14 resultados para municipal solid waste management
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre Em Engenharia Química e Biológica Ramo de processos Químicos
Resumo:
Organic waste is a rich substrate for microbial growth, and because of that, workers from waste industry are at higher risk of exposure to bioaerosols. This study aimed to assess fungal contamination in two plants handling solid waste management. Air samples from the two plants were collected through an impaction method. Surface samples were also collected by swabbing surfaces of the same indoor sites. All collected samples were incubated at 27◦C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. Air samples were also subjected to molecular methods by real-time polymerase chain reaction (RT PCR) using an impinger method to measure DNA of Aspergillus flavus complex and Stachybotrys chartarum. Assessment of particulate matter (PM) was also conducted with portable direct-reading equipment. Particles concentration measurement was performed at five different sizes (PM0.5; PM1; PM2.5; PM5; PM10). With respect to the waste sorting plant, three species more frequently isolated in air and surfaces were A. niger (73.9%; 66.1%), A. fumigatus (16%; 13.8%), and A. flavus (8.7%; 14.2%). In the incineration plant, the most prevalent species detected in air samples were Penicillium sp. (62.9%), A. fumigatus (18%), and A. flavus (6%), while the most frequently isolated in surface samples were Penicillium sp. (57.5%), A. fumigatus (22.3%) and A. niger (12.8%). Stachybotrys chartarum and other toxinogenic strains from A. flavus complex were not detected. The most common PM sizes obtained were the PM10 and PM5 (inhalable fraction). Since waste is the main internal fungal source in the analyzed settings, preventive and protective measures need to be maintained to avoid worker exposure to fungi and their metabolites.
Resumo:
Contrary to fungi, exposure to mycotoxins is not usually identified as a risk factor present in occupational settings. This is probably due to the inexistence of limits regarding concentration of airborne mycotoxins, and also due to the fact that these compounds are rarely monitored in occupational environments. Despite the optimal conditions for fungal growth and, consequently, for mycotoxins production in all the waste management chain, only a few articles were dedicated to study occupational exposure to mycotoxins in this occupational setting. Aim of study: A study was developed in Portugal aiming to assess occupational co-exposure to mycotoxins in the waste management setting.
Resumo:
Introduction - Occupational exposures are characterized by being complex and associated to co-exposure to several contaminants by different exposure routes. Even if exposure occurs to only a chemical agent, it can have different exposure routes and can result in different health effects. The waste management setting is recognized by the presence of several chemical and biologic agents in the workplaces. Recently, it was reported occupational exposure to Aflatoxin B1 (AFB1) in one Portuguese waste management industry. However, data regarding to fungal burden showed that exposure to other mycotoxins should be expected. Aim of the study - The aim of the present work was to know if workers from this waste management industry were exposed to other mycotoxins besides AFB1.
Resumo:
A deposição de resíduos sólidos urbanos (RSU) em aterros sanitários (AS) tem uma dimensão que necessita de uma atenção especial por parte da sociedade. Deste acto podem resultar situações gravosas para o meio ambiente se não forem tomadas as medidas correctas. Um dos pontos que necessita de uma particular atenção é o tratamento das águas lixiviantes dos aterros sanitários, uma vez que estas apresentam geralmente cargas altamente poluentes. O presente trabalho apresenta a estrutura de um aterro sanitário, definindo os seus princípios de funcionamento, bem como as principais características a ter em consideração para a sua concepção e construção. É ainda abordada a composição dos resíduos sólidos produzidos em Portugal de acordo com (1) e as características quantitativas e qualitativas do lixiviado produzido por um AS. São apresentados os sistemas tratamento convencionais, biológicos e físico-químicos, mais utilizados em Portugal para o tratamento de águas lixiviantes, relacionando as problemáticas e as limitações associadas a cada um deles. É ainda apresentado o tratamento combinado de águas lixiviantes com águas residuais e a recirculação de lixiviado no sistema de tratamento, assim como algumas das vantagens associadas a estas práticas. Tendo por base, uma situação real, avalia-se um caso de estudo, que visa a avaliação do funcionamento da estação de pré-tratamento das águas lixiviantes produzidas no aterro sanitário do ecoparque de Palmela, tendo em consideração o facto de este tratamento ser realizado em combinação com o tratamento de águas residuais urbanas. A avaliação do funcionamento da estação de pré-tratamento de águas lixiviantes (EPTAL) é realizada de acordo com os dados fornecidos nos relatórios elaborados pela empresa LUSÁGUA, que apresentam os valores das cargas poluentes medidos à entrada e saída da EPTAL, verificando com estes dados se os valores limite de emissão medidos à saída da EPTAL são respeitados. São ainda propostas algumas alterações baseadas em pareceres técnicos que acompanham os relatórios elaborados pela LUSÁGUA e um estudo elaborada pela ECOserviços em Fevereiro de 2010 onde se obtêm eficiências de etapas de tratamentos com base em testes laboratoriais e testes realizados na própria EPTAL.
Resumo:
Composting is an important process of solid waste management and it can be used for treatment of a variety of different wastes (green waste, household waste, sewage sludge and more). This process aims to: 1. Reduce the volumes of waste and; 2. Create a valuable product which can be recycled as a soil amendment in agriculture and gardening. A natural self-heating process involving the biological degradation of organic matter under aerobic conditions. The handling of waste and compost is responsible for the release of airborne microorganisms and their compounds in the air. Possible contaminants: a) Dust; b) Mesophilic and thermophilic microorganisms; c) Volatile organic compounds; d) Endotoxins and mycotoxins…. Aim: assess exposure/contamination to: a) Volatile organic compounds (VOCs); b) Particulate matter (PM); c) Fungi. In a composting plant located in Lisbon. An additional goal was to identify the workplace with higher level of contamination. In a totally indoor composting plant. The composting operations consisted: 1º Waste already sorted is unloaded in a reception area; 2º Pretreatment - remove undesirable materials from the process (glass, rocks, plastics, metals…); 3º Anaerobic digestion; 4º Dehydration; 5º Open composting with forced aeration. All the process takes thirteen weeks.
Resumo:
In the management of solid waste, pollutants over a wide range are released with different routes of exposure for workers. The potential for synergism among the pollutants raises concerns about potential adverse health effects, and there are still many uncertainties involved in exposure assessment. In this study, conventional (culture-based) and molecular real-time polymerase chain reaction (RTPCR) methodologies were used to assess fungal air contamination in a waste-sorting plant which focused on the presence of three potential pathogenic/toxigenic fungal species: Aspergillus flavus, A. fumigatus, and Stachybotrys chartarum. In addition, microbial volatile organic compounds (MVOC) were measured by photoionization detection. For all analysis, samplings were performed at five different workstations inside the facilities and also outdoors as a reference. Penicillium sp. were the most common species found at all plant locations. Pathogenic/toxigenic species (A. fumigatus and S. chartarum) were detected at two different workstations by RTPCR but not by culture-based techniques. MVOC concentration indoors ranged between 0 and 8.9 ppm (average 5.3 ± 3.16 ppm). Our results illustrated the advantage of combining both conventional and molecular methodologies in fungal exposure assessment. Together with MVOC analyses in indoor air, data obtained allow for a more precise evaluation of potential health risks associated with bioaerosol exposure. Consequently, with this knowledge, strategies may be developed for effective protection of the workers.
Resumo:
O presente documento enquadra-se no âmbito do trabalho final do mestrado (TFM) do curso de Engenharia Civil, na área de especialização de Hidráulica, do Instituto Superior de Engenharia de Lisboa, sob a forma de um projeto na fase de estudo prévio com o título ―Gestão Sustentável da Água no empreendimento turístico Parque de Campismo da Ilha do Pessegueiro situado em Porto Covo - Região de Turismo do Alentejo‖. Este trabalho é constituído essencialmente por 5 partes. Sendo a primeira uma breve introdução às questões a abordar, a segunda corresponde à discrição teórica do uso eficiente da água baseando-se no PNEUA (Programa nacional para o uso eficiente da água). Já a terceira parte é relativa ao atual sistema de utilização da água no Parque de campismo da ilha do pessegueiro (PCIP), sendo a quarta o estudo do desenvolvimento do projecto para a gestão eficiente da água no empreendimento e a quinta parte o estudo de viabilidade económica e financeira a implementar no projecto. Para além da implementação de medidas de poupança são também objetivos principais deste trabalho a reutilização da água através da recolha, o tratamento e armazenamento das águas residuais e aproveitamento das águas pluviais para posterior abastecimento do sistema de utilização em descargas sanitárias, lavagem de pavimentos e regas de espaços verdes. São, portanto, três os subsistemas de gestão eficiente da água que se pretende implementar. Dá-se importância ao estudo de viabilidade económica do projeto, cujo período de retorno do capital investido em capitais próprios e alheios é de seis anos. Este projeto pretende dar apoio técnico ao uso eficiente da água no PCIP, de forma a conseguir por um lado obter vantagens económicas e por outro proteger o ambiente. As vantagens económicas são interessantes para orientar os recursos financeiros para outros investimentos e as questões ambientais são a base de uma campanha, já em curso, para obtenção de certificação energética, em conjunto com outras práticas já em curso, nomeadamente a recolha seletiva de resíduos sólidos para recircular e aproveitamento de energia solar.
Resumo:
Aflatoxin B1 (AFB1) is considered by different International Agencies as a genotoxic and potent hepatocarcinogen. However, despite the fact that the fungi producing this compound are detected in some work environments, AFB1 is rarely monitored in occupational settings. The aim of the present investigation was to assess exposure to AFB1 of workers from one Portuguese waste company located in the outskirt of Lisbon. Occupational exposure assessment to AFB1 was done with a biomarker of internal dose that measures AFB1 in the serum by enzyme-linked immunosorbent assay. Forty-one workers from the waste company were enrolled in this study (26 from sorting; 9 from composting; 6 from incineration). A control group (n = 30) was also considered in order to know the AFB1 background levels for the Portuguese population. All the workers showed detectable levels of AFB1 with values ranging from 2.5ng ml−1 to 25.9ng ml−1 with a median value of 9.9±5.4ng ml−1. All of the controls showed values below the method’s detection limit. Results obtained showed much higher (8-fold higher) values when compared with other Portuguese settings already studied, such as poultry and swine production. Besides this mycotoxin, other mycotoxins are probably present in this occupational setting and this aspect should be taken into consideration for the risk assessment process due to possible synergistic reactions. The data obtained suggests that exposure to AFB1 occurs in a waste management setting and claims attention for the need of appliance of preventive and protective safety measures.
Resumo:
Objectives - This study intended to characterize work environment contamination by particles in 2 waste-sorting plants. Material and Methods - Particles were measured by portable direct-reading equipment. Besides mass concentration in different sizes, data related with the number of particles concentration were also obtained. Results - Both sorting units showed the same distribution concerning the 2 exposure metrics: particulate matter 5 (PM5) and particulate matter 10 (PM10) reached the highest levels and 0.3 μm was the fraction with a higher number of particles. Unit B showed higher (p < 0.05) levels for both exposure metrics. For instance, in unit B the PM10 size is 9-fold higher than in unit A. In unit A, particulate matter values obtained in pre-sorting and in the sequential sorting cabinet were higher without ventilation working. Conclusions - Workers from both waste-sorting plants are exposed to particles. Particle counting provided additional information that is of extreme value for analyzing the health effects of particles since higher values of particles concentration were obtained in the smallest fraction.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil, na Área de Especialização de Hidráulica
Resumo:
High loads of fungi have been reported in different types of waste management plants. This study intends to assess fungal contamination in one waste-sorting plant before and after cleaning procedures in order to analyze their effectiveness. Air samples of 50 L were collected through an impaction method, while surface samples, taken at the same time, were collected by the swabbing method and subject to further macro- and microscopic observations. In addition, we collected air samples of 250 L using the impinger Coriolis μ air sampler (Bertin Technologies) at 300 L/min airflow rate in order to perform real-time quantitative PCR (qPCR) amplification of genes from specific fungal species, namely Aspergillus fumigatus and Aspergillus flavus complexes, as well as Stachybotrys chartarum species. Fungal quantification in the air ranged from 180 to 5,280 CFU m−3 before cleaning and from 220 to 2,460 CFU m−3 after cleaning procedures. Surfaces presented results that ranged from 29 × 104 to 109 × 104 CFU m−2 before cleaning and from 11 × 104 to 89 × 104 CFU m−2 after cleaning. Statistically significant differences regarding fungal load were not detected between before and after cleaning procedures. Toxigenic strains from A. flavus complex and S. chartarum were not detected by qPCR. Conversely, the A. fumigatus species was successfully detected by qPCR and interestingly it was amplified in two samples where no detection by conventional methods was observed. Overall, these results reveal the inefficacy of the cleaning procedures and that it is important to determine fungal burden in order to carry out risk assessment.
Resumo:
Aspergillus fumigatus is one of the major ubiquitous saprophytic fungi and it is considered one of the fungal species with higher clinical relevance. This study aimed at characterising the prevalence of A. fumigatus complex in one waste-sorting plant and also in one incineration plant. Conventional and molecular methodologies were applied in order to detect its presence. Aspergillus fumigatus complex was the second most frequently found in the air from the waste-sorting plant (16.0%) and from the incineration plant (18.0%). Regarding surfaces, it ranked the third species most frequently found in the waste-sorting plant (13.8%) and the second in the incineration plant (22.3%). In the waste-sorting plant, it was possible to amplify by qPCR DNA from the A. fumigatus complex in all culture-positive sampling sites plus one other sampling site that was negative by culture analysis. Considering the observed fungal load, it is recommended to apply preventive and protective measures in order to avoid or minimise worker's exposure.
Resumo:
Relatório de estágio para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Edificações