11 resultados para barrier repair cost

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total particulate matter (TPM) was passively collected inside two classrooms of each of five elementary schools in Lisbon, Portugal. TPM was collected in polycarbonate filters with a 47 mm diameter, placed inside of uncovered plastic petri dishes. The sampling period was from 19 May to 22 June 2009 (35 days exposure) and the collected TPM masses varied between 0.2 mg and 0.8 mg. The major elements were Ca, Fe, Na, K, and Zn at μg level, while others were at ng level. Pearson′s correlation coefficients above 0.75 (a high degree of correlation) were found between several elements. Soil-related, traffic soil re-suspension and anthropogenic emission sources could be identified. Blackboard chalk was also identified through Ca large presence. Some of the determined chemical elements are potential carcinogenic. Quality control of the results showed good agreement as confirmed by the application of u-score test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As coberturas planas são um dos principais elementos construtivos de uma edificação, necessitando por isso de materiais com qualidade e certificados por organismos competentes, bem como de uma conceção e execução minuciosas. Em Portugal, os estudos sobre as anomalias realmente observadas em coberturas planas são ainda bastante reduzidos. Nesse âmbito, o presente trabalho teve como objetivo, efetuar o levantamento e a análise estatística das principais anomalias e causas identificadas em coberturas planas de 75 edifícios, permitindo assim a elaboração de um estudo que possa contribuir para a prevenção dessas anomalias e que indique também as medidas necessárias à reparação e os respetivos custos associados. As anomalias foram analisadas através da observação "in situ" das coberturas o que conduziu ao preenchimento de fichas de obra com os dados recolhidos. Da análise estatística efetuada aos edifícios, verificou-se que as principais anomalias detetadas estão relacionadas com perfurações e fissurações do sistema impermeabilizante, resultantes da falta de conhecimento dos utilizadores. Foi possível verificar erros de execução de remates em pontos singulares da cobertura, por falta de pormenores construtivos desses pontos ou erros de execução por parte do aplicador. Em muitos dos casos estudados, não foi detetada nenhuma anomalia, porque se considerou razoável considerar que o sistema impermeabilizante tenha atingido o fim de vida útil. O custo médio por metro quadrado associado à reabilitação de uma cobertura plana é influenciado principalmente por dois fatores: área e acessibilidade da cobertura. O tipo de anomalia e/ou a sua causa não determinaram o custo por metro quadrado da reparação efetuada, pois esta foi sempre de caracter integral e nunca pontual.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with the coupled effect of temperature and silica fume addition on rheological, mechanical behaviour and porosity of grouts based on CEMI 42.5R, proportioned with a polycarboxylate-based high range water reducer. Preliminary tests were conducted to focus on the grout best able to fill a fibrous network since the goal of this study was to develop an optimized grout able to be injected in a mat of steel fibers for concrete strengthening. The grout composition was developed based on criteria for fresh state and hardened state properties. For a CEMI 42.5R based grout different high range water reducer dosages (0%, 0.2%, 0.4%, 0.5%, 0.7%) and silica fume (SF) dosages (0%, 2%, 4%) were tested (as replacement of cement by mass). Rheological measurements were used to investigate the effect of polycarboxylates (PCEs) and SF dosage on grout properties, particularly its workability loss, as the mix was to be injected in a matrix of steel fibers for concrete jacketing. The workability behaviour was characterized by the rheological parameters yield stress and plastic viscosity (for different grout temperatures and resting times), as well as the procedures of mini slump cone and funnel flow time. Then, further development focused only on the best grout compositions. The cement substitution by 2% of SF exhibited the best overall behaviour and was considered as the most promising compared to the others compositions tested. Concerning the fresh state analysis, a significant workability loss was detected if grout temperature increased above 35 degrees C. Below this temperature the grout presented a self-levelling behaviour and a life time equal to 45 min. In the hardened state, silica fumes increased not only the grout's porosity but also the grout's compressive strength at later ages, since the pozzolanic contribution to the compressive strength does not occur until 28 d and beyond. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Contabilidade e Análise Financeira

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relatório de Estágio para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Edificações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os acidentes envolvendo veículos de duas rodas, são um dos maiores problemas da segurança rodoviária atual, no âmbito Europeu. Um dos tipos de acidentes que pode causar danos mais graves aos ocupantes desses veículos é o embate com guardas de segurança. Em consequência disso, neste trabalho foram desenvolvidas opiniões, abonatórias ou não, ao uso de dispositivos de proteção para motociclistas acoplados nas guardas de segurança. Estas opiniões vão partir de dados estatísticos, de estudos e exemplos concretos de vários autores e publicações relacionados com esta temática, sendo que o tipo de dispositivo de proteção para motociclistas que vai estar mais em foco e sendo ele o mais habitual nas estradas portuguesas será a saia metálica. Estes dispositivos de segurança para motociclistas ainda não são de uso obrigatório nas guardas de segurança na maioria dos países do continente Europeu, segundo a norma europeia EN 1317, apesar deste tipo de proteção já estar normalizada segundo padrões de lesões biomecânicos na zona da cabeça, cervical e anca/abdómen descritos na norma EN 1317 UNE 135900 – 1:2003, em alguns países é descurado o uso destas proteções, por não serem obrigatórias e porque ainda se tornam mais dispendiosas que as guardas de segurança habituais (barreiras de metal simples). Este estudo serviu essencialmente para verificar se estes dispositivos salvaguardam ou não a vida dos utilizadores de duas rodas, pois, se pelo contrário, aumentam ainda o risco, ou de lesões mais gravosas ou mesmo de morte, aquando o embate com as mesmas, os gastos associados a este tipo de equipamentos serão totalmente inúteis e desnecessários.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper shows several ways to analyse the performance of a safety barrier, depending on the objective to be achieved and present a method to analyse binary components usually present on sensor systems of safety barriers. An application example of a water-based fire system is presented and the Probability of Failure on Demand (PFD) of the sensor system is determined based on the analysis of pressure switches installed in this safety barrier. The knowledge of such information will allow the determination of safety barrier’s availability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Present paper present the main results obtained in the scope of an ongoing project which aims to contribute to the valorization of a waste generated by the Portuguese oil company in construction materials. This waste is an aluminosilicate with high pozzolanic reactivity. Several different technological applications had already been tested with success both in terms of properties and compliance with the corresponding standards specifications. Namely, this project results already demonstrated that this waste can be used in traditional concrete, self-compacted concrete, mortars (renders, masonry mortar, concrete repair mortars), cement main constituent as well as alkali activated binders.