7 resultados para fly

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The basic objective of this work is to evaluate the durability of self-compacting concrete (SCC) produced in binary and ternary mixes using fly ash (FA) and limestone filler (LF) as partial replacement of cement. The main characteristics that set SCC apart from conventional concrete (fundamentally its fresh state behaviour) essentially depend on the greater or lesser content of various constituents, namely: greater mortar volume (more ultrafine material in the form of cement and mineral additions); proper control of the maximum size of the coarse aggregate; use of admixtures such as superplasticizers. Significant amounts of mineral additions are thus incorporated to partially replace cement, in order to improve the workability of the concrete. These mineral additions necessarily affect the concrete's microstructure and its durability. Therefore, notwithstanding the many well-documented and acknowledged advantages of SCC, a better understanding its behaviour is still required, in particular when its composition includes significant amounts of mineral additions. An ambitious working plan was devised: first, the SCC's microstructure was studied and characterized and afterwards the main transport and degradation mechanisms of the SCC produced were studied and characterized by means of SEM image analysis, chloride migration, electrical resistivity, and carbonation tests. It was then possible to draw conclusions about the SCC's durability. The properties studied are strongly affected by the type and content of the additions. Also, the use of ternary mixes proved to be extremely favourable, confirming the expected beneficial effect of the synergy between LF and FA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Stereopsis is the perception of depth based on retinal disparity. Global stereopsis depends on the process of random dot stimuli and local stereopsis depends on contour perception. The aim of this study was to correlate 3 stereopsis tests: TNO®, StereoTA B®, and Fly Stereo Acuity Test® and to study the sensitivity and correlation between them, using TNO® as the gold standard. Other variables as near convergence point, vergences, symptoms and optical correction were correlated with the 3 tests. Materials and Methods: Forty-nine students from Escola Superior de Tecnologia da Saúde de Lisboa (ESTeSL), aged 18-26 years old were included. Results: The stereopsis mean (standard-deviation-SD) values in each test were: TNO® = 87.04” ±84.09”; FlyTest® = 38.18” ±34.59”; StereoTA B® = 124.89’’ ±137.38’’. About the coefficient of determination: TNO® and StereoTA B® with R2 = 0.6 e TNO® and FlyTest® with R2 =0.2. Pearson correlation coefficient shows a positive correlation between TNO® and StereoTA B® (r = 0.784 with α = 0.01). Phi coefficient shows a strong and positive association between TNO® and StereoTA B® (Φ = 0.848 with α = 0.01). In the ROC Curve, the StereoTA B® has an area under the curve bigger than the FlyTest® with a sensivity of 92.3% for 94.4% of specificity, so it means that the test is sensitive with a good discriminative power. Conclusion: We conclude that the use of Stereopsis tests to study global Stereopsis are an asset for clinical use. This type of test is more sensitive, revealing changes in Stereopsis when it is actually changed, unlike the test Stereopsis, which often indicates normal Stereopsis, camouflaging a Stereopsis change. We noted also that the StereoTA B ® is very sensitive and despite being a digital application, possessed good correlation with the TNO®.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estereopsia define-se como a perceção de profundidade baseada na disparidade retiniana. A estereopsia global depende do processamento de estímulos de pontos aleatórios e a estereopsia local depende da perceção de contornos. O objetivo deste estudo é correlacionar três testes de estereopsia: TNO®, StereoTAB® e Fly Stereo Acuity Test® e verificar a sensibilidade e correlação entre eles, tendo o TNO® como gold standard. Incluíram-se 49 estudantes da Escola Superior de Tecnologia da Saúde de Lisboa (ESTeSL) entre os 18 e 26 anos. As variáveis ponto próximo de convergência (ppc), vergências, sintomatologia e correção ótica foram correlacionadas com os três testes. Os valores médios (desvios-padrão) de estereopsia foram: TNO® = 87,04’’ ±84,09’’; FlyTest® = 38,18’’ ±34,59’’; StereoTAB® = 124,89’’ ±137,38’’. Coeficiente de determinação: TNO® e StereoTAB® com R2=0,6 e TNO® e FlyTest® com R2=0,2. O coeficiente de correlação de Pearson mostra uma correlação positiva de entre o TNO® e o StereoTAB® (r=0,784 com α=0,01). O coeficiente de associação de Phi mostrou uma relação positiva forte entre o TNO® e StereoTAB® (Φ=0,848 com α=0,01). Na curva ROC, o StereoTAB® possui uma área sob a curva maior que o FlyTest®, apresentando valor de sensibilidade de 92,3% para uma especificidade de 94,4%, tornando-o num teste sensível e com bom poder discriminativo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho de Projecto de natureza científica para obtenção do grau de Mestre em Engenharia Civil

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de natureza Científica para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em Edificações

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho de Projeto submetido à Escola Superior de Teatro e Cinema para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Teatro - especialização em Teatro e Comunidade.