Resumo:
Low noise surfaces have been increasingly considered as a viable and cost-effective alternative to acoustical barriers. However, road planners and administrators frequently lack information on the correlation between the type of road surface and the resulting noise emission profile. To address this problem, a method to identify and classify different types of road pavements was developed, whereby near field road noise is analyzed using statistical learning methods. The vehicle rolling sound signal near the tires and close to the road surface was acquired by two microphones in a special arrangement which implements the Close-Proximity method. A set of features, characterizing the properties of the road pavement, was extracted from the corresponding sound profiles. A feature selection method was used to automatically select those that are most relevant in predicting the type of pavement, while reducing the computational cost. A set of different types of road pavement segments were tested and the performance of the classifier was evaluated. Results of pavement classification performed during a road journey are presented on a map, together with geographical data. This procedure leads to a considerable improvement in the quality of road pavement noise data, thereby increasing the accuracy of road traffic noise prediction models.
Resumo:
In this paper we present results on the optimization of multilayered a-SiC:H heterostructures that can be used as optical transducers for fluorescent proteins detection using the Fluorescence Resonance Energy Transfer approach. Double structures composed by pin based aSiC:H cells are analyzed. The color discrimination is achieved by ac photocurrent measurement under different externally applied bias. Experimental data on spectral response analysis, current-voltage characteristics and color and transmission rate discrimination are reported. An electrical model, supported by a numerical simulation gives insight into the device operation. Results show that the optimized a-SiC:H heterostructures act as voltage controlled optical filters in the visible spectrum. When the applied voltages are chosen appropriately those optical transducers can detect not only the selective excitation of specimen fluorophores, but also the subsequent weak acceptor fluorescent channel emission.
Resumo:
In this paper we present an amorphous silicon device that can be used in two operation modes to measure the concentration of ions in solution. While crystalline devices present a higher sensitivity, their amorphous counterpart present a much lower fabrication cost, thus enabling the production of cheap disposable sensors for use, for example, in the food industry. The devices were fabricated on glass substrates by the PECVD technique in the top gate configuration, where the metallic gate is replaced by an electrolytic solution with an immersed Ag/AgCl reference electrode. Silicon nitride is used as gate dielectric enhancing the sensitivity and passivation layer used to avoid leakage and electrochemical reactions. In this article we report on the semiconductor unit, showing that the device can be operated in a light-assisted mode, where changes in the pH produce changes on the measured ac photocurrent. In alternative the device can be operated as a conventional ion selective field effect device where changes in the pH induce changes in the transistor's threshold voltage.
Resumo:
Wyner - Ziv (WZ) video coding is a particular case of distributed video coding (DVC), the recent video coding paradigm based on the Slepian - Wolf and Wyner - Ziv theorems which exploits the source temporal correlation at the decoder and not at the encoder as in predictive video coding. Although some progress has been made in the last years, WZ video coding is still far from the compression performance of predictive video coding, especially for high and complex motion contents. The WZ video codec adopted in this study is based on a transform domain WZ video coding architecture with feedback channel-driven rate control, whose modules have been improved with some recent coding tools. This study proposes a novel motion learning approach to successively improve the rate-distortion (RD) performance of the WZ video codec as the decoding proceeds, making use of the already decoded transform bands to improve the decoding process for the remaining transform bands. The results obtained reveal gains up to 2.3 dB in the RD curves against the performance for the same codec without the proposed motion learning approach for high motion sequences and long group of pictures (GOP) sizes.
Resumo:
Com a evolução tecnológica, a informática assumiu um papel fulcral na nossa vida actual tanto numa vertente doméstica como para as mais variadíssimas organizações. As redes IP estão disseminadas por todo o lado, escritórios, habitações, estabelecimentos de ensino, espaços comerciais, com as mais diversas topologias e dimensões, que como qualquer recurso devem ser bem geridas. O presente projecto insere-se neste contexto, pretendendo criar um sistema para dar apoio no controlo e gestão de endereçamento IP dados por um servidor DHCP. A problemática central que este projecto pretende tratar é a detecção da configuração forçada de endereços IP por parte dos utilizadores, notificando tais situações aos administradores de rede. O sistema é constituído por vários componentes como Linux, MySQL, ISC DHCP, SNMP, PHP, APACHE e irá interagir com equipamentos de rede que possuam tabelas de endereços para que a informação, nestas encontradas, seja comparada com a informação dos endereços fornecidos pelo servidor DHCP. O sistema dá suporte a uma página web que pretende auxiliar algumas configurações e fornecer informações estatísticas sobre a rede.
Resumo:
A presente dissertação pretende conceber e implementar um sistema de controlo tolerante a falhas, no canal experimental de rega da Universidade de Évora, utilizando um modelo implementado em MATLAB/SIMULINK®. Como forma de responder a este desafio, analisaram-se várias técnicas de diagnóstico de falhas, tendo-se optado por técnicas baseadas em redes neuronais para o desenvolvimento de um sistema de detecção e isolamento de falhas no canal de rega, sem ter em conta o tipo de sistema de controlo utilizado. As redes neuronais foram, assim, os processadores não lineares utilizados e mais aconselhados em situações onde exista uma abundância de dados do processo, porque aprendem por exemplos e são suportadas por teorias estatísticas e de optimização, focando não somente o processamento de sinais, como também expandindo os horizontes desse processamento. A ênfase dos modelos das redes neuronais está na sua dinâmica, na sua estabilidade e no seu comportamento. Portanto, o trabalho de investigação do qual resultou esta Dissertação teve como principais objectivos o desenvolvimento de modelos de redes neuronais que representassem da melhor forma a dinâmica do canal de rega, de modo a obter um sistema de detecção de falhas que faça uma comparação entre os valores obtidos nos modelos e no processo. Com esta diferença de valores, da qual resultará um resíduo, é possível desenvolver tanto o sistema de detecção como de isolamento de falhas baseados nas redes neuronais, possibilitando assim o desenvolvimento dum sistema de controlo tolerante a falhas, que engloba os módulos de detecção, de isolamento/diagnóstico e de reconfiguração do canal de rega. Em síntese, na Dissertação realizada desenvolveu-se um sistema que permite reconfigurar o processo em caso de ocorrência de falhas, melhorando significativamente o desempenho do canal de rega.
Resumo:
The devastating impact of the Sumatra tsunami of 26 December 2004, raised the question for scientists of how to forecast a tsunami threat. In 2005, the IOC-UNESCO XXIII assembly decided to implement a global tsunami warning system to cover the regions that were not yet protected, namely the Indian Ocean, the Caribbean and the North East Atlantic, the Mediterranean and connected seas (the NEAM region). Within NEAM, the Gulf of Cadiz is the more sensitive area, with an important record of devastating historical events. The objective of this paper is to present a preliminary design for a reliable tsunami detection network for the Gulf of Cadiz, based on a network of sea-level observatories. The tsunamigenic potential of this region has been revised in order to define the active tectonic structures. Tsunami hydrodynamic modeling and GIS technology have been used to identify the appropriate locations for the minimum number of sea-level stations. Results show that 3 tsunameters are required as the minimum number of stations necessary to assure an acceptable protection to the large coastal population in the Gulf of Cadiz. In addition, 29 tide gauge stations could be necessary to fully assess the effects of a tsunami along the affected coasts of Portugal, Spain and Morocco.
Resumo:
An optically addressed read-write sensor based on two stacked p-i-n heterojunctions is analyzed. The device is a two terminal image sensing structure. The charge packets are injected optically into the p-i-n writer and confined at the illuminated regions changing locally the electrical field profile across the p-i-n reader. An optical scanner is used for charge readout. The design allows a continuous readout without the need for pixel-level patterning. The role of light pattern and scanner wavelengths on the readout parameters is analyzed. The optical-to-electrical transfer characteristics show high quantum efficiency, broad spectral response, and reciprocity between light and image signal. A numerical simulation supports the imaging process. A black and white image is acquired with a resolution around 20 mum showing the potentiality of these devices for imaging applications.
Resumo:
ZnO:Al/p (SiC:H)/i (Si:H)/n (SiC:H) large area image and colour sensor are analysed. Carrier transport and collection efficiency are investigated from dark and illuminated current-voltage (I-V) dependence and spectral response measurements under different optical and electrical bias conditions. Results show that the carrier collection depends on the optical bias and on the applied voltage. By changing the electrical bias around the open circuit voltage it is possible to filter the absorption at a given wavelength and so to tune the spectral sensitivity of the device. Transport and optical modelling give insight into the internal physical process and explain the bias control of the spectral response and the image and colour sensing properties of the devices.
Resumo:
Structures experience various types of loads along their lifetime, which can be either static or dynamic and may be associated to phenomena of corrosion and chemical attack, among others. As a consequence, different types of structural damage can be produced; the deteriorated structure may have its capacity affected, leading to excessive vibration problems or even possible failure. It is very important to develop methods that are able to simultaneously detect the existence of damage and to quantify its extent. In this paper the authors propose a method to detect and quantify structural damage, using response transmissibilities measured along the structure. Some numerical simulations are presented and a comparison is made with results using frequency response functions. Experimental tests are also undertaken to validate the proposed technique. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Optical colour sensors based on multilayered a-SiC:H heterostructures can act as voltage controlled optical filters in the visible range. In this article we investigate the application of these structures for Fluorescence Resonance Energy Transfer (FRET) detection, The characteristics of a-SiC:H multilayered structure are studied both theoretically and experimentally in several wavelengths corresponding to different fluorophores. The tunable optical p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructures were produced by PECVD and tested for a proper fine tuning in the violet, cyan and yellow wavelengths. The devices were characterized through transmittance and spectral response measurements, under different electrical bias and frequencies. Violet, cyan and yellow signals were applied in simultaneous and results have shown that they can be recovered under suitable applied bias. A theoretical analysis supported by numerical simulation is presented.
Resumo:
In order to evaluate the capacity of laser scanning cytometry (LSC) to detect acid-fast bacilli directly on clinical samples, a comparison between Kinyoun-stained smears analyzed under light microscopy and propidium iodide-auramine-stained smears analyzed by LSC was performed. The results were compared with those for culture on BACTEC MGIT 960. LSC is a new, reliable methodology to detect Mycobacteria.
Resumo:
RESUMO: Objetivos – Determinar a sensibilidade e especificidade das ponderações Difusão (DWI) e T2 Fluid-Attenuated Inversion Recovery (FLAIR) na avaliação de lesões da substância branca (SB) e verificar em que medida se complementam, por forma a criar um conjunto de boas práticas na RM cranioencefálica de rotina. Metodologia – Recorrendo-se a uma metodologia quantitativa, efetuou-se uma análise retrospetiva da qual foram selecionados 30 pacientes, 10 sem patologia e 20 com patologia (2 com EM, 7 com Leucoencefalopatia, 6 com doença microangiopática e 5 com patologia da substância branca indefinida). Obteve-se uma amostra de 60 imagens, nomeadamente: 30 imagens ponderadas em DWI e 30 em T2 FLAIR. Recorrendo ao programa Viewdex®, três observadores avaliaram um conjunto de imagens segundo sete critérios: visibilidade, deteção, homogeneidade, localização, margens e dimensões da lesão e capacidade de diagnóstico. Com os resultados obtidos recorreu-se ao cálculo de sensibilidade e especificidade pelas Curvas ROC, bem como à análise estatística, nomeadamente, Teste-T, Índice de Concordância Kappa e coeficiente de correlação de Pearson entre as variáveis em estudo. Resultados – Os resultados de sensibilidade e de especificidade obtidos para a ponderação T2 FLAIR foram superiores (0,915 e 0,038, respetivamente) aos da ponderação DWI (0,08 e 0,100, respetivamente). Não se verificaram variâncias populacionais significativas. Obteve-se uma elevada correlação linear entre as variáveis com um valor r situado entre 0,8 e 0,99. Verificou-se também uma variabilidade considerável entre os observadores. Conclusões – Dados os baixos valores de sensibilidade e especificidade obtidos para a DWI, sugere-se que esta deva ser incluída no protocolo de rotina de crânio como auxiliar no diagnóstico diferencial com outras patologias.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Área de especialização: Imagem Digital por Radiação X.
Resumo:
The transducer consists of a semiconductor device based on two stacked -i-n heterostructures that were designed to detect the emissions of the fluorescence resonance energy transfer between fluorophores in the cyan (470 nm) and yellow (588 nm) range of the spectrum. This research represents a preliminary study on the use of such wavelength-sensitive devices as photodetectors for this kind of application. The device was characterized through optoelectronic measurements concerning spectral response measurements under different electrical and optical biasing conditions. To simulate the fluorescence resonance energy transfer (FRET) pairs, a chromatic time-dependent combination of cyan and yellow wavelengths was applied to the device. The generated photocurrent was measured under reverse and forward bias to read out the output photocurrent signal. A different wavelength-biasing light was also superimposed. Results show that under reverse bias, the photocurrent signal presents four separate levels, each one assigned to the different wavelength combinations of the FRET pairs. If a blue background is superimposed, the yellow channel is enhanced and the cyan suppressed, while under red irradiation, the opposite behavior occurs. So, under suitable biasing light, the transducer is able to detect separately the cyan and yellow fluorescence pairs. An electrical model, supported by a numerical simulation, supports the transduction mechanism of the device.