3 resultados para stereopsis

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Stereopsis is the perception of depth based on retinal disparity. Global stereopsis depends on the process of random dot stimuli and local stereopsis depends on contour perception. The aim of this study was to correlate 3 stereopsis tests: TNO®, StereoTA B®, and Fly Stereo Acuity Test® and to study the sensitivity and correlation between them, using TNO® as the gold standard. Other variables as near convergence point, vergences, symptoms and optical correction were correlated with the 3 tests. Materials and Methods: Forty-nine students from Escola Superior de Tecnologia da Saúde de Lisboa (ESTeSL), aged 18-26 years old were included. Results: The stereopsis mean (standard-deviation-SD) values in each test were: TNO® = 87.04” ±84.09”; FlyTest® = 38.18” ±34.59”; StereoTA B® = 124.89’’ ±137.38’’. About the coefficient of determination: TNO® and StereoTA B® with R2 = 0.6 e TNO® and FlyTest® with R2 =0.2. Pearson correlation coefficient shows a positive correlation between TNO® and StereoTA B® (r = 0.784 with α = 0.01). Phi coefficient shows a strong and positive association between TNO® and StereoTA B® (Φ = 0.848 with α = 0.01). In the ROC Curve, the StereoTA B® has an area under the curve bigger than the FlyTest® with a sensivity of 92.3% for 94.4% of specificity, so it means that the test is sensitive with a good discriminative power. Conclusion: We conclude that the use of Stereopsis tests to study global Stereopsis are an asset for clinical use. This type of test is more sensitive, revealing changes in Stereopsis when it is actually changed, unlike the test Stereopsis, which often indicates normal Stereopsis, camouflaging a Stereopsis change. We noted also that the StereoTA B ® is very sensitive and despite being a digital application, possessed good correlation with the TNO®.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aims of this study were to compare angle of deviation, fusional vergence measurements and fusion reserve ratio between esophoria and exophoria. Methods: A cross-sectional study was performed in children with best-corrected visual acuity of 0.0 LogMAR in either eye, compensated heterophoria within 10 prism dioptres (PD), full ocular rotations, presence of fusional vergence and stereopsis (60 seconds of arc or better). Fusional amplitudes were compared between angle of deviation (2, 4, 6, 8 and 10 PD) in esophoria and exophoria. The fusion reserve ratio was calculated (to assess the effect of the underlying angle of deviation) as fusional convergence divided by prism alternating cover test measurements. Results: Two-hundred and eleven children (7.65±1.16 years) were recruited to this study. Exophoria was most common for near (n=181; 85.8%) and distance (n=20; 9.5%). Esophoria was present in 22 children for near (10.4%) and in 1 child for distance (0.5%). No significant differences were found between fusional amplitudes and angle of deviation for near (p>0.05). Children with exophoria of 10PD had a slight, but not, significant (p=0.264) increase in fusional convergence from 2PD (19.95±5.09) to 10PD (26.67±5.77). In esophoric children the variation of fusional convergence was smaller from 2P (25.00±0.00) to 10PD (22.50±3.54) and non significant (p=0.185). The fusion reserve ratio was significantly smaller in children with higher deviations (i.e. 10PD) for both esophoria (p=0.003) and exophoria (p>0.001). The fusion reserve ratio ranged between 12.50 (2PD) and 2.25±0.35 (10PD) for esophoria and between 9.98±2.55 (2PD) and 2.67±0.58 (10PD) for exophoria. Conclusions: Angle of deviation is not an efficient measure to predict fusional amplitudes. The fusion reserve ratio appears to be a better measurement to assess the effect of the underlying angle of deviation on fusional convergence. More studies are necessary to understand better the relationship between fusion amplitudes and angle of deviation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Estereopsia define-se como a perceção de profundidade baseada na disparidade retiniana. A estereopsia global depende do processamento de estímulos de pontos aleatórios e a estereopsia local depende da perceção de contornos. O objetivo deste estudo é correlacionar três testes de estereopsia: TNO®, StereoTAB® e Fly Stereo Acuity Test® e verificar a sensibilidade e correlação entre eles, tendo o TNO® como gold standard. Incluíram-se 49 estudantes da Escola Superior de Tecnologia da Saúde de Lisboa (ESTeSL) entre os 18 e 26 anos. As variáveis ponto próximo de convergência (ppc), vergências, sintomatologia e correção ótica foram correlacionadas com os três testes. Os valores médios (desvios-padrão) de estereopsia foram: TNO® = 87,04’’ ±84,09’’; FlyTest® = 38,18’’ ±34,59’’; StereoTAB® = 124,89’’ ±137,38’’. Coeficiente de determinação: TNO® e StereoTAB® com R2=0,6 e TNO® e FlyTest® com R2=0,2. O coeficiente de correlação de Pearson mostra uma correlação positiva de entre o TNO® e o StereoTAB® (r=0,784 com α=0,01). O coeficiente de associação de Phi mostrou uma relação positiva forte entre o TNO® e StereoTAB® (Φ=0,848 com α=0,01). Na curva ROC, o StereoTAB® possui uma área sob a curva maior que o FlyTest®, apresentando valor de sensibilidade de 92,3% para uma especificidade de 94,4%, tornando-o num teste sensível e com bom poder discriminativo.