9 resultados para isolated systolic hypertension
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
The volatiles from Coriandrum sativum L., Satureja montana L., Santolina chamaecyparissus L., and Thymus vulgaris L. were isolated by hydrodistillation (essential oil) and supercritical fluid extraction (volatile oil). Their effect on seed germination and root and shoot growth of the surviving seedlings of four crops (Zea mays L., Triticum durum L., Pisum sativum L., and Lactuca sativa L.) and two weeds (Portulaca oleracea L. and Vicia sativa L.) was investigated and compared with those of two synthetic herbicides, Agrocide and Prowl. The volatile oils of thyme and cotton lavender seemed to be promising alternatives to the synthetic herbicides because they were the least injurious to the crop species. The essential oil of winter savory, on the other hand, affected both crop and weeds and can be appropriate for uncultivated fields.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Área de especialização: Ultrassonografia Cardiovascular.
Resumo:
Introdução – A medição da pressão arterial (PA), utilizando dispositivos automáticos, é frequentemente realizada na prática clínica e na automedição, permitindo adquirir informação fiável para o diagnóstico, controlo e tratamento da hipertensão arterial. Porém, muitos dos dispositivos automáticos disponíveis no mercado não estão validados segundo protocolos existentes para o efeito. O objetivo do estudo foi confirmar a validação do dispositivo de medição automática da PA, OMRON® M6 Comfort, segundo o Protocolo Internacional da European Society of Hypertension (ESH), de 2010, para a validação de dispositivos de medição automática da PA em adultos. Metodologia – Foram estudados 33 indivíduos, aos quais foram realizadas 9 medições sequenciais da PA, no braço esquerdo, com um esfignomanómetro aneróide alternando com o dispositivo automático. Seguidamente avaliaram-se as diferenças entre os valores obtidos pelos dispositivos para a pressão arterial sistólica (PAS) e diastólica (PAD), classificando-as em três níveis (≤ 5, ≤ 10 ou ≤ 15 mmHg). O número das diferenças em cada nível foi comparado ao requerido pelo Protocolo (fase 1.1). Para cada sujeito foi ainda determinado o número de diferenças com valores ≤ 5 mmHg. Pelo menos 24 dos 33 indivíduos devem ter 2 ou 3 diferenças com valores ≤ 5 mmHg e no máximo 3 dos 33 indivíduos podem apresentar as 3 diferenças com valores > 5 mmHg (fase 1.2). Resultados – O dispositivo OMRON® M6 Comfort foi aprovado nas fases 1.1 e 1.2 para a PAS e PAD. A média das diferenças entre as medições da PA, determinada pelos dispositivos automático e manual, foi de -0,82 ± 5,62 mmHg para a PAS e 2,14 ± 5,15 mmHg para a PAD. Considerações Finais – O dispositivo OMRON® M6 Comfort é válido para a medição da PA em adultos, de acordo com o Protocolo Internacional da ESH, de 2010. - ABSTRACT - Introduction – The measurement of blood pressure (BP) using automatic devices is often performed in clinical practice and self-measurement allowing the acquisition of reliable information for the diagnosis, monitoring and treatment of hypertension. However not all of the automated devices available in the market are validated in accordance with the existing protocols for this purpose. The purpose of this study was to confirm the validation of the automatic measuring device of the BP, OMRON® M6 Comfort, according to the “European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults”. Methodology – The study involved 33 subjects, in each one of them, 9 sequential measurements of BP were performed, in the left arm, with the aneroid sphygmomanometer alternating with the automatic device. Afterwards, the differences on the values obtained by the different devices were evaluated, for systolic blood pressure (SBP) and diastolic (DBP), and these differences were then classified into three levels (≤ 5, ≤ 10 or ≤ 15 mmHg). The number of differences at each level was compared to the number required by the protocol (phase 1.1). For each subject the number of differences with values ≤ 5 mmHg was also determined. At least 24 of the 33 subjects should have 2 or 3 differences with values ≤ 5 mmHg and a maximum of 3 of the 33 subjects may have all differences with values > 5 mmHg (phase 1.2). Results – The device OMRON M6 Comfort ® was approved in phases 1.1 and 1.2 for SBP and DBP. The average difference between measurements of BP, as determined by automatic and manual devices, was -0.82 ± 5.62 mmHg for SBP and 2.14 ± 5.15 mmHg for DBP. Conclusion – The device OMRON M6 Comfort® is valid for measuring BP in adults, according to the ESH International Protocol of 2010.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Área de especialização: Ultrassonografia Cardiovascular.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Ultrassonografia Cardiovascular
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Ultrassonografia Cardiovascular
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Ultrassonografia Cardiovascular
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Ultrassonografia Cardiovascular
Resumo:
Most of small islands around the world today, are dependent on imported fossil fuels for the majority of their energy needs especially for transport activities and electricity production. The use of locally renewable energy resources and the implementation of energy efficiency measures could make a significant contribution to their economic development by reducing fossil fuel imports. An electrification of vehicles has been suggested as a way to both reduce pollutant emissions and increase security of supply of the transportation sector by reducing the dependence on oil products imports and facilitate the accommodation of renewable electricity generation, such as wind and, in the case of volcanic islands like Sao Miguel (Azores) of the geothermal energy whose penetration has been limited by the valley electricity consumption level. In this research, three scenarios of EV penetration were studied and it was verified that, for a 15% LD fleet replacement by EVs with 90% of all energy needs occurring during the night, the accommodation of 10 MW of new geothermal capacity becomes viable. Under this scenario, reductions of 8% in electricity costs, 14% in energy, 23% in fossil fuels use and CO2 emissions for the transportation and electricity production sectors could be expected.