13 resultados para rooms

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction - Some studies point to human activities as one of the responsible for most bacterial concentration. However, there is no information regarding bacteria contamination in hotel room during the cleaning activity. Aim of the study - This study aims to assess and characterize the occupational exposure of bacterial contamination in hotel rooms, more precisely in a room with carpet floor and another room without carpet, during the cheaning activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The majority of studies investigated ambient particles, although in most industrialized countries people spend most of their time indoors and significant emissions of fine and ultrafine particles leading to human exposure are caused by various indoor tasks, including cleaning tasks. Objective: To characterize the occupational exposure to particles during cleaning of hotel's rooms. Methodology: Measurements of mass concentration and particle number concentration were performed before and during cleaning tasks in two rooms with different floor types (wood and carpet) with the equipment Lighthouse, model 3016 IAQ. Results: Considering mass concentration, particles with higher were responsable for higher leves of contamination, particularly PM5.0 and PM10.0. However, considering the particle number concentration, the smaller particle size obtained the higher values. Conclusion: It was observed higher number of particles of the smaller size in all tasks, which is associated with worse health effects. It was observed that the room with wood in the floor has lower values when compared to the room with carpet. The tasks with greater exposure were the 'vacuuming' and 'clean up powder'.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica com especialização em Energia, Climatização e Refrigeração

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Ciências da Educação Especialidade Intervenção Precoce

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Relatório da Prática Profissional Supervisionada Mestrado em Educação Pré-Escolar

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Relatório da UC Seminário de Apoio à Prática Profissional Supervisionada Mestrado em Educação Pré-Escolar

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Relatório da Prática Profissional Supervisionada Mestrado em Educação Pré-Escolar

Relevância:

10.00% 10.00%

Publicador:

Resumo:

According to numerous studies, airborne nanoparticles have a potential to produce serious adverse human health effects when deposited into the respiratory tract. The most important parts of the lung are the alveolar regions with their enormous surface areas and potential to transfer nanoparticles into the blood stream. These effects may be potentiated in case of the elderly, since this population is more susceptible to air pollutants in general and more to nanoparticles than larger particles. The main goal of this investigation was to determine the exposure of institutionalized elders to nanoparticles using Nanoparticle Surface Area Monitor (NSAM) equipment to calculate the deposited surface area (DSA) of nanoparticles into elderly lungs. In total, 193 institutionalized individuals over 65 yr of age were examined in four elderly care centers (ECC). The occupancy daily pattern was achieved by applying a questionnaire, and it was concluded that these subjects spent most of their time indoors, including the bedroom and living room, the indoor microenvironments with higher prevalence of elderly occupancy. The deposited surface area ranged from 10 to 46 mu m(2)/cm(3). The living rooms presented significantly higher levels compared with bedrooms. Comparing PM10 concentrations with nanoparticles deposited surface area in elderly lungs, it is conceivable that living rooms presented the highest concentration of PM10 and were similar to the highest average DSA. The temporal distribution of DSA was also assessed. While data showed a quantitative fluctuation in values in bedrooms, high peaks were detected in living rooms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Relatório da Prática Profissional Supervisionada Mestrado em Educação Pré-Escolar

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho final de Mestrado para obtenção do grau de mestre em Engenharia Mecânica Ramo de Energia, Refrigeração e Climatização

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The presence of microorganisms in ophthalmic instruments and surfaces can lead to the exposure of patients to several infections. However, there is no information regarding fungal and bacteria contamination in optical shops. This study aims to characterize fungi and bacteria contamination in air and surfaces from 10 optical shops covering also ophthalmic instruments. Air samples were collected through an impaction method onto malt extract agar (MEA) supplemented with chloramphenicol (0.05%) used for fungi and Tryptic Soy Agar (TSA) supplemented with nystatin (0.2%) used for bacteria. Outdoor samples were also performed to be used as reference. Surface and equipment’s swab samples were also collected side-by-side. All the collected samples were incubated at 27ºC for 5 to 7 days (fungi) or at 30º for 7 days (bacteria). Regarding fungal distribution, thirteen different species/genera were found in the air, being the most common Alternaria sp. (62.0%). Eight different species/genera were identified in the surfaces, ranging from 2 to 5x104 CFU/m2, being the most common A. versicolor complex and Penicillium sp. (40.0%). The trial frames were the most contaminated equipment, since 50.0% of the collected samples were with countless colonies. The airborne bacterial population indicated higher concentrations in the contactology office (average: 133 CFU/m3) than in the client’s waiting rooms (average: 126 CFU/m3). The surface samples indicated bacterial concentrations ranging from 2x104 to 1x106 CFU/m2, pointing out the automatic refractometer as the surface with higher bacterial load.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente estudo pretende avaliar a exposição ocupacional a contaminação fúngica e bacteriana em quartos de hotel, mais precisamente em dois quartos com características diferentes, nomeadamente, com pavimento em alcatifa e outro sem alcatifa. Doze amostras de ar de 250L foram colhidas pelo método de impacto, em meio agar de extracto de malte (MEA) suplementado com cloranfenicol (0,05%) para fungos e em meio de TSA (agar de soja tríptica) com nistatina (0,2%) para bactérias. Foram também realizadas amostras de superfície nos mesmos locais. Em ambos os quartos apenas uma amostra de ar, no quarto sem alcatifa, apresentou contagens de fungos mais elevadas do que no exterior. No entanto, as concentrações de bactérias no ar interior foram superiores às do ar exterior. Em relação às superfícies, o quarto sem alcatifa apresentou diferenças estatisticamente significativas em relação ao quarto com alcatifa, sendo que o primeiro apresentou concentrações mais elevadas de fungos. Todas as superfícies analisadas apresentaram contaminação bacteriana, mas não houve diferenças estatisticamente significativas entre os quartos. Os géneros de fungos mais prevalentes no ar foram idênticos em ambos os quartos (Penicillium sp. 40,7% - 12,3% e Cladosporium sp. 43,5% - 55,4%). Nas superfícies analisadas, os isolados pertencentes ao complexo Aspergillus fumigatus foram os únicos encontrados no quarto com alcatifa, enquanto no outro quarto os géneros mais prevalentes foram Penicillium sp. (63,6%) e Aspergillus sp. (13,6%).