20 resultados para specimen manipulation

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Invasive stages of apicomplexan parasites require a host cell to survive, proliferate and advance to the next life cycle stage. Once invasion is achieved, apicomplexans interact closely with the host cell cytoskeleton, but in many cases the different species have evolved distinct mechanisms and pathways to modulate the structural organization of cytoskeletal filaments. The host cell cytoskeleton is a complex network, largely, but not exclusively, composed of microtubules, actin microfilaments and intermediate filaments, all of which are modulated by associated proteins, and it is involved in diverse functions including maintenance of cell morphology and mechanical support, migration, signal transduction, nutrient uptake, membrane and organelle trafficking and cell division. The ability of apicomplexans to modulate the cytoskeleton to their own advantage is clearly beneficial. We here review different aspects of the interactions of apicomplexans with the three main cytoskeletal filament types, provide information on the currently known parasite effector proteins and respective host cell targets involved, and how these interactions modulate the host cell physiology. Some of these findings could provide novel targets that could be exploited for the development of preventive and/or therapeutic strategies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we present results on the optimization of multilayered a-SiC:H heterostructures that can be used as optical transducers for fluorescent proteins detection using the Fluorescence Resonance Energy Transfer approach. Double structures composed by pin based aSiC:H cells are analyzed. The color discrimination is achieved by ac photocurrent measurement under different externally applied bias. Experimental data on spectral response analysis, current-voltage characteristics and color and transmission rate discrimination are reported. An electrical model, supported by a numerical simulation gives insight into the device operation. Results show that the optimized a-SiC:H heterostructures act as voltage controlled optical filters in the visible spectrum. When the applied voltages are chosen appropriately those optical transducers can detect not only the selective excitation of specimen fluorophores, but also the subsequent weak acceptor fluorescent channel emission.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the major problems that prevents the spread of elections with the possibility of remote voting over electronic networks, also called Internet Voting, is the use of unreliable client platforms, such as the voter's computer and the Internet infrastructure connecting it to the election server. A computer connected to the Internet is exposed to viruses, worms, Trojans, spyware, malware and other threats that can compromise the election's integrity. For instance, it is possible to write a virus that changes the voter's vote to a predetermined vote on election's day. Another possible attack is the creation of a fake election web site where the voter uses a malicious vote program on the web site that manipulates the voter's vote (phishing/pharming attack). Such attacks may not disturb the election protocol, therefore can remain undetected in the eyes of the election auditors. We propose the use of Code Voting to overcome insecurity of the client platform. Code Voting consists in creating a secure communication channel to communicate the voter's vote between the voter and a trusted component attached to the voter's computer. Consequently, no one controlling the voter's computer can change the his/her's vote. The trusted component can then process the vote according to a cryptographic voting protocol to enable cryptographic verification at the server's side.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O âmbito desta dissertação centra-se na temática de estudos de durabilidade do betão auto-compactavel (BAC), cujo cálculo dos constituintes foi feito pelo método de Nepomuceno. Sobre amostras de 40, 55 e 70 MPa, produzidas segundo o método atrás identificado, foram feitos estudos químicos e morfológicos, de propriedades de transporte de mecanismos de degradação e de propriedades indirectas. Os três provetes em estudo de 40, 55 e 70 MPa, apresentam características satisfatórias a nível da microestrutura, propriedades de transporte, carbonatação, penetração de cloretos e análise de ultra-sons. Numa análise comparativa entre as três resistências mecânicas em estudo, verifica-se que as propriedades de durabilidade vão melhorando a medida que a resistência mecânica também aumenta, ou seja, os provete com 70 MPa apresentam as melhores características a nível de durabilidade e os de 40 as piores; os de 55 apresentam propriedades intermédias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article aims to discuss the role humour plays in politics, particularly in a media environment overflowing with user-generated video. We start with a genealogy of political satire, from classical to Internet times, followed by a general description of “the Downfall meme,” a series of videos on YouTube featuring footage from the film Der Untergang and nonsensical subtitles. Amid video-games, celebrities, and the Internet itself, politicians and politics are the target of such twenty-first century caricatures. By analysing these videos we hope to elucidate how the manipulation of images is embedded in everyday practices and may be of political consequence, namely by deflating politicians' constructed media image. The realm of image, at the centre of the Internet's technological culture, is connected with decisive aspects of today's social structure of knowledge and play. It is timely to understand which part of “playing” is in fact an expressive practice with political significance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Once in a digital form, a radiographic image may be processed in several ways in order to turn the visualization an act of improved diagnostic value. Practitioners should be aware that, depending on each clinical context, digital image processing techniques are available to help to unveil visual information that is, in fact, carried by the bare digital radiograph and may be otherwise neglected. The range of visual enhancement procedures includes simple techniques that deal with the usual brightness and contrast manipulation up to much more elaborate multi-scale processing that provides customized control over the emphasis given to the relevant finer anatomical details. This chapter is intended to give the reader a practical understanding of image enhancement techniques that might be helpful to improve the visual quality of the digital radiographs and thus to contribute to a more reliable and assertive reporting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada à Escola Superior de Comunicação Social como parte dos requisitos para obtenção de grau de mestre em Audiovisual e Multimédia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tunable wavelength division multiplexing converters based on amorphous SiC multilayer photonic active filters are analyzed. The configuration includes two stacked p-i-n structures (p(a-SiC:H)-i'(a-SiC:H)-n(a-SiC:H)-p(a-SiC:H)-i(a-Si:H)-n(a-Si:H)) sandwiched between two transparent contacts. The manipulation of the magnitude is achieved through appropriated front and back backgrounds. Transfer function characteristics are studied both theoretically and experimentally. An algorithm to decode the multiplex signal is established. An optoelectronic model supports the optoelectronic logic architecture. Results show that the light-activated device combines the demultiplexing operation with the simultaneous photodetection and self-amplification of an optical signal. The output waveform presents a nonlinear amplitude-dependent response to the wavelengths of the input channels. Depending on the wavelength of the external background and irradiation side, it acts either as a short- or a long-pass band filter or as a band-stop filter. A two-stage active circuit is presented and gives insight into the physics of the device.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Results of research work developed in anatomy and pathology laboratories have indicated that “macroscopic examination” is the task involving the highest exposure to formaldehyde. This is probably because precision and very good visibility are needed and, therefore, pathologists must lean over the specimen with consequent increase of proximity. With this research we aimed to know formaldehyde exposure in case of animal’s macroscopic examination. Three macroscopic examinations were considered and exposure assessment performed with photo ionization detection (PID) direct-reading equipment (with an 11.7 eV lamp) designated by First-Check, from Ion Science. Higher values of formaldehyde concentration (ceiling values) were register in each exam.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The basic function of the human hand is the manipulation and grasping of various objects in all daily activities, including work activities. This is greatly influenced by strength and manual dexterity. However age, gender and other contexts such as work or leisure activities could influence strength. Handgrip strength, a measure of maximum voluntary force of the hand, has proved to be reliable and valid as an objective parameter to evaluate the functional integrity of the hand as part of the musculoskeletal system. It correlates highly with strength in other muscular groups and is therefore considered as a good indicator of overall muscular strength and functional stress and could be used as a predictor of physical disability. Handgrip strength assessment is simple and reliable and used commonly by several investigators and health professionals, in different contexts (medical, nutritional, rehabilitation, professional settings, engineering, etc.) and with different purposes (research, diagnostic, assessment, etc.). In clinical and rehabilitation settings is of vital importance in the determination of effectiveness of several interventions and for monitoring evolution of diseases. Various ways (methods, techniques and equipments) of collecting information on grip strength have been reported. This chapter will review basic concepts on handgrip function, methodologies of assessment, contexts of application and correlates, such as physical activity, health or nutritional status. Several populations and reference values as also the relationships between handgrip and clinical status, aging, risk of disability and diseases, will be discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nanotechnology is an important emerging industry with a projected annual market of around one trillion dollars by 2015. It involves the control of atoms and molecules to create new materials with a variety of useful functions. Although there are advantages on the utilization of these nano-scale materials, questions related with its impact over the environment and human health must be addressed too, so that potential risks can be limited at early stages of development. At this time, occupational health risks associated with manufacturing and use of nanoparticles are not yet clearly understood. However, workers may be exposed to nanoparticles through inhalation at levels that can greatly exceed ambient concentrations. Current workplace exposure limits are based on particle mass, but this criteria could not be adequate in this case as nanoparticles are characterized by very large surface area, which has been pointed out as the distinctive characteristic that could even turn out an inert substance into another substance exhibiting very different interactions with biological fluids and cells. Therefore, it seems that, when assessing human exposure based on the mass concentration of particles, which is widely adopted for particles over 1 μm, would not work in this particular case. In fact, nanoparticles have far more surface area for the equivalent mass of larger particles, which increases the chance they may react with body tissues. Thus, it has been claimed that surface area should be used for nanoparticle exposure and dosing. As a result, assessing exposure based on the measurement of particle surface area is of increasing interest. It is well known that lung deposition is the most efficient way for airborne particles to enter the body and cause adverse health effects. If nanoparticles can deposit in the lung and remain there, have an active surface chemistry and interact with the body, then, there is potential for exposure. It was showed that surface area plays an important role in the toxicity of nanoparticles and this is the metric that best correlates with particle-induced adverse health effects. The potential for adverse health effects seems to be directly proportional to particle surface area. The objective of the study is to identify and validate methods and tools for measuring nanoparticles during production, manipulation and use of nanomaterials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

No presente artigo é relatado um caso de uma paciente de 42 anos, diagnosticada em 2011 com Adenocarcinoma in situ e displasia grave do epitélio de revestimento pavimentoso, que foi tratada por traquelectomia. Em Novembro de 2013, a paciente realizou uma citologia da cúpula vaginal, onde se observaram achados citológicos compatíveis com lesão intraepitelial de baixo grau mas também a presença de células que favorecem o diagnóstico de lesão intraepitelial de alto grau. Não sendo possível classificar a lesão intraepitelial como sendo claramente baixo ou alto grau, atribuiu-se a interpretação de lesão intraepitelial de grau indeterminado. Para confirmação e esclarecimento do diagnóstico foi efetuada biopsia com resultado de displasia grave do epitélio de revestimento pavimentoso vaginal sem evidência de invasão do estroma. Por fim foi indicada a pesquisa e tipificação de vírus do papiloma humano, com resultado positivo para o tipo 16. Diagnósticos citológicos de lesão intraepitelial de grau indeterminado apresentam um follow-up histológico estatisticamente diferente das lesões intraepiteliais de alto e baixo grau, e estão na sua maioria associadas a infeção por vírus do papiloma humano de alto risco. Os achados citológicos do presente estudo apoiam a necessidade de se estabelecer esta lesão como categoria de diagnóstico no Sistema de Bethesda, com um follow-up definido.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to correctly assess the biaxial fatigue material properties one must experimentally test different load conditions and stress levels. With the rise of new in-plane biaxial fatigue testing machines, using smaller and more efficient electrical motors, instead of the conventional hydraulic machines, it is necessary to reduce the specimen size and to ensure that the specimen geometry is appropriated for the load capacity installed. At the present time there are no standard specimen’s geometries and the indications on literature how to design an efficient test specimen are insufficient. The main goal of this paper is to present the methodology on how to obtain an optimal cruciform specimen geometry, with thickness reduction in the gauge area, appropriated for fatigue crack initiation, as a function of the base material sheet thickness used to build the specimen. The geometry is optimized for maximum stress using several parameters, ensuring that in the gauge area the stress is uniform and maximum with two limit phase shift loading conditions. Therefore the fatigue damage will always initiate on the center of the specimen, avoiding failure outside this region. Using the Renard Series of preferred numbers for the base material sheet thickness as a reference, the reaming geometry parameters are optimized using a derivative-free methodology, called direct multi search (DMS) method. The final optimal geometry as a function of the base material sheet thickness is proposed, as a guide line for cruciform specimens design, and as a possible contribution for a future standard on in-plane biaxial fatigue tests. © 2014, Gruppo Italiano Frattura. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Contabilidade