6 resultados para Research -- Evaluation

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The pressurization of hydraulic systems containing entrapped air is considered a critical condition for the infrastructure's security due to transient pressure variations often occurred. The objective of the present study is the computational evaluation of trends observed in variation of maximum surge pressure resulting from rapid pressurizations. The comparison of the results with those obtained in previous studies is also undertaken. A brief state of art in this domain is presented. This research work is applied to an experimental system having entrapped air in the top of a vertical pipe section. The evaluation is developed through the elastic model based on the method of characteristics, considering a moving liquid boundary, with the results being compared with those achieved with the rigid liquid column model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The pressurization of hydraulic systems containing entrapped air is considered a critical condition for the infrastructure's security due to transient pressure variations often occurred. The objective of the present study is the computational evaluation of trends observed in variation of maximum surge pressure resulting from rapid pressurizations. The comparison of the results with those obtained in previous studies is also undertaken. A brief state of art in this domain is presented. This research work is applied to an experimental system having entrapped air in the top of a vertical pipe section. The evaluation is developed through the elastic model based on the method of characteristics, considering a moving liquid boundary, with the results being compared with those achieved with the rigid liquid column model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to increased interest in in vivo small animal imaging. Small animal imaging has been applied frequently to the imaging of small animals (mice and rats), which are ubiquitous in modeling human diseases and testing treatments. The use of PET in small animals allows the use of subjects as their own control, reducing the interanimal variability. This allows performing longitudinal studies on the same animal and improves the accuracy of biological models. However, small animal PET still suffers from several limitations. The amounts of radiotracers needed, limited scanner sensitivity, image resolution and image quantification issues, all could clearly benefit from additional research. Because nuclear medicine imaging deals with radioactive decay, the emission of radiation energy through photons and particles alongside with the detection of these quanta and particles in different materials make Monte Carlo method an important simulation tool in both nuclear medicine research and clinical practice. In order to optimize the quantitative use of PET in clinical practice, data- and image-processing methods are also a field of intense interest and development. The evaluation of such methods often relies on the use of simulated data and images since these offer control of the ground truth. Monte Carlo simulations are widely used for PET simulation since they take into account all the random processes involved in PET imaging, from the emission of the positron to the detection of the photons by the detectors. Simulation techniques have become an importance and indispensable complement to a wide range of problems that could not be addressed by experimental or analytical approaches.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Micro-generation is the small scale production of heat and/or electricity from a low carbon source and can be a powerful driver for carbon reduction, behavior change, security of supply and economic value. The energy conversion technologies can include photovoltaic panels, micro combined heat and power, micro wind, heat pumps, solar thermal systems, fuel cells and micro hydro schemes. In this paper, a small research of the availability of the conversion apparatus and the prices for the micro wind turbines and photovoltaic systems is made and a comparison between these two technologies is performed in terms of the availability of the resource and costs. An analysis of the new legal framework published in Portugal is done to realize if the incentives to individualspsila investment in sustainable and local energy production is worth for their point of view. An economic evaluation for these alternatives, accounting with the governmentpsilas incentives should lead, in most cases, into attractive return rates for the investment. Apart from the attractiveness of the investment there are though other aspects that should be taken into account and those are the benefits that these choices have to us all. The idea is that micro-generation will not only make a significant direct contribution to carbon reduction targets, it will also trigger a multiplier effect in behavior change by engaging hearts and minds, and providing more efficient use of energy by householders. The diversified profile of power generation by micro-generators, both in terms of location and timing, should reduce the impact of intermittency or plant failures with significant gains for security of supply.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The purpose of this review is to gather and analyse current research publications to evaluate Sinogram-Affirmed Iterative Reconstruction (SAFIRE). The aim of this review is to investigate whether this algorithm is capable of reducing the dose delivered during CT imaging while maintaining image quality. Recent research shows that children have a greater risk per unit dose due to increased radiosensitivity and longer life expectancies, which means it is particularly important to reduce the radiation dose received by children. Discussion: Recent publications suggest that SAFIRE is capable of reducing image noise in CT images, thereby enabling the potential to reduce dose. Some publications suggest a decrease in dose, by up to 64% compared to filtered back projection, can be accomplished without a change in image quality. However, literature suggests that using a higher SAFIRE strength may alter the image texture, creating an overly ‘smoothed’ image that lacks contrast. Some literature reports SAFIRE gives decreased low contrast detectability as well as spatial resolution. Publications tend to agree that SAFIRE strength three is optimal for an acceptable level of visual image quality, but more research is required. The importance of creating a balance between dose reduction and image quality is stressed. In this literature review most of the publications were completed using adults or phantoms, and a distinct lack of literature for paediatric patients is noted. Conclusion: It is necessary to find an optimal way to balance dose reduction and image quality. More research relating to SAFIRE and paediatric patients is required to fully investigate dose reduction potential in this population, for a range of different SAFIRE strengths.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background - Medical image perception research relies on visual data to study the diagnostic relationship between observers and medical images. A consistent method to assess visual function for participants in medical imaging research has not been developed and represents a significant gap in existing research. Methods - Three visual assessment factors appropriate to observer studies were identified: visual acuity, contrast sensitivity, and stereopsis. A test was designed for each, and 30 radiography observers (mean age 31.6 years) participated in each test. Results - Mean binocular visual acuity for distance was 20/14 for all observers. The difference between observers who did and did not use corrective lenses was not statistically significant (P = .12). All subjects had a normal value for near visual acuity and stereoacuity. Contrast sensitivity was better than population norms. Conclusion - All observers had normal visual function and could participate in medical imaging visual analysis studies. Protocols of evaluation and populations norms are provided. Further studies are necessary to understand fully the relationship between visual performance on tests and diagnostic accuracy in practice.