24 resultados para indoor mobility course

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Bologna Process aimed to build a European Higher Education Area with the objective of promoting students mobility. The adoption of Bologna Declaration directives requires a decentralized approach that accelerates student's mobility, based on frequently updated legislation. This paper proposes a student personal system to manage student's academic information. This system is supported by a flexible model that integrates, for instance, knowledge about the student attended courses or about a course that the student wishes to apply. Essentially, this model holds a (i) Student's Academic Record with skills acquired in academic course units, professional experience or training and an (ii) Individual Studies Plan, which places the student in a particular (iii) Course Plan setting the curricular structure that the student wishes to apply.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fungal contamination of air in 10 gymnasiums with swimming pools was monitored. Fifty air samples of 200 L each were collected, using a Millipore air tester, from the area surrounding the pool, in training studios, in showers and changing rooms for both sexes, and also, outside premises, since these are the places regarded as reference. Simultaneously, environmental parameters – temperature and humidity – were also monitored. Some 25 different species of fungi were identified. The six most commonly isolated genera were the following: Cladosporium sp. (36.6%), Penicillium sp. (19.0%), Aspergillus sp. (10.2%), Mucor sp. (7%), Phoma sp. and Chrysonilia sp. (3.3%). For yeasts, three different genera were identified, namely, Rhodotorula sp. (70%), Trichosporon mucoides and Cryptococcus uniguttulattus (10%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Formaldehyde was the first air pollutant, which already in the 1970s emerged as a specifically non-industrial indoor air quality problem. Yet formaldehyde remained an indoor air quality issue and the formaldehyde level in residential indoor air is among the highest of any indoor air contaminant. Formaldehyde concentrations in 4 different indoor settings (schools, office buildings, new dwellings and occupied dwellings) in Portugal were measured using Photo Ionization Detection (PID) equipment (11,7 eV lamps). All the settings presented results higher than the reference value proposed by Portuguese legislation. Furthermore, occupied dwellings showed 3 units with results above the reference. We could conclude that formaldehyde presence is a reality in monitored indoor settings. Concentration levels are higher than the Portuguese reference value for indoor settings and these can indicate health problems for occupants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A biomonitoring study, using transplanted lichens Flavoparmelia caperata, was conducted to assess the indoor air quality in primary schools in urban (Lisbon) and rural (Ponte de Sor) Portuguese sites. The lichens exposure period occurred between April and June 2010 and two types of environments of the primary schools were studied: classrooms and outdoor/courtyard. Afterwards, the lichen samples were processed and analyzed by instrumental neutron activation analysis (INAA) to assess a total of 20 chemical elements. Accumulated elements in the exposed lichens were assessed and enrichment factors (EF) were determined. Indoor and outdoor biomonitoring results were compared to evaluate how biomonitors (as lichens) react at indoor environments and to assess the type of pollutants that are prevalent in those environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total particulate matter (TPM) was passively collected inside two classrooms of each of five elementary schools in Lisbon, Portugal. TPM was collected in polycarbonate filters with a 47 mm diameter, placed inside of uncovered plastic petri dishes. The sampling period was from 19 May to 22 June 2009 (35 days exposure) and the collected TPM masses varied between 0.2 mg and 0.8 mg. The major elements were Ca, Fe, Na, K, and Zn at μg level, while others were at ng level. Pearson′s correlation coefficients above 0.75 (a high degree of correlation) were found between several elements. Soil-related, traffic soil re-suspension and anthropogenic emission sources could be identified. Blackboard chalk was also identified through Ca large presence. Some of the determined chemical elements are potential carcinogenic. Quality control of the results showed good agreement as confirmed by the application of u-score test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clean air is a basic requirement of life. The Indoor Air Quality (IAQ) has been the object of several studies due to an increasing concern within the scientific community on the effects of indoor air quality upon health, especially as people tend to spend more time indoors than outdoors. The quality of air inside homes, offices, schools or other private and public buildings is an essential determinant of healthy life and people’s well-being. People can be exposed to contaminants by inhalation, ingestion and dermal contact. In the past, scientists have paid much attention to the study of exposure to outdoor air contaminants, because they have realised the seriousness of outdoor air pollution problems. However, each indoor microenvironment has unique characteristics, determined by the local outdoor air, specific building characteristics and indoor activities. Indeed, hazardous substances are emitted from buildings, construction materials and indoor equipment or due to human activities indoors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As redes de telecomunicações nos últimos anos têm sofrido um grande desenvolvimento a nível tecnológico. A prova disso é a revolução das redes sem fios, iniciada com a tecnologia GSM (Global System Mobile) nos anos 90, na qual eram apenas disponibilizados serviços de voz. Esta tendência continuou com o GPRS (General Packet Radio Service) onde se iniciaram os serviços de dados surgindo assim mais tarde, a tecnologia UMTS (Universal Mobile Telecommunications System). Com o aparecimento da nova tecnologia LTE (Long-Term Evolution), surgiu um novo paradigma consumista no mercado, facto que gerou um conflicto directo com as redes de banda larga (ADSL - Asymmetric Digital Subscriber Line) fornecidas anteriormente apenas pela rede fixa. A partir deste momento, estas duas tecnologias passaram a oferecer altos débitos de dados, eliminando assim esta diferenciação existente até então entre ambas. Esta foi a plataforma que despoletou o meu interesse em explorar a tecnologia LTE, mais precisamente, o planeamento de rádio em ambientes Indoor e Outdoor. Este planeamento requeria uma comparação prática e teórica, de forma a observar que a tecnologia reflectia os valores estipulados na norma LTE. Como método de comparação foi utilizada uma ferramenta de planeamento de redes móveis, gentilmente disponibilizada pela Alcatel-Lucent para o tipo de ambiente outdoor em estudo, para o indoor não foi efectuado simulação, por indisponibilidade da ferramenta. Após a configuração do sistema de rádio foi efectuada a recolha de dados no terreno através de drive-testes. Findo esta fase, procedeu-se ao pós-processamento e análise dos dados recolhidos, por forma a ser possível estabelecer a comparação entre o planeamento teórico efectuado através da ferramenta de planeamento e os dados capturados no terreno. Os resultados obtidos demonstram que a cobertura preconizada no caso Outdoor estavam de acordo com o planeamento efectuado, uma vez que os dados medidos no terreno coincidiram com os valores simulados, apenas com um desvio mínimo dentro da margem de tolerância. No que respeita ao indoor verificou-se que as medidas estavam de acordo com o estipulado na norma. Como conclusão, confirmou-se a validade das ferramentas e da metodologia utilizada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was the assessment of exposure to ultrafine in the urban environment of Lisbon, Portugal, due to automobile traffic, and consisted of the determination of deposited alveolar surface area in an avenue leading to the town center during late spring. This study revealed differentiated patterns for weekdays and weekends, which could be related with the fluxes of automobile traffic. During a typical week, ultrafine particles alveolar deposited surface area varied between 35.0 and 89.2 μm2/cm3, which is comparable with levels reported for other towns such in Germany and the United States. These measurements were also complemented by measuring the electrical mobility diameter (varying from 18.3 to 128.3 nm) and number of particles that showed higher values than those previously reported for Madrid and Brisbane. Also, electron microscopy showed that the collected particles were composed of carbonaceous agglomerates, typical of particles emitted by the exhaustion of diesel vehicles. Implications: The approach of this study considers the measurement of surface deposited alveolar area of particles in the outdoor urban environment of Lisbon, Portugal. This type of measurements has not been done so far. Only particulate matter with aerodynamic diameters <2.5 (PM2.5) and >10 (PM10) μm have been measured in outdoor environments and the levels found cannot be found responsible for all the observed health effects. Therefore, the exposure to nano- and ultrafine particles has not been assessed systematically, and several authors consider this as a real knowledge gap and claim for data such as these that will allow for deriving better and more comprehensive epidemiologic studies. Nanoparticle surface area monitor (NSAM) equipments are recent ones and their use has been limited to indoor atmospheres. However, as this study shows, NSAM is a very powerful tool for outdoor environments also. As most lung diseases are, in fact, related to deposition of the alveolar region of the lung, the metric used in this study is the ideal one.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A descriptive study was developed in order to compare indoor and outdoor air contamination caused by fungi and particles in seven poultry units. Twenty eight air samples of 25 litters were collected through the impaction method on malt extract agar. Air sampling and particles concentration measurement were done in the interior and also outside premises of the poultries’ pavilions. Regarding the fungal load in the air, indoor concentration of mold was higher than outside air in six poultry units. Twenty eight species / genera of fungi were identified indoor, being Scopulariopsis brevicaulis (40.5%) the most commonly isolated species and Rhizopus sp. (30.0%) the most commonly isolated genus. Concerning outdoor, eighteen species/genera of fungi were isolated, being Scopulariopsis brevicaulis (62.6%) also the most isolated. All the poultry farms analyzed presented indoor fungi different from the ones identified outdoors. Regarding particles’ contamination, PM2.5, PM5.0 and PM10 had a statistically significant difference (Mann-Whitney U test) between the inside and outside of the pavilions, with the inside more contaminated (p=.006; p=.005; p=.005, respectively). The analyzed poultry units are potential reservoirs of substantial amounts of fungi and particles and could therefore free them in the atmospheric air. The developed study showed that indoor air was more contaminated than outdoors, and this can result in emission of potentially pathogenic fungi and particles via aerosols from poultry units to the environment, which may post a considerable risk to public health and contribute to environmental pollution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indoor air quality recently entered legislation in Portugal. Several parameters must be evaluated and kept within limits in order to obtain a certification for air quality and energy consumption. Certification parameters were analyzed in two Portuguese archives in order to assess indoor air quality both for people attending or working on these premises and for maintenance of a written heritage that must be retained for future generations. Carbon monoxide (CO) and carbon dioxide (CO2), formaldehyde, and fungal counts were kept within stipulated limits. Relative humidity (RH), volatile organic compounds (VOC), particulate matter (PM10), and ozone (O3) showed values above legislated levels and justified the implementation of corrective measures. In terms of conservation, studies on the limit values are still needed, but according to the available international guidelines, some of the analyzed parameters such as PM10, O3, and RH were also above desirable values. Corrective measures were proposed to these institutions. Although this study was only of a short duration, it proved valuable in assessing potential eventual problems and constitutes the first Portuguese indoor air quality assessment taking into consideration both aspects of an archive such as human health and heritage safekeeping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indoor localization systems in nowadays is a huge area of interest not only at academic but also at industry and commercial level. The correct location in these systems is strongly influenced by antennas performance which can provide several gains, bandwidths, polarizations and radiation patterns, due to large variety of antennas types and formats. This paper presents the design, manufacture and measurement of a compact microstrip antenna, for a 2.4 GHZ frequency band, enhanced with the use of Electromagnetic Band-Gap (EBG) structures, which improve the electromagnetic behavior of the conventional antennas. The microstrip antenna with an EBG structure integrated allows an improvement of the location system performance in about 25% to 30% relatively to a conventional microstrip antenna.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives - To share with delegates the international experience in several Program of Physiotherapy course from Escola Superior de Tecnologia da Saúde de Lisboa (ESTeSL).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A voltage limiter circuit for indoor light energy harvesting applications is presented. This circuit is a part of a bigger system, whose function is to harvest indoor light energy, process it and store it, so that it can be used at a later time. This processing consists on maximum power point tracking (MPPT) and stepping-up, of the voltage from the photovoltaic (PV) harvester cell. The circuit here described, ensures that even under strong illumination, the generated voltage will not exceed the limit allowed by the technology, avoiding the degradation, or destruction, of the integrated die. A prototype of the limiter circuit was designed in a 130 nm CMOS technology. The layout of the circuit has a total area of 23414 mu m(2). Simulation results, using Spectre, are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A start-up circuit, used in a micro-power indoor light energy harvesting system, is described. This start-up circuit achieves two goals: first, to produce a reset signal, power-on-reset (POR), for the energy harvesting system, and secondly, to temporarily shunt the output of the photovoltaic (PV) cells, to the output node of the system, which is connected to a capacitor. This capacitor is charged to a suitable value, so that a voltage step-up converter starts operating, thus increasing the output voltage to a larger value than the one provided by the PV cells. A prototype of the circuit was manufactured in a 130 nm CMOS technology, occupying an area of only 0.019 mm(2). Experimental results demonstrate the correct operation of the circuit, being able to correctly start-up the system, even when having an input as low as 390 mV using, in this case, an estimated energy of only 5.3 pJ to produce the start-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epidemiological studies showed increased prevalence of respiratory symptoms and adverse changes in pulmonary function parameters in poultry workers, corroborating the increased exposure to risk factors, such as fungal load and their metabolites. This study aimed to determine the occupational exposure threat due to fungal contamination caused by the toxigenic isolates belonging to the complex of the species of Aspergillus flavus and also isolates fromAspergillus fumigatus species complex. The study was carried out in seven Portuguese poultries, using cultural and molecularmethodologies. For conventional/cultural methods, air, surfaces, and litter samples were collected by impaction method using the Millipore Air Sampler. For the molecular analysis, air samples were collected by impinger method using the Coriolis μ air sampler. After DNA extraction, samples were analyzed by real-time PCR using specific primers and probes for toxigenic strains of the Aspergillus flavus complex and for detection of isolates from Aspergillus fumigatus complex. Through conventional methods, and among the Aspergillus genus, different prevalences were detected regarding the presence of Aspergillus flavus and Aspergillus fumigatus species complexes, namely: 74.5 versus 1.0% in the air samples, 24.0 versus 16.0% in the surfaces, 0 versus 32.6% in new litter, and 9.9 versus 15.9%in used litter. Through molecular biology, we were able to detect the presence of aflatoxigenic strains in pavilions in which Aspergillus flavus did not grow in culture. Aspergillus fumigatus was only found in one indoor air sample by conventional methods. Using molecular methodologies, however, Aspergillus fumigatus complex was detected in seven indoor samples from three different poultry units. The characterization of fungal contamination caused by Aspergillus flavus and Aspergillus fumigatus raises the concern of occupational threat not only due to the detected fungal load but also because of the toxigenic potential of these species.