9 resultados para bladder washing

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the influence of Everolimus (RAD001) on chemically induced urothelial lesions in mice and its influence on in vitro human bladder cancer cell lines. Methods: ICR male mice were given N-butyl-N-(4-hydroxybutyl) nitrosamine in drinking water for a period of 12 weeks. Subsequently, RAD001 was administered via oral gavage, for 6 weeks. At the end of the experiment, all the animals were sacrificed and tumor development was determined by means of histopathologic evaluation; mammalian target of rapamycin (mTOR) expressivity was evaluated by immunohistochemistry. Three human bladder cancer cell lines (T24, HT1376, and 5637) were treated using a range of RAD001 concentrations. MTT assay, terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL), and flow cytometry were used to assess cell proliferation, apoptosis index, and cell cycle analysis, respectively. Immunoblotting analysis of 3 cell line extracts using mTOR and Akt antibodies was performed in order to study the expression of Akt and mTOR proteins and their phosphorylated forms. Results: The incidence of urothelial lesions in animals treated with RAD001 was similar to those animals not treated. RAD001 did not block T24 and HT1376 cell proliferation or induce apoptosis. A reduction in cell proliferation rate and therefore G0/G1 phase arrest, as well as a statistically significant induction of apoptosis (P 0.001), was only observed in the 5637 cell line. Conclusion: RAD001 seems not to have a significant effect on chemically induced murine bladder tumors. The effect of RAD001 on tumor proliferation and apoptosis was achieved only in superficial derived bladder cancer cell line, no effect was observed in invasive cell lines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The cellblock is a technique that enables the pathologist to study the morphological detail of residual samples and can be used when it is necessary to perform additional diagnostic techniques. Objective: Demonstrate the processing of bronchial washings in liquid based cytology to cellblock using HistoGel in residual samples, evaluating the morphology and preservation of cytological material. Methods: There were used 40 residual samples from bronchial washings in liquid based cytology, after determination of the clinical diagnosis, being made subsequently 40 cellblocks using HistoGel. For each cellblock there was made one histological section for analysis of cell morphology, which was subsequently stained with the routine histological staining. After microscope observation, the morphology was evaluated by 3 experts in the field of pathology, based on the parameters: Cellularity, Preservation and Background. Results: The average final score of 3 evaluators, on a scale of 0 to 100, in assessing the morphology of the 40 samples was 55.6. From the 40 histological sections, 5 of them were considered not viable for evaluation. Conclusions: The results obtained indicate median quality maintenance of morphology. However, it is noted that in only 5 cases it was not possible to determine an evaluation, knowing from the outset that these are residual samples with a very scant cellularity. Thus, it is possible to say that the processing of bronchial washings to cellblock using HistoGel contributes to a concentration of the cytological material, allowing its evaluation and subsequent diagnosis. Additional diagnostic techniques are shown equally viable in these cellblocks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução – Numa era em que os tratamentos de Radioterapia Externa (RTE) exigem cada vez mais precisão, a utilização de imagem médica permitirá medir, quantificar e avaliar o impacto do erro provocado pela execução do tratamento ou pelos movimentos dos órgãos. Objetivo – Analisar os dados existentes na literatura acerca de desvios de posicionamento (DP) em patologias de cabeça e pescoço (CP) e próstata, medidos com Cone Beam Computed Tomography (CBCT) ou Electronic Portal Image Device (EPID). Metodologia – Para esta revisão da literatura foram pesquisados artigos recorrendo às bases de dados MEDLINE/PubMed e b-on. Foram incluídos artigos que reportassem DP em patologias CP e próstata medidos através de CBCT e EPID. Seguidamente foram aplicados critérios de validação, que permitiram a seleção dos estudos. Resultados – Após a análise de 35 artigos foram incluídos 13 estudos e validados 9 estudos. Para tumores CP, a média (μ) dos DP encontra-se entre 0,0 e 1,2mm, com um desvio padrão (σ) máximo de 1,3mm. Para patologias de próstata observa-se μDP compreendido entre 0,0 e 7,1mm, com σ máximo de 7,5mm. Discussão/Conclusão – Os DP em patologias CP são atribuídos, maioritariamente, aos efeitos secundários da RTE, como mucosite e dor, que afetam a deglutição e conduzem ao emagrecimento, contribuindo para a instabilidade da posição do doente durante o tratamento, aumentando as incertezas de posicionamento. Os movimentos da próstata devem-se principalmente às variações de preenchimento vesical, retal e gás intestinal. O desconhecimento dos DP afeta negativamente a precisão da RTE. É importante detetá-los e quantificá-los para calcular margens adequadas e a magnitude dos erros, aumentando a precisão da administração de RTE, incluindo o aumento da segurança do doente. - ABSTRACT - Background and Purpose – In an era where precision is an increasing necessity in external radiotherapy (RT), modern medical imaging techniques provide means for measuring, quantifying and evaluating the impact of treatment execution and movement error. The aim of this paper is to review the current literature on the quantification of setup deviations (SD) in patients with head and neck (H&N) or prostate tumors, using Cone Beam Computed Tomography (CBCT) or Electronic Portal Image Device (EPID). Methods – According to the study protocol, MEDLINE/PubMed and b-on databases were searched for trials, which were analyzed using selection criteria based on the quality of the articles. Results – After assessment of 35 papers, 13 studies were included in this analysis and nine were authenticated (6 for prostate and 3 for H&N tumors). The SD in the treatment of H&N cancer patients is in the interval of 0.1 to 1.2mm, whereas in prostate cancer this interval is 0.0 to 7.1mm. Discussion – The reproducibility of patient positioning is the biggest barrier for higher precision in RT, which is affected by geometrical uncertainty, positioning errors and inter or intra-fraction organ movement. There are random and systematic errors associated to patient positioning, introduced since the treatment planning phase or through physiological organ movement. Conclusion – The H&N SD are mostly assigned to the Radiotherapy adverse effects, like mucositis and pain, which affect swallowing and decrease secretions, contributing for the instability of patient positioning during RT treatment and increasing positioning uncertainties. Prostate motion is mainly related to the variation in bladder and rectal filling. Ignoring SD affects negatively the accuracy of RT. Therefore, detection and quantification of SD is crucial in order to calculate appropriate margins, the magnitude of error and to improve accuracy in RTE and patient safety.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente documento enquadra-se no âmbito do trabalho final do mestrado (TFM) do curso de Engenharia Civil, na área de especialização de Hidráulica, do Instituto Superior de Engenharia de Lisboa, sob a forma de um projeto na fase de estudo prévio com o título ―Gestão Sustentável da Água no empreendimento turístico Parque de Campismo da Ilha do Pessegueiro situado em Porto Covo - Região de Turismo do Alentejo‖. Este trabalho é constituído essencialmente por 5 partes. Sendo a primeira uma breve introdução às questões a abordar, a segunda corresponde à discrição teórica do uso eficiente da água baseando-se no PNEUA (Programa nacional para o uso eficiente da água). Já a terceira parte é relativa ao atual sistema de utilização da água no Parque de campismo da ilha do pessegueiro (PCIP), sendo a quarta o estudo do desenvolvimento do projecto para a gestão eficiente da água no empreendimento e a quinta parte o estudo de viabilidade económica e financeira a implementar no projecto. Para além da implementação de medidas de poupança são também objetivos principais deste trabalho a reutilização da água através da recolha, o tratamento e armazenamento das águas residuais e aproveitamento das águas pluviais para posterior abastecimento do sistema de utilização em descargas sanitárias, lavagem de pavimentos e regas de espaços verdes. São, portanto, três os subsistemas de gestão eficiente da água que se pretende implementar. Dá-se importância ao estudo de viabilidade económica do projeto, cujo período de retorno do capital investido em capitais próprios e alheios é de seis anos. Este projeto pretende dar apoio técnico ao uso eficiente da água no PCIP, de forma a conseguir por um lado obter vantagens económicas e por outro proteger o ambiente. As vantagens económicas são interessantes para orientar os recursos financeiros para outros investimentos e as questões ambientais são a base de uma campanha, já em curso, para obtenção de certificação energética, em conjunto com outras práticas já em curso, nomeadamente a recolha seletiva de resíduos sólidos para recircular e aproveitamento de energia solar.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às tecnologias da Saúde

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim - To use Monte Carlo (MC) together with voxel phantoms to analyze the tissue heterogeneity effect in the dose distributions and equivalent uniform dose (EUD) for (125)I prostate implants. Background - Dose distribution calculations in low dose-rate brachytherapy are based on the dose deposition around a single source in a water phantom. This formalism does not take into account tissue heterogeneities, interseed attenuation, or finite patient dimensions effects. Tissue composition is especially important due to the photoelectric effect. Materials and Methods - The computed tomographies (CT) of two patients with prostate cancer were used to create voxel phantoms for the MC simulations. An elemental composition and density were assigned to each structure. Densities of the prostate, vesicles, rectum and bladder were determined through the CT electronic densities of 100 patients. The same simulations were performed considering the same phantom as pure water. Results were compared via dose-volume histograms and EUD for the prostate and rectum. Results - The mean absorbed doses presented deviations of 3.3-4.0% for the prostate and of 2.3-4.9% for the rectum, when comparing calculations in water with calculations in the heterogeneous phantom. In the calculations in water, the prostate D 90 was overestimated by 2.8-3.9% and the rectum D 0.1cc resulted in dose differences of 6-8%. The EUD resulted in an overestimation of 3.5-3.7% for the prostate and of 7.7-8.3% for the rectum. Conclusions - The deposited dose was consistently overestimated for the simulation in water. In order to increase the accuracy in the determination of dose distributions, especially around the rectum, the introduction of the model-based algorithms is recommended.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Titanate nanotubes (TNT) with different sodium contents have been synthesised using a hydrothermal approach and a swift and highly controllable post-washing processes. The influence of the sodium/proton replacement on the structural and morphological characteristics of the prepared materials was analysed. Different optical behaviour was observed depending on the Na+/H+ samples’ content. A band gap energy of 3.27±0.03 eV was estimated for the material with higher sodium content while a value of 2.81±0.02 eV was inferred for the most protonated material, which therefore exhibits an absorption edge in the near visible region. The point of zero charge of the materials was determined and the influence of the sodium content on the adsorption of both cationic and anionic organic dyes was studied. The photocatalytic performance of the TNT samples was evaluated in the rhodamine 6G degradation process. Best photodegradation results were obtained when using the most protonated material as catalyst, although this material has shown the lowest R6G adsorption capability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho final de Mestrado para obtenção do grau de mestre em Engenharia Mecânica Ramo de Energia, Refrigeração e Climatização