10 resultados para Source reduction (Waste management)

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction - Occupational exposures are characterized by being complex and associated to co-exposure to several contaminants by different exposure routes. Even if exposure occurs to only a chemical agent, it can have different exposure routes and can result in different health effects. The waste management setting is recognized by the presence of several chemical and biologic agents in the workplaces. Recently, it was reported occupational exposure to Aflatoxin B1 (AFB1) in one Portuguese waste management industry. However, data regarding to fungal burden showed that exposure to other mycotoxins should be expected. Aim of the study - The aim of the present work was to know if workers from this waste management industry were exposed to other mycotoxins besides AFB1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre Em Engenharia Química e Biológica Ramo de processos Químicos

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Edificações

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aspergillus fumigatus is one of the major ubiquitous saprophytic fungi and it is considered one of the fungal species with higher clinical relevance. This study aimed at characterising the prevalence of A. fumigatus complex in one waste-sorting plant and also in one incineration plant. Conventional and molecular methodologies were applied in order to detect its presence. Aspergillus fumigatus complex was the second most frequently found in the air from the waste-sorting plant (16.0%) and from the incineration plant (18.0%). Regarding surfaces, it ranked the third species most frequently found in the waste-sorting plant (13.8%) and the second in the incineration plant (22.3%). In the waste-sorting plant, it was possible to amplify by qPCR DNA from the A. fumigatus complex in all culture-positive sampling sites plus one other sampling site that was negative by culture analysis. Considering the observed fungal load, it is recommended to apply preventive and protective measures in order to avoid or minimise worker's exposure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Relatório de estágio para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Edificações

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Vias de Comunicação e Transportes

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil, na Área de Especialização de Hidráulica

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Mycological contamination of occupational environments can be a result of fungal spores’ dispersion in the air and on surfaces. Therefore, it is very important to assess it in both types of the samples. In the present study we assessed fungal contamination in the air and in the surface samples to show relevance of surfaces sampling in complementing the results obtained in the air samples. Material and Methods: In total, 42 settings were assessed by the analysis of air and surfaces samples. The settings were divided into settings with a high fungal load (7 poultry farms and 7 pig farms, 3 cork industries, 3 waste management plants, 2 wastewater treatment plants and 1 horse stable) and a low fungal load (10 hospital canteens, 8 college canteens and 1 maternity hospital). In addition to culture-based methods, molecular tools were also applied to detect fungal burden in the settings with a higher fungal load. Results: From the 218 sampling sites, 140 (64.2%) presented different species in the examined surfaces when compared with the species identified in the air. A positive association in the high fungal load settings was found between the presence of different species in the air and surfaces. Wastewater treatment plants constituted the setting with the highest number of different species between the air and surface. Conclusions: We observed that surfaces sampling and application of molecular tools showed the same efficacy of species detection in high fungal load settings, corroborating the fact that surface sampling is crucial for a correct and complete analysis of occupational scenarios.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Relatório de Estágio para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Edificações

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sampling the total air concentration of particulate matter (PM) only provides a basic estimate of exposure that normally not allows correlating with the observed health effects. Therefore is of extreme importance to know the particles size distribution and, in more detail, the exposure to fine particles (≤ 2.5 µm). This particles dimension corresponds to the respirable fraction. This particle fraction can result, besides local effects, in systemic effects due to particle deposition and clearance from the lungs and transport within the organism. This study intended to describe occupational exposure to PM2.5 in three different units located near Lisbon and related with occupational exposure to organic dust, namely: swine and poultry feed production and waste management.