10 resultados para new in ILL units
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
A descriptive study was developed in order to compare indoor and outdoor air contamination caused by fungi and particles in seven poultry units. Twenty eight air samples of 25 litters were collected through the impaction method on malt extract agar. Air sampling and particles concentration measurement were done in the interior and also outside premises of the poultries’ pavilions. Regarding the fungal load in the air, indoor concentration of mold was higher than outside air in six poultry units. Twenty eight species / genera of fungi were identified indoor, being Scopulariopsis brevicaulis (40.5%) the most commonly isolated species and Rhizopus sp. (30.0%) the most commonly isolated genus. Concerning outdoor, eighteen species/genera of fungi were isolated, being Scopulariopsis brevicaulis (62.6%) also the most isolated. All the poultry farms analyzed presented indoor fungi different from the ones identified outdoors. Regarding particles’ contamination, PM2.5, PM5.0 and PM10 had a statistically significant difference (Mann-Whitney U test) between the inside and outside of the pavilions, with the inside more contaminated (p=.006; p=.005; p=.005, respectively). The analyzed poultry units are potential reservoirs of substantial amounts of fungi and particles and could therefore free them in the atmospheric air. The developed study showed that indoor air was more contaminated than outdoors, and this can result in emission of potentially pathogenic fungi and particles via aerosols from poultry units to the environment, which may post a considerable risk to public health and contribute to environmental pollution.
Resumo:
Do ponto de vista das preocupações de saúde, os níveis de contaminação do ar interior assumem actualmente uma elevada importância quando se tem em consideração que as pessoas passam a maior parte do seu tempo no interior de edifícios. Neste contexto, o formaldeído é um dos poluentes mais preocupantes e, inclusivamente, os resultados de concentração obtidos em habitações do espaço Europeu foram considerados preocupantes devido ao facto de estarem relacionados com efeitos negativos para a saúde. O estudo exploratório desenvolvido pretendeu disponibilizar informação acerca das concentrações de formaldeído existentes em habitações domésticas portuguesas. Estudou‑se a presença de formaldeído em habitações novas e habitações domésticas com ocupação, abrangendo 6 unidades de cada um dos tipos considerados. Para a avaliação ambiental foi utilizado um equipamento de leitura direta que deteta as concentrações de formaldeído por fotoionização com uma lâmpada de 11,7 eV. A temperatura ambiente e a humidade relativa foram igualmente medidas, de acordo com o estipulado na Norma Internacional ISO 7726:1998. No caso das habitações novas foram registados valores de concentração superiores a 0,08 ppm em 3 das unidades estudadas. Por outro lado, em 4 das habitações com ocupação foram obtidos valores superiores a 0,08 ppm. O desenvolvimento deste estudo permitiu reconhecer algumas das possíveis fontes emissoras e os factores que influenciam as concentrações de formaldeído nas habitações em Portugal. ABSTRACT - Nowadays, indoor air contamination is considering an important health issue considering that people spend most of their time indoors. In this context, formaldehyde is a pollutant of major concern and, recently, concentration results obtained in European dwellings reveal high concentrations and values related with negative health effects in occupants. The present exploratory study sought to provide information about formaldehyde concentrations in Portuguese dwellings. It was studied formaldehyde presence in new dwellings and dwellings with occupation and included 6 units of each setting. For concentrations measure, it was used a direct‑reading equipment that detects formaldehyde concentration by photoionization. Temperature and relative humidity were also measured in accordance with International Standard ISO 7726:1998. In the case of new dwellings, in 3 units concentration values were higher than 0.08 ppm. In addition, in 4 units of the 6 dwellings with occupation, concentrations higher than this reference value were obtained. The development of this study permitted to recognize some of the possible indoors emissions sources and to define several of the preventive measures that can be applied.
Resumo:
Mestrado em Intervenção Sócio-Organizacional na Saúde - Área de especialização: Políticas de Administração e Gestão de Serviços de Saúde
Resumo:
Mestrado em Intervenção Sócio-Organizacional na Saúde - Área de especialização: Políticas de Administração e Gestão de Serviços de Saúde.
Resumo:
Mestrado em Intervenção Sócio-Organizacional na Saúde - Área de especialização: Qualidade e Tecnologias da Saúde.
Resumo:
Mestrado em Radioterapia
Resumo:
In order to correctly assess the biaxial fatigue material properties one must experimentally test different load conditions and stress levels. With the rise of new in-plane biaxial fatigue testing machines, using smaller and more efficient electrical motors, instead of the conventional hydraulic machines, it is necessary to reduce the specimen size and to ensure that the specimen geometry is appropriated for the load capacity installed. At the present time there are no standard specimen’s geometries and the indications on literature how to design an efficient test specimen are insufficient. The main goal of this paper is to present the methodology on how to obtain an optimal cruciform specimen geometry, with thickness reduction in the gauge area, appropriated for fatigue crack initiation, as a function of the base material sheet thickness used to build the specimen. The geometry is optimized for maximum stress using several parameters, ensuring that in the gauge area the stress is uniform and maximum with two limit phase shift loading conditions. Therefore the fatigue damage will always initiate on the center of the specimen, avoiding failure outside this region. Using the Renard Series of preferred numbers for the base material sheet thickness as a reference, the reaming geometry parameters are optimized using a derivative-free methodology, called direct multi search (DMS) method. The final optimal geometry as a function of the base material sheet thickness is proposed, as a guide line for cruciform specimens design, and as a possible contribution for a future standard on in-plane biaxial fatigue tests. © 2014, Gruppo Italiano Frattura. All rights reserved.
Resumo:
Four Cynara cardunculus clones, two from Portugal and two from Spain were studied for biomass production and their lignin was characterized. The clones differed in biomass partitioning: Spanish clones produced more capitula (54.5% vs. 43.9%), and Portuguese clones more stalks (37.2% vs. 25.6%). The heating values (HHV0) of the stalks were similar, ranging from 17.1 to 18.4 MJ/kg. Lignin was studied by analytical pyrolysis (Py-GC/MS(FID)), separately in depithed stalks (stalksDP) and pith. StalksDP had in average higher relative proportions of lignin derived compounds than pith (23.9% vs. 21.8%) with slightly different lignin monomeric composition: pith samples were richer in syringyl units as compared to stalksDP (64% vs. 53%), with S/G ratios of 2.1 and 1.3, respectively. The H:G:S composition was 7:40:53 in stalksDP and 7:29:64 in pith. The lignin content ranged from 18.8% to 25.5%, enabling a differentiation between clones and provenances. © 2015 Elsevier Ltd. All rights reserved.
Resumo:
In order to correctly assess the biaxial fatigue material properties one must experimentally test different load conditions and stress levels. With the rise of new in-plane biaxial fatigue testing machines, using smaller and more efficient electrical motors, instead of the conventional hydraulic machines, it is necessary to reduce the specimen size and to ensure that the specimen geometry is appropriate for the load capacity installed. At the present time there are no standard specimen's geometries and the indications on literature how to design an efficient test specimen are insufficient. The main goal of this paper is to present the methodology on how to obtain an optimal cruciform specimen geometry, with thickness reduction in the gauge area, appropriate for fatigue crack initiation, as a function of the base material sheet thickness used to build the specimen. The geometry is optimized for maximum stress using several parameters, ensuring that in the gauge area the stress distributions on the loading directions are uniform and maximum with two limit phase shift loading conditions (delta = 0 degrees and (delta = 180 degrees). Therefore the fatigue damage will always initiate on the center of the specimen, avoiding failure outside this region. Using the Renard Series of preferred numbers for the base material sheet thickness as a reference, the reaming geometry parameters are optimized using a derivative-free methodology, called direct multi search (DMS) method. The final optimal geometry as a function of the base material sheet thickness is proposed, as a guide line for cruciform specimens design, and as a possible contribution for a future standard on in-plane biaxial fatigue tests
Resumo:
Sampling the total air concentration of particulate matter (PM) only provides a basic estimate of exposure that normally not allows correlating with the observed health effects. Therefore is of great importance to recognize the particles size distribution and, particularly, the exposure to fine particles (≤ 2.5 μm). This particles dimension corresponds to the respirable fraction, the one that can implicate local and systemic effects due to particle deposition and clearance from the lungs and transport within the organism. This study intended to describe occupational exposure to PM2.5 in three units related with swine production and consumption, namely: feed production, swine production and swine slaughterhouse. A size-selective particle measuring in five to six workplaces of each unit was performed. Measurements of PM were done using a portable direct-reading hand-held equipment (Lighthouse, model 3016 IAQ). Data showed slaughterhouse unit with higher values, with values ranging from 0.030 to 0.142 mg/m3 (0.073 + 0.043), being the cutting room the workplace with higher values. In feed production unit, values were between 0.026 and 0.033 mg/m3 (0.028 + 0.003) with the warehouse of pharmacy products as the workplace with higher values. Finally, in swine unit values ranged from 0.006 to 0.048 mg/m3 (0.023 + 0.017) with the batteries area presenting the higher values. PM can be rich in fungi and bacteria and their metabolites, such as endotoxins and mycotoxins. Previous publications already showed high contamination in these occupational settings and particles can have an important role in exposure since can easily act as carrier of these agents. Data acquired allow not only a better prediction of particle penetration into respiratory regions of the respiratory tract, but also a better estimation of PM health effects. Moreover, data permit to identify the workplaces where investment should be made to prevent and reduce exposure.