21 resultados para thermal radiation
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Background: Brown adipose tissue (BAT) plays an important role in whole body metabolism and could potentially mediate weight gain and insulin sensitivity. Although some imaging techniques allow BAT detection, there are currently no viable methods for continuous acquisition of BAT energy expenditure. We present a non-invasive technique for long term monitoring of BAT metabolism using microwave radiometry. Methods: A multilayer 3D computational model was created in HFSS™ with 1.5 mm skin, 3-10 mm subcutaneous fat, 200 mm muscle and a BAT region (2-6 cm3) located between fat and muscle. Based on this model, a log-spiral antenna was designed and optimized to maximize reception of thermal emissions from the target (BAT). The power absorption patterns calculated in HFSS™ were combined with simulated thermal distributions computed in COMSOL® to predict radiometric signal measured from an ultra-low-noise microwave radiometer. The power received by the antenna was characterized as a function of different levels of BAT metabolism under cold and noradrenergic stimulation. Results: The optimized frequency band was 1.5-2.2 GHz, with averaged antenna efficiency of 19%. The simulated power received by the radiometric antenna increased 2-9 mdBm (noradrenergic stimulus) and 4-15 mdBm (cold stimulus) corresponding to increased 15-fold BAT metabolism. Conclusions: Results demonstrated the ability to detect thermal radiation from small volumes (2-6 cm3) of BAT located up to 12 mm deep and to monitor small changes (0.5°C) in BAT metabolism. As such, the developed miniature radiometric antenna sensor appears suitable for non-invasive long term monitoring of BAT metabolism.
Resumo:
The big proliferation of mobile communication systems has caused an increased concern about the interaction between the human body and the antennas of mobile handsets. In order to study the problem, a multiband antenna was designed, fabricated and measured to operate over two frequency sub bands 900 and 1800 MHz. After that, we simulated the same antenna, but now, in the presence of a human head model to analyze the head's influence. First, the influence of the human head on the radiation efficiency of the antenna has been investigated as a function of the distance between the head and the antenna and with the inclination of the antenna. Furthermore, the relative amount of the electromagnetic power absorbed in the head has been obtained.
Resumo:
The big proliferation of mobile communication systems has caused an increased concern about the interaction between the human body and the antennas of mobile handsets. In order to study the problem, a multiband antenna was designed, fabricated and measured to operate over two frequency sub bands 900 and 1800 MHz. After that, we simulated the same antenna, but now, in the presence of a human head model to analyze the head's influence. First, the influence of the human head on the radiation efficiency of the antenna has been investigated as a function of the distance between the head and the antenna and with the inclination of the antenna. Furthermore, the relative amount of the electromagnetic power absorbed in the head has been obtained. In this study the electromagnetic analysis has been performed via FDTD (Finite Difference Time Domain).
Resumo:
O presente documento tem como principal objectivo efectuar o projecto de dimensionamento de um sistema de águas quentes sanitárias para uma escola. Numa primeira fase foi elaborado uma pesquisa sobre o contexto energético, a nível mundial, europeu e nacional, bem como o seu contexto jurídico a nível europeu e nacional, e uma explicação superficial sobre os fundamentos da energia solar, onde se foca a importância da radiação solar e os vários tipos de sistemas solares térmicos, bem como os seus constituintes. Segue-se a abordagem ao caso de estudo onde foram efectuados inicialmente inquéritos como forma de determinar os consumos de água quente utilizada nessa escola. Continuou-se o estudo efectuando-se a variação de duas características do sistema solar: o tamanho dos depósitos e o tipo de colectores solares a aplicar. Após as simulações efectuadas para a determinação das soluções a aplicar ao sistemasolar e apresentadas ao longo do presente documento, foram efectuadas análises económicas como forma de se verificar a viabilidade do sistema a aplicar. Por último foram elaboradas conclusões sobre o sistema a aplicar e apresentados alguns cenários financeiros do mesmo.
Resumo:
Purpose/Objective: The purpose of this work was to determine biologically equivalent alternative regimens for the treatment of prostate cancer using External Beam Radiotherapy (EBRT) and Low Dose-Rate Brachytherapy (LDRBT) with 125I implants and to evaluate the sensitivity of these regimens to different sets of radiobiological parameters of the Linear-Quadratic (LQ) model.
Resumo:
The increasing use of ionizing radiation for medical purposes emphasizes the concern about safety and justification of using ionizing radiation. This is linked with the use of new and high-dose X-ray technology (particularly CT). According to the UNSCEAR 2010 Report the total number of diagnostic medical examinations (both medical and dental) is estimated to have risen from 2.4 billion (period 1991–1996) to 3.6 billion (period 1997– 2008) - a marked increase in collective doses. An appropriate use of technology aiming diagnostic or therapy and respecting the ALARA principle is a mandatory requisite to safely perform any radiological procedure. Radiation protection is thus, a concern of all specialists in the radiology field ( radiologists, radiographers, medical physicists, among other professional groups). The importance of education and training of these professionals in reducing patients’ doses while maintaining the desired level of quality in medical exposures, as well as precise therapeutic treatments is well recognized. Education, training and continuing professional development (CPD) constitute a triad pointing towards the radiographers’ development of competences in the radiation protection field. This presentation excludes the radiographer role and competences in the fields of ultrasonography and MRI.
Resumo:
In this paper, we present the results of mammography quality control tests related to the work with Portuguese mammography equipment, either in conventional or in digital mammography computed radiography, showing the main differences in the tested equipments. Quality control in mammography is a very special area of quality control in radiology, which demands relatively high knowledge on physics. Digital imaging is changing the standards of the radiographic imaging. Regarding mammography, this is yet a controversial issue owing to some limitations of the digital detectors, like the resolution for instance. A complete set of results regarding radiation protection of the patients submitted to mammography diagnosis is presented. A discussion of the quality image parameters and its interpretation in conventional and digital mammography is presented. In conclusion, we present a sample of results that can be considered as characteristics of mammography equipment in Portugal.
Resumo:
This work aims at investigating the impact of treating breast cancer using different radiation therapy (RT) techniques – forwardly-planned intensity-modulated, f-IMRT, inversely-planned IMRT and dynamic conformal arc (DCART) RT – and their effects on the whole-breast irradiation and in the undesirable irradiation of the surrounding healthy tissues. Two algorithms of iPlan BrainLAB treatment planning system were compared: Pencil Beam Convolution (PBC) and commercial Monte Carlo (iMC). Seven left-sided breast patients submitted to breast-conserving surgery were enrolled in the study. For each patient, four RT techniques – f-IMRT, IMRT using 2-fields and 5-fields (IMRT2 and IMRT5, respectively) and DCART – were applied. The dose distributions in the planned target volume (PTV) and the dose to the organs at risk (OAR) were compared analyzing dose–volume histograms; further statistical analysis was performed using IBM SPSS v20 software. For PBC, all techniques provided adequate coverage of the PTV. However, statistically significant dose differences were observed between the techniques, in the PTV, OAR and also in the pattern of dose distribution spreading into normal tissues. IMRT5 and DCART spread low doses into greater volumes of normal tissue, right breast, right lung and heart than tangential techniques. However, IMRT5 plans improved distributions for the PTV, exhibiting better conformity and homogeneity in target and reduced high dose percentages in ipsilateral OAR. DCART did not present advantages over any of the techniques investigated. Differences were also found comparing the calculation algorithms: PBC estimated higher doses for the PTV, ipsilateral lung and heart than the iMC algorithm predicted.
Resumo:
Aim - A quantative primary study to determine whether increasing source to image distance (SID), with and without the use of automatic exposure control (AEC) for antero-posterior (AP) pelvis imaging, reduces dose whilst still producing an image of diagnostic quality. Methods - Using a computed radiography (CR) system, an anthropomorphic pelvic phantom was positioned for an AP examination using the table bucky. SID was initially set at 110 cm, with tube potential set at a constant 75 kVp, with two outer chambers selected and a fine focal spot of 0.6 mm. SID was then varied from 90 cm to 140 cm with two exposures made at each 5 cm interval, one using the AEC and another with a constant 16 mAs derived from the initial exposure. Effective dose (E) and entrance surface dose (ESD) were calculated for each acquisition. Seven experienced observers blindly graded image quality using a 5-point Likert scale and 2 Alternative Forced Choice software. Signal-to-Noise Ratio (SNR) was calculated for comparison. For each acquisition, femoral head diameter was also measured for magnification indication. Results - Results demonstrated that when increasing SID from 110 cm to 140 cm, both E and ESD reduced by 3.7% and 17.3% respectively when using AEC and 50.13% and 41.79% respectively, when the constant mAs was used. No significant statistical (T-test) difference (p = 0.967) between image quality was detected when increasing SID, with an intra-observer correlation of 0.77 (95% confidence level). SNR reduced slightly for both AEC (38%) and no AEC (36%) with increasing SID. Conclusion - For CR, increasing SID significantly reduces both E and ESD for AP pelvis imaging without adversely affecting image quality.
Resumo:
Conferência: 2nd Experiment at International Conference - 18-20 September 2013
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica
Resumo:
The consumption of natural products has become a public health problem, since these medicinal teas are prepared using natural plants without an effective hygienic and sanitary control. The aim of this study was to assess the effects of gamma radiation, on the microbial burden of two medicinal plants: Melissa officinalis and Lippia citriodora. Dried samples of the two plants were irradiated at a Co-60 experimental equipment. The applied gamma radiation doses were 1, 3, and 5 kGy at a dose rate of 1.34 kGy/h. Non-irradiated samples followed all the experiments. Bacterial and fungal counts were assessed before and after irradiation by membrane filtration method. Challenging tests with Escherichia coli were performed in order to evaluate the disinfection efficiency of gamma radiation treatment. Characterization of M. officinalis and L. citriadora microbiota indicated an average bioburden value of 102CFU/g. The inactivation studies of the bacterial mesophilic population of both dried plants pointed out to a one log reduction of microbial load after irradiation at 5 kGy. Regarding the fungal population, the initial load of 30 CFU/g was only reduced by 0.5 log by an irradiation dose of 5 kGy. The dynamics with radiation doses of plants microbial population’s phenotypes indicated the prevalence of gram-positive rods for M. officinalis before and after irradiation, and the increase of the frequency of gram-negative rods with irradiation for L. citriadora. Among fungal population of both plants, Mucor, Neoscytalidium, Aspergillus and Alternaria were the most isolated genera. The results obtained in the challenging tests with E. coli on plants pointed out to an inactivation efficiency of 99.5% and 99.9% to a dose of 2 kGy, for M.officinalis and L. citriadora, respectively. The gamma radiation treatment can be a significant tool for the microbial control in medicinal plants.
Resumo:
This paper presents a distributed predictive control methodology for indoor thermal comfort that optimizes the consumption of a limited shared energy resource using an integrated demand-side management approach that involves a power price auction and an appliance loads allocation scheme. The control objective for each subsystem (house or building) aims to minimize the energy cost while maintaining the indoor temperature inside comfort limits. In a distributed coordinated multi-agent ecosystem, each house or building control agent achieves its objectives while sharing, among them, the available energy through the introduction of particular coupling constraints in their underlying optimization problem. Coordination is maintained by a daily green energy auction bring in a demand-side management approach. Also the implemented distributed MPC algorithm is described and validated with simulation studies.
Resumo:
Medical imaging is a powerful diagnostic tool. Consequently, the number of medical images taken has increased vastly over the past few decades. The most common medical imaging techniques use X-radiation as the primary investigative tool. The main limitation of using X-radiation is associated with the risk of developing cancers. Alongside this, technology has advanced and more centres now use CT scanners; these can incur significant radiation burdens compared with traditional X-ray imaging systems. The net effect is that the population radiation burden is rising steadily. Risk arising from X-radiation for diagnostic medical purposes needs minimising and one way to achieve this is through reducing radiation dose whilst optimising image quality. All ages are affected by risk from X-radiation however the increasing population age highlights the elderly as a new group that may require consideration. Of greatest concern are paediatric patients: firstly they are more sensitive to radiation; secondly their younger age means that the potential detriment to this group is greater. Containment of radiation exposure falls to a number of professionals within medical fields, from those who request imaging to those who produce the image. These staff are supported in their radiation protection role by engineers, physicists and technicians. It is important to realise that radiation protection is currently a major European focus of interest and minimum competence levels in radiation protection for radiographers have been defined through the integrated activities of the EU consortium called MEDRAPET. The outcomes of this project have been used by the European Federation of Radiographer Societies to describe the European Qualifications Framework levels for radiographers in radiation protection. Though variations exist between European countries radiographers and nuclear medicine technologists are normally the professional groups who are responsible for exposing screening populations and patients to X-radiation. As part of their training they learn fundamental principles of radiation protection and theoretical and practical approaches to dose minimisation. However dose minimisation is complex – it is not simply about reducing X-radiation without taking into account major contextual factors. These factors relate to the real world of clinical imaging and include the need to measure clinical image quality and lesion visibility when applying X-radiation dose reduction strategies. This requires the use of validated psychological and physics techniques to measure clinical image quality and lesion perceptibility.
Resumo:
Present study develops and implements a specific methodology for the assessment of health risks derived from occupational exposure of workers to ionizing radiation in the fertilizer manufacturing industry. Negative effects on the health of exposed workers are identified, according to the types and levels of exposure to which they are subject, namely an increase of the risk of cancer even with long term exposure to low level radiation. Ionizing radiation types, methods and measuring equipment are characterized. The methodology developed in a case study of a phosphate fertilizer industry is applied, assessing occupational exposure to ionizing radiation caused by external radiation and the inhalation of radioactive gases and dust.