6 resultados para soil moisture sensor interface
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Thesis submitted in the fulfilment of the requirements for the Degree of Master in Electronic and Telecomunications Engineering
Resumo:
The contribution of the evapotranspiration from a certain region to the precipitation over the same area is referred to as water recycling. In this paper, we explore the spatiotemporal links between the recycling mechanism and the Iberian rainfall regime. We use a 9 km resolution Weather Research and Forecasting simulation of 18 years (1990-2007) to compute local and regional recycling ratios over Iberia, at the monthly scale, through both an analytical and a numerical recycling model. In contrast to coastal areas, the interior of Iberia experiences a relative maximum of precipitation in spring, suggesting a prominent role of land-atmosphere interactions on the inland precipitation regime during this period of the year. Local recycling ratios are the highest in spring and early summer, coinciding with those areas where this spring peak of rainfall represents the absolute maximum in the annual cycle. This confirms that recycling processes are crucial to explain the Iberian spring precipitation, particularly over the eastern and northeastern sectors. Average monthly recycling values range from 0.04 in December to 0.14 in June according to the numerical model and from 0.03 in December to 0.07 in May according to the analytical procedure. Our analysis shows that the highest values of recycling are limited by the coexistence of two necessary mechanisms: (1) the availability of sufficient soil moisture and (2) the occurrence of appropriate synoptic configurations favoring the development of convective regimes. The analyzed surplus of rainfall in spring has a critical impact on agriculture over large semiarid regions of the interior of Iberia.
Resumo:
Esta tese tem como principal objectivo a investigação teórica e experimental do desempenho de um sensor polarimétrico baseado num cristal líquido para medição da concentração de glicose. Recentemente uma série de sensores polarimétricos baseados em cristais líquidos foram propostos na literatura e receberam considerável interesse devido as suas características únicas. De facto, em comparação com outros moduladores electro-ópticos, o cristal líquido funciona com tensões mais baixas, tem baixo consumo de energia e maior ângulo de rotação. Além disso, este tipo de polarímetro pode ter pequenas dimensões que é uma característica interessante para dispositivos portáteis e compactos. Existem por outro lado algumas desvantagens, nomeadamente o facto do desempenho do polarímetro ser fortemente dependente do tipo de cristal líquido e da tensão a ele aplicada o que coloca desafios na escolha dos parâmetros óptimos de operação. Esta tese descreve o desenvolvimento do sensor polarimétrico, incluindo a integração dos componentes de óptica e electrónica, os algoritmos de processamento de sinal e um interface gráfico que facilita a programação de diversos parâmetros de operação e a calibração do sensor. Após a optimização dos parâmetros de operação verificou-se que o dispositivo mede a concentração da glicose em amostras com uma concentração de 8 mg/ml, com uma percentagem de erro inferior a 6% e um desvio padrão de 0,008o. Os resultados foram obtidos para uma amostra com percurso óptico de apenas 1 cm.
Resumo:
A visible/near-infrared optical sensor based on an ITO/SiOx/n-Si structure with internal gain is presented. This surface-barrier structure was fabricated by a low-temperature processing technique. The interface properties and carder transport were investigated from dark current-voltage and capacitance-voltage characteristics. Examination of the multiplication properties was performed under different light excitation and reverse bias conditions. The spectral and pulse response characteristics are analysed. The current amplification mechanism is interpreted by the control of electron current by the space charge of photogenerated holes near the SiOx/Si interface. The optical sensor output characteristics and some possible device applications are presented.
Resumo:
We discuss the operation of a new type of optical sensor (MISCam) based on a metal-insulator-semiconductor (MIS) structure. The operation principle relies on light-induced changes of the band bending and barrier height at the interface between semiconductor and insulator. An image is obtained from the quenching of the ac signal in analogy to the principle of the laser-scanned photodiode (LSP). Lateral resolution depends on the semiconductor material chosen. We have characterised the MIS structures by C-V, I-V, and spectral response measurements testing different types of insulators like a-Si3N4, SiO2, and AlN. The presence of slow interface charges allows for image memory. Colour sensors can be realised by controlling sign and magnitude of the electric fields in the base and the interface region.
Resumo:
A presente dissertação tem como finalidade apresentar uma investigação teórica e experimental sobre um sensor polarimétrico, portátil e de baixo custo, baseado num cristal líquido para a medição da concentração de glicose existente numa amostra. Devido ao crescente número de pessoas que sofrem de Diabetes, existe grande interesse em desenvolver sensores portáteis que permitam medir a concentração de glicose de forma rápida, precisa e indolor. Dos vários métodos não invasivos existentes para a medição de concentração de glicose, o método utilizado tem como base a medição da rotação da polarização da luz. Recentemente os sensores polarimétricos baseados em cristais líquidos, têm adquirido grande ênfase devido às suas características únicas que, em comparação com outros moduladores electroópticos, funcionam com tensões mais baixas, apresentam menor consumo energético e maior ângulo de rotação. No entanto também existem diversas desvantagens, nomeadamente a falta de documentação sobre a realização de testes e resultados obtidos em sensores polarimétricos. Têm como desvantagem adicional o facto do comportamento do polarímetro ser fortemente dependente do tipo de cristal líquido e da tensão a este aplicado. A presente dissertação descreve o desenvolvimento de um sensor polarimétrico que inclui a componente óptica, a componente electrónica de detecção e acondicionamento do sinal, a comunicação sem fios com um PC, e, por fim, a componente de análise e interface com o utilizador. Neste sensor polarimétrico poderão ser efectuadas leituras de temperatura das amostras para efeitos de correcção do cálculo da concentração da glicose. O dispositivo permite ainda a gravação dos dados obtidos e identificação dos mesmos. Os resultados obtidos demonstram que o dispositivo é capaz de medir concentrações com 10mg/ml de glicose, com uma percentagem de erro de 15%, para uma amostra com um percurso óptico de apenas 1 cm.