that the fractional proportional and derivative algorithm, implemented using the Padé approximation with a small number of terms, gives the best results.
Resumo:
Este trabalho descreve a abordagem abrangente sobre a melhoria do sistema de gestão da qualidade na Unidade de Imagiologia do Hospital da Boavista através da implementação das normas de acreditação da Joint Commission International (JCI). Fundamental para a melhoria geral da qualidade é a redução contínua de riscos para os doentes e para os profissionais da Unidade. Tais riscos podem existir ao nível do ambiente físico assim como no circuito dos exames e dos doentes. A acreditação em Saúde é uma das prioridades estratégicas do Ministério da Saúde e tem como objetivo fortalecer a confiança dos cidadãos nos profissionais de saúde bem como nas instituições de saúde. É importante que Portugal cultive a melhoria da qualidade e segurança nas instituições de saúde mantendo uma relação adequada custo/benefício. A União Europeia tem feito um esforço para que a acreditação seja harmoniosa nos seus princípios, no entanto é respeitada sempre a prevalência da legislação de cada país, bem como as suas especificações culturais e religiosas (Shaw, 2006), responsabilizando-o pelo seu sistema de saúde O trabalho aqui apresentado tem como objetivo principal fundamentar a escolha do modelo de acreditação da JCI para o Hospital da Boavista, nomeadamente para a Unidade de Imagiologia, ver se os padrões estão de acordo com os procedimentos da Unidade, identificar falhas e apontar possiveis melhorias. Pretende-se ainda mostrar a importância da implementação dos sistemas de certificação e acreditação da gestão da qualidade, documentada pela experiência profissional, bem como o know-how do Hospital da Boavista, assim como a complementaridade dos programas da gestão da qualidade, certificação e acreditação. A escolha do modelo de acreditação da JCI, foi uma opção do Hospital da Boavista baseada na credibilidade e no grau de exigência que a entidade impõe. Foi imperativo que a Unidade de Imagiologia realizasse as suas funções de forma válida e fiável e que disponibilizasse produtos / serviços de qualidade. A monitorização e consequente controlo de qualidade do serviço prestado pela Unidade de Imagiologia, foi difícil mas simplificado, em parte, devido ao sistema de gestão da qualidade ISO 9001:2008 já implementado, tendo este sido consolidado com a implementação da acreditação da JCI, com padrões específicos bem definidos na gestão do controlo de qualidade na Unidade de Imagiologia do Hospital da Boavista.
Resumo:
Adhesive bonding is nowadays a serious candidate to replace methods such as fastening or riveting, because of attractive mechanical properties. As a result, adhesives are being increasingly used in industries such as the automotive, aerospace and construction. Thus, it is highly important to predict the strength of bonded joints to assess the feasibility of joining during the fabrication process of components (e.g. due to complex geometries) or for repairing purposes. This work studies the tensile behaviour of adhesive joints between aluminium adherends considering different values of adherend thickness (h) and the double-cantilever beam (DCB) test. The experimental work consists of the definition of the tensile fracture toughness (GIC) for the different joint configurations. A conventional fracture characterization method was used, together with a J-integral approach, that take into account the plasticity effects occurring in the adhesive layer. An optical measurement method is used for the evaluation of crack tip opening and adherends rotation at the crack tip during the test, supported by a Matlab® sub-routine for the automated extraction of these quantities. As output of this work, a comparative evaluation between bonded systems with different values of adherend thickness is carried out and complete fracture data is provided in tension for the subsequent strength prediction of joints with identical conditions.
Resumo:
Thermally expandable particles (TEPs) are used in a wide variety of applications by industry mainly for weight reduction and appearance improvement for thermoplastics, inks, and coatings. In adhesive bonding, TEPs have been used for recycling purposes. However, TEPs might be used to modify structural adhesives for other new purposes, such as: to increase the joint strength by creating an adhesive functionally modified along the overlap of the joint by gradual heating and/or to heal the adhesive in case of damage. In this study, the behaviour of a structural polyurethane adhesive modified with TEPs was investigated as a preliminary study for further investigations on the potential of TEPs in adhesive joints. Tensile bulk tests were performed to get the tensile properties of the unmodified and TEPs-modified adhesive, while Double Cantilever Beam (DCB) test was performed in order to evaluate the resistance to mode I crack propagation of unmodified and TEPs-modified adhesive. In addition, in order to investigate the behaviour of the particles while encapsulated in adhesives, a thermal analysis was done. Scanning electron microscopy (SEM) was used to examine the fracture surface morphology of the specimens. The fracture toughness of the TEPs-modified adhesive was found to increase by addition of TEPs, while the adhesive tensile strength at yield decreased. The temperature where the particles show the maximum expansion varied with TEPs concentration, decreasing with increasing the TEPs content.
Joint effects of salinity and the antidepressant sertraline on the estuarine decapod Carcinus maenas
Resumo:
Concurrent exposure of estuarine organisms to man-made and natural stressors has become a common occurrence. Numerous interactions of multiple stressors causing synergistic or antagonistic effects have been described. However, limited information is available on combined effects of emerging pharmaceuticals and natural stressors. This study investigated the joint effects of the antidepressant sertraline and salinity on Carcinus maenas. To improve knowledge about interactive effects and potential vulnerability,experiments were performed with organisms from two estuaries with differing histories of exposure to environmental contamination. Biomarkers related to mode of action of sertraline were employed to assess effects of environmentally realistic concentrations of sertraline at two salinity levels. Synergism and antagonism were identified for biomarkers of cholinergic neurotransmission, energy production,anti-oxidant defences and oxidative damage. Different interactions were found for the two study sites highlighting the need to account for differences in tolerance of local ecological receptors in risk evaluations.
Resumo:
Power law (PL) distributions have been largely reported in the modeling of distinct real phenomena and have been associated with fractal structures and self-similar systems. In this paper, we analyze real data that follows a PL and a double PL behavior and verify the relation between the PL coefficient and the capacity dimension of known fractals. It is to be proved a method that translates PLs coefficients into capacity dimension of fractals of any real data.
Resumo:
Mestrado em Engenharia Mecânica
Resumo:
Introdução: No andebol, o ombro é elevado numa amplitude superior a 90º e move-se com elevada velocidade de execução o que pode originar deslocação anterior da cabeça do úmero e diminuição da rotação medial. A técnica MWM pode ser uma mais valia na correção da falha posicional e recuperação da amplitude de movimento de rotação medial da articulação gleno-umeral. Objetivo: Este estudo teve como objetivo verificar os efeitos imediatos da técnica de MWM na amplitude de movimento de rotação medial da articulação gleno-umeral em jogadores de andebol. Métodos: O presente estudo, duplamente cego, é do tipo experimental. Foram incluídos no estudo 30 indivíduos do sexo masculino, jogadores de andebol, distribuídos, aleatoriamente, em dois grupos de 15, experimental e controlo. Em ambos os grupos foi avaliada a amplitude de movimento da rotação medial da gleno-umeral, em dois momentos, pré e pós intervenção. O grupo experimental foi submetido à técnica de MWM no movimento de rotação medial da gleno-umeral no membro dominante. Ao grupo de controlo, foi solicitada a realização do movimento ativo de rotação medial no membro dominante, o fisioterapeuta manteve os mesmos contactos manuais mas não aplicou pressão na cabeça do úmero. Para a comparação entre os grupos experimental e controlo recorreu-se ao teste de Mann-Whitney e para analisar diferenças entre os dois momentos, para cada grupo, foi utilizado o teste de Wilcoxon. Resultados: Foram encontradas diferenças significativas no grupo experimental e controlo, contudo essa diferença foi superior no grupo experimental. Após a intervenção, o grupo experimental apresentou amplitudes de rotação medial da gleno-umeral significativamente mais elevadas às do grupo de controlo (U=0,50; p <0,001). Conclusão: A técnica de MWM para rotação medial produziu um aumento significativo na amplitude desse movimento.
Resumo:
The power systems operation in the smart grid context increases significantly the complexity of their management. New approaches for ancillary services procurement are essential to ensure the operation of electric power systems with appropriate levels of stability, safety, quality, equity and competitiveness. These approaches should include market mechanisms which allow the participation of small and medium distributed energy resources players in a competitive market environment. In this paper, an energy and ancillary services joint market model used by an aggregator is proposed, considering bids of several types of distributed energy resources. In order to improve economic efficiency in the market, ancillary services cascading market mechanism is also considered in the model. The proposed model is included in MASCEM – a multi-agent system electricity market simulator. A case study considering a distribution network with high penetration of distributed energy resources is presented.
Resumo:
The provision of reserves in power systems is of great importance in what concerns keeping an adequate and acceptable level of security and reliability. This need for reserves and the way they are defined and dispatched gain increasing importance in the present and future context of smart grids and electricity markets due to their inherent competitive environment. This paper concerns a methodology proposed by the authors, which aims to jointly and optimally dispatch both generation and demand response resources to provide the amounts of reserve required for the system operation. Virtual Power Players are especially important for the aggregation of small size demand response and generation resources. The proposed methodology has been implemented in MASCEM, a multi agent system also developed at the authors’ research center for the simulation of electricity markets.
Resumo:
O constante desenvolvimento observado nas ligações adesivas, em conjunto com as melhorias verificadas nas características dos adesivos, estão a ser traduzidos, de uma certa forma, num aumento das aplicações das ligações adesivas, assim como na variedade de aplicações. No âmbito da previsão de resistência de juntas adesivas, dois métodos de grande relevância são a Mecânica da Fratura e os Modelos de Dano Coesivo. Os Modelos de Dano Coesivo permitem a simulação da iniciação e propagação do dano, recorrendo ao Método Dos Elementos Finitos. No que concerne à Mecânica da Fratura, a previsão de resistência é geralmente feita através de uma análise energética. Independentemente da forma como é obtida, a taxa crítica de libertação de energia de deformação à tração (GIc) dos adesivos é um dos parâmetros mais importantes para a previsão da resistência das juntas. Dois dos ensaios mais utilizados são o Double Cantilever Beam (DCB) e o Tapered Double Cantilever Beam (TDCB). Este trabalho pretende determinar e comparar o valor de GIc em juntas adesivas pelos ensaios DCB e TDCB. São utilizados três tipos de adesivos com diferentes graus de ductilidade. No ensaio DCB os métodos utilizados para a determinação de GIc são: Compliance-Based Beam Method (CBBM), Corrected Beam Theory (CBT) e Compliance Calibration Method (CCM). Os métodos utilizados no ensaio TDCB são: Simple Beam Theory (SBT), Corrected Beam Theory (CBT) e Compliance Calibration Method (CCM). Os resultados obtidos apresentam concordância entre os vários métodos de cada ensaio. A discrepância de resultados é superior quando comparados os dois tipos de ensaios.
Resumo:
Power law (PL) distributions have been largely reported in the modeling of distinct real phenomena and have been associated with fractal structures and self-similar systems. In this paper, we analyze real data that follows a PL and a double PL behavior and verify the relation between the PL coefficient and the capacity dimension of known fractals. It is to be proved a method that translates PLs coefficients into capacity dimension of fractals of any real data.
Resumo:
O método de união com ligações adesivas está cada vez mais a ser utilizado na conceção de estruturas mecânicas, por causa das vantagens significativas desta técnica em comparação com as ligações tradicionais. De facto, as juntas com ligação adesiva estão sob investigação intensa há bastante tempo. Entre as vantagens, destaca-se a redução de peso e possibilidade de unir diferentes materiais, incluindo compósitos, sem danificar as estruturas a ligar. Os adesivos comerciais variam desde resistentes e frágeis (por exemplo, Araldite® AV138) a menos resistentes e dúcteis (por exemplo, Araldite® 2015). Uma nova família de adesivos de poliuretano combina elevada resistência e ductilidade (por exemplo, Sikaforce® 7888). Este trabalho compara o desempenho à tração dos três adesivos supracitados, em juntas de alumínio (Al6082-T651) de sobreposição simples e dupla, com variação dos valores de comprimento de sobreposição (LO). A análise numérica de modelos de dano coesivo (MDC) foi realizada para analisar as tensões de arrancamento (oy) e as de corte (txy) na camada adesiva, para estudar a variável de dano do MDC durante o processo de rotura e para avaliar a capacidade MDC na previsão da resistência da junta. A análise da resistência e da variável de dano ajudou na compreensão das diferenças entre os adesivos no que se refere ao processo de rotura e resistência da junta. Observou-se que as juntas de sobreposição dupla apresentam uma distribuição de tensões bastante mais favorável relativamente às juntas de sobreposição simples, principalmente devido à eliminação da flexão do substrato interior. Como resultado, a resistência destas juntas foi tipicamente superior ao dobro da observada para as juntas de sobreposição simples, com exceção de algumas configurações de junta em que houve plastificação extensa ou mesmo rotura dos substratos por tração. O trabalho proposto permitiu também concluir que as previsões MDC são tipicamente precisas, e qual a família de adesivos é mais adequada para cada configuração de junta, com a clara vantagem para o Sikaforce® 7888. Como resultado deste trabalho, foram propostas diretrizes de conceção para juntas adesivas.