19 resultados para consecutive
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
This paper describes experimental work done towards the search for more profitable and sustainable alternatives regarding biodiesel production, using heterogeneous catalysts instead of the conventional homogenous alkaline catalysts, such as NaOH, KOH or sodium methoxide, for the methanolysis reaction. This experimental work is a first stage on the development and optimization of new solid catalysts, able to produce biodiesel from vegetable oils. The heterogeneous catalytic process has many differences from the currently used in industry homogeneous process. The main advantage is that, it requires lower investment costs, since no need for separation steps of methanol/catalyst, biodiesel/catalyst and glycerine/catalyst. This work resulted in the selection of CaO and CaO modified with Li catalysts, which showed very good catalytic performances with high activity and stability. In fact FAME yields higher than 92% were observed in two consecutive reaction batches without expensive intermediate reactivation procedures. Therefore, those catalysts appear to be suitable for biodiesel production.
Resumo:
Vários estudos demonstraram que os doentes com insuficiência cardíaca congestiva (ICC) têm um compromisso da qualidade de vida relacionada com a saúde (QVRS), tendo esta, nos últimos anos, vindo a tornar-se um endpoint primário quando se analisa o impacto do tratamento de situações crónicas como a ICC. Objectivos: Avaliar as propriedades psicométricas da versão portuguesa de um novo instrumento específico para medir a QVRS na ICC em doentes hospitalizados: o Kansas City Cardiomyopathy Questionnaire (KCCQ). População e Métodos: O KCCQ foi aplicado a uma amostra consecutiva de 193 doentes internados por ICC. Destes, 105 repetiram esta avaliação 3 meses após admissão hospitalar, não havendo eventos ocorridos durante este período de tempo. A idade era 64,4± 12,4 anos (entre 21 e 88), com 72,5% a pertencer ao sexo masculino, sendo a ICC de etiologia isquémica em 42%. Resultados: Esta versão do KCCQ foi sujeita a validação estatística semelhante à americana com a avaliação da fidelidade e validade. A fidelidade foi avaliada pela consistência interna dos domínios e dos somatórios, apresentando valores Alpha de Cronbach idênticos nos vários domínios e somatórios ( =0,50 a =0,94). A validade foi analisada pela convergência, pela sensibilidade às diferenças entre grupos e pela sensibilidade à alteração da condição clínica. Avaliou-se a validade convergente de todos os domínios relacionados com funcionalidade, pela relação verificada entre estes e uma medida de funcionalidade, a classificação da New York Heart Association (NYHA), tendo-se verificado correlações significativas (p<0,01), como medida para avaliar a funcionalidade em doentes com ICC. Efectuou-se uma análise de variância entre o domínio limitação física, os somatórios e as classes da NYHA, tendo-se encontrado diferenças estatisticamente significativas (F=23,4; F=36,4; F=37,4; p=0,0001), na capacidade de descriminação da gravidade da condição clínica. Foi realizada uma segunda avaliação em 105 doentes na consulta do 3º mês após a intervenção clínica, tendo-se observado alterações significativas nas médias dos domínios avaliados entre o internamento e a consulta (diferenças de 14,9 a 30,6 numa escala de 0-100), indicando que os domínios avaliados são sensíveis à mudança da condição clínica. A correlação interdimensões da qualidade de vida que compõe este instrumento é moderada, sugerindo dimensões independentes, apoiando a sua estrutura multifactorial e a adequabilidade desta medida para a sua avaliação. Conclusão: O KCCQ é um instrumento válido, sensível à mudança e específico para medir a QVRS numa população portuguesa com miocardiopatia dilatada e ICC. ABSTRACT - Several studies have shown that patients with congestive heart failure (CHF) have a compromised health-related quality of life (HRQL), and this, in recent years, has become a primary endpoint when considering the impact of treatment of chronic conditions such as CHF. Objectives: To evaluate the psychometric properties of the Portuguese version of a new specific instrument to measure HRQL in patients hospitalized for CHF: the Kansas City Cardiomyopathy Questionnaire (KCCQ). Methods: The KCCQ was applied to a sample of 193 consecutive patients hospitalized for CHF. Of these, 105 repeated the assessment 3 months after admission, with no events during this period. Mean age was 64.4±12.4 years (21-88), and 72.5% were 72.5% male. CHF was of ischemic etiology in 42% of cases. Results: This version of the KCCQ was subjected to statistical validation, with assessment of reliability and validity, similar to the American version. Reliability was assessed by the internal consistency of the domains and summary scores, which showed similar values of Cronbach alpha (0.50-0.94). Validity was assessed by convergence, sensitivity to differences between groups and sensitivity to changes in clinical condition. We evaluated the convergent validity of all domains related to functionality, through the relationship between them and a measure of functionality, the New York Heart Association (NYHA) classification. Significant correlations were found (p<0.01) for this measure of functionality in patients with CHF. Analysis of variance between the physical limitation domain, the summary scores and NYHA class was performed and statistically significant differences were found (F=23.4; F=36.4; F=37.4, p=0.0001) in the ability to discriminate severity of clinical condition. A second evaluation was performed on 105 patients at the 3-month follow-up outpatient appointment, and significant changes were observed in the mean scores of the domains assessed between hospital admission and the clinic appointment (differences from 14.9 to 30.6 on a scale of 0-100), indicating that the domains assessed are sensitive to changes in clinical condition. The correlation between dimensions of quality of life in the KCCQ is moderate, suggesting that the dimensions are independent, supporting the multifactorial nature of HRQL and the suitability of this measure for its evaluation. Conclusion: The KCCQ is a valid instrument, sensitive to change and a specific measure of HRQL in a population with dilated cardiomyopathy and CHF.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Intervenção Cardiovascular.
Resumo:
Introdução – Avaliar a força de preensão mostrou ser de primordial importância pela sua relação com a capacidade funcional dos indivíduos, permitindo determinar níveis de risco para incapacidade futura e, assim, estabelecer estratégias de prevenção. Grande parte dos estudos utiliza o dinamómetro hidráulico JAMAR que fornece o valor da força isométrica obtida durante a execução do movimento de preensão palmar. Contudo, existem outros dinamómetros disponíveis, como é o caso do dinamómetro portátil computorizado E‑Link (Biometrics) que fornece o valor da força máxima (peak force), para além de outras variáveis, como a taxa de fadiga. Não existem, contudo, estudos que nos permitam aceitar e comparar ou não os valores obtidos com os dois equipamentos e porventura utilizá‑los indistintamente. Objetivos – Avaliar a concordância entre as medições da força de preensão (força máxima ou peak force em Kg) obtida a partir de dois equipamentos diferentes (dinamómetros portáteis): um computorizado (E‑Link, Biometrics) e outro hidráulico (JAMAR). Metodologia – Foram avaliados 29 indivíduos (13H; 16M; 22±7 anos; 23,2±3,3 kg/m2) em 2 dias consecutivos, na mesma altura do dia. A posição de teste escolhida foi a recomendada pela Associação Americana de Terapeutas Ocupacionais e foi escolhido o melhor resultado de entre 3 tentativas para a mão dominante. Realizou‑se uma análise correlacional entre os valores obtidos na variável analisada em cada equipamento (coeficiente de Spearman) e uma análise de Bland & Altman para verificar a concordância entre as duas medições. Resultados – O coeficiente de correlação entre as duas medições foi elevado (rS= 0,956; p<0,001) e, pela análise de Bland & Altman, os valores obtidos encontram‑se todos dentro do intervalo da média±2SD. Conclusões – As duas medições mostraram ser concordantes, revelando que os dinamómetros testados podem ser comparáveis ou utilizados indistintamente em diferentes estudos e populações. ABSTRACT: Introduction – Assess grip strength has proved to be of vital importance because of its relationship with functional capacity of individuals, in order to determine levels of risk for future disability and thereby establish prevention strategies. Most studies use the JAMAR Hydraulic dynamometer that provides the value of isometric force obtained during the performance of grip movement. However, there are other dynamometers available, such as portable computerized dynamometer E‑Link (Biometrics), which provides the value of maximum force (peak force) in addition to other variables as the rate of fatigue. There are no studies that allow us to accept or not and compare values obtained with both devices and perhaps use them interchangeably. Purpose – To evaluate the agreement between the measurements of grip strength (peak force or maximum force in kg) obtained from two different devices (portable dynamometers): a computerized (E‑Link, Biometrics) and a hydraulic (JAMAR). Methodology – 29 subjects (13H, 16M, 22 ± 7 years, 23.2 ± 3.3 kg/m2) were assessed on two consecutive days at the same time of day. The test position chosen was recommended by the American Association of Occupational Therapists and was considered the best result from three attempts for the dominant hand. A correlation was studied between values obtained in the variable analyzed in each equipment (Spearman coefficient) and Bland‑Altman analysis to assess the agreement between the two measurements. Results – The correlation coefficient between the two measurements was high (rs = 0,956, p <0,001) and Bland & Altman analysis of the values obtained are all within the range of mean±2SD. Conclusions – The two measurements were shown to be concordant, revealing that the tested dynamometers can be comparable or used interchangeably in different studies and populations.
Resumo:
Introdução – Na avaliação diagnóstica em mamografia, o desempenho do radiologista pode estar sujeito a erros de diagnóstico. Objetivo – Descrever a importância da perceção visual na análise da mamografia, identificando os principais fatores que contribuem para a perceção visual do radiologista e que condicionam a acuidade diagnóstica. Metodologia – Estudo descritivo baseado numa revisão sistemática de literatura através da PubMed e da Science Direct. Foram incluídos 42 artigos que respeitavam, pelo menos, um dos critérios de inclusão no estudo. Para a seleção das referências foi utilizada a metodologia PRISMA, constituída por 4 fases: identificação, seleção preliminar, elegibilidade e estudos incluídos. Resultados – Na avaliação diagnóstica em mamografia, a perceção visual está intimamente relacionada com: 1) diferentes parâmetros visuais e da motilidade ocular (acuidade visual, sensibilidade ao contraste e à luminância e movimentos oculares); 2) com condições de visualização de uma imagem (iluminância da sala e luminância do monitor); e 3) fadiga ocular provocada pela observação diária consecutiva de imagens. Conclusões – A perceção visual pode ser influenciada por 3 categorias de erros observados: erros de pesquisa (lesões não são fixadas pela fóvea), erros de reconhecimento (lesões fixadas, mas não durante o tempo suficiente) e erros de decisão (lesões fixadas, mas não identificadas como suspeitas). Os estudos analisados sobre perceção visual, atenção visual e estratégia visual, bem como os estudos sobre condições de visualização não caracterizam a função visual dos observadores. Para uma avaliação correta da perceção visual em mamografia deverão ser efetuados estudos que correlacionem a função visual com a qualidade diagnóstica. ABSTRACT - Introduction – Diagnostic evaluation in mammography could be influenced by the radiologist performance that could be under diagnostic errors. Aims – To describe the importance of radiologist visual perception in mammographic diagnostic evaluation and to identify the main factors that contribute to diagnostic accuracy. Methods – In this systematic review 42 references were included based on inclusion criteria (PubMed and Science Direct). PRISMA method was used to select the references following 4 steps: identification, screening, eligibility and included references. Results – Visual perception in mammography diagnostic evaluation is related with: 1) visual parameters and ocular motility (visual acuity, contrast sensitivity and luminance and ocular movements); 2) image visualization environment (room iluminance and monitor luminance); and 3) eyestrain caused by image daily consecutive observation. Conclusions – Visual perception can be influenced by three errors categories: search errors (lesions are never looked at with high-resolution foveal vision), recognition errors (lesions are looked at, but not long enough to detect or recognize) and decision errors (lesions are looked at for long periods of time but are still missed). The reviewed studies concerning visual perception, visual attention, visual strategies and image visualization environment do not describe observer’s visual function. An accurate evaluation of visual perception in mammography must include visual function analysis.
Resumo:
A copper C(2)-symmetric bis(oxazoline), CuBox, was introduced in two forms of commercial Y zeolite: a sodium form (NaY) and an ultrastable form (NaUSY). CuBox was introduced by first partially exchanging the sodium cations of both zeolites for copper and then by refluxing the obtained materials with a solution of bis(oxazoline) (Box). Two different loadings were prepared for each form of zeolite. The materials were characterized by copper ICP-AES, elemental analysis, XPS, FTIR, TG, and nitrogen adsorption isotherms at -196 degrees C. Evidence for Box ligand location in the supercages of NaY and NaUSY zeolites and its coordination to the exchanged copper(II) was obtained by the several techniques used. The materials were all active in the cyclopropanation of styrene with ethyldiazoacetate at room temperature and diastereoselective toward trans cydopropanes. Although the materials containing Box showed low enantioselectivities, their catalytic activities were higher than the parent copper exchanged zeolites, and did not decrease with reuse, at least during three consecutive cycles.
Resumo:
Introduction and Objectives - Paraoxonases may exert anti-atherogenic action by reducing lipid peroxidation. Previous studies examined associations between polymorphisms in the paraoxonase 1 (PON1) gene and development of coronary artery disease (CAD), with inconsistent results. Given the similarities in clinical and pathophysiological risk factors of CAD and calcific aortic valve stenosis (CAVS), we postulated a link between PON1 alleles and CAVS progression. Methods - We investigated the association between PON1 55 and 192 single nucleotide polymorphisms (SNPs), their enzyme activity, and CAVS progression assessed by aortic valve area and transvalvular peak velocity in 67 consecutive patients with moderate CAVS and 251 healthy controls. Results - PON1 paraoxonase activity was higher in CAVS patients (P<0.001). The PON1 genotype Q192R SNP (P=0.03) and variant allele (R192) (P=0.01) frequencies differed between CAVS patients and controls. Significant association existed between PON1 enzyme activity, phenotypic effects of PON1 192 genotype polymorphisms, and CAVS progression, but not between PON1 55 and high-density lipoprotein (P=0.44) or low-density lipoprotein cholesterol (P=0.12), between 192 genotype and high-density lipoprotein (P=0.24) or low-density lipoprotein cholesterol (P=0.52). Conclusion - The PON1 genotype Q192R SNP has an important effect on CAVS disease progression. This study helps outline a genotype-phenotype relationship for PON1 in this unique population.
Resumo:
Dissertação apresentada à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Educação Artística, na especialização de Teatro na Educação
Resumo:
Relatório Final de Estágio apresentado à Escola Superior de Dança, com vista à obtenção do grau de Mestre em Ensino de Dança.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Intervenção Cardiovascular
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Informática e de Computadores
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Ultrassonografia Cardiovascular
Resumo:
Mestrado em Radioterapia
Resumo:
Trabalho de Projecto submetida(o) à Escola Superior de Teatro e Cinema para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Teatro - especialização em Artes Performativas - Interpretação
Resumo:
Introdução – A cintigrafia de perfusão do miocárdio (CPM) desempenha um importante papel no diagnóstico, avaliação e seguimento de pacientes com doença arterial coronária, sendo o seu processamento realizado maioritariamente de forma semiautomática. Uma vez que o desempenho dos técnicos de medicina nuclear (TMN) pode ser afetado por fatores individuais e ambientais, diferentes profissionais que processem os mesmos dados poderão obter diferentes estimativas dos parâmetros quantitativos (PQ). Objetivo – Avaliar a influência da experiência profissional e da função visual no processamento semiautomático da CPM. Analisar a variabilidade intra e interoperador na determinação dos PQ funcionais e de perfusão. Metodologia – Selecionou-se uma amostra de 20 TMN divididos em dois grupos, de acordo com a sua experiência no software Quantitative Gated SPECTTM: Grupo A (GA) – TMN ≥600h de experiência e Grupo B (GB) – TMN sem experiência. Submeteram-se os TMN a uma avaliação ortóptica e ao processamento de 21 CPM, cinco vezes, não consecutivas. Considerou-se uma visão alterada quando pelo menos um parâmetro da função visual se encontrava anormal. Para avaliar a repetibilidade e a reprodutibilidade recorreu-se à determinação dos coeficientes de variação, %. Na comparação dos PQ entre operadores, e para a análise do desempenho entre o GA e GB, aplicou-se o Teste de Friedman e de Wilcoxon, respetivamente, considerando o processamento das mesmas CPM. Para a comparação de TMN com visão normal e alterada na determinação dos PQ utilizou-se o Teste Mann-Whitney e para avaliar a influência da visão para cada PQ recorreu-se ao coeficiente de associação ETA. Diferenças estatisticamente significativas foram assumidas ao nível de significância de 5%. Resultados e Discussão – Verificou-se uma reduzida variabilidade intra (<6,59%) e inter (<5,07%) operador. O GB demonstrou ser o mais discrepante na determinação dos PQ, sendo a parede septal (PS) o único PQ que apresentou diferenças estatisticamente significativas (zw=-2,051, p=0,040), em detrimento do GA. No que se refere à influência da função visual foram detetadas diferenças estatisticamente significativas apenas na fração de ejeção do ventrículo esquerdo (FEVE) (U=11,5, p=0,012) entre TMN com visão normal e alterada, contribuindo a visão em 33,99% para a sua variação. Denotaram-se mais diferenças nos PQ obtidos em TMN que apresentam uma maior incidência de sintomatologia ocular e uma visão binocular diminuída. A FEVE demonstrou ser o parâmetro mais consistente entre operadores (1,86%). Conclusão – A CPM apresenta-se como uma técnica repetível e reprodutível, independente do operador. Verificou-se influência da experiência profissional e da função visual no processamento semiautomático da CPM, nos PQ PS e FEVE, respetivamente.