51 resultados para unregulated pollutants
Resumo:
This work deals with the numerical simulation of air stripping process for the pre-treatment of groundwater used in human consumption. The model established in steady state presents an exponential solution that is used, together with the Tau Method, to get a spectral approach of the solution of the system of partial differential equations associated to the model in transient state.
Resumo:
This work deals with the numerical simulation of air stripping process for the pre-treatment of groundwater used in human consumption. The model established in steady state presents an exponential solution that is used, together with the Tau Method, to get a spectral approach of the solution of the system of partial differential equations associated to the model in transient state.
Resumo:
Dissertação para a obtenção do Grau de Mestre em Contabilidade e Finanças Orientador: Mestre Adalmiro Álvaro Malheiro de Castro Andrade Pereira
Resumo:
Os Bombeiros estão expostos frequentemente a vários poluentes prejudicando gravemente a sua saúde respiratória. Foi realizado um estudo observacional e transversal, com o objectivo de caracterizar a função pulmonar dos bombeiros da região norte de Portugal. A amostra foi constituída por 44 Bombeiros de Valongo e Rebordosa. Todos os participantes preencheram um questionário, executaram espirometrias e mediram o monóxido de carbono. Verificou-se uma elevada prevalência de hábitos tabágicos, bem como da carga tabágica. A percentagem de alterações espirométricas foi de 38,6% e a utilização de protecção respiratória revelou-se praticamente inexistente nos incêndios florestais.
Resumo:
An accurate and sensitive method for determination of 18 polycyclic aromatic hydrocarbons (PAHs) (16 PAHs considered by USEPA as priority pollutants, dibenzo[a,l]pyrene and benzo[j]fluoranthene) in fish samples was validated. Analysis was performed by microwave-assisted extraction and liquid chromatography with photodiode array and fluorescence detection. Response surface methodology was used to find the optimal extraction parameters. Validation of the overall methodology was performed by spiking assays at four levels and using SRM 2977. Quantification limits ranging from 0.15–27.16 ng/g wet weight were obtained. The established method was applied in edible tissues of three commonly consumed and commercially valuable fish species (sardine, chub mackerel and horse mackerel) originated from Atlantic Ocean. Variable levels of naphthalene (1.03–2.95 ng/g wet weight), fluorene (0.34–1.09 ng/g wet weight) and phenanthrene (0.34–3.54 ng/g wet weight) were detected in the analysed samples. None of the samples contained detectable amounts of benzo[a]pyrene, the marker used for evaluating the occurrence and carcinogenic effects of PAHs in food.
Resumo:
Mestrado em Engenharia Química.Ramo Tecnologias de Protecção Ambiental
Resumo:
Mestrado em Engenharia Química. Ramo Tecnologias de Protecção Ambiental.
Resumo:
Mestrado em Engenharia Química. Ramo Tecnologias de Protecção Ambiental.
Resumo:
Actualmente, a poluição do ar, água e solo são problemáticas nas quais se têm centrado diversos estudos. Reduzir ou eliminar a concentração dos diversos poluentes presentes nestes meios é uma meta que se pretende atingir. Neste âmbito, têm sido desenvolvidos diversos estudos e trabalhos, utilizando diversas tecnologias, como químicas e biológicas, de forma a conseguir-se atingir este fim. Esta tese teve como principal objectivo estudar a remediação de solos contaminados com produtos farmacêuticos recorrendo à oxidação/redução química. Assim, começou por se estudar a remediação de água contaminada com ibuprofeno, uma vez, que a matriz líquida é mais fácil de estudar que o solo. Neste âmbito escolheram-se os seguintes reagentes para estudar a descontaminação da água: permanganato de potássio, reagente de Fenton e nanopartículas de ferro zero valente. Analisando os resultados obtidos nestas análises, verificou-se que o permanganato de potássio não foi capaz de reduzir a concentração de ibuprofeno presente na água. No entanto, o reagente de Fenton e as nanopartículas produzidas a partir do extracto da casca de castanha e do chá conseguirem reagir com o ibuprofeno, apresentando taxas de degradação de 90 % e 77 %, respectivamente, nas melhores condições experimentadas. Com os resultados obtidos, passou-se a analisar solos contaminados com o ibuprofeno, utilizando o reagente de Fenton e as nanopartículas produzidas a partir de um extracto de chá. Verificou-se que estes reagentes conseguiram reduzir a concentração de ibuprofeno presente no solo (areia) para valores residuais, obtendo-se taxas de degradação acima de 95 % após 5 dias de reacção. Conclui-se que, o objectivo principal desta tese foi cumprido pois foi reduzida, e quase eliminada, a concentração do ibuprofeno presente no solo, recorrendo à oxidação/redução química.
Resumo:
De forma a proteger o ambiente e a saúde humana, é imperativo evitar, prevenir ou reduzir as concentrações prejudiciais de poluentes nocivos na água subterrânea. A necessidade da obtenção de níveis de protecção da água subterrânea, encontra-se estabelecida em normas de qualidade e devem ser desenvolvidas metodologias que permitam a avaliação do estado químico da água subterrânea. Este trabalho experimental centrou-se no desenvolvimento de uma metodologia analítica de detecção e quantificação por cromatografia gasosa com detector de captura de electrões dos pesticidas atrazina e respectivos metabolitos (desetilatrazina e deisopropilatrazina), simazina, terbutilazina e o metabolito desetiterbutilazina, folpete, dimetoato, diazinão, malatião, cloropirifos e o azinfos-metilo em águas de poços. O estudo progressivo baseou-se na colheita de água a 20 poços agrícolas na zona de Esposende, área considerada pelo Ministério da Agricultura do Desenvolvimento Rural e Pescas como sendo uma zona vulnerável. O método utilizado para a validação da técnica cromatográfica baseou-se na norma ISO 8466-1:1990. Os parâmetros de validação considerados foram: especificidade/selectividade, capacidade de identificação, limites de detecção e quantificação, relação sinal/ruído, linearidade e curva de calibração, precisão (repetibilidade, precisão intermédia e reprodutibilidade), eficiência de extracção e arrastamento. O método demonstrou ser capaz de identificar e quantificar os analitos, sem interferência de outros compostos. Obteve-se um valor para os parâmetros da precisão inferior a 10%, enquanto os mais baixos limites de detecção e de quantificação foram, respectivamente, 0,014 e 0,047 μg L-1. Na preparação de amostras optou-se pelo método de extracção em fase sólida, tendo sido testadas cinco diferentes tipos de colunas extractivas; Lichrolut® EN/RP-18; Strata SDB-L e C18-E; Chromabond HR-P e HR-X, sendo que as colunas Lichrolut® EN/RP- 18 apresentaram melhores resultados para a globalidade dos pesticidas. Da análise efectuada aos 20 poços agrícolas verificou-se que apenas 3 não apresentavam qualquer vestígio dos pesticidas monitorizados, sendo que as restantes apresentavam valores entre 0,05 e 53,2 μg L-1, valores superiores aos impostos pela legislação em vigor (Decreto-Lei n.º 208/2008 de 28 de Outubro para água subterrânea e Decreto-Lei nº306/2007 referente a água para consumo). Verificou-se que os proprietários dos poços agrícolas, dos quais se procedeu à amostragem de água para análise não têm a consciência da falta de qualidade dessa água, nem dos malefícios que possam advir do seu consumo.
Resumo:
Neste trabalho estudou-se a implementação de um sistema de vigilância e alerta da qualidade da água de um recurso hídrico, para um possível caso de poluição. Em 25 de Agosto de 2008 foram derramadas 4 toneladas de ácido clorídrico acidentalmente para as águas do rio Febros. Este rio situa-se no concelho de Vila Nova de Gaia e é um pequeno afluente do rio Douro, tendo cerca de 14 km de extensão e tem a particularidade de atravessar o Parque Biológico de Gaia. A falta de uma rápida intervenção e da existência de um plano de ação levou a que parte da fauna e flora fosse destruída. Por este motivo realizou-se este estudo que se baseou na criação de um sistema de vigilância e alerta a ser implementado neste rio. A informação da hidrogeometria do rio e da capacidade de transporte e dispersão de poluentes é indispensável para o bom funcionamento deste sistema. O coeficiente de dispersão longitudinal é um parâmetro muito importante no estudo da qualidade da água. Recorreu-se à utilização da Rodamina WT como marcador, determinando assim a evolução da sua concentração ao longo do tempo e espaço. No cálculo do coeficiente de dispersão foi utilizado o modelo Transient Storage, que demonstrou ser um bom modelo de ajuste aproximando-se dos valores medidos em campo. Para três estações diferentes com distâncias de 290, 390 e 1100 metros do ponto de injeção, obtiveram-se valores de coeficiente de dispersão de 0,18, 0,15 e 0,39 m2/s respetivamente. Os valores do ajuste expressos sob a forma de coeficiente de correlação foram 0,988, 0,998 e 0,986, para a mesma ordem de estações. A constante de rearejamento do rio foi também determinada recorrendo ao método dos marcadores inertes, utilizando o propano como marcador gasoso. A constante determinada próximo de Casal Drijo, entre 2 estações de amostragem a 140 e 290 m do local de injeção, foi de 13,4 dia-1. Com os resultados do coeficiente de dispersão e da constante de rearejamento para além da velocidade e caudal da corrente do rio conseguir-se-á construir o modelo de simulação e previsão de um possível poluente. O sistema de vigilância a implementar sugere-se assim que seja construído por duas partes, uma de análise de evolução da nuvem de poluição e plano de ação outra de monitorização contínua e emissão de alerta. Após uma análise do investimento à implementação deste sistema chegou-se à conclusão que o valor de investimento é de 15.182,00 €.
Resumo:
The presented work was conducted within the Dissertation / Internship, branch of Environmental Protection Technology, associated to the Master thesis in Chemical Engineering by the Instituto Superior de Engenharia do Porto and it was developed in the Aquatest a.s, headquartered in Prague, in Czech Republic. The ore mining exploitation in the Czech Republic began in the thirteenth century, and has been extended until the twentieth century, being now evident the consequences of the intensive extraction which includes contamination of soil and sub-soil by high concentrations of heavy metals. The mountain region of Zlaté Hory was chosen for the implementation of the remediation project, which consisted in the construction of three cells (tanks), the first to raise the pH, the second for the sedimentation of the formed precipitates and a third to increase the process efficiency in order to reduce high concentrations of metals, with special emphasis on iron, manganese and sulfates. This project was initiated in 2005, being pioneer in this country and is still ongoing due to the complex chemical and biological phenomenon’s inherent to the system. At the site where the project was implemented, there is a natural lagoon, thereby enabling a comparative study of the two systems (natural and artificial) regarding the efficiency of both in the reduction/ removal of the referred pollutants. The study aimed to assist and cooperate in the ongoing investigation at the company Aquatest, in terms of field work conducted in Zlaté Hory and in terms of research methodologies used in it. Thereby, it was carried out a survey and analysis of available data from 2005 to 2008, being complemented by the treatment of new data from 2009 to 2010. Moreover, a theoretical study of the chemical and biological processes that occurs in both systems was performed. Regarding the field work, an active participation in the collection and in situ sample analyzing of water and soil from the natural pond has been attained, with the supervision of Engineer, Irena Šupiková. Laboratory analysis of water and soil were carried out by laboratory technicians. It was found that the natural lagoon is more efficient in reducing iron and manganese, being obtained removal percentages of 100%. The artificial lagoon had a removal percentage of 90% and 33% for iron and manganese respectively. Despite the minor efficiency of the constructed wetland, it must be pointed out that this system was designed for the treatment and consequent reduction of iron. In this context, it can conclude that the main goal has been achieved. In the case of sulphates, the removal optimization is yet a goal to be achieved not only in the Czech Republic but also in other places where this type of contamination persists. In fact, in the natural lagoon and in the constructed wetland, removal efficiencies of 45% and 7% were obtained respectively. It has been speculated that the water at the entrance of both systems has different sources. The analysis of the collected data shows at the entrance of the natural pond, a concentration of 4.6 mg/L of total iron, 14.6 mg/L of manganese and 951 mg/L of sulphates. In the artificial pond, the concentrations are 27.7 mg/L, 8.1 mg/L and 382 mg/L respectively for iron, manganese and sulphates. During 2010 the investigation has been expanded. The study of soil samples has started in order to observe and evaluate the contribution of bacteria in the removal of heavy metals being in its early phase. Summarizing, this technology has revealed to be an interesting solution, since in addition to substantially reduce the mentioned contaminants, mostly iron, it combines the low cost of implementation with an reduced maintenance, and it can also be installed in recreation parks, providing habitats for plants and birds.
Resumo:
Na procura por uma solução de valorização dos resíduos gerados pela indústria de curtumes, o presente trabalho tem como principais objectivos a preparação de adsorventes a partir de resíduos desta actividade e a avaliação do seu desempenho na adsorção de poluentes. Para atingir este objectivo, inicialmente procedeu-se à carbonização das aparas de couro wet-white à temperatura de 800 ºC. Seguidamente, os carbonizados foram activados por activação química, tendo sido o hidróxido de potássio o agente activante escolhido. As razões mássicas hidróxido de potássio:precursor usadas na impregnação, foram iguais a 0,5:1 e 1:1. Para a razão 0,5:1, as temperaturas de activação escolhidas foram 700 e 800 ºC. Para a razão de impregnação 1:1, as temperaturas de activação usadas foram 700, 800 e 900 ºC. Para uma avaliação preliminar da capacidade de adsorção dos carvões activados produzidos, efectuou-se a determinação do número de azul de metileno. Este teste provou serem as amostras activadas a 900 ºC as que apresentaram melhores resultados (número de azul de metileno: 24g/100g) e as amostras activadas a 700 ºC, as que apresentaram menor capacidade de adsorção (1g/100g, para a razão de 0,5:1 e 7g/100g, para a razão de 1:1). Verificou-se também que amostras preparadas com iguais condições de activação (temperatura de activação e razão de impregnação), mas produzidas a partir de carbonizado de diferentes granulometrias, apresentaram diferentes desempenhos na adsorção de azul de metileno. As propriedades texturais dos carvões activados produzidos foram obtidas pela determinação das isotérmicas de adsorção de azoto a 77 K. Para tal, selecionaram-se quatro amostras: dois carvões activados a 800 ºC, com uma razão de impregnação de 1:1 e dois carvões activados a 900 ºC, com a mesma razão de impregnação, obtidos a partir de carbonizados com diferentes granulometrias. As isotérmicas obtidas são características de materiais essencialmente microporosos, com mesoporos e macroporos. Verificou-se também que a granulometria do precursor carbonizado influencia as propriedades texturais dos carvões activados produzidos. Para as temperaturas de activação usadas, 800 e 900 ºC, os carvões activados preparados a partir de carbonizado de menor granulometria apresentam melhores propriedades texturais. O carvão activado que apresentou maior área superficial específica foi obtido a 900 ºC, a partir de carbonizado finamente moído (SBET = 1475 m2/g). Determinadas as propriedades texturais dos carvões activados produzidos, realizaram-se ensaios de adsorção do corante CORIACIDE DARK BROWN VR, usado na indústria de curtumes com um carvão activado produzido no âmbito deste trabalho e com um carvão activado comercial NORIT ROW 0,8. A amostra de carvão activado produzida a partir de resíduos de wet-white escolhida para estes ensaios foi o carvão activado a 800 ºC, à razão de 1:1, a partir de carbonizado finamente moído (ww_800_1:1_carb.moído). Verificou-se que as quantidades adsorvidas pela amostra ww_800_1:1_carb.moído variaram entre os valores 7,47 e 32,07 mgcorante/gcarvão activado. Quanto ao carvão activado comercial, as quantidades adsorvidas situaram-se entre 8,95 e 69,13 mgcorante/gcarvão activado. Assim, conclui-se que o carvão activado comercial apresentou melhor desempenho na adsorção do corante da indústria de curtumes. Os carvões activados obtidos revelaram-se materiais essencialmente microporosos, com capacidade de adsorção de poluentes, como por exemplo corantes, no entanto o seu desempenho seria mais eficaz na adsorção de pequenas moléculas devido ao elevado volume de microporos que apresentaram.
Resumo:
The goal of this work was the treatment of polluted waste gases in a bubble column reactor (BCR), in order to determinate the maximum value of reactor’s efficiency (RE), varying the inlet concentration (C in) of the pollutants. The gaseous mixtures studied were: (i) air with styrene and (ii) air with styrene and acetone. The liquid phase used to contain the biomass in the reactor was a basal salt medium (BSM), fundamental for the microorganisms’ development. The reactor used in this project consists of a glass column of 620mm height and inside diameter 75mm. In all essays there were continually measured: pH, dissolved oxygen and liquid’s temperature. Temperature and pH were controlled (T=24ºC, 7.0 ≤ pH ≤ 7.7). In all experiments the liquid volume (including the biomass) used in the reactor was kept constant (1.5L) as well as the total gas flowrate (1 L/min). Concerning the goal of the work, some parameters were calculated: the organic load (OL), removal efficiency (RE), elimination capacity (EC), biomass concentration (xf) and dry biomass concentration (Xdw). In a first series of experiments, the gas mixture used was air with styrene, varying its concentration from 191 mg.m-3 to 6500 mg.m-3.It was concluded that the RE maximum value (97%) was obtained for C in Sty = 4200 mg.m-3. For the maximum tested value of C in Sty, RE obtained was 20%. In a second step, the gaseous mixture included acetone, varying C in Sty between 225 mg.m-3 and 2659 mg.m-3 and C in Ac between 153mg.m-3 and 1389 mg.m-3. The aim of these tests was the determination of C in Ac for which RE was maximum, obtaining C in Ac = 750 mg.m-3. A third series of experiments was performed, in which C in Ac was maintained equal to that value and C in Sty was varied until higher values (5422 mg.m-3). RE maximum values obtained in this last series were 100% for styrene and 40% for acetone. One important conclusion is the fact that the microorganisms available degrade better styrene than acetone. On the ambit of this study, it was possible to identify the species available in biomass: Xanthobacter antotrophicus py2, Enterobacter aerogenes, Nocardia, Corynebacterium Spp., Rhodococcus rhodochrous e Pseudomonas Sp.
Resumo:
Os produtos farmacêuticos são substâncias químicas muito utilizados em medicina, veterinária e ainda na agricultura. Nos anos 90, foi descoberta a presença de fármacos em meio aquático, verificando-se que a sua remoção nas Estações de Tratamento de Águas Residuais (ETAR) não era completa. Durante as duas últimas décadas foi identificada a presença de mais de oitenta compostos no meio ambiente e actualmente são considerados poluentes emergentes. Podem contaminar solos e águas, depois de serem usados e excretados (inalterados ou metabolizados) por humanos e animais, ou quando são indevidamente lançados directamente no meio ambiente. Os estudos ecotoxicológicos efectuados com estes poluentes têm sido direccionados, sobretudo, para as águas, existindo uma ausência de trabalhos sobre solos. O Ibuprofeno (IB) é um anti-inflamatório não esteróide, utilizado também como analgésico e antipirético, sendo um dos produtos farmacêuticos mais vendidos em todo o mundo, o que justifica a sua forte presença no meio ambiente. Por isso, e dada a ausência de trabalhos ecotoxicológicos de solos contaminados por fármacos, o IB foi o produto farmacêutico selecionado para a realização deste trabalho. A ecotoxicidade pode ser avaliada através de bioensaios. Estes têm a capacidade de avaliar a toxicidade de uma determinada substância de forma global, usando organismos vivos que funcionam como bio-indicadores. O presente trabalho tem como objectivos avaliar o impacte causado nos solos pelo IB, testar a toxicidade de dois processos de descontaminação para remover o referido fármaco dos solos assim como avaliar a toxicidade provocada por águas residuais, de três unidades hospitalares e de uma indústria farmacêutica. Esta avaliação foi efectuada através de ensaios de toxicidade aguda de germinação e de alongamento de raiz de sementes de alface, variedade bola de manteiga (Lactuca sativa), em solo arenoso. Os ensaios de ecotoxicidade aguda em solos contaminados por IB foram realizados para uma gama de concentrações entre 0,1 e 1000 μg/L. Verificou-se uma redução do número de sementes germinadas e do comprimento médio da planta no solo contaminado com 0,5 e 20 μg/L de IB. No solo contaminado com 1000 μg/L de IB observou-se uma redução da germinação, acompanhada por uma indução de crescimento da raiz da espécie Lactuca sativa. Os dois tratamentos de descontaminação de solos, reagente de Fenton e Nanopartículas de ferro zero valente, revelaram toxicidade, tendo-se obtido uma percentagem de germinação entre 32,2 ± 3,5 e 48,5 ± 6,2 e inibição do crescimento da raiz do organismo teste em cerca de 85,0 %. Em relação às águas residuais hospitalares verificou-se uma redução da percentagem de germinação entre 31,1 ± 5,0 e 72,3 ± 12,4 e uma inibição do crescimento da raiz situada entre 13,0 ± 6,4 e 20,2 ± 10,0 %. Para a água residual industrial ocorreu uma inibição da percentagem de germinação de 60,5 ± 13,1, contudo nas plantas germinadas observou-se uma indução do crescimento da raiz de 14,9 ± 7,7 %.