14 resultados para Static average-case analysis

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The three-dimensional (3D) exact solutions developed in the early 1970s by Pagano for simply supported multilayered orthotropic composite plates and later in the 1990s extended to piezoelectric plates by Heyliger have been extremely useful in the assessment and development of advanced laminated plate theories and related finite element models. In fact, the well-known test cases provided by Pagano and by Heyliger in those earlier works are still used today as benchmark solutions. However, the limited number of test cases whose 3D exact solutions have been published has somewhat restricted the assessment of recent advanced models to the same few test cases. This work aims to provide additional test cases to serve as benchmark exact solutions for the static analysis of multilayered piezoelectric composite plates. The method introduced by Heyliger to derive the 3D exact solutions has been successfully implemented using symbolic computing and a number of new test cases are here presented thoroughly. Specifically, two multilayered plates using PVDF piezoelectric material are selected as test cases under two different loading conditions and considering three plate aspect ratios for thick, moderately thick and thin plate, in a total of 12 distinct test cases. (C) 2013 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Oporto Airport located in the northern region in Porto city is crucial because is the only one located in the northern region. This airport had an increasing in number of passengers, sales revenue and accumulated investment during the last two decades, principally after the introduction and the operation of the Low Cost Companies since 2004 to the present. In order to determine if the last changes had an impact in the competitiveness of this airport, the main aims is to analise the evolution of values of the technical efficiency and equate the results before and after the introduction of the LCCs in this airport. The methodology uses the Data Envelopment Analysis. Results show that the Oporto Airport efficiency increases highly after the introduction of LCCs since 2004. The main conclusions suggest the importance of the introduction of LCCs in the increasing efficiency of the Oporto Airport and the potential relation with tourism development in this region, but more strong studies are needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Formaldehyde, classified by the IARC as carcinogenic in humans and experimental animals, is a chemical agent that is widely used in histopathology laboratories. The exposure to this substance is epidemiologically linked to cancer and to nuclear changes detected by the cytokinesis-block micronucleus test (CBMN). This method is extensively used in molecular epidemiology, since it provides information on several biomarkers of genotoxicity, such as micronuclei (MN), which are biomarkers of chromosomes breakage or loss, nucleoplasmic bridges (NPB), common biomarkers of chromosome rearrangement, poor repair and/or telomere fusion, and nuclear buds (NBUD), biomarkers of elimination of amplified DNA. The aim of this study is to compare the frequency of genotoxicity biomarkers, provided by the CBMN assay in peripheral lymphocytes and the MN test in buccal cells, between individuals occupationally exposed and non-exposed to formaldehyde and other environmental factors, namely tobacco and alcohol consumption. The sample comprised two groups: 56 individuals occupationally exposed to formaldehyde (cases) and 85 unexposed individuals (controls), from whom both peripheral blood and exfoliated epithelial cells of the oral mucosa were collected in order to measure the genetic endpoints proposed in this study. The mean level of TWA8h was 0.16±0.11ppm (analysis of confounding factors showed that there were no differences between genders. As for age, only the mean MN frequency in lymphocytes was found significantly higher in elderly people among the exposed groups (p = 0.006), and there was also evidence of an interaction between age and gender with regards to that biomarker in those exposed. Smoking habits did not influence the frequency of the biomarkers, whereas alcohol consumption only influenced the MN frequency in lymphocytes in controls (p = 0.011), with drinkers showing higher mean values. These results provide evidence of the association between occupational exposure to formaldehyde and the presence of genotoxicity biomarkers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As wind power generation undergoes rapid growth, lightning and overvoltage incidents involving wind power plants have come to be regarded as a serious problem. Firstly, lightning location systems are discussed, as well as important parameters regarding lightning protection. Also, this paper presents a case study, based on a wind turbine with an interconnecting transformer, for the study of adequate lightning and overvoltage protection measures. The electromagnetic transients circuit under study is described, and computational results are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Os sistemas de armas da Força Aérea Portuguesa (FAP) têm por missão a defesa militar de Portugal, através de operações aéreas e da defesa do espaço aéreo nacional, sendo o F-16 o principal avião de ataque em uso nesta organização. Neste sentido, e tendo em conta o actual contexto económico mundial, as organizações devem rentabilizar todos os recursos disponíveis, custos associados e optimizar processos de trabalho. Tendo por base os pressupostos anteriores, o presente estudo pretende analisar a implementação de lean na FAP, uma vez que esta filosofia assenta na eliminação de desperdícios com vista a uma melhoria da qualidade e diminuição de tempos e custos. Posto isto, a análise deste trabalho vai recair sobre a área de manutenção do F-16, em concreto na Inspeção de Fase (IF), um tipo de manutenção que esta aeronave realiza a cada trezentas horas de voo. O estudo de caso vai incidir em dois momentos da IF: o primeiro ponto relaciona-se com o processamento da recolha de dados para a reunião preliminar onde são definidas, para as áreas de trabalho executantes, as ações de manutenção a realizar com a paragem da aeronave. Deste modo, pretende-se averiguar as causas inerentes aos atrasos verificados para a realização desta reunião. O segundo ponto em observação compreende a informação obtida através da aplicação informática SIAGFA, em uso na FAP, para o processamento de dados de manutenção das quatro aeronaves que inauguraram a IF com a filosofia lean. Esta análise permitiu perceber o número de horas de trabalho dispendidas (em média pelas quatro aeronaves) por cada uma das cartas de trabalho, verificando-se que as cartas adicionais comportam mais horas; foi possível compreender quais as áreas de trabalho consideradas críticas; foram identificados os dias de trabalho realizado e tempos de paragem sem qualquer tipo de intervenção. Foi ainda avaliado, por aeronave, o número de horas de trabalho realizadas na IF e quais os constrangimentos que se verificaram nas aeronaves, que não realizaram a IF no tempo definido para tal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reclaimed water from small wastewater treatment facilities in the rural areas of the Beira Interior region (Portugal) may constitute an alternative water source for aquifer recharge. A 21-month monitoring period in a constructed wetland treatment system has shown that 21,500 m(3) year(-1) of treated wastewater (reclaimed water) could be used for aquifer recharge. A GIS-based multi-criteria analysis was performed, combining ten thematic maps and economic, environmental and technical criteria, in order to produce a suitability map for the location of sites for reclaimed water infiltration. The areas chosen for aquifer recharge with infiltration basins are mainly composed of anthrosol with more than 1 m deep and fine sand texture, which allows an average infiltration velocity of up to 1 m d(-1). These characteristics will provide a final polishing treatment of the reclaimed water after infiltration (soil aquifer treatment (SAT)), suitable for the removal of the residual load (trace organics, nutrients, heavy metals and pathogens). The risk of groundwater contamination is low since the water table in the anthrosol areas ranges from 10 m to 50 m. Oil the other hand, these depths allow a guaranteed unsaturated area suitable for SAT. An area of 13,944 ha was selected for study, but only 1607 ha are suitable for reclaimed water infiltration. Approximately 1280 m(2) were considered enough to set up 4 infiltration basins to work in flooding and drying cycles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A descriptive study was developed in order to assess air contamination caused by fungi and particles in seven poultry units. Twenty seven air samples of 25 litters were collected through impaction method. Air sampling and particle concentration measurement were performed in the pavilions’ interior and also outside premises, since this was the place regarded as reference. Simultaneously, temperature and relative humidity were also registered. Regarding fungal load in the air from the seven poultry farms, the highest value obtained was 24040 CFU/m3 and the lowest was 320 CFU/m3. Twenty eight species/genera of fungi were identified, being Scopulariopsis brevicaulis (39.0%) the most commonly isolated species and Rhizopus sp. (30.0%) the most commonly isolated genus. From the Aspergillus genus, Aspergillus flavus (74.5%) was the most frequently detected species. There was a significant correlation (r=0.487; p=0.014) between temperature and the level of fungal contamination (CFU/m3). Considering contamination caused by particles, in this study, particles with larger dimensions (PM5.0 and PM10) have higher concentrations. There was also a significant correlation between relative humidity and concentration of smaller particles namely, PM0.5 (r=0.438; p=0.025) and PM1.0 (r=0.537; p=0.005). Characterizing typical exposure levels to these contaminants in this specific occupational setting is required to allow a more detailed risk assessment analysis and to set exposure limits to protect workers’ health.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A presente dissertação tem como objetivo efetuar a análise comparativa de soluções adotadas de reabilitação de pavimentos flexíveis que integram a rede rodoviária nacional. No âmbito desta análise apresenta-se o estado da arte respeitante à reabilitação de pavimentos flexíveis, nomeadamente: mecanismos de degradação, famílias de degradações, avaliação da capacidade de carga dos pavimentos, metodologia utilizada no dimensionamento do reforço de pavimentos, sendo também efetuada uma análise comparativa de técnicas de reforço de pavimentos e dos tratamentos antifendas. Neste contexto, apresenta-se um caso de estudo no qual é efetuada uma análise de três soluções possíveis para a reabilitação estrutural do pavimento do IC 20 entre Almada e a Costa de Caparica. É feita a descrição da solução projetada pela EP, SA patenteada em concurso público lançado em 2007, a qual é de certa forma inovadora ao nível do tratamento retardador da reflexão de fendas. Aquela solução técnica é constituída pela aplicação de grelhas de fibra de vidro e grelhas de fibra de carbono, seguidas da colocação de uma camada de desgaste em mistura betuminosa rugosa com betume modificado com baixa percentagem de borracha reciclada de pneus usados (BBr - BBB). Complementarmente, é efetuada a análise da solução do projeto de reabilitação do IC 20, patenteado pela Subconcessionária do Baixo Tejo, que contemplou a aplicação de misturas betuminosas rugosas com betume modificado com média percentagem de borracha reciclada de pneus usados (BBr - BBM). Para além da solução patenteada pela subconcessionária, é analisada a solução do projeto de alterações (variante) apresentado pelo agrupamento de empresas construtoras, que foi adotado na execução da obra realizada no IC 20. A intervenção de reabilitação estrutural contemplou a utilização de uma camada de ligação em AC 16 10/20 (MBAM) e uma camada de desgaste em mistura betuminosa rugosa com betume modificado com média percentagem de borracha reciclada de pneus usados (BBr - BBM). Adicionalmente à caracterização de diferentes soluções de reabilitação de pavimentos flexíveis adotados em Portugal, é efetuada uma análise comparativa dos custos de ciclo de vida (construção, manutenção e conservação) de cada tipo de solução de reabilitação.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Área de especialização: Terapia com Radiações.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Functionally graded materials are composite materials wherein the composition of the constituent phases can vary in a smooth continuous way with a gradation which is function of its spatial coordinates. This characteristic proves to be an important issue as it can minimize abrupt variations of the material properties which are usually responsible for localized high values of stresses, and simultaneously providing an effective thermal barrier in specific applications. In the present work, it is studied the static and free vibration behaviour of functionally graded sandwich plate type structures, using B-spline finite strip element models based on different shear deformation theories. The effective properties of functionally graded materials are estimated according to Mori-Tanaka homogenization scheme. These sandwich structures can also consider the existence of outer skins of piezoelectric materials, thus achieving them adaptive characteristics. The performance of the models, are illustrated through a set of test cases. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction - The increasing of TB burden is usually related to inadequate case detection, diagnosis and cure. Global targets for TB control, adopted by the World Health Organization (WHO), are to detect 70% of the estimated incidence of sputum smear-positive TB and to cure 85% of newly detected cases of sputum smear-positive TB. Factors associated with unsuccessful treatment outcomes are closely related to TB risk factors. Objectives - To describe treatment success rates in pulmonary TB cases and to identify factors associated with unsuccessful treatment outcomes, according to ad-hoc studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives - Evaluate the nutritional status of patients with inactive or mildly active Crohn's disease (CD), and identify possible causes for potential deficiencies. Methods - A total of 78 CD patients and 80 healthy controls were evaluated in respect of nutritional status, dietary intake, and life styles factors. Results - These 73/78 CD patients were on immunomodulating therapies. Mean body mass index (BMI) was lower in patients as compared to controls (P= 0.006) but 32% of CD patients and 33.8% of controls had a BMI > 25, whereas 8% and 23.8% in each group, respectively, were obese (BMI > 30Kg/m(2)). Fat free mass was significantly decreased in both genders (P < 0.05) whereas fat mass was decreased only in males (P= 0.01). Energy intake was significantly lower in CD patients (P < 0.0001) and we observed significantly lower adjusted mean daily intakes of carbohydrates, monounsaturated fat, fiber, calcium, and vitamins C, D, E, and K (P < 0.05). 29% of patients had excluded grains from their usual diet, 28% milk, 18% vegetables, and 11% fruits. Milk exclusion resulted in a significantly lower consumption of calcium and vitamin K (P < 0.001) and the exclusion of vegetables was associated to a lower consumption of vitamins C and E (P < 0.05). Physical activity was significantly lower in CD patients (P= 0.01) and this lack of physical activity was inversely correlated with increased fat mass percentage (r=-0.315, P= 0.001). Conclusions - Results showed that the most prevalent form of malnutrition in CD patients was an excess of body weight, which was concomitant with an inadequate dietary intake, namely micronutrients, clearly related to dietary exclusion of certain foods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica na Área de Manutenção e Produção

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Master Thesis in Mechanical Engineering field of Maintenance and Production