28 resultados para Solid-surfaces
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
The aim of the present work was to investigate the wetting behaviour of biomedical grade Ti-6Al-4V alloy surfaces textured by a femtosecond laser treatment. The material was treated in ambient atmosphere using an Yb: KYW chirped-pulse-regenerative amplification laser with a wavelength of 1030 nm and a pulse duration of 500 fs. Four main types of surface textures were obtained depending on the processing parameters and laser treatment method. These textures consist of: (1) nanoscale laser-induced periodic surface structures (LIPSS); (2) nanopillars; (3) a bimodal roughness distribution texture formed of LIPSS overlapping microcolumns; (4) a complex texture formed of LIPSS overlapping microcolumns with a periodic variation of the columns size in the laser scanning direction. The wettability of the surfaces was evaluated by the sessile drop method using distilled-deionized (DD) water and Hank's balanced salt solution (HBSS) as testing liquids. The laser treated surfaces present a hydrophilic behaviour as well as a high affinity for the saline solution, with equilibrium contact angles in the ranges 24.1-76.2. for DD water and 8.4-61.8. for HBSS. The wetting behaviour is anisotropic, reflecting the anisotropy of the surface textures. (c) 2012 Elsevier B.V. All rights reserved.
Resumo:
Recent advances in vacuum sciences and applications are reviewed. Novel optical interferometer cavity devices enable pressure measurements with ppm accuracy. The innovative dynamic vacuum standard allows for pressure measurements with temporal resolution of 2 ms. Vacuum issues in the construction of huge ultra-high vacuum devices worldwide are reviewed. Recent advances in surface science and thin films include new phenomena observed in electron transport near solid surfaces as well as novel results on the properties of carbon nanomaterials. Precise techniques for surface and thin-film characterization have been applied in the conservation technology of cultural heritage objects and recent advances in the characterization of biointerfaces are presented. The combination of various vacuum and atmospheric-pressure techniques enables an insight into the complex phenomena of protein and other biomolecule conformations on solid surfaces. Studying these phenomena at solid-liquid interfaces is regarded as the main issue in the development of alternative techniques for drug delivery, tissue engineering and thus the development of innovative techniques for curing cancer and cardiovascular diseases. A review on recent advances in plasma medicine is presented as well as novel hypotheses on cell apoptosis upon treatment with gaseous plasma. Finally, recent advances in plasma nanoscience are illustrated with several examples and a roadmap for future activities is presented.
Resumo:
We have generalized earlier work on anchoring of nematic liquid crystals by Sullivan, and Sluckin and Poniewierski, in order to study transitions which may occur in binary mixtures of nematic liquid crystals as a function of composition. Microscopic expressions have been obtained for the anchoring energy of (i) a liquid crystal in contact with a solid aligning surface; (ii) a liquid crystal in contact with an immiscible isotropic medium; (iii) a liquid crystal mixture in contact with a solid aligning surface. For (iii), possible phase diagrams of anchoring angle versus dopant concentration have been calculated using a simple liquid crystal model. These exhibit some interesting features including re-entrant conical anchoring, for what are believed to be realistic values of the molecular parameters. A way of relaxing the most drastic approximation implicit in the above approach is also briefly discussed.
Resumo:
A new circuit topology is proposed to replace the actual pulse transformer and thyratron based resonant modulator that supplies the 60 kV target potential for the ion acceleration of the On-Line Isotope Mass Separator accelerator, the stability of which is critical for the mass resolution downstream separator, at the European Organization for Nuclear Research. The improved modulator uses two solid-state switches working together, each one based on the Marx generator concept, operating as series and parallel switches, reducing the stress on the series stacked semiconductors, and also as auxiliary pulse generator in order to fulfill the target requirements. Preliminary results of a 10 kV prototype, using 1200 V insulated gate bipolar transistors and capacitors in the solid-state Marx circuits, ten stages each, with an electrical equivalent circuit of the target, are presented, demonstrating both the improved voltage stability and pulse flexibility potential wanted for this new modulator.
Resumo:
The wettability of polyimide surfaces microstructured using KrF laser radiation at fluences above the material ablation threshold was studied by static contact angle measurements. The laser-treated surfaces present a morphology consisting of conical features whose dimensions and areal density depend on the fluence. The effect of these parameters on the surface apparent contact angle depends on the wetting regime. When wetting occurs in the homogeneous regime, the apparent contact angle of the treated surfaces increases with the radiation fluence because the cone dimensions increase. In contrast, when wetting occurs in the heterogeneous regime, the apparent contact angle increases with the radiation fluence because the average distance between cones increases. The apparent water contact angle of the laser-treated surfaces can reach values as high as 162 degrees, as compared to 75 degrees for virgin polyimide.
Resumo:
A newly developed solid-state repetitive high-voltage (HV) pulse modulator topology created from the mature concept of the d.c. voltage multiplier (VM) is described. The proposed circuit is based in a voltage multiplier type circuit, where a number of d.c. capacitors share a common connection with different voltage rating in each one. Hence, besides the standard VM rectifier and coupling diodes, two solid-state on/off switches are used, in each stage, to switch from the typical charging VM mode to a pulse mode with the d.c. capacitors connected in series with the load. Due to the on/off semiconductor configuration, in half-bridge structures, the maximum voltage blocked by each one is the d.c. capacitor voltage in each stage. A 2 kV prototype is described and the results are compared with PSPICE simulations.
Resumo:
The evolution of the topography of titanium surfaces treated with femtosecond laser radiation in stationary conditions as a function of radiation fluence and number of laser pulses is investigated. Depending on the processing parameters, ripples, microcolumns, wavy or smooth surfaces can be obtained. The ripples predominate for fluences near the damage threshold of titanium (0.2+/-0.1) J/cm(2), while microcolumns form during the first 200 pulses for fluences between (0.6+/-0.2) and (1.7+/-0.2) J/cm(2). A wavy topography develops for fluences and number of pulses higher than (1.7+/-0.2) J/cm(2) and 300, respectively. A bimodal surface topography consisting of surface ripples overlapping a microcolumnar topography can be obtained if the surfaces are firstly treated to create microcolumns followed by laser treatment with a lower fluence near the ablation threshold of the material, in order to generate periodic ripple
Resumo:
We investigate nematic wetting and filling transitions of crenellated surfaces (rectangular gratings) by numerical minimization of the Landau-de Gennes free energy as a function of the anchoring strength, for a wide range of the surface geometrical parameters: depth, width, and separation of the crenels. We have found a rich phase behavior that depends in detail on the combination of the surface parameters. By comparison to simple fluids, which undergo a continuous filling or unbending transition, where the surface changes from a dry to a filled state, followed by a wetting or unbinding transition, where the thickness of the adsorbed fluid becomes macroscopic and the interface unbinds from the surface, nematics at crenellated surfaces reveal an intriguingly rich behavior: in shallow crenels only wetting is observed, while in deep crenels, only filling transitions occur; for intermediate surface geometrical parameters, a new class of filled states is found, characterized by bent isotropic-nematic interfaces, which persist for surfaces structured on large scales, compared to the nematic correlation length. The global phase diagram displays two wet and four filled states, all separated by first-order transitions. For crenels in the intermediate regime re-entrant filling transitions driven by the anchoring strength are observed.
Resumo:
This paper addresses the voltage droop compensation associated with long pulses generated by solid-stated based high-voltage Marx topologies. In particular a novel design scheme for voltage droop compensation in solid-state based bipolar Marx generators, using low-cost circuitry design and control, is described. The compensation consists of adding one auxiliary PWM stage to the existing Marx stages, without changing the modularity and topology of the circuit, which controls the output voltage and a LC filter that smoothes the voltage droop in both the positive and negative output pulses. Simulation results are presented for 5 stages Marx circuit using 1 kV per stage, with 1 kHz repetition rate and 10% duty cycle.
Resumo:
The purpose of this paper is to present and discuss a general HV topology of the solid-state Marx modulator, for unipolar or bipolar generation connected with a step-up transformer to increase the output voltage applied to a resistive load. Due to the use of an output transformer, discussion about the reset of the transformer is made to guarantee zero average voltage applied to the primary. It is also discussed the transformer magnetizing energy recovering back to the energy storage capacitors. Simulation results for a circuit that generates 100 kV pulses using 1000 V semiconductors are presented and discussed regarding the voltage and current stress on the semiconductors and result obtained.
Resumo:
We study wetting and filling of patterned surfaces by a nematic liquid crystal. We focus on three important classes of periodic surfaces: triangular, sinusoidal and rectangular. The results highlight the similarities and differences of nematic wetting of these surfaces and wetting by simple fluids. The interplay of geometry, surface and elastic energies can lead to the suppression of either filling or wetting. The periodic rectangular surface displays re-entrant transitions, with a sequence dry-filled-wet-filled, in the relevant region of parameter space.
Resumo:
Sub-nanosecond bipolar high voltage pulses are a very important tool for food processing, medical treatment, waste water and exhaust gas processing. A Hybrid Modulator for sub-microsecond bipolar pulse generation, comprising an unipolar solid-state Marx generator connected to a load through a stack Blumlein system that produces bipolar pulses and further multiplies the pulse voltage amplitude, is presented. Experimental results from an assembled prototype show the generation of 1000 V amplitude bipolar pulses with 100 ns of pulse width and 1 kHz repetition rate.
Resumo:
This paper, reports experimental work on the use of new heterogeneous solid basic catalysts for biodiesel production: double oxides of Mg and Al, produced by calcination, at high temperature, of MgAl lamellar structures, the hydrotalcites (HT). The most suitable catalyst system studied are hydrotalcite Mg:Al 2:1 calcinated at 507 degrees C and 700 degrees C, leading to higher values of FAME also in the second reaction stage. One of the prepared catalysts resulted in 97.1% Fatty acids methyl esters (FAME) in the 1st reaction step, 92.2% FAME in the 2nd reaction step and 34% FAME in the 3rd reaction step. The biodiesel obtained in the transesterification reaction showed composition and quality parameters within the limits specified by the European Standard EN 14214. 2.5% wt catalyst/oil and a molar ratio methanol:oil of 9:1 or 12:1 at 60 -65 degrees C and 4 h of reaction time are the best operating conditions achieved in this study. This study showed the potential of Mg/Al hydrotalcites as heterogeneous catalysts for biodiesel production. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Na indústria farmacêutica, a limpeza dos equipamentos e superfícies é muito importante no processo de fabrico/embalagem dos produtos farmacêuticos. Possíveis resíduos contaminantes devem ser removidos dos equipamentos e das superfícies envolvidas no processo. De acordo com as Boas Práticas de Fabrico (GMP), os procedimentos de limpeza e os métodos analíticos usados para determinar as quantidades de resíduos devem ser validados. O método analítico combinado com o método de amostragem utilizado na colheita de amostras deve ser sujeito a um ensaio de “recovery”. Neste trabalho apresenta-se uma estratégia inovadora para a validação de limpeza de formas farmacêuticas semi-sólidas. Propõe-se o uso de um método de amostragem que consiste na colheita direta de amostra após o seu fabrico, sendo a análise de resíduos feita directamente nesta amostra. Os produtos escolhidos para a avaliação da estratégia foram dois medicamentos dermatológicos, apresentados na forma de pomada e produzidos numa unidade de fabrico de vários produtos, pela Schering Plough Farma/ Merck Sharp & Dohme (Cacém, Portugal). Como métodos analíticos para a quantificação dos resíduos, utilizaram-se métodos validados por via espectrofotométrica (HPLC), usados na análise do produto acabado. A validação de limpeza foi avaliada através da análise de uma quantidade conhecida de pomada (produto B (*)), usando o método de análise da pomada fabricada anteriormente (produto A (*)), de modo a verificar-se a existência ou não de agente de limpeza e substâncias ativas deixadas após a limpeza do produto A, e vice-versa. As concentrações residuais das substâncias ativas e do agente de limpeza encontradas após a limpeza foram nulas, ou seja, inferiores ao limite de deteção (LOD), sendo que o critério de aceitação da limpeza utilizado foi de 6,4 x 10-4 mg/g para a substância ativa 1 (*); 1,0 x 10-2 mg/g para a substância ativa 2 (*); 1,0 x 10-3 mg/g para a substância ativa 3 (*) e de 10 ppm para o agente de limpeza. No ensaio de “recovery”, obtiveram-se resultados acima de 70% para todas as substâncias ativas e para o agente de limpeza nas duas pomadas. Antes de se proceder a este ensaio de “recovery”, houve a necessidade de ajustar as condições cromatográficas dos métodos analíticos de ambos os produtos e do agente de limpeza, por forma a obter-se valores da conformidade do sistema (fator de tailling e de resolução) de acordo com as especificações. A precisão dos resultados, reportada como desvio padrão relativo (RSD), deu abaixo de 2,0%, excepto nos ensaios que envolvem a substância ativa 3, cuja especificação é inferior a 10,0%. Os resultados obtidos demonstraram que os procedimentos de limpeza usados na unidade de fabrico em causa são eficazes, eliminando assim a existência de contaminação cruzada.
Resumo:
During the last years there has been an increasing concern about occupational exposure to cytostatic drugs in hospitals. The first findings on occupational exposures among hospital personnel administering chemotherapy were reported only in 1979. Since then, a great number of studies have been publishing describing possible exposure-related health effects. Consequently, rigorous guidelines for the safe handling of cancer chemotherapeutic agents were devised and the handling facilities in hospitals were extensively improved. However, recent studies developed in European countries revealed detectable amounts of several drugs in surface wipe samples. Dermal absorption after contact with contaminated surfaces can play an important role in exposure to antineoplastic drugs. Therefore, the existence of contamination in workplace surfaces implies an increased risk of exposure for health care workers. Since there is no recent report in Portugal, regarding the occupational exposure to antineoplastic drugs, a study was developed aiming to determine the 5-fluorouracil (5-FU) contamination on work surfaces of two Portuguese hospitals.