27 resultados para LABORATORY TEST
em Reposit
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
This paper studies the application of commercial biocides to old maritime pine timber structures (Pinus pinaster Ait.) that have previously been impregnated with other products. A method was developed in the laboratory to be used in situ to determine the impregnation depth achieved by a new generation biocide product applied to timber from an old building. This timber had once been treated with an unknown product difficult to characterize without extensive analysis. The test was initially developed in laboratory conditions and later tested on elements of the roof structure of an 18th century building. In both cases the results were promising and mutually consistent with penetration depths for some treatments reaching 2.0 cm. The application in situ proved the tests viability and simplicity of execution giving a clear indication on the feasibility of possible re-treatments.
Resumo:
This paper concerns the study of biocides application in old timber structures of maritime pine (Pinus pinaster Ail.), previously impregnated with other products. A method was developed in laboratory to determine in situ the penetration depth of a product applied superficially. As initial treatment, three traditional products for sawn timber for buildings were used and, for new treatments, two newer, more environmentally benign products were used. Their ability to penetrate the pre-treated surfaces was evaluated after 1, 2 and 3 applications at 24 hours intervals and the results obtained are presented. Finally, the applicability of the developed test to the in-situ evaluation of timber structures is also discussed.
Resumo:
This article describes an experimental study on ash deposition during the co-firing of bituminous coal with pine sawdust and olive stones in a laboratory furnace. The main objective of this study was to relate the ash deposit rates with the type of biomass burned and its thermal percentage in the blend. The thermal percentage of biomass in the blend was varied between 10% and 50% for both sawdust and olive stones. For comparison purposes, tests have also been performed using only coal or only biomass. During the tests, deposits were collected with the aid of an air-cooled deposition probe placed far from the flame region, where the mean gas temperature was around 640 degrees C. A number of deposit samples were subsequently analyzed on a scanning electron microscope equipped with an energy dispersive X-ray detector. Results indicate that blending sawdust with coal decreases the deposition rate as compared with the firing of unblended coal due to both the sawdust low ash content and its low alkalis content. The co-firing of coal and sawdust yields deposits with high levels of silicon and aluminium which indicates the presence of ashes with high fusion temperature and, thus, with less capacity to adhere to the surfaces. In contrast, in the co-firing of coal with olive stones the deposition rate increases as compared with the firing of unblended coal and the deposits produced present high levels of potassium, which tend to increase their stickiness.
Resumo:
O trabalho apresentado nesta dissertação refere-se à concepção, projecto e realização experimental de um conversor estático de potência tolerante a falhas. Foram analisados trabalhos de investigação sobre modos de falha de conversores electrónicos de potência, topologias de conversores tolerantes a falhas, métodos de detecção de falhas, entre outros. Com vista à concepção de uma solução, foram nomeados e analisados os principais modos de falhas para três soluções propostas de conversores com topologias tolerantes a falhas onde existem elementos redundantes em modo de espera. Foram analisados os vários aspectos de natureza técnica dos circuitos de potência e guiamento de sinais onde se salientam a necessidade de tempos mortos entre os sinais de disparo de IGBT do mesmo ramo, o isolamento galvânico entre os vários andares de disparo, a necessidade de minimizar as auto-induções entre o condensador DC e os braços do conversor de potência. Com vista a melhorar a fiabilidade e segurança de funcionamento do conversor estático de potência tolerante a falhas, foi concebido um circuito electrónico permitindo a aceleração da actuação normal de contactores e outro circuito responsável pelo encaminhamento e inibição dos sinais de disparo. Para a aplicação do conversor estático de potência tolerante a falhas desenvolvido num accionamento com um motor de corrente contínua, foi implementado um algoritmo de controlo numa placa de processamento digital de sinais (DSP), sendo a supervisão e actuação do sistema realizados em tempo-real, para a detecção de falhas e actuação de contactores e controlo de corrente e velocidade do motor utilizando uma estratégia de comando PWM. Foram realizados ensaios que, mediante uma detecção adequada de falhas, realiza a comutação entre blocos de conversores de potência. São apresentados e discutidos resultados experimentais, obtidos usando o protótipo laboratorial.
Resumo:
A maioria das infra-estruturas de transportes, nomeadamente os pavimentos rodoviários e aeroportuários, são constituídas por misturas betuminosas, o que permite um bom desempenho e uma adequada durabilidade, nas condições usuais de serviço. As misturas betuminosas são ainda amplamente utilizadas na construção de zonas de estacionamento de veículos, tendo-se verificado recentemente a sua aplicação também em infra-estruturas ferroviárias. Face à necessidade de melhorar o desempenho das vias-férreas, permitindo uma concepção mais durável de linhas de alta velocidade e uma redução dos custos da sua manutenção, tem-se vindo a desenvolver diversos estudos para promover a utilização de novos materiais, principalmente através da incorporação de misturas betuminosas. O presente trabalho tem como objectivo a caracterização do comportamento mecânico de misturas betuminosas a aplicar em infra-estruturas de transportes. Como metodologia para o estudo do comportamento mecânico das misturas betuminosas foram realizados em laboratório ensaios de cargas repetidas, nomeadamente, ensaios de flexão em quatro pontos para determinação da rigidez e da resistência à fadiga e ensaios de compressão triaxiais cíclicos para avaliação do comportamento à deformação permanente. A resistência à fadiga das misturas betuminosas em estudo foi avaliada através do ensaio de flexão em quatro pontos, com extensão controlada, e aplicação de um carregamento sinusoidal com diferentes frequências, de acordo com o procedimento de ensaio da norma europeia EN 12697-24 (2004 + A1: 2007). A resistência à deformação permanente das misturas betuminosas foi analisada através de ensaios de compressão triaxiais cíclicos, submetendo-as a uma tensão de confinamento estática pela aplicação parcial de vácuo e a uma pressão axial cíclica sob a forma rectangular, de acordo com a norma europeia EN 12697-25 (2004). O conhecimento destas propriedades mecânicas assume particular importância ao nível da formulação das misturas betuminosas, do dimensionamento de uma estrutura ou do estabelecimento de uma adequada solução para uma obra de reabilitação duma infra-estrutura de transportes. Para este estudo foi utilizado um modelo físico construído numa fossa no LNEC, com o propósito de serem testadas três substruturas ferroviárias não convencionais, utilizando sub-balastro betuminoso. A selecção das substruturas foi efectuada após uma análise de várias secções de estruturas já testadas e aplicadas noutros países, de forma a proporcionar comparações fiáveis entre elas. Os resultados obtidos mostraram que a mistura betuminosa AC20 base 50/70 (MB) aplicada na camada de sub-balastro é adequada para ser aplicada nas infra-estruturas de transportes pois apresenta um bom desempenho à fadiga e à deformação permanente. Através dos ensaios efectuados foi ainda possível entender a importante influência das características volumétricas, principalmente da porosidade para o bom comportamento da mistura betuminosa.
Resumo:
When a paleomagnetic pole is sought for in an igneous body, the host rocks should be subjected to a contact test to assure that the determined paleopole has the age of the intrusion. If the contact test is positive, it precludes the possibility that the measured magnetization is a later effect. Therefore, we investigated the variations of the remanent magnetization along cross-sections of rocks hosting the Foum Zguid dyke (southern Morocco) and the dyke itself. A positive contact test was obtained, but it is mainly related with Chemical/Crystalline Remanent Magnetization due to metasomatic processes in the host-rocks during magma intrusion and cooling, and not only with Thermo-Remanent Magnetization as ordinarily assumed in standard studies. Paleomagnetic data obtained within the dyke then reflect the Earth magnetic field during emplacement of this well-dated (196.9 +/- 1.8 Ma) intrusion.
Resumo:
The aim of the study is to adapt and then discuss the appropriateness of the Life Orientation Test as a one or two dimension scale. The research includes two studies; one is composed of a sequential sample of 280 people with multiple sclerosis, 71% female, and another includes a convenience sample of 615 individuals from the community, 51.1% female. Because the construct is built upon a theoretical assumption that has one dimension, we examine the hypothesis of one or two factor solutions through confirmatory factor analysis, and the two-dimension solution premise demonstrates better adjustment for both samples. The other psychometric properties explored show appropriate results for the Portuguese sample, and similar to the original ones; the Test therefore seems appropriate for use in cross cultural studies. Based on our results, we discuss whether the questionnaire is a one or two dimension instrument, concluding that it appears appropriate to accept the recommendations of the original authors to use it as a one-dimensional tool and, when necessary, to use both dimensions. - RESUMO: El objetivo del estudio es adaptar y discutir la adecuación de la prueba de Orientación de la Vida en una o dos escalas de dimensión. La investigación engloba dos estudios, uno constituido por una muestra secuencial de 280 personas con esclerosis múltiple, 71% mujeres y otro con una muestra de conveniencia de la comunidad de 615 individuos, 51,1% del sexo femenino. Como el constructo se asienta sobre la presunción teórica de que tiene una dimensión, inspeccionamos la hipótesis de una o dos soluciones de factor a través del análisis factorial confirmatorio y la hipótesis de dos dimensiones manifiesta un mejor ajuste para ambas muestras. Las otras propiedades psicométricas exploradas muestran los resultados apropiados para la muestra portuguesa, y semejantes a los originales. Parece apropiado para los estudios culturales transversales. Basándonos en nuestros resultados, discutimos si el cuestionario es un instrumento de una o dos dimensiones, concluyéndose que parece conveniente seguir las recomendaciones de los autores originales, para utilizarlo como un instrumento unidimensional y, si fuera necesario necesario, utilizar cada una de las dimensiones.
Resumo:
A test chamber was projected and built (according to ISO 16000-9 Standard) to simulate atmospheric conditions experienced by rubber infill (when applied in synthetic turf pitches) and measure accurately the airborne emissions of pollutants such as dusts and volatile organic compounds (VOC), as well as pollutants present in leachates. It should be pointed out that standard ISO 16000-9 is only concerned with the determination of the emission of VOC from building products and furnishing (not specific of synthetic turf materials), whereas other standards are concerned with the emission of leachates only. This procedure is to be considered as a technical option to the lysimeter "global turf system evaluation" when the rubber infill alone is to be evaluated. The advantage of the proposed option considering this "test chamber" is its simplicity and economy. This test chamber is actually installed and being used for tests in LAIST.
Resumo:
Physical function is limited post-liver transplantation and exercise training can improve exercise capacity following transplantation but previously assessment of functional capacity is necessary. The 6 minute walk test (6MWT) is routinely used for studying patient’s exercise capacity and is less expensive and time consuming than a Cardiopulmonary Exercise Test (CPXT). There have been some studies looking at the relationship between 6MWT and peak VO2 in patients but few presented an adequate equation for predicted peak VO2 from 6MWT to transplanted patients and none for Familial Amyloidotic Polyneuropathy (FAP) liver transplanted patients (FAPTx). The aim of this study was to compare the validity of 6 equations as predictors of VO2 from the 6MWT and compare it with directly measured VO2 in patients FAPTx.
Resumo:
The aim of the present study was to test a hypothetical model to examine if dispositional optimism exerts a moderating or a mediating effect between personality traits and quality of life, in Portuguese patients with chronic diseases. A sample of 540 patients was recruited from central hospitals in various districts of Portugal. All patients completed self-reported questionnaires assessing socio-demographic and clinical variables, personality, dispositional optimism, and quality of life. Structural equation modeling (SEM) was used to analyze the moderating and mediating effects. Results suggest that dispositional optimism exerts a mediator rather than a moderator role between personality traits and quality of life, suggesting that “the expectation that good things will happen” contributes to a better general well-being and better mental functioning.
Resumo:
IBD is a gastro-intestinal disorder marked with chronic inflammation of intestinal epithelium, damaging mucosal tissue and manifests into several intestinal and extra-intestinal symptoms. Currently used medical therapy is able to induce and maintain the patient in remission, however no modifies or reverses the underlying pathogenic mechanism. The research of other medical approaches is crucial to the treatment of IBD and, for this, it´s important to use animal models to mimic the characteristics of disease in real life. The aim of the study is to develop an animal model of TNBS-induced colitis to test new pharmacological approaches. TNBS was instilled intracolonic single dose as described by Morris et al. It was administered 2,5% TNBS in 50% ethanol through a catheter carefully inserted into the colon. Mice were kept in a Tredelenburg position to avoid reflux. On day 4 and 7, the animals were sacrificed by cervical dislocation. The induction was confirmed based on clinical symptoms/signs, ALP determination and histopathological analysis. At day 4, TNBS group presented a decreased body weight and an alteration of intestinal motility characterized by diarrhea, severe edema of the anus and moderate morbidity, while in the two control groups weren’t identified any alteration on the clinical symptoms/signs with an increase of the body weight. TNBS group presented the highest concentrations of ALP comparing with control groups. The histopathology analysis revealed severe necrosis of the mucosa with widespread necrosis of the intestinal glands. Severe hemorrhagic and purulent exsudates were observed in the submucosa, muscular and serosa. TNBS group presented clinical symptoms/signs and histopathological features compatible with a correct induction of UC. The peak of manifestations became maximal at day 4 after induction. This study allows concluding that it’s possible to develop a TNBS induced colitis 4 days after instillation.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica
Resumo:
Dissertação para a obtenção do grau de Mestre em Engenharia Civil
Resumo:
O presente Relatório de Estágio tem como objecto de pesquisa a concepção e monitorização de duas Oficinas de Teatro dirigidas a dois grupos de mulheres constituídos, respectivamente, por estudantes universitárias e desempregadas. O estágio realizou-se entre Novembro/2013 e Junho/2014 na Quarta Parede - Associação de Artes Performativas da Covilhã e inseriu-se nos Empowerment Labs, laboratórios formativos que cruzam artes performativas e ciências sociais na reflexão e intervenção sobre a igualdade de género com foco no desemprego feminino. Este relatório expõe os três momentos do processo do estágio: pesquisa de referenciais teórico-práticos, concepção e monitorização das Oficinas de Teatro e reflexão a partir da prática laboratorial. Na pesquisa de referenciais, essencial para delinear a metodologia operacional e o programa de conteúdos, explorei dimensões como o feminismo e a igualdade de género, e procurei compreender de que forma o empowerment, a pedagogia de Paulo Freire e as metodologias do teatro aplicado serviam os objectivos do meu trabalho. A realização das oficinas foi o momento de experimentar as metodologias e o programa delineado. Tendo a igualdade de género como temática unificadora, o empowerment através da arte como objectivo maior e o teatro aplicado como base metodológica, as oficinas inserem-se nos processos de educação não-formal aplicados ao incremento de recursos intelectuais, emocionais, sociais, expressivos e criativos e, neste caso específico, à ampliação da consciência de género. Neste sentido, as oficinas desenvolveram uma abordagem metodológica processual, participativa e multidisciplinar, orientada para a pesquisa performativa, primeiro de uma dramaturgia individual, depois de uma dramaturgia do colectivo e, por fim, de uma dramaturgia orientada para a igualdade de género. O conceito de “dramaturgia” surge aqui no sentido metodológico do pachwork (trabalho com retalhos) e do sampling (recolha e transformação de materiais), relevante sobretudo na última fase, dedicada à construção colectiva de um exercício performativo apresentado publicamente.