11 resultados para nuclear magnetic resonance imaging
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Claustrophobia causes a huge discomfort to those who need to perform Magnetic Resonance examinations mainly due to the physical design of most equipment. This study aimed to maximize the success rate of Magnetic Resonance Imaging (MRI) clinical studies in claustrophobic patients by the identification of facilitative strategies.
Resumo:
The Fast Field-Cycling Nuclear Magnetic Resonance (FFC-NMR) is a technique used to study the molecular dynamics of different types of materials. The main elements of this equipment are a magnet and its power supply. The magnet used as reference in this work is basically a ferromagnetic core with two sets of coils and an air-gap where the materials' sample is placed. The power supply should supply the magnet being the magnet current controlled in order to perform cycles. One of the technical issues of this type of solution is the compensation of the non-linearities associated to the magnetic characteristic of the magnet and to parasitic magnetic fields. To overcome this problem, this paper describes and discusses a solution for the FFC-NMR power supply based on a four quadrant DC/DC converter.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde
Resumo:
A celulose é o polímero renovável mais abundante do mundo. É conhecido pela sua excelente biocompatibilidade, propriedades térmicas e mecânicas. A celulose assim como os polipéptideos e o ADN, pertence a uma família de moléculas orgânicas que dão origem à formação de fases líquidas cristalinas (LCs) colestéricas. A Passiflora Edulis, tal como outras plantas trepadeiras, possui longas e flexíveis gavinhas que permitem à planta encontrar um suporte para se fixar. As gavinhas podem assumir a forma de espirais ou de hélices consoante sejam sustentadas por apenas uma ou por ambas as extremidades. As hélices apresentam muitas vezes duas porções helicoidais, uma esquerda e outra direita, separadas por um segmento recto denominado perversão. Este comportamento é consequência da curvatura intrínseca das gavinhas produzidas pela planta trepadeira. O mesmo comportamento pode ser observado em micro e nanofibras celulósicas fabricadas a partir de soluções líquido-cristalinas, numa escala três a quatro ordens de grandeza inferior à das gavinhas. Este facto sugere que o modelo físico utilizado tenha invariância de escala. Neste trabalho é feito o estudo de fibras e jactos que imitam as estruturas helicoidais apresentadas pelas gavinhas das plantas trepadeiras. As fibras e jactos são produzidos a partir de soluções líquidas cristalinas celulósicas. De modo a determinar as características morfológicas e estruturais, que contribuem para a curvatura das fibras, foram utilizadas técnicas de imagem por ressonância magnética (MRI), microscopia óptica com luz polarisada (MOP), microscopia electrónica de varrimento (SEM) e microscopia de força atómica (AFM) . A variação da forma das estruturas helicoidais com a temperatura parece ser relevante para o fabrico de membranas não tecidas para aplicação em sensores termo-mecânicos.
Resumo:
This paper is a contribution for the assessment and comparison of magnet properties based on magnetic field characteristics particularly concerning the magnetic induction uniformity in the air gaps. For this aim, a solver was developed and implemented to determine the magnetic field of a magnetic core to be used in Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometry. The electromagnetic field computation is based on a 2D finite-element method (FEM) using both the scalar and the vector potential formulation. Results for the magnetic field lines and the magnetic induction vector in the air gap are presented. The target magnetic induction is 0.2 T, which is a typical requirement of the FFC NMR technique, which can be achieved with a magnetic core based on permanent magnets or coils. In addition, this application requires high magnetic induction uniformity. To achieve this goal, a solution including superconducting pieces is analyzed. Results are compared with a different FEM program.
Resumo:
The amount of fat is a component that complicates the clinical evaluation and the differential diagnostic between benign and malign lesions in the breast MRI examinations. To overcome this problem, an effective erasing of the fat signal over the images acquisition process, is essentials. This study aims to compare three fat suppression techniques (STIR, SPIR, SPAIR) in the MR images of the breast and to evaluate the best image quality regarding its clinical usefulness. To mimic breast women, a breast phantom was constructed. First the exterior contour and, in second time, its content which was selected based on 7 samples with different components. Finally it was undergone to a MRI breast protocol with the three different fat saturation techniques. The examinations were performed on a 1.5 T MRI system (Philips®). A group of 5 experts evaluated 9 sequences, 3 of each with fat suppression techniques, in which the frequency offset and TI (Inversion Time) were the variables changed. This qualitative image analysis was performed according 4 parameters (saturation uniformity, saturation efficacy, detail of the anatomical structures and differentiation between the fibroglandular and adipose tissue), using a five-point Likert scale. The statistics analysis showed that anyone of the fat suppression techniques demonstrated significant differences compared to the others with (p > 0.05) and regarding each parameter independently. By Fleiss’ kappa coefficient there was a good agreement among observers P(e) = 0.68. When comparing STIR, SPIR and SPAIR techniques it was confirmed that all of them have advantages in the study of the breast MRI. For the studied parameters, the results through the Friedman Test showed that there are similar advantages applying anyone of these techniques.
Resumo:
Susceptibility Weighted Image (SWI) is a Magnetic Resonance Imaging (MRI) technique that combines high spatial resolution and sensitivity to provide magnetic susceptibility differences between tissues. It is extremely sensitive to venous blood due to its iron content of deoxyhemoglobin. The aim of this study was to evaluate, through the SWI technique, the differences in cerebral venous vasculature according to the variation of blood pressure values. 20 subjects divided in two groups (10 hypertensive and 10 normotensive patients) underwent a MRI system with a Siemens® scanner model Avanto of 1.5T using a synergy head coil (4 channels). The obtained sequences were T1w, T2w-FLAIR, T2* and SWI. The value of Contrast-to-Noise Ratio (CNR) was assessed in MinIP (Minimum Intensity Projection) and Magnitude images, through drawing free hand ROIs in venous structures: Superior Sagittal Sinus (SSS) Internal Cerebral Vein (ICV) and Sinus Confluence (SC). The obtained values were presented in descriptive statistics-quartiles and extremes diagrams. The results were compared between groups. CNR shown higher values for normotensive group in MinIP (108.89 ± 6.907) to ICV; (238.73 ± 18.556) to SC and (239.384 ± 52.303) to SSS. These values are bigger than images from Hypertensive group about 46 a.u. in average. Comparing the results of Magnitude and MinIP images, there were obtained lower CNR values for the hypertensive group. There were differences in the CNR values between both groups, being these values more expressive in the large vessels-SSS and SC. The SWI is a potential technique to evaluate and characterize the blood pressure variation in the studied vessels adding a physiological perspective to MRI and giving a new approach to the radiological vascular studies.
Resumo:
Pretendeu-se contribuir para um melhor entendimento sobre a discussão patente ao redor da Diretiva EMF 2004/40/CE que limita a exposição dos profissionais aos campos eletromagnéticos (CEM) utilizados em Ressonância Magnética (RM). A aplicabilidade da RM será posta em causa se forem impostos, na prática clínica, os limites expressos na diretiva. Foi explorada a evidência científica, sobre a controvérsia gerada em torno do tema. Analisaram-se guidelines, leis e documentos oficiais e foi aplicado um inquérito a 11 grupos profissionais envolvidos na problemática, distribuídos por vários países. Foi construído o diagrama do campo de forças utilizando a aplicação Policymaker K4 health® afim de se especular sobre influências, forças, poder e estratégias desenvolvidas que possam restringir ou facilitar a aplicação da Diretiva. Verificou-se que 62% dos inquiridos desconhece a Diretiva e o seu conteúdo bem como a posição da Sociedade Europeia de Radiologia (ESR) e 69% dos inquiridos não tem acompanhado os desenvolvimentos do tema. Referem não ter conhecimento da ocorrência de incidentes, para além do efeito míssil e do aquecimento devido a Radiofrequência – Specific Absortion Ratio (SAR). Consideram que o impacto político da Diretiva será neutro, mas o impacto clínico e económico serão negativos. Existe uma subestimação geral desta controvérsia e um não reconhecimento das consequências que a aplicação da Diretiva poderá ter na prática clínica. Admite-se o desenvolvimento de estratégias de pressão e influência para com o poder legislativo da Comissão Europeia e do Conselho, quanto a esta matéria.
Resumo:
Liquid crystalline cellulosic-based solutions described by distinctive properties are at the origin of different kinds of multifunctional materials with unique characteristics. These solutions can form chiral nematic phases at rest, with tuneable photonic behavior, and exhibit a complex behavior associated with the onset of a network of director field defects under shear. Techniques, such as Nuclear Magnetic Resonance (NMR), Rheology coupled with NMR (Rheo-NMR), rheology, optical methods, Magnetic Resonance Imaging (MRI), Wide Angle X-rays Scattering (WAXS), were extensively used to enlighten the liquid crystalline characteristics of these cellulosic solutions. Cellulosic films produced by shear casting and fibers by electrospinning, from these liquid crystalline solutions, have regained wider attention due to recognition of their innovative properties associated to their biocompatibility. Electrospun membranes composed by helical and spiral shape fibers allow the achievement of large surface areas, leading to the improvement of the performance of this kind of systems. The moisture response, light modulated, wettability and the capability of orienting protein and cellulose crystals, opened a wide range of new applications to the shear casted films. Characterization by NMR, X-rays, tensile tests, AFM, and optical methods allowed detailed characterization of those soft cellulosic materials. In this work, special attention will be given to recent developments, including, among others, a moisture driven cellulosic motor and electro-optical devices.
Resumo:
This study was developed with the purpose to investigate the effect of polysaccharide/plasticiser concentration on the microstructure and molecular dynamics of polymeric film systems, using transmission electron microscope imaging (TEM) and nuclear magnetic resonance (NMR) techniques. Experiments were carried out in chitosan/glycerol films prepared with solutions of different composition. The films obtained after drying and equilibration were characterised in terms of composition, thickness and water activity. Results show that glycerol quantities used in film forming solutions were responsible for films composition; while polymer/total plasticiser ratio in the solution determined the thickness (and thus structure) of the films. These results were confirmed by TEM. NMR allowed understanding the films molecular rearrangement. Two different behaviours for the two components analysed, water and glycerol were observed: the first is predominantly moving free in the matrix, while glycerol is mainly bounded to the chitosan chain. (C) 2013 Elsevier Ltd. All rights reserved.
Resumo:
The design of magnetic cores can be carried out by taking into account the optimization of different parameters in accordance with the application requirements. Considering the specifications of the fast field cycling nuclear magnetic resonance (FFC-NMR) technique, the magnetic flux density distribution, at the sample insertion volume, is one of the core parameters that needs to be evaluated. Recently, it has been shown that the FFC-NMR magnets can be built on the basis of solenoid coils with ferromagnetic cores. Since this type of apparatus requires magnets with high magnetic flux density uniformity, a new type of magnet using a ferromagnetic core, copper coils, and superconducting blocks was designed with improved magnetic flux density distribution. In this paper, the designing aspects of the magnet are described and discussed with emphasis on the improvement of the magnetic flux density homogeneity (Delta B/B-0) in the air gap. The magnetic flux density distribution is analyzed based on 3-D simulations and NMR experimental results.