6 resultados para Research Subject Categories::MEDICINE::Surgery::Oncology

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to increased interest in in vivo small animal imaging. Small animal imaging has been applied frequently to the imaging of small animals (mice and rats), which are ubiquitous in modeling human diseases and testing treatments. The use of PET in small animals allows the use of subjects as their own control, reducing the interanimal variability. This allows performing longitudinal studies on the same animal and improves the accuracy of biological models. However, small animal PET still suffers from several limitations. The amounts of radiotracers needed, limited scanner sensitivity, image resolution and image quantification issues, all could clearly benefit from additional research. Because nuclear medicine imaging deals with radioactive decay, the emission of radiation energy through photons and particles alongside with the detection of these quanta and particles in different materials make Monte Carlo method an important simulation tool in both nuclear medicine research and clinical practice. In order to optimize the quantitative use of PET in clinical practice, data- and image-processing methods are also a field of intense interest and development. The evaluation of such methods often relies on the use of simulated data and images since these offer control of the ground truth. Monte Carlo simulations are widely used for PET simulation since they take into account all the random processes involved in PET imaging, from the emission of the positron to the detection of the photons by the detectors. Simulation techniques have become an importance and indispensable complement to a wide range of problems that could not be addressed by experimental or analytical approaches.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O trabalho descrito nesta dissertação de mestrado foca-se em geral na investigação de antenas impressas. São apresentados conceitos básicos, em conjunto com alguns exemplos desenvolvidos. No entanto, o principal foco prende-se com técnicas de miniaturização e reconfigurabilidade de antenas. A miniaturização de antenas é um tema de investigação de longa data, no entanto, novas técnicas e soluções são apresentadas regularmente. Nesta tese, é aplicada uma técnica recente, baseada na introdução de indutores encapsulados no elemento ressonante de uma antena, que permite miniaturizar um monopólio impresso com uma frequência de ressonância de 2.5 GHz. Outro assunto abordado neste trabalho é a reconfigurabilidade de antenas. Algumas das técnicas mais comuns na investigação actual são apresentadas e debatidas. Uma solução com recurso a díodos PIN é usada para estudar esta capacidade. Os conceitos e características deste tipo de componentes são apresentadas sendo feito o desenho e fabrico de um possível monopólio impresso reconfigurável para operação em dupla banda. Por fim, são combinadas as técnicas de miniaturização com inductor encapsulado e reconfigurabilidade através de díodos PIN, por forma a projectar uma antena reconfigurável muito pequena, para operação em duas bandas distintas. Os resultados são discutidos e com base nestes, algumas possíveis otimizações são propostas. The work reported in this dissertation is focused in the printed antenna research. Basic concepts of printed antennas are presented, along with a few examples that were developed. The main focus however, is around miniaturization and reconfigurability of antennas. Antenna miniaturization is a long time research subject, however, new techniques and solutions are presented everyday. In this thesis, a recent technique based on the introduction of chip inductors in the resonating element of a printed antenna is used in order to miniaturize a monopole with a resonating frequency at 2.5 GHz. Another issue approached in this work is antenna reconfigurability. Some common techniques used in antenna reconfiguration are presented and debated. A solution with PIN diodes is used to study this capability. The concepts and characteristics of this type of components are presented and an example of a reconfigurable printed monopole for dual-band operation is designed and fabricated. At last, miniaturization with chip inductor and reconfigurability through PIN diodes are used together to create a very small antenna for dual-band operation. The simulated and measured results are discussed and upon these, some possible optimizations are proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivo: identificar fontes de estresse e estratégias de coping em enfermeiros que exercem funções em três Serviços de Oncologia de Cirurgia Cabeça e Pescoço, de três hospitais centrais de Portugal. Método: estudo transversal, de carácter descritivo e exploratório, cuja amostra foi constituída pelos 96 enfermeiros dos três serviços. Na recolha de dados, foram utilizados: Questionário Sociodemográfico, Questionário de Saúde Geral-12, Inventário de Estressores Ocupacionais e Brief COPE. Resultados: verificaram-se níveis razoáveis de saúde geral. Os estressores mais referidos foram: sobrecarga de trabalho, baixa remuneração salarial, espaço físico onde se desenvolve a profissão, situações emocionalmente perturbadoras e falta de reconhecimento da profissão. As estratégias de coping mais utilizadas foram: planeamento, coping ativo, aceitação e autodistração. Conclusão: os estressores identificados relacionam-se principalmente a aspetos organizacionais e condições de trabalho, e as estratégias de coping escolhidas estão direcionadas para a resolução de problemas e melhoria do bemestar dos enfermeiros. Percentagem expressiva de enfermeiros apresentou níveis elevados de pressão e emoções deprimidas. Os resultados apresentados corroboram estudos anteriores que alertam para a importância do desenvolvimento de estratégias de prevenção dos níveis de estresse.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mestrado em Fisioterapia

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction - European nuclear medicine technologist’s education is delivered by Higher Education Institutions and students obtain a grade of Bachelor of Sciences (BSc), during which they are initiated to research during their studies. Once BSc nuclear medicine technologists are in professional practice, they have very few opportunities to develop a real research experience and they rather become passive users than active contributors the growth of scientific knowledge in nuclear medicine. Aim - To describe and discuss an innovative educational and professional experience aimed in strengthen research knowledge, skills and competencies of former nuclear medicine technologists student in the context of an international mobility stay.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Immunohistochemistry (IHC) is the group of techniques that use antibodies as specific reagents to identify and demonstrate several cell and tissue components that are antigens. This linking allows locating and identifying the in situ presence of various substances by means of color that is associated with the formed antigen-antibody complexes. The practical value of this biotechnology area, widely used in Pathology and Oncology, in diagnostic, prognostic, theranostic and research context, results from the possibility of combining a colour marker with an antibody without causing any damage to specific binding established between antibody and antigen. This provides the microscopic observation of the target locations where the antibody and hence the antigen are present. IHC is presented as a powerful means for identification of several cellular and tissue structures that can be associated with pathologies, and of the consequences, at functional and morphological level, of these same elements action.