21 resultados para Sensor noise
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Low noise surfaces have been increasingly considered as a viable and cost-effective alternative to acoustical barriers. However, road planners and administrators frequently lack information on the correlation between the type of road surface and the resulting noise emission profile. To address this problem, a method to identify and classify different types of road pavements was developed, whereby near field road noise is analyzed using statistical learning methods. The vehicle rolling sound signal near the tires and close to the road surface was acquired by two microphones in a special arrangement which implements the Close-Proximity method. A set of features, characterizing the properties of the road pavement, was extracted from the corresponding sound profiles. A feature selection method was used to automatically select those that are most relevant in predicting the type of pavement, while reducing the computational cost. A set of different types of road pavement segments were tested and the performance of the classifier was evaluated. Results of pavement classification performed during a road journey are presented on a map, together with geographical data. This procedure leads to a considerable improvement in the quality of road pavement noise data, thereby increasing the accuracy of road traffic noise prediction models.
Resumo:
Esta tese tem como principal objectivo a investigação teórica e experimental do desempenho de um sensor polarimétrico baseado num cristal líquido para medição da concentração de glicose. Recentemente uma série de sensores polarimétricos baseados em cristais líquidos foram propostos na literatura e receberam considerável interesse devido as suas características únicas. De facto, em comparação com outros moduladores electro-ópticos, o cristal líquido funciona com tensões mais baixas, tem baixo consumo de energia e maior ângulo de rotação. Além disso, este tipo de polarímetro pode ter pequenas dimensões que é uma característica interessante para dispositivos portáteis e compactos. Existem por outro lado algumas desvantagens, nomeadamente o facto do desempenho do polarímetro ser fortemente dependente do tipo de cristal líquido e da tensão a ele aplicada o que coloca desafios na escolha dos parâmetros óptimos de operação. Esta tese descreve o desenvolvimento do sensor polarimétrico, incluindo a integração dos componentes de óptica e electrónica, os algoritmos de processamento de sinal e um interface gráfico que facilita a programação de diversos parâmetros de operação e a calibração do sensor. Após a optimização dos parâmetros de operação verificou-se que o dispositivo mede a concentração da glicose em amostras com uma concentração de 8 mg/ml, com uma percentagem de erro inferior a 6% e um desvio padrão de 0,008o. Os resultados foram obtidos para uma amostra com percurso óptico de apenas 1 cm.
Resumo:
A two terminal optically addressed image processing device based on two stacked sensing/switching p-i-n a-SiC:H diodes is presented. The charge packets are injected optically into the p-i-n sensing photodiode and confined at the illuminated regions changing locally the electrical field profile across the p-i-n switching diode. A red scanner is used for charge readout. The various design parameters and addressing architecture trade-offs are discussed. The influence on the transfer functions of an a-SiC:H sensing absorber optimized for red transmittance and blue collection or of a floating anode in between is analysed. Results show that the thin a-SiC:H sensing absorber confines the readout to the switching diode and filters the light allowing full colour detection at two appropriated voltages. When the floating anode is used the spectral response broadens, allowing B&W image recognition with improved light-to-dark sensitivity. A physical model supports the image and colour recognition process.
Resumo:
We report in this paper the recent advances we obtained in optimizing a color image sensor based on the laser-scanned-photodiode (LSP) technique. A novel device structure based on a a-SiC:H/a-Si:H pin/pin tandem structure has been tested for a proper color separation process that takes advantage on the different filtering properties due to the different light penetration depth at different wavelengths a-SM and a-SiC:H. While the green and the red images give, in comparison with previous tested structures, a weak response, this structure shows a very good recognition of blue color under reverse bias, leaving a good margin for future device optimization in order to achieve a complete and satisfactory RGB image mapping. Experimental results about the spectral collection efficiency are presented and discussed from the point of view of the color sensor applications. The physics behind the device functioning is explained by recurring to a numerical simulation of the internal electrical configuration of the device.
Resumo:
A visible/near-infrared optical sensor based on an ITO/SiOx/n-Si structure with internal gain is presented. This surface-barrier structure was fabricated by a low-temperature processing technique. The interface properties and carder transport were investigated from dark current-voltage and capacitance-voltage characteristics. Examination of the multiplication properties was performed under different light excitation and reverse bias conditions. The spectral and pulse response characteristics are analysed. The current amplification mechanism is interpreted by the control of electron current by the space charge of photogenerated holes near the SiOx/Si interface. The optical sensor output characteristics and some possible device applications are presented.
Resumo:
Amorphous glass/ZnO-Al/p(a-Si:H)/i(a-Si:H)/n(a-Si1-xCx:H)/Al imagers with different n-layer resistivities were produced by plasma enhanced chemical vapour deposition technique (PE-CVD). An image is projected onto the sensing element and leads to spatially confined depletion regions that can be readout by scanning the photodiode with a low-power modulated laser beam. The essence of the scheme is the analog readout, and the absence of semiconductor arrays or electrode potential manipulations to transfer the information coming from the transducer. The influence of the intensity of the optical image projected onto the sensor surface is correlated with the sensor output characteristics (sensitivity, linearity blooming, resolution and signal-to-noise ratio) are analysed for different material compositions (0.5 < x < 1). The results show that the responsivity and the spatial resolution are limited by the conductivity of the doped layers. An enhancement of one order of magnitude in the image intensity signal and on the spatial resolution are achieved at 0.2 mW cm(-2) light flux by decreasing the n-layer conductivity by the same amount. A physical model supported by electrical simulation gives insight into the image-sensing technique used.
Resumo:
We discuss the operation of a new type of optical sensor (MISCam) based on a metal-insulator-semiconductor (MIS) structure. The operation principle relies on light-induced changes of the band bending and barrier height at the interface between semiconductor and insulator. An image is obtained from the quenching of the ac signal in analogy to the principle of the laser-scanned photodiode (LSP). Lateral resolution depends on the semiconductor material chosen. We have characterised the MIS structures by C-V, I-V, and spectral response measurements testing different types of insulators like a-Si3N4, SiO2, and AlN. The presence of slow interface charges allows for image memory. Colour sensors can be realised by controlling sign and magnitude of the electric fields in the base and the interface region.
Resumo:
A presente dissertação tem como finalidade apresentar uma investigação teórica e experimental sobre um sensor polarimétrico, portátil e de baixo custo, baseado num cristal líquido para a medição da concentração de glicose existente numa amostra. Devido ao crescente número de pessoas que sofrem de Diabetes, existe grande interesse em desenvolver sensores portáteis que permitam medir a concentração de glicose de forma rápida, precisa e indolor. Dos vários métodos não invasivos existentes para a medição de concentração de glicose, o método utilizado tem como base a medição da rotação da polarização da luz. Recentemente os sensores polarimétricos baseados em cristais líquidos, têm adquirido grande ênfase devido às suas características únicas que, em comparação com outros moduladores electroópticos, funcionam com tensões mais baixas, apresentam menor consumo energético e maior ângulo de rotação. No entanto também existem diversas desvantagens, nomeadamente a falta de documentação sobre a realização de testes e resultados obtidos em sensores polarimétricos. Têm como desvantagem adicional o facto do comportamento do polarímetro ser fortemente dependente do tipo de cristal líquido e da tensão a este aplicado. A presente dissertação descreve o desenvolvimento de um sensor polarimétrico que inclui a componente óptica, a componente electrónica de detecção e acondicionamento do sinal, a comunicação sem fios com um PC, e, por fim, a componente de análise e interface com o utilizador. Neste sensor polarimétrico poderão ser efectuadas leituras de temperatura das amostras para efeitos de correcção do cálculo da concentração da glicose. O dispositivo permite ainda a gravação dos dados obtidos e identificação dos mesmos. Os resultados obtidos demonstram que o dispositivo é capaz de medir concentrações com 10mg/ml de glicose, com uma percentagem de erro de 15%, para uma amostra com um percurso óptico de apenas 1 cm.
Resumo:
Toxic amides, such as acrylamide, are potentially harmful to Human health, so there is great interest in the fabrication of compact and economical devices to measure their concentration in food products and effluents. The CHEmically Modified Field Effect Transistor (CHEMFET) based onamorphous silicon technology is a candidate for this type of application due to its low fabrication cost. In this article we have used a semi-empirical modelof the device to predict its performance in a solution of interfering ions. The actual semiconductor unit of the sensor was fabricated by the PECVD technique in the top gate configuration. The CHEMFET simulation was performed based on the experimental current voltage curves of the semiconductor unit and on an empirical model of the polymeric membrane. Results presented here are useful for selection and design of CHEMFET membranes and provide an idea of the limitations of the amorphous CHEMFET device. In addition to the economical advantage, the small size of this prototype means it is appropriate for in situ operation and integration in a sensor array.
Resumo:
A presença de sistemas eletrónicos nos veículos automóveis tem vindo a aumentar de forma considerável nos últimos 30 anos, tornando possível o aumento dos padrões de eficiência, segurança e conforto dos mesmos. Os sistemas de acionamento automático dos limpa-para-brisas, baseados em sensores de chuva óticos, têm registado um crescimento quase exponencial nos últimos 10 a 15 anos; no ano 2000, apenas 5 % dos veículos novos produzidos na Europa estavam equipados com este sistema, hoje é um equipamento amplamente difundido na oferta automóvel existente. O presente trabalho consistiu no estudo de uma solução para deteção de chuva em veículos automóveis com a aplicação de um sensor piezoelétrico, tendo em vista a obtenção de uma solução mais versátil e aplicável em vários pontos do veículo. As reduzidas dimensões, a elevada sensibilidade do sensor e a facilidade de aplicação nas superfícies de ensaio foram fatores que motivaram a escolha deste tipo de equipamento como elemento sensorial. As hipóteses definidas para o procedimento laboratorial basearam-se nas conclusões obtidas em estudos anteriormente desenvolvidos no campo dos sensores de chuva para automóveis e nas capacidades dos materiais piezoelétricos para medição de pluviosidade. Os sensores foram instalados sob as superfícies do veículo que apresentavam, simultaneamente, uma maior exposição à pluviosidade, quando este está em movimento, e um menor risco de sofrer danos. Os resultados obtidos permitiram concluir que a utilização deste tipo de sensores permite detetar elevados níveis de pluviosidade e em superfícies com considerável capacidade de deformação elástica. A sua implementação futura em veículos automóveis exige mais algum trabalho de melhoria dos processos de fixação dos sensores e do condicionamento de sinal utilizados.
Resumo:
We present new Rayleigh-wave dispersion maps of the western Iberian Peninsula for periods between 8 and 30 s, obtained from correlations of seismic ambient noise, following the recent increase in seismic broadband network density in Portugal and Spain. Group velocities have been computed for each station pair using the empirical Green's functions generated by cross-correlating one-day-length seismic ambient-noise records. The resulting high-path density allows us to obtain lateral variations of the group velocities as a function of period in cells of 0.5 degrees x 0.5 degrees with an unprecedented resolution. As a result we were able to address some of the unknowns regarding the lithospheric structure beneath SW Iberia. The dispersion maps allow the imaging of the major structural units, namely the Iberian Massif, and the Lusitanian and Algarve Meso-Cenozoic basins. The Cadiz Gulf/Gibraltar Strait area corresponds to a strong low-velocity anomaly, which can be followed to the largest period inverted, although slightly shifted to the east at longer periods. Within the Iberian Massif, second-order perturbations in the group velocities are consistent with the transitions between tectonic units composing the massif. (C) 2013 Elsevier B.V. All rights reserved.
Resumo:
Wireless local-area networks (WLANs) have been deployed as office and home communications infrastructures worldwide. The diversification of the standards, such as IEEE 802.11 series demands the design of RF front-ends. Low power consumption is one of the most important design concerns in the application of those technologies. To maintain competitive hardware costs, CMOS has been used since it is the best solution for low cost and high integration processing, allowing analog circuits to be mixed with digital ones. In the receiver chain, the low noise amplifier (LNA) is one of the most critical blocks in a transceiver design. The sensitivity is mainly determined by the LNA noise figure and gain. It interfaces with the pre-select filter and the mixer. Furthermore, since it is the first gain stage, care must be taken to provide accurate input match, low-noise figure, good linearity and a sufficient gain over a wide band of operation. Several CMOS LNAs have been reported during the last decade, showing that the most research has been done at 802.11/b and GSM standards (900-2400MHz spectrum) and more recently at 802.11/a (5GHz band). One of the more significant disadvantages of 802.11/b is that the frequency band is crowded and subject to interference from other technologies, as is 2.4GHz cordless phones and Bluetooth. As the demand for radio-frequency integrated circuits, operating at higher frequency bands, increases, the IEEE 802.11/a standard becomes a very attractive option to wireless communication system developers. This paper presents the design and implementation of a low power, low noise amplifier aimed at IEEE 802.11a for WLAN applications. It was designed to be integrated with an active balun and mixer, representing the first step toward a fully integrated monolithic WLAN receiver. All the required circuits are integrated at the same die and are powered by 1.8V supply source. Preliminary experimental results (S-parameters) are shown and promise excellent results. The LNA circuit design details are illustrated in Section 2. Spectre simulation results focused at gain, noise figure (NF) and input/output matching are presented in Section 3. Finally, conclusions and comparison with other recently reported LNAs are made in Section 4, followed by future work.
Resumo:
A pi'n/pin a-SiC:H voltage and optical bias controlled device is presented and its behavior as image and color sensor, optical amplifier and demux device is discussed. The design and the light source properties are correlated with the sensor output characteristics. Different readout techniques are used. When a low power monochromatic scanner readout the generated carriers the transducer recognizes a color pattern projected on it acting as a direct color and image sensor. Scan speeds up to 10(4) lines per second are achieved without degradation in the resolution. If the photocurrent generated by different monochromatic pulsed channels is readout directly, the information is demultiplexed. Results show that it is possible to decode the information from three simultaneous color channels without bit errors at bit rates per channel higher than 4000 bps. Finally, when triggered by light of appropriated wavelength, it can amplify or suppress the generated photocurrent working as an optical amplifier (C) 2009 Published by Elsevier Ltd.
Resumo:
Chapter in Book Proceedings with Peer Review First Iberian Conference, IbPRIA 2003, Puerto de Andratx, Mallorca, Spain, JUne 4-6, 2003. Proceedings
Resumo:
Electrocardiography (ECG) biometrics is emerging as a viable biometric trait. Recent developments at the sensor level have shown the feasibility of performing signal acquisition at the fingers and hand palms, using one-lead sensor technology and dry electrodes. These new locations lead to ECG signals with lower signal to noise ratio and more prone to noise artifacts; the heart rate variability is another of the major challenges of this biometric trait. In this paper we propose a novel approach to ECG biometrics, with the purpose of reducing the computational complexity and increasing the robustness of the recognition process enabling the fusion of information across sessions. Our approach is based on clustering, grouping individual heartbeats based on their morphology. We study several methods to perform automatic template selection and account for variations observed in a person's biometric data. This approach allows the identification of different template groupings, taking into account the heart rate variability, and the removal of outliers due to noise artifacts. Experimental evaluation on real world data demonstrates the advantages of our approach.