23 resultados para computer assisted emission tomography

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Brain dopamine transporters imaging by Single Emission Tomography (SPECT) with 123I-FP-CIT (DaTScanTM) has become an important tool in the diagnosis and evaluation of Parkinson syndromes.This diagnostic method allows the visualization of a portion of the striatum – where healthy pattern resemble two symmetric commas - allowing the evaluation of dopamine presynaptic system, in which dopamine transporters are responsible for dopamine release into the synaptic cleft, and their reabsorption into the nigrostriatal nerve terminals, in order to be stored or degraded. In daily practice for assessment of DaTScan TM, it is common to rely only on visual assessment for diagnosis. However, this process is complex and subjective as it depends on the observer’s experience and it is associated with high variability intra and inter observer. Studies have shown that semiquantification can improve the diagnosis of Parkinson syndromes. For semiquantification, analysis methods of image segmentation using regions of interest (ROI) are necessary. ROIs are drawn, in specific - striatum - and in nonspecific – background – uptake areas. Subsequently, specific binding ratios are calculated. Low adherence of semiquantification for diagnosis of Parkinson syndromes is related, not only with the associated time spent, but also with the need of an adapted database of reference values for the population concerned, as well as, the examination of each service protocol. Studies have concluded, that this process increases the reproducibility of semiquantification. The aim of this investigation was to create and validate a database of healthy controls for Dopamine transporters with DaTScanTM named DBRV. The created database has been adapted to the Nuclear Medicine Department’s protocol, and the population of Infanta Cristina’s Hospital located in Badajoz, Spain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). Methods: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. Results: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. Conclusion: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Incidental findings on low-dose CT images obtained during hybrid imaging are an increasing phenomenon as CT technology advances. Understanding the diagnostic value of incidental findings along with the technical limitations is important when reporting image results and recommending follow-up, which may result in an additional radiation dose from further diagnostic imaging and an increase in patient anxiety. This study assessed lesions incidentally detected on CT images acquired for attenuation correction on two SPECT/CT systems. Methods: An anthropomorphic chest phantom containing simulated lesions of varying size and density was imaged on an Infinia Hawkeye 4 and a Symbia T6 using the low-dose CT settings applied for attenuation correction acquisitions in myocardial perfusion imaging. Twenty-two interpreters assessed 46 images from each SPECT/CT system (15 normal images and 31 abnormal images; 41 lesions). Data were evaluated using a jackknife alternative free-response receiver-operating-characteristic analysis (JAFROC). Results: JAFROC analysis showed a significant difference (P < 0.0001) in lesion detection, with the figures of merit being 0.599 (95% confidence interval, 0.568, 0.631) and 0.810 (95% confidence interval, 0.781, 0.839) for the Infinia Hawkeye 4 and Symbia T6, respectively. Lesion detection on the Infinia Hawkeye 4 was generally limited to larger, higher-density lesions. The Symbia T6 allowed improved detection rates for midsized lesions and some lower-density lesions. However, interpreters struggled to detect small (5 mm) lesions on both image sets, irrespective of density. Conclusion: Lesion detection is more reliable on low-dose CT images from the Symbia T6 than from the Infinia Hawkeye 4. This phantom-based study gives an indication of potential lesion detection in the clinical context as shown by two commonly used SPECT/CT systems, which may assist the clinician in determining whether further diagnostic imaging is justified.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Os linfomas são tumores estabelecidos a nível do sistema linfático. Devido à sua heterogeneidade classificam-se como Linfoma Hodgkin (LH) e Linfoma não Hodgkin (LNH), apresentando diferente prognóstico e seguimento quimioterapêutico. Actualmente, a Photon Emission Tomography/Computed Tomography (PET/CT, do acrónimo inglês) é considerada “imagem” de excelência no estudo desta patologia. Neste contexto, é objectivo deste artigo verificar a utilidade da técnica PET/CT e correlacionar o valor de Standard Uptake Value (SUV), obtido pela PET, com o estadio histológico do linfoma e com a resposta ao tratamento quimioterapêutico. Metodologia - Analisaram-se retrospectivamente 356 estudos respeitantes a 231 pacientes, aos quais se realizou uma PET/CT para estadiamento, estudo de massa ou avaliação da resposta ao tratamento. Após a administração de uma actividade média de 18F-FDG de 288,6 MBq, foram adquiridas imagens numa PET/CT GE Discovery ST. Os resultados obtidos foram comparados com os dados clínicos dos pacientes. Resultados - Foram encontradas diferenças significativas entre a idade Vs tipo de linfoma. Não foram encontradas diferenças significativas entre: valor de SUVmáx ganglionar, lesões extra-ganglionares e seu valor de SUV relativamente ao tipo de linfoma. Comprovou-se a influência da PET/CT na alteração do estadio do linfoma e atitude terapêutica. Em última análise, obtiveram-se respectivamente os seguintes valores de sensibilidade, especificidade e exactidão: 98%, 79% e 88%. Conclusões - Os resultados obtidos permitem verificar a importância da imagem PET/CT no estadiamento, monitorização e alteração da atitude terapêutica dos LH e LNH.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introdução – O cancro de pulmão/traqueia e brônquios é a principal causa de morte por neoplasia na União Europeia. A técnica de duas aquisições de imagem em tempos diferentes no Positron Emission Tomography/Computed Tomography (PET/CT) tem sido referenciada em alguns artigos como uma mais-valia no diagnóstico do cancro do pulmão. O objectivo deste estudo consiste em avaliar a eficiência diagnóstica do PET/CT com a aquisição das duas imagens em tempos diferentes na caracterização do nódulo solitário pulmonar (NSP), tendo em conta a histologia e o tamanho do nódulo. Metodologia – Foram analisados 115 NSP, num total de 110 pacientes, dos quais 65 nódulos eram malignos. Adquiriram-se duas imagens, a primeira a um tempo médio de 52 minutos e a segunda a um tempo médio de 125 minutos após administração do 18F-2-fluoro-2-deoxi-D-glucose (18F-FDG). Para a análise das imagens obteve-se o standard uptake value máximo (SUVmax) e a percentagem de variação dos SUVmax (%variação). Resultados – A %variação apresenta valores de eficiência diagnóstica superiores à análise dos SUVmax em separado. Existem também diferenças significativas na histologia e no SUVmax, registando-se um aumento do SUVmax2 comparativamente ao SUVmax1 nas patologias malignas. Conclusão – A técnica da aquisição de duas imagens em tempos diferentes mostrou ser mais eficaz na caracterização do NSP do que a análise de apenas uma imagem.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introdução – O cancro de mama é a principal causa de morte por cancro na população feminina portuguesa. Assim, pretende-se descrever sucintamente o percurso de uma paciente com tumor de mama, evidenciando a interligação entre algumas áreas das tecnologias da saúde. Metodologia – Selecionou-se um caso clínico de uma paciente com cancro de mama e recorreu-se à pesquisa bibliográfica de forma a apoiar ou refutar os resultados obtidos com o referido caso clínico. Resultados e discussão de resultados – Em 1996 foi diagnosticado à paciente um carcinoma ductal da mama esquerda e posteriormente, em 2011, foi diagnosticada uma metástase do carcinoma mamário com padrão mucinoso. Neste caso, bem como em todos os tumores de mama, foi realizada uma abordagem multidisciplinar envolvendo diferentes áreas das tecnologias da saúde. Para deteção e diagnóstico do cancro de mama são utilizadas a mamografia e a ultrassonografia. Para casos de re-estadiamento e monitorização da terapêutica devem ser utilizadas a tomografia por emissão de positrões (TEP) e a ressonância magnética mamária. No que se refere à terapêutica, neste tipo de tumores recorre-se à cirurgia, à radioterapia e à quimioterapia. ABSTRACT - Introduction – The breast cancer is the main cause of death by cancer in the Portuguese female population. We intend to describe briefly the pathway of a patient with breast cancer, highlighting the connection between some of the health technology areas. Methodology – It was selected a clinical case of a patient with breast cancer and it was used a literature research to support or refute the results obtained with the mentioned clinical case. Results and discussion – In 1996, it was diagnosed to the patient a ductal carcinoma of the left breast and in 2011 it was diagnosed a breast metastases. In this case, as well as other breast tumours, it was done a multidisciplinary approach involving different areas of health technologies. For detection and diagnose of breast cancer it’s used the mammography and ultrasound. For cases of re-staging and treatment monitoring it should be used positron emission tomography and magnetic resonance imaging of the breast. Regarding the therapy approach, in this type of tumours, it is used surgery, radiotherapy and chemotherapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Myocardial Perfusion Gated Single Photon Emission Tomography (Gated-SPET) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV) function. But standard protocols of the Gated-SPECT studies require long acquisition times for each study. It is therefore important to reduce as much as possible the total duration of image acquisition. However, it is known that this reduction leads to decrease on counts statistics per projection and raises doubts about the validity of the functional parameters determined by Gated-SPECT. Considering that, it’s difficult to carry out this analysis in real patients. For ethical, logistical and economical matters, simulated studies could be required for this analysis. Objective: Evaluate the influence of the total number of counts acquired from myocardium, in the calculation of myocardial functional parameters (LVEF – left ventricular ejection fraction, EDV – end-diastolic volume, ESV – end-sistolic volume) using routine software procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neste trabalho aborda-se o desenvolvimento da carroçaria do Veículo Eléctrico Ecológico – VEECO recorrendo a tecnologias assistidas por computador. Devido à impossibilidade de abranger toda a temática das tecnologias assistidas por computador, associadas ao desenvolvimento de uma carroçaria automóvel, o foco deste trabalho assenta no processo de obtenção de um modelo digital válido e no estudo do desempenho aerodinâmico da carroçaria. A existência de um modelo digital válido é a base de qualquer processo de desenvolvimento associado a tecnologias assistidas por computador. Neste sentido, numa primeira etapa, foram aplicadas e desenvolvidas técnicas e metodologias que permitem o desenvolvimento de uma carroçaria desde a sua fase de “design” até à obtenção de um modelo digital CAD. Estas abrangem a conversão e importação de dados, a realização de engenharia inversa, a construção/reconstrução CAD em CATIA V5 e a preparação/correcção de modelos CAD para a análise numérica. Numa segunda etapa realizou-se o estudo da aerodinâmica exterior da carroçaria, recorrendo à ferramenta de análise computacional de fluidos (CFD) Flow Simulation da CosmosFloworks integrado no programa SolidWorks 2010. Associado à temática do estudo aerodinâmico e devido à elevada importância da validação dos resultados numéricos por meio de dados experimentais, foi realizado o estudo de análise dimensional que permite a realização de ensaios experimentais à escala, bem como a análise dos resultados experimentais obtidos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The formation of amyloid structures is a neuropathological feature that characterizes several neurodegenerative disorders, such as Alzheimer´s and Parkinson´s disease. Up to now, the definitive diagnosis of these diseases can only be accomplished by immunostaining of post mortem brain tissues with dyes such Thioflavin T and congo red. Aiming at early in vivo diagnosis of Alzheimer´s disease (AD), several amyloid-avid radioprobes have been developed for b-amyloid imaging by positron emission tomography (PET) and single-photon emission computed tomography (SPECT). The aim of this paper is to present a perspective of the available amyloid imaging agents, special those that have been selected for clinical trials and are at the different stages of the US Food and Drugs Administration (FDA) approval.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The most recent Varian® micro multileaf collimator(MLC), the High Definition (HD120) MLC, was modeled using the BEAMNRCMonte Carlo code. This model was incorporated into a Varian medical linear accelerator, for a 6 MV beam, in static and dynamic mode. The model was validated by comparing simulated profiles with measurements. Methods: The Varian® Trilogy® (2300C/D) accelerator model was accurately implemented using the state-of-the-art Monte Carlo simulation program BEAMNRC and validated against off-axis and depth dose profiles measured using ionization chambers, by adjusting the energy and the full width at half maximum (FWHM) of the initial electron beam. The HD120 MLC was modeled by developing a new BEAMNRC component module (CM), designated HDMLC, adapting the available DYNVMLC CM and incorporating the specific characteristics of this new micro MLC. The leaf dimensions were provided by the manufacturer. The geometry was visualized by tracing particles through the CM and recording their position when a leaf boundary is crossed. The leaf material density and abutting air gap between leaves were adjusted in order to obtain a good agreement between the simulated leakage profiles and EBT2 film measurements performed in a solid water phantom. To validate the HDMLC implementation, additional MLC static patterns were also simulated and compared to additional measurements. Furthermore, the ability to simulate dynamic MLC fields was implemented in the HDMLC CM. The simulation results of these fields were compared with EBT2 film measurements performed in a solid water phantom. Results: Overall, the discrepancies, with and without MLC, between the opened field simulations and the measurements using ionization chambers in a water phantom, for the off-axis profiles are below 2% and in depth-dose profiles are below 2% after the maximum dose depth and below 4% in the build-up region. On the conditions of these simulations, this tungsten-based MLC has a density of 18.7 g cm− 3 and an overall leakage of about 1.1 ± 0.03%. The discrepancies between the film measured and simulated closed and blocked fields are below 2% and 8%, respectively. Other measurements were performed for alternated leaf patterns and the agreement is satisfactory (to within 4%). The dynamic mode for this MLC was implemented and the discrepancies between film measurements and simulations are within 4%. Conclusions: The Varian® Trilogy® (2300 C/D) linear accelerator including the HD120 MLC was successfully modeled and simulated using the Monte CarloBEAMNRC code by developing an independent CM, the HDMLC CM, either in static and dynamic modes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chronic Liver Disease is a progressive, most of the time asymptomatic, and potentially fatal disease. In this paper, a semi-automatic procedure to stage this disease is proposed based on ultrasound liver images, clinical and laboratorial data. In the core of the algorithm two classifiers are used: a k nearest neighbor and a Support Vector Machine, with different kernels. The classifiers were trained with the proposed multi-modal feature set and the results obtained were compared with the laboratorial and clinical feature set. The results showed that using ultrasound based features, in association with laboratorial and clinical features, improve the classification accuracy. The support vector machine, polynomial kernel, outperformed the others classifiers in every class studied. For the Normal class we achieved 100% accuracy, for the chronic hepatitis with cirrhosis 73.08%, for compensated cirrhosis 59.26% and for decompensated cirrhosis 91.67%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, we present a neural network (NN) based method designed for 3D rigid-body registration of FMRI time series, which relies on a limited number of Fourier coefficients of the images to be aligned. These coefficients, which are comprised in a small cubic neighborhood located at the first octant of a 3D Fourier space (including the DC component), are then fed into six NN during the learning stage. Each NN yields the estimates of a registration parameter. The proposed method was assessed for 3D rigid-body transformations, using DC neighborhoods of different sizes. The mean absolute registration errors are of approximately 0.030 mm in translations and 0.030 deg in rotations, for the typical motion amplitudes encountered in FMRI studies. The construction of the training set and the learning stage are fast requiring, respectively, 90 s and 1 to 12 s, depending on the number of input and hidden units of the NN. We believe that NN-based approaches to the problem of FMRI registration can be of great interest in the future. For instance, NN relying on limited K-space data (possibly in navigation echoes) can be a valid solution to the problem of prospective (in frame) FMRI registration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear - Ramo de especialização: Tomografia por Emissão de Positrões

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Myocardial Perfusion Gated Single Photon Emission Tomography (Gated-SPET) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV). The purpose of this study is to evaluate the influence of the total number of counts acquired from myocardium, in the calculation of myocardial functional parameters using routine software procedures. Methods: Gated-SPET studies were simulated using Monte Carlo GATE package and NURBS phantom. Simulated data were reconstructed and processed using the commercial software package Quantitative Gated-SPECT. The Bland-Altman and Mann-Whitney-Wilcoxon tests were used to analyze the influence of the number of total counts in the calculation of LV myocardium functional parameters. Results: In studies simulated with 3MBq in the myocardium there were significant differences in the functional parameters: Left ventricular ejection fraction (LVEF), end-systolic volume (ESV), Motility and Thickness; between studies acquired with 15s/projection and 30s/projection. Simulations with 4.2MBq show significant differences in LVEF, end-diastolic volume (EDV) and Thickness. Meanwhile in the simulations with 5.4MBq and 8.4MBq the differences were statistically significant for Motility and Thickness. Conclusion: The total number of counts per simulation doesn't significantly interfere with the determination of Gated-SPET functional parameters using the administered average activity of 450MBq to 5.4MBq in myocardium.