39 resultados para interest point detectors
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Mestrado em Gestão e Empreendedorismo
Resumo:
Renal scintigraphy with 99mTc-dimercaptosuccinic acid (99mTc-DMSA) is performed with the aim of detect cortical abnormalities related to urinary tract infection and accurately quantify relative renal function (RRF). For this quantitative assessment Nuclear Medicine Technologist should draw regions of interest (ROI) around each kidney (KROI) and peri-renal background (BKG) ROI, although, controversy still exists about BKG-ROI. The aim of this work was to evaluate the effect of the normalization procedure, number and location of BKG-ROI on the RRF in 99mTc-DMSA scintigraphy.
Resumo:
In the Sparse Point Representation (SPR) method the principle is to retain the function data indicated by significant interpolatory wavelet coefficients, which are defined as interpolation errors by means of an interpolating subdivision scheme. Typically, a SPR grid is coarse in smooth regions, and refined close to irregularities. Furthermore, the computation of partial derivatives of a function from the information of its SPR content is performed in two steps. The first one is a refinement procedure to extend the SPR by the inclusion of new interpolated point values in a security zone. Then, for points in the refined grid, such derivatives are approximated by uniform finite differences, using a step size proportional to each point local scale. If required neighboring stencils are not present in the grid, the corresponding missing point values are approximated from coarser scales using the interpolating subdivision scheme. Using the cubic interpolation subdivision scheme, we demonstrate that such adaptive finite differences can be formulated in terms of a collocation scheme based on the wavelet expansion associated to the SPR. For this purpose, we prove some results concerning the local behavior of such wavelet reconstruction operators, which stand for SPR grids having appropriate structures. This statement implies that the adaptive finite difference scheme and the one using the step size of the finest level produce the same result at SPR grid points. Consequently, in addition to the refinement strategy, our analysis indicates that some care must be taken concerning the grid structure, in order to keep the truncation error under a certain accuracy limit. Illustrating results are presented for 2D Maxwell's equation numerical solutions.
Resumo:
During the last two decades screen-film (SF) systems have been replaced by digital X-ray systems. The advent of digital technologies brought a number of digital solutions based on different detector and readout technologies. Improvements in technology allowed the development of new digital technologies for projection radiography such as computed radiography (CR) and digital radiography (DR). The large number of scientific papers concerning digital X-ray systems that have been published over the last 25 years indicates the relevance of these technologies in healthcare. There are important differences among different detector technologies that may affect system performance and image quality for diagnostic purposes. Radiographers are expected to have an effective understanding of digital X-ray technologies and a high level of knowledge and awareness concerning the capabilities of these systems. Patient safety and reliable diagnostic information are intrinsically linked to these factors. In this review article - which is the first of two parts - a global overview of the digital radiography systems (both CR and DR) currently available for clinical practice is provided.
Resumo:
Digital X-ray detector technologies provide several advantages when compared with screen-film (SF) systems: better diagnostic quality of the radiographic image, increased dose efficiency, better dynamic range and possible reduction of radiation exposure to the patient. The transition from traditional SF systems to digital technology-based systems highlights the importance of the discussion around technical factors such as image acquisition, themanagement of patient dose and diagnostic image quality. Radiographers should be aware of these aspects concerning their clinical practice regarding the advantages and limitations of digital detectors. Newdigital technologies require an up-to-date of scientific knowledge concerning their use in projection radiography. This is the second of a two-part review article focused on a technical overview of digital radiography detectors. This article provides a discussion about the issues related to the image acquisition requirements and advantages of digital technologies, the management of patient dose and the diagnostic image quality.
Resumo:
O crescimento da utilização de accionamentos electromecânicos de velocidade variável entre outros dispositivos que necessitam de tensões elevadas, na ordem dos kV e com elevados níveis de qualidade, despertou o interesse pelos conversores multinível. Este tipo de conversor consegue alcançar elevadas tensões de funcionamento e simultaneamente melhorar a qualidade das formas de onda de tensão e corrente nas respectivas fases. Esta dissertação de mestrado tem por objectivo apresentar um estudo sobre o conversor multinível com díodos de ligação ao neutro (NPC – neutral point clamped), de cinco níveis utilizado como ondulador de tensão ligado à rede. O trabalho começa por desenvolver o modelo matemático do conversor multinível com díodos de ligação ao neutro de cinco níveis e a respectiva interligação com a rede eléctrica. Com base no modelo do conversor são realizadas simulações numéricas desenvolvidas em Matlab-Simulink. Para controlo do trânsito de energia no conversor é utilizando controlo por modo de deslizamento aplicado às correntes nas fases. As simulações efectuadas são comparadas com resultados de simulação obtidos para um ondulador clássico de dois níveis. Resultados de simulação do conversor multinível são posteriormente comparados com resultados experimentais para diferentes valores de potências activa e reactiva. Foi desenvolvido um protótipo experimental de um conversor multinível com díodos de ligação ao neutro de cinco níveis e a respectiva electrónica associada para comando e disparo dos semicondutores de potência.
Resumo:
The spectral response and the photocurrent delivered by entirely microcrystalline p-i-n-Si:H detectors an analysed under different applied bias and light illumination conditions. The spectral response and the internal collection depend not only on the energy range but also on the illumination side. Under [p]- and [n]-side irradiation, the internal collection characteristics have an atypical shape. It is high for applied bias and lower than the open circuit voltage, shows a steep decrease near the open circuit voltage (higher under [n]-side illumination) and levels off for higher voltages. Additionally, the numerical modeling of the VIS/NIR detector, based on the band discontinuities near the grain boundaries and interfaces, complements the study and gives insight into the internal physical process.
Resumo:
Interest rate risk is one of the major financial risks faced by banks due to the very nature of the banking business. The most common approach in the literature has been to estimate the impact of interest rate risk on banks using a simple linear regression model. However, the relationship between interest rate changes and bank stock returns does not need to be exclusively linear. This article provides a comprehensive analysis of the interest rate exposure of the Spanish banking industry employing both parametric and non parametric estimation methods. Its main contribution is to use, for the first time in the context of banks’ interest rate risk, a nonparametric regression technique that avoids the assumption of a specific functional form. One the one hand, it is found that the Spanish banking sector exhibits a remarkable degree of interest rate exposure, although the impact of interest rate changes on bank stock returns has significantly declined following the introduction of the euro. Further, a pattern of positive exposure emerges during the post-euro period. On the other hand, the results corresponding to the nonparametric model support the expansion of the conventional linear model in an attempt to gain a greater insight into the actual degree of exposure.
Resumo:
Financial literature and financial industry use often zero coupon yield curves as input for testing hypotheses, pricing assets or managing risk. They assume this provided data as accurate. We analyse implications of the methodology and of the sample selection criteria used to estimate the zero coupon bond yield term structure on the resulting volatility of spot rates with different maturities. We obtain the volatility term structure using historical volatilities and Egarch volatilities. As input for these volatilities we consider our own spot rates estimation from GovPX bond data and three popular interest rates data sets: from the Federal Reserve Board, from the US Department of the Treasury (H15), and from Bloomberg. We find strong evidence that the resulting zero coupon bond yield volatility estimates as well as the correlation coefficients among spot and forward rates depend significantly on the data set. We observe relevant differences in economic terms when volatilities are used to price derivatives.
Resumo:
O crescente número de automóveis nas ruas das grandes cidades, assim como o crescente número de transportes urbanos para atender o crescimento das populações, veio fazer com que as cidades cada vez mais fiquem mais congestionadas e mais propícias para acidentes envolvendo viaturas e peões. Devido a isso, foram criados sistemas de controlo de tráfego capazes de melhorar o tráfego urbano nas cidades, sem deixar de lado as preocupações com os peões e nem com as emissões de poluentes para o ar. Baseado nesse cenário, este trabalho tem como objetivo abordar as possíveis soluções existentes no mercado para melhorar o fluxo das viaturas, principalmente dos transportes colectivos, com prioridades para viaturas de emergências e autocarros, assim como, as passagens de peões, e sistemas de mobilidade urbana. Desempenho do transporte público pode ser melhorado através de um melhor controlo e gerenciamento de tráfego em geral. Nos testes realizados em campo: foi medida a velocidade de viagem do autocarro no cruzamento fixo (Praça de Espanha), e correlacionando-os com intervalos do ciclo dos semáforos para este cruzamento. A flexibilidade do controlador actuando, com o auxílio de detectores de veículos, sendo capaz de variar os intervalos dentro do ciclo, bem como o volume de carros e de prestações em velocidade de viagem do autocarro. Resultados mostram que, durante o período em estudo, os benefícios de velocidade da viagem do autocarro, seria possível, através de um verdadeiro controlo de tempo feedback de cooperação entre as áreas urbanas de controlo de tráfego (Gertrude) e do sistema de localização de veículos de transportes públicos (SAEIP). Ao longo prazo, sugerimos a implantação de um sistema integrado. Fazendo com que o volume no carro seja reduzido. Este efeito leva também, a um aumento da velocidade comercial do autocarro urbano, da mesma forma como foi proposto em nossa experiência.
Resumo:
The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to increased interest in in vivo small animal imaging. Small animal imaging has been applied frequently to the imaging of small animals (mice and rats), which are ubiquitous in modeling human diseases and testing treatments. The use of PET in small animals allows the use of subjects as their own control, reducing the interanimal variability. This allows performing longitudinal studies on the same animal and improves the accuracy of biological models. However, small animal PET still suffers from several limitations. The amounts of radiotracers needed, limited scanner sensitivity, image resolution and image quantification issues, all could clearly benefit from additional research. Because nuclear medicine imaging deals with radioactive decay, the emission of radiation energy through photons and particles alongside with the detection of these quanta and particles in different materials make Monte Carlo method an important simulation tool in both nuclear medicine research and clinical practice. In order to optimize the quantitative use of PET in clinical practice, data- and image-processing methods are also a field of intense interest and development. The evaluation of such methods often relies on the use of simulated data and images since these offer control of the ground truth. Monte Carlo simulations are widely used for PET simulation since they take into account all the random processes involved in PET imaging, from the emission of the positron to the detection of the photons by the detectors. Simulation techniques have become an importance and indispensable complement to a wide range of problems that could not be addressed by experimental or analytical approaches.
Resumo:
Chromium oxides, CrxOy, are of great interest due to the wide variety of their technological applications. Among them, CrO2 has been extensively investigated in recent years because it is an attractive compound for use in spintronic heterostructures. However, its synthesis at low temperatures has been a difficult task due to the metastable nature of this oxide. This is indeed essential to ensure interface quality and the ability to coat thermal-sensitive materials such as those envisaged in spintronic devices. Pulsed Laser Deposition (PLD) is a technique that has the potential to meet the requirements stated above. In this work, we describe our efforts to grow chromium oxide thin films by PLD from Cr8O21 targets, using a KrF excimer laser. The as-deposited films were investigated by X-ray diffraction and Rutherford backscattering spectrometry. Structural and chemical composition studies showed that the films consist of a mixture of amorphous chromium oxides exhibiting different stoichiometries depending on the processing parameters, where nanocrystals of mainly Cr2O3 are dispersed. The analyses do not exclude the possibility of co-deposition of Cr2O3 and a low fraction of CrO2.
Resumo:
Developments in digital detector technologies have been taking place and new digital technologies are available for clinical practice. This chapter is intended to give a technical state-of-the-art overview about computed radiography (CR) and digital radiography (DR) detectors. CR systems use storage-phosphor image plates with a separate image readout process and DR technology converts X-rays into electrical charges by means of a readout process using TFT arrays. Digital detectors offer several advantages when compared to analogue detectors. The knowledge about digital detector technology for use in plain radiograph examinations is thus a fundamental topic to be acquired by radiology professionals and students. In this chapter an overview of digital radiography systems (both CR and DR) currently available for clinical practice is provided.
Resumo:
This paper presents a step-up micro-power converter for solar energy harvesting applications. The circuit uses a SC voltage tripler architecture, controlled by an MPPT circuit based on the Hill Climbing algorithm. This circuit was designed in a 0.13 mu m CMOS technology in order to work with an a-Si PV cell. The circuit has a local power supply voltage, created using a scaled down SC voltage tripler, controlled by the same MPPT circuit, to make the circuit robust to load and illumination variations. The SC circuits use a combination of PMOS and NMOS transistors to reduce the occupied area. A charge re-use scheme is used to compensate the large parasitic capacitors associated to the MOS transistors. The simulation results show that the circuit can deliver a power of 1266 mu W to the load using 1712 mu W of power from the PV cell, corresponding to an efficiency as high as 73.91%. The simulations also show that the circuit is capable of starting up with only 19% of the maximum illumination level.
Resumo:
Renal scintigraphy with 99mTc-dimercaptosuccinic acid (99mTc-DMSA) is performed with the aim of detect cortical abnormalities related to urinary tract infection and accurately quantify relative renal function (RRF). For this quantitative assessment Nuclear Medicine Technologist should draw regions of interest (ROI) around each kidney (KROI) and peri-renal background (BKG) ROI although controversy still exists about BKG-ROI. The aim of this work was to evaluate the effect of the normalization procedure, number and location of BKG-ROI on the RRF in 99mTc-DMSA scintigraphy.