27 resultados para Viganoni, Carlo Maria, 1786-1839.
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
We investigate the behavior of a patchy particle model close to a hard-wall via Monte Carlo simulation and density functional theory (DFT). Two DFT approaches, based on the homogeneous and inhomogeneous versions of Wertheim's first order perturbation theory for the association free energy are used. We evaluate, by simulation and theory, the equilibrium bulk phase diagram of the fluid and analyze the surface properties for two isochores, one of which is close to the liquid side of the gas-liquid coexistence curve. We find that the density profile near the wall crosses over from a typical high-temperature adsorption profile to a low-temperature desorption one, for the isochore close to coexistence. We relate this behavior to the properties of the bulk network liquid and find that the theoretical descriptions are reasonably accurate in this regime. At very low temperatures, however, an almost fully bonded network is formed, and the simulations reveal a second adsorption regime which is not captured by DFT. We trace this failure to the neglect of orientational correlations of the particles, which are found to exhibit surface induced orientational order in this regime.
Resumo:
Introdução: Porque o cateterismo ureteral “duplo J” implica a exposição do doente a radiação X, com tempos de exposição consideráveis, incidentes numa região anatómica constituída por diversos órgãos, existem dúvidas em relação aos riscos associados à dose de radiação acumulada pelos doentes. O objectivo deste trabalho centrou-se em clarificar estas dúvidas através da estimação quantitativa do risco de carcinogénese associado à dose de radiação. Método: Foram estudados dados relativos a 146 doentes submetidos a procedimentos de cateterismo ureteral “duplo J” no Serviço de Urologia do Hospital de Santa Maria (HSM). As doses eficazes foram determinadas através de métodos Monte Carlo. O risco de carcinogénese foi estimado com base na relação linear dose/efeito, sem limiar de dose, por coeficientes de probabilidade. Resultados: Como resultados mais relevantes, estimou-se que 1 colocação seguida de 1 extracção do cateter “duplo J” proporciona ao doente um risco acrescido de carcinogénese de 0,012%, ou seja, cerca de 1 doente em 8330 desenvolve cancro radio-induzido. Estima-se também, por exemplo, que um doente submetido a 1 colocação, 1 substituição e 1 extracção é, em média, submetido a uma dose eficaz de 4,47mSv, valor de dose semelhante ao proporcionado por uma TC abdominal. Conclusão: Quando comparamos os riscos associados à radiação com o benefício clínico de “poupar” a função renal, concluímos que os benefícios são inestimavelmente mais importantes que os riscos. De qualquer forma, verificamos que existe sempre, ainda que relativamente baixo, algum risco associado aos níveis de dose. Assim, os princípios da Justificação e da Optimização deverão ser sempre equacionados neste tipo de procedimentos.
Resumo:
O projecto “Principais tendências no cinema português contemporâneo” nasceu no Departamento de Cinema da ESTC, com o objectivo de desenvolver investigação especializada a partir de um núcleo formado por alunos da Licenciatura em Cinema e do Mestrado em Desenvolvimento de Projecto Cinematográfico, a que se juntaram professores-investigadores membros do CIAC e convidados. O que agora se divulga corresponde a dois anos e meio de trabalho desenvolvido pela equipa de investigação, entre Abril de 2009 e Novembro de 2011. Dada a forma que ele foi adquirindo, preferimos renomeá-lo, para efeitos de divulgação, “Novas & velhas tendências no cinema português contemporâneo”.
Resumo:
O projecto “Principais tendências no cinema português contemporâneo” nasceu no Departamento de Cinema da ESTC, com o objectivo de desenvolver investigação especializada a partir de um núcleo formado por alunos da Licenciatura em Cinema e do Mestrado em Desenvolvimento de Projecto Cinematográfico, a que se juntaram professores-investigadores membros do CIAC e convidados. O que agora se divulga corresponde a dois anos e meio de trabalho desenvolvido pela equipa de investigação, entre Abril de 2009 e Novembro de 2011. Dada a forma que ele foi adquirindo, preferimos renomeá-lo, para efeitos de divulgação, “Novas & velhas tendências no cinema português contemporâneo”.
Resumo:
O projecto “Principais tendências no cinema português contemporâneo” nasceu no Departamento de Cinema da ESTC, com o objectivo de desenvolver investigação especializada a partir de um núcleo formado por alunos da Licenciatura em Cinema e do Mestrado em Desenvolvimento de Projecto Cinematográfico, a que se juntaram professores-investigadores membros do CIAC e convidados. O que agora se divulga corresponde a dois anos e meio de trabalho desenvolvido pela equipa de investigação, entre Abril de 2009 e Novembro de 2011. Dada a forma que ele foi adquirindo, preferimos renomeá-lo, para efeitos de divulgação, “Novas & velhas tendências no cinema português contemporâneo”.
Acompanhamento da construção do Centro Escolar do Agrupamento nº 1 de Beja Escola EB1 de Santa Maria
Resumo:
O presente relatório traduz a sequência do Estágio Curricular realizado na Câmara Municipal de Beja, ao longo de 4 meses. Procurei com este documento, reflectir os conhecimentos adquiridos no decurso do estágio, sobretudo através da experiência que me foi concedida em poder viver o dia-a-dia de um Engenheiro Civil em obra, neste caso a construção do Centro Escolar do Agrupamento Nº 1 de Beja (Escola EBI Santa Maria). A estrutura do relatório está dividida em 4 partes, respeitantes essencialmente à construção da referida Escola. Uma introdução que aborda especificamente os objectivos do presente relatório, um capítulo que abrange o acompanhamento de todas as fases da construção da Escola Básica Nº1 e Jardim de Infância de Santa Maria, complementado com fotografias, um outro capítulo que integra os aspectos mais importantes sobre a Higiene e Segurança em Obra e ainda um outro sobre a Direcção e Fiscalização de Obra, que permitiu optimizar a gestão do processo construtivo. São também referidas outras obras acompanhadas ao longo do Estágio e finalmente a conclusão retirada deste percurso relevante para a aquisição de experiências de qualquer Engenheiro Civil recém-formado.
Resumo:
The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to increased interest in in vivo small animal imaging. Small animal imaging has been applied frequently to the imaging of small animals (mice and rats), which are ubiquitous in modeling human diseases and testing treatments. The use of PET in small animals allows the use of subjects as their own control, reducing the interanimal variability. This allows performing longitudinal studies on the same animal and improves the accuracy of biological models. However, small animal PET still suffers from several limitations. The amounts of radiotracers needed, limited scanner sensitivity, image resolution and image quantification issues, all could clearly benefit from additional research. Because nuclear medicine imaging deals with radioactive decay, the emission of radiation energy through photons and particles alongside with the detection of these quanta and particles in different materials make Monte Carlo method an important simulation tool in both nuclear medicine research and clinical practice. In order to optimize the quantitative use of PET in clinical practice, data- and image-processing methods are also a field of intense interest and development. The evaluation of such methods often relies on the use of simulated data and images since these offer control of the ground truth. Monte Carlo simulations are widely used for PET simulation since they take into account all the random processes involved in PET imaging, from the emission of the positron to the detection of the photons by the detectors. Simulation techniques have become an importance and indispensable complement to a wide range of problems that could not be addressed by experimental or analytical approaches.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Protecção contra Radiações
Resumo:
O presente estudo pretende demonstrar a importância do ensino explícito e sistemático do processo de escrita e dos seus subprocessos: a planificação, a textualização, a revisão e a edição, alunos do 4.º ano do 1.º Ciclo do Ensino Básico, como forma de contribuir para a melhoria da sua competência textual. Pretende-se que os alunos do grupo experimental interiorizem a dimensão processual da escrita, levando-os a planificar, textualizar, rever, e editar, de forma a escrever melhores textos: expositivos e descritivos. Nesse sentido, foi traçado um desenho investigativo assente no seguinte dispositivo pedagógico: pré-teste, plano de intervenção e ação e pós-teste. O plano de intervenção e ação consistiu na implementação de um Percurso de Ensino/Aprendizagem para a Compreensão do Processo de Escrita na Produção de um Texto Escrito, constituído por nove sequências didáticas. Constata-se, a partir de uma análise qualitativa dos pré e pós-testes, que houve uma progressão do grupo sujeito ao plano de intervenção e ação, quanto à interiorização da dimensão processual da escrita, produzindo, deste modo, textos com maior coesão e coerência, em comparação com o grupo de controlo, comprovando, assim, os objetivos e as questões orientadoras do estudo.
Resumo:
We investigate, via numerical simulations, mean field, and density functional theories, the magnetic response of a dipolar hard sphere fluid at low temperatures and densities, in the region of strong association. The proposed parameter-free theory is able to capture both the density and temperature dependence of the ring-chain equilibrium and the contribution to the susceptibility of a chain of generic length. The theory predicts a nonmonotonic temperature dependence of the initial (zero field) magnetic susceptibility, arising from the competition between magnetically inert particle rings and magnetically active chains. Monte Carlo simulation results closely agree with the theoretical findings. DOI: 10.1103/PhysRevLett.110.148306
Resumo:
We investigate the phase behaviour of 2D mixtures of bi-functional and three-functional patchy particles and 3D mixtures of bi-functional and tetra-functional patchy particles by means of Monte Carlo simulations and Wertheim theory. We start by computing the critical points of the pure systems and then we investigate how the critical parameters change upon lowering the temperature. We extend the successive umbrella sampling method to mixtures to make it possible to extract information about the phase behaviour of the system at a fixed temperature for the whole range of densities and compositions of interest. (C) 2013 AIP Publishing LLC.
Resumo:
In this contribution, we investigate the low-temperature, low-density behaviour of dipolar hard-sphere (DHS) particles, i.e., hard spheres with dipoles embedded in their centre. We aim at describing the DHS fluid in terms of a network of chains and rings (the fundamental clusters) held together by branching points (defects) of different nature. We first introduce a systematic way of classifying inter-cluster connections according to their topology, and then employ this classification to analyse the geometric and thermodynamic properties of each class of defects, as extracted from state-of-the-art equilibrium Monte Carlo simulations. By computing the average density and energetic cost of each defect class, we find that the relevant contribution to inter-cluster interactions is indeed provided by (rare) three-way junctions and by four-way junctions arising from parallel or anti-parallel locally linear aggregates. All other (numerous) defects are either intra-cluster or associated to low cluster-cluster interaction energies, suggesting that these defects do not play a significant part in the thermodynamic description of the self-assembly processes of dipolar hard spheres. (C) 2013 AIP Publishing LLC.
Resumo:
Objective - To describe and validate the simulation of the basic features of GE Millennium MG gamma camera using the GATE Monte Carlo platform. Material and methods - Crystal size and thickness, parallel-hole collimation and a realistic energy acquisition window were simulated in the GATE platform. GATE results were compared to experimental data in the following imaging conditions: a point source of 99mTc at different positions during static imaging and tomographic acquisitions using two different energy windows. The accuracy between the events expected and detected by simulation was obtained with the Mann–Whitney–Wilcoxon test. Comparisons were made regarding the measurement of sensitivity and spatial resolution, static and tomographic. Simulated and experimental spatial resolutions for tomographic data were compared with the Kruskal–Wallis test to assess simulation accuracy for this parameter. Results - There was good agreement between simulated and experimental data. The number of decays expected when compared with the number of decays registered, showed small deviation (≤0.007%). The sensitivity comparisons between static acquisitions for different distances from source to collimator (1, 5, 10, 20, 30cm) with energy windows of 126–154 keV and 130–158 keV showed differences of 4.4%, 5.5%, 4.2%, 5.5%, 4.5% and 5.4%, 6.3%, 6.3%, 5.8%, 5.3%, respectively. For the tomographic acquisitions, the mean differences were 7.5% and 9.8% for the energy window 126–154 keV and 130–158 keV. Comparison of simulated and experimental spatial resolutions for tomographic data showed no statistically significant differences with 95% confidence interval. Conclusions - Adequate simulation of the system basic features using GATE Monte Carlo simulation platform was achieved and validated.
Resumo:
Purpose: The most recent Varian® micro multileaf collimator(MLC), the High Definition (HD120) MLC, was modeled using the BEAMNRCMonte Carlo code. This model was incorporated into a Varian medical linear accelerator, for a 6 MV beam, in static and dynamic mode. The model was validated by comparing simulated profiles with measurements. Methods: The Varian® Trilogy® (2300C/D) accelerator model was accurately implemented using the state-of-the-art Monte Carlo simulation program BEAMNRC and validated against off-axis and depth dose profiles measured using ionization chambers, by adjusting the energy and the full width at half maximum (FWHM) of the initial electron beam. The HD120 MLC was modeled by developing a new BEAMNRC component module (CM), designated HDMLC, adapting the available DYNVMLC CM and incorporating the specific characteristics of this new micro MLC. The leaf dimensions were provided by the manufacturer. The geometry was visualized by tracing particles through the CM and recording their position when a leaf boundary is crossed. The leaf material density and abutting air gap between leaves were adjusted in order to obtain a good agreement between the simulated leakage profiles and EBT2 film measurements performed in a solid water phantom. To validate the HDMLC implementation, additional MLC static patterns were also simulated and compared to additional measurements. Furthermore, the ability to simulate dynamic MLC fields was implemented in the HDMLC CM. The simulation results of these fields were compared with EBT2 film measurements performed in a solid water phantom. Results: Overall, the discrepancies, with and without MLC, between the opened field simulations and the measurements using ionization chambers in a water phantom, for the off-axis profiles are below 2% and in depth-dose profiles are below 2% after the maximum dose depth and below 4% in the build-up region. On the conditions of these simulations, this tungsten-based MLC has a density of 18.7 g cm− 3 and an overall leakage of about 1.1 ± 0.03%. The discrepancies between the film measured and simulated closed and blocked fields are below 2% and 8%, respectively. Other measurements were performed for alternated leaf patterns and the agreement is satisfactory (to within 4%). The dynamic mode for this MLC was implemented and the discrepancies between film measurements and simulations are within 4%. Conclusions: The Varian® Trilogy® (2300 C/D) linear accelerator including the HD120 MLC was successfully modeled and simulated using the Monte CarloBEAMNRC code by developing an independent CM, the HDMLC CM, either in static and dynamic modes.
The use of non-standard CT conversion ramps for Monte Carlo verification of 6 MV prostate IMRT plans
Resumo:
Monte Carlo (MC) dose calculation algorithms have been widely used to verify the accuracy of intensity-modulated radiotherapy (IMRT) dose distributions computed by conventional algorithms due to the ability to precisely account for the effects of tissue inhomogeneities and multileaf collimator characteristics. Both algorithms present, however, a particular difference in terms of dose calculation and report. Whereas dose from conventional methods is traditionally computed and reported as the water-equivalent dose (Dw), MC dose algorithms calculate and report dose to medium (Dm). In order to compare consistently both methods, the conversion of MC Dm into Dw is therefore necessary. This study aims to assess the effect of applying the conversion of MC-based Dm distributions to Dw for prostate IMRT plans generated for 6 MV photon beams. MC phantoms were created from the patient CT images using three different ramps to convert CT numbers into material and mass density: a conventional four material ramp (CTCREATE) and two simplified CT conversion ramps: (1) air and water with variable densities and (2) air and water with unit density. MC simulations were performed using the BEAMnrc code for the treatment head simulation and the DOSXYZnrc code for the patient dose calculation. The conversion of Dm to Dw by scaling with the stopping power ratios of water to medium was also performed in a post-MC calculation process. The comparison of MC dose distributions calculated in conventional and simplified (water with variable densities) phantoms showed that the effect of material composition on dose-volume histograms (DVH) was less than 1% for soft tissue and about 2.5% near and inside bone structures. The effect of material density on DVH was less than 1% for all tissues through the comparison of MC distributions performed in the two simplified phantoms considering water. Additionally, MC dose distributions were compared with the predictions from an Eclipse treatment planning system (TPS), which employed a pencil beam convolution (PBC) algorithm with Modified Batho Power Law heterogeneity correction. Eclipse PBC and MC calculations (conventional and simplified phantoms) agreed well (<1%) for soft tissues. For femoral heads, differences up to 3% were observed between the DVH for Eclipse PBC and MC calculated in conventional phantoms. The use of the CT conversion ramp of water with variable densities for MC simulations showed no dose discrepancies (0.5%) with the PBC algorithm. Moreover, converting Dm to Dw using mass stopping power ratios resulted in a significant shift (up to 6%) in the DVH for the femoral heads compared to the Eclipse PBC one. Our results show that, for prostate IMRT plans delivered with 6 MV photon beams, no conversion of MC dose from medium to water using stopping power ratio is needed. In contrast, MC dose calculations using water with variable density may be a simple way to solve the problem found using the dose conversion method based on the stopping power ratio.