31 resultados para Air Pollutants


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Every year European citizens become victims of devastating fires, which are especially disastrous for Southern European countries. Apart from the numerous health and economic consequences, fires generate hazardous pollutants that are introduced into the environment, thus representing serious risks for public health. In that regard, particulate matter (PM) is of amajor concern. Thus, the objectives of thisworkwere to characterize the trend of forest fire occurrences and burnt area during the period of 2005 and 2010 and to study the influence of forest fires on levels of particulatematter PM10 and PM2.5. In 2010, 22,026 forest fires occurred in Portugal. The northern region was the most affected by forest fires, with 27% of occurrences in Oporto district. The annual means of PM10 and PM2.5 concentrations at two urban background sites were 25±14 μg mâˆ3 and 8.2±4.9 μg mâˆ3, and 17±13 μg mâˆ3 and 7.3±5.9 μg mâˆ3, respectively. At both sites the highest levels of PMfractionswere observed during July and August of 2010, corresponding to the periods when majority (66%) of forest fires occurred. Furthermore, PM10 daily limit at the two sites was exceeded during 20 and 5 days, respectively; 56%, and respectively 60% of those exceedances occurred during the forest fire season. Considering that the risks of forest fire ignition and severity are enhanced with elevated temperatures, the climate change might increase the environmental impacts of forest fires.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química - Ramo Tecnologias de Protecção Ambiental

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objectivo principal deste trabalho é a realização de uma auditoria, à qualidade do ar interior (QAI), a um edifício de serviços â COCIGA, SA, tendo como base o Regulamento dos Sistemas Energéticos de Climatização dos Edifícios (RSECE). A auditoria QAI implica a medição de vários parâmetros físicos, químicos, microbiológicos e também a inspecção aos componentes do sistema de climatização com a finalidade de averiguar o seu estado de limpeza e manutenção. Assim, foram seleccionados 3 espaços, para a realização de amostragens designados por Comercial - Produtos, AVAC e Mezaninne das oficinas, nos quais foi efectuada a medição de diversos parâmetros, de acordo com as imposições do RSECE, utilizando medidores portáteis ou recorrendo a métodos analíticos. Relativamente aos parâmetros físicos, registaram-se valores de temperatura, para os três espaços estudados, entre os 21 e os 24 ºC e valores médios de humidade relativa de cerca de 50 %. Outro parâmetro medido, e de grande importância para garantir o conforto dos ocupantes, foi a velocidade do ar nos postos de trabalho. De acordo com o RSECE este valor não deve ser superior a 0,2 m/s, o que se verificou em todos os pontos medidos. O último parâmetro físico medido foi a concentração de partículas (PM10) tendo-se obtido valores de cerca de 23 μg/m3ar, valor bastante inferior ao máximo permitido pelo RSECE (150 μg/m3ar). Também no que diz respeito aos parâmetros químicos, ou seja, CO2, CO, formaldeído e ozono, não se verificaram valores superiores aos regulamentares. No caso do CO2, o valor máximo encontrado, nestes três espaços, foi de 745 ppm na Mezaninne das Oficinas e para o CO, na zona AVAC com uma concentração de 0,73 ppm. A medição do formaldeído registou valores perto dos 45 μg/m3ar e o ozono apenas foi detectado, em concentração muito reduzida, na zona Comercial â Produtos. Por fim, as concentrações de bactérias e fungos, de acordo com o RSECE, não devem ultrapassar as 500 UFC/m3ar (parâmetros microbiológicos). Em qualquer dos espaços, os valores medidos foram inferiores ao máximo legal, não ultrapassando as 50 UFC/m3ar. Da avaliação do projecto AVAC, e através da medição dos caudais de insuflação/ extracção em cada zona, concluiu-se que os seus valores não estão de acordo com os valores do projecto inicial que poderá ser imputada a uma insuficiência no funcionamento do sistema detectada na altura das medições. No que diz respeito ao estado de limpeza do sistema AVAC, apenas foi possível inspeccionar as unidades de tratamento de ar, tendo-se constatado que se encontram em boas condições. Ou seja, do ponto de vista do RSECE, e referindo-nos apenas à vertente da Qualidade do Ar Interior, o edifício em causa, cumpre todos os limites impostos para as concentrações de poluentes mas, apresenta algumas deficiências no que respeita aos caudais de ar novo insuflados em cada espaço.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Volatile organic compounds are a common source of groundwater contamination that can be easily removed by air stripping in columns with random packing and using a counter-current flow between the phases. This work proposes a new methodology for the column design for any particular type of packing and contaminant avoiding the necessity of a pre-defined diameter used in the classical approach. It also renders unnecessary the employment of the graphical Eckert generalized correlation for pressure drop estimates. The hydraulic features are previously chosen as a project criterion and only afterwards the mass transfer phenomena are incorporated, in opposition to conventional approach. The design procedure was translated into a convenient algorithm using C++ as programming language. A column was built in order to test the models used either in the design or in the simulation of the column performance. The experiments were fulfilled using a solution of chloroform in distilled water. Another model was built to simulate the operational performance of the column, both in steady state and in transient conditions. It consists in a system of two partial non linear differential equations (distributed parameters). Nevertheless, when flows are steady, the system became linear, although there is not an evident solution in analytical terms. In steady state the resulting system of ODE can be solved, allowing for the calculation of the concentration profile in both phases inside the column. In transient state the system of PDE was numerically solved by finite differences, after a previous linearization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One important step in the design of air stripping operations for the removal of VOC is the choice of operating conditions, which are based in the phase ratio. This parameter sets on directly the stripping factor and the efficiency of the operation. Its value has an upper limit determined by the flooding regime, which is previewed using empirical correlations, namely the one developed by Eckert. This type of approach is not suitable for the development of algorithms. Using a pilot scale column and a convenient solution, the pressure drop was determined in different operating conditions and the experimental values were compared with the estimations. This particular research will be incorporated in a global model for simulating the dynamics of air stripping using a multi variable distributed parameter system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STRIPPING is a software application developed for the automatic design of a randomly packing column where the transfer of volatile organic compounds (VOCs) from water to air can be performed and to simulate itâs behaviour in a steady-state. This software completely purges any need of experimental work for the selection of diameter of the column, and allows a choice, a priori, of the most convenient hydraulic regime for this type of operation. It also allows the operator to choose the model used for the calculation of some parameters, namely between the Eckert/Robbins model and the Billet model for estimating the pressure drop of the gaseous phase, and between the Billet and Onda/Djebbarâs models for the mass transfer. Illustrations of the graphical interface offered are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Volatile organic compounds are a common source of groundwater contamination that can be easily removed by air stripping in columns with random packing and using a counter-current flow between the phases. This work proposes a new methodology for column design for any type of packing and contaminant which avoids the necessity of an arbitrary chosen diameter. It also avoids the employment of the usual graphical Eckert correlations for pressure drop. The hydraulic features are previously chosen as a project criterion. The design procedure was translated into a convenient algorithm in C++ language. A column was built in order to test the design, the theoretical steady-state and dynamic behaviour. The experiments were conducted using a solution of chloroform in distilled water. The results allowed for a correction in the theoretical global mass transfer coefficient previously estimated by the Onda correlations, which depend on several parameters that are not easy to control in experiments. For best describe the column behaviour in stationary and dynamic conditions, an original mathematical model was developed. It consists in a system of two partial non linear differential equations (distributed parameters). Nevertheless, when flows are steady, the system became linear, although there is not an evident solution in analytical terms. In steady state the resulting ODE can be solved by analytical methods, and in dynamic state the discretization of the PDE by finite differences allows for the overcoming of this difficulty. To estimate the contaminant concentrations in both phases in the column, a numerical algorithm was used. The high number of resulting algebraic equations and the impossibility of generating a recursive procedure did not allow the construction of a generalized programme. But an iterative procedure developed in an electronic worksheet allowed for the simulation. The solution is stable only for similar discretizations values. If different values for time/space discretization parameters are used, the solution easily becomes unstable. The system dynamic behaviour was simulated for the common liquid phase perturbations: step, impulse, rectangular pulse and sinusoidal. The final results do not configure strange or non-predictable behaviours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ventilation efficiency concept is an attempt to quantify a parameter that can easily distinguish the different options for air diffusion in the building spaces. Thirteen strategies of air diffusion were measured in a test chamber through the application of the tracer gas method, with the objective to validate the calculation by Computational fluid dynamics (CFD). Were compared the Air Change Efficiency (ACE) and the Contaminant Removal Effectiveness (CRE), the two indicators most internationally accepted. The main results from this work shows that the values of the numerical simulations are in good agreement with experimental measurements and also, that the solutions to be adopted for maximizing the ventilation efficiency should be the schemes that operate with low speeds of supply air and small differences between supply air temperature and the room temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering tobacco smoke as one of the most health-relevant indoor sources, the aim of this work was to further understand its negative impacts on human health. The specific objectives of this work were to evaluate the levels of particulate-bound PAHs in smoking and non-smoking homes and to assess the risks associated with inhalation exposure to these compounds. The developed work concerned the application of the toxicity equivalency factors approach (including the estimation of the lifetime lung cancer risks, WHO) and the methodology established by USEPA (considering three different age categories) to 18 PAHs detected in inhalable (PM10) and fine (PM2.5) particles at two homes. The total concentrations of 18 PAHs (ΣPAHs) was 17.1 and 16.6 ng mâˆ3 in PM10 and PM2.5 at smoking home and 7.60 and 7.16 ng mâˆ3 in PM10 and PM2.5 at non-smoking one. Compounds with five and six rings composed the majority of the particulate PAHs content (i.e., 73 and 78 % of ΣPAHs at the smoking and non-smoking home, respectively). Target carcinogenic risks exceeded USEPA health-based guideline at smoking home for 2 different age categories. Estimated values of lifetime lung cancer risks largely exceeded (68â200 times) the health-based guideline levels at both homes thus demonstrating that long-term exposure to PAHs at the respective levels would eventually cause risk of developing cancer. The high determined values of cancer risks in the absence of smoking were probably caused by contribution of PAHs from outdoor sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prediction of the time and the efficiency of the remediation of contaminated soils using soil vapor extraction remain a difficult challenge to the scientific community and consultants. This work reports the development of multiple linear regression and artificial neural network models to predict the remediation time and efficiency of soil vapor extractions performed in soils contaminated separately with benzene, toluene, ethylbenzene, xylene, trichloroethylene, and perchloroethylene. The results demonstrated that the artificial neural network approach presents better performances when compared with multiple linear regression models. The artificial neural network model allowed an accurate prediction of remediation time and efficiency based on only soil and pollutants characteristics, and consequently allowing a simple and quick previous evaluation of the process viability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A prática de exercício físico é considerado condição essencial para a manutenção de uma boa saúde. A faixa etária de frequentadores de ginásios inclui utentes desde os 8 aos 80 anos, incluindo assim os grupos mais sensíveis à poluição do ar interior. Embora exista legislação específica para ginásios, nomeadamente para as condições de implementação, a mesma é reduzida e não contempla a qualidade do ar interior (QAI). O objetivo geral deste estudo consistiu na avaliação da QAI de quatro ginásios existentes na área metropolitana do Porto. O período de amostragem realizou-se entre 2 de Maio e 20 de Junho 2014 e, após a caracterização dos ginásios, foram monitorizados os seguintes parâmetros: partículas ultrafinas (< 100 nm), matéria particulada suspensa no ar de frações PM1, PM2,5, PM4 e PM10, dióxido de carbono, monóxido de carbono, ozono, compostos orgânicos voláteis, formaldeído, temperatura ambiente e humidade relativa durante 24 h/dia em salas com diferentes actividades (sala de musculação e cardiofitness e sala de aulas de grupo). Os resultados da avaliação dos parâmetros físicos e químicos foram comparados com os limiares de proteção e margem de tolerância do Decreto-Lei nº 118/2013 de 20 de Agosto, a Portaria nº 353-A/2013 de 4 de Dezembro e o Diploma que regula a construção, instalação e funcionamento dos ginásios. Os poluentes com maiores níveis de excedência são o dióxido de carbono, compostos orgânicos voláteis e as partículas PM2,5. As excedências devem-se essencialmente à sobrelotação das salas, excesso de atividade física e ventilação insuficiente. A localização da instalação dos ginásios é também um fator de extrema importância, sendo recomendado que este se situe em local pouco influenciado pelo tráfego automóvel, assim como, afastado de locais de possível interferência devido às atividades presentes, como é o caso da restauração existente em centros comerciais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Demand Response has been taking over the years an extreme importance. Thereâs a lot of demand response programs, one of them proposed in this paper, using air conditioners that could increase the power quality and decrease the spent money in many ways like: infrastructures and customers energy bill reduction. This paper proposes a method and a study on how air conditioners could integrate demand response programs. The proposed method has been modelled as an energy resources management optimization problem. This paper presents two case studies, the first one with all costumers participating and second one with some of costumers. The results obtained for both case studies have been analyzed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aims to characterize levels and phase distribution of polycyclic aromatic hydrocarbons (PAHs) in indoor air of preschool environment and to assess the impact of outdoor PAH emissions to indoor environment. Gaseous and particulate (PM1 and PM2.5) PAHs (16 USEPA priority pollutants, plus dibenzo[a,l]pyrene, and benzo[j]fluoranthene) were concurrently sampled indoors and outdoors in one urban preschool located in north of Portugal for 35 days. The total concentration of 18 PAHs (ΣPAHs) in indoor air ranged from 19.5 to 82.0 ng/m3; gaseous compounds (range of 14.1â66.1 ng/m3) accounted for 85% ΣPAHs. Particulate PAHs (range 0.7â15.9 ng/m3) were predominantly associated with PM1 (76% particulate ΣPAHs) with 5-ring PAHs being the most abundant. Mean indoor/outdoor ratios (I/O) of individual PAHs indicated that outdoor emissions significantly contributed to PAH indoors; emissions from motor vehicles and fuel burning were the major sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because of the scientific evidence showing that arsenic (As), cadmium (Cd), and nickel (Ni) are human genotoxic carcinogens, the European Union (EU) recently set target values for metal concentration in ambient air (As: 6 ng/m3, Cd: 5 ng/m3, Ni: 20 ng/m3). The aim of our study was to determine the concentration levels of these trace elements in Porto Metropolitan Area (PMA) in order to assess whether compliance was occurring with these new EU air quality standards. Fine (PM2.5) and inhalable (PM10) air particles were collected from October 2011 to July 2012 at two different (urban and suburban) locations in PMA. Samples were analyzed for trace elements content by inductively coupled plasmaâmass spectrometry (ICP-MS). The study focused on determination of differences in trace elements concentration between the two sites, and between PM2.5 and PM10, in order to gather information regarding emission sources. Except for chromium (Cr), the concentration of all trace elements was higher at the urban site. However, results for As, Cd, Ni, and lead (Pb) were well below the EU limit/target values (As: 1.49 ± 0.71 ng/m3; Cd: 1.67 ± 0.92 ng/m3; Ni: 3.43 ± 3.23 ng/m3; Pb: 17.1 ± 10.1 ng/m3) in the worst-case scenario. Arsenic, Cd, Ni, Pb, antimony (Sb), selenium (Se), vanadium (V), and zinc (Zn) were predominantly associated to PM2.5, indicating that anthropogenic sources such as industry and road traffic are the main source of these elements. High enrichment factors (EF > 100) were obtained for As, Cd, Pb, Sb, Se, and Zn, further confirming their anthropogenic origin.