7 resultados para Reproducibility of Results

em Repositório Científico do Instituto Politécnico de Lisboa - Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we present the results of mammography quality control tests related to the work with Portuguese mammography equipment, either in conventional or in digital mammography computed radiography, showing the main differences in the tested equipments. Quality control in mammography is a very special area of quality control in radiology, which demands relatively high knowledge on physics. Digital imaging is changing the standards of the radiographic imaging. Regarding mammography, this is yet a controversial issue owing to some limitations of the digital detectors, like the resolution for instance. A complete set of results regarding radiation protection of the patients submitted to mammography diagnosis is presented. A discussion of the quality image parameters and its interpretation in conventional and digital mammography is presented. In conclusion, we present a sample of results that can be considered as characteristics of mammography equipment in Portugal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents for the first time a systematic study on the optimization of the electrochemical cleaning time of a mercury film when it is used as a working electrode material in the analysis of toxic metals, such as Pb2+, used as model metal, in real samples by SWASV. The optimization study for the film’s cleaning time aimed at attaining a Pb2+ minimum value in the film after the re-oxidation step of the pre-concentrated metal, given the impossibility of complete removal of traces of the electroactive species from the film. This value was kept constant in each concentration range studied ensuring thus that all assays were performed in initial identical conditions. An assay performed on a synthetic sample was taken as reference. In it, given the absence of matrix effects, and after the electrochemical cleaning step, a direct proportionality was observed between the residual amounts of Pb2+ in the film (which for the cleaning time used was never completely removed) and Pb2+ concentration in the solution. This fact determined a high correlation between Pb2+ peak current and Pb2+ concentration which was not observed when real samples (tree leaves) were analyzed. This behavior may result from the presence of the interfering surfactants always present in real samples of complex matrix. Cleaning time optimization was performed for the following Pb2+ concentration ranges in the real samples of complex matrix: 0.006-0.020, 0.020-0.080, 0.060-0.200 and 0.100-0.600 ppb. As expected, in order to obtain identical levels of film’s cleaning efficiency, the need for longer cleaning times has been observed for higher concentrations. The optimized cleaning times for the concentration ranges under study were 120, 150, 180 e 300 s, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Human virtual phantoms are being widely used to simulate and characterize the behavior of different organs, either in diagnosis stages but also to enable foreseeing the therapeutic effects obtained on a certain patient. In the present work a typical patient’s heart was simulated using XCAT2©, considering the possibility of a lesion and/or anatomical alteration being affecting the myocardium. These simulated images, were then used to carry out a set of parametric studies using Matlab©. Although performed in controlled sceneries, these studies are very important to understand and characterize the performance of the methodologies used, as well as to determine to what extent the relations between the perturbation introduced at the myocardium and the resulting simulated images can be considered conclusive.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pre-operative diffusion tensor (DT) tractography is currently employed in our institutions. We use it to predict the course of the facial nerve (FN) in the vicinity of vestibular schwannomas (VS) of the cerebellopontine angle (CPA). In this study we were interested to assess the inter-observer reproducibility of this method. Two Neuroradiologists (PMGP and TT) determined independently the location of the FN by tractography and compared the results with in-vivo findings of microsurgery of VS.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introdução – Numa era em que os tratamentos de Radioterapia Externa (RTE) exigem cada vez mais precisão, a utilização de imagem médica permitirá medir, quantificar e avaliar o impacto do erro provocado pela execução do tratamento ou pelos movimentos dos órgãos. Objetivo – Analisar os dados existentes na literatura acerca de desvios de posicionamento (DP) em patologias de cabeça e pescoço (CP) e próstata, medidos com Cone Beam Computed Tomography (CBCT) ou Electronic Portal Image Device (EPID). Metodologia – Para esta revisão da literatura foram pesquisados artigos recorrendo às bases de dados MEDLINE/PubMed e b-on. Foram incluídos artigos que reportassem DP em patologias CP e próstata medidos através de CBCT e EPID. Seguidamente foram aplicados critérios de validação, que permitiram a seleção dos estudos. Resultados – Após a análise de 35 artigos foram incluídos 13 estudos e validados 9 estudos. Para tumores CP, a média (μ) dos DP encontra-se entre 0,0 e 1,2mm, com um desvio padrão (σ) máximo de 1,3mm. Para patologias de próstata observa-se μDP compreendido entre 0,0 e 7,1mm, com σ máximo de 7,5mm. Discussão/Conclusão – Os DP em patologias CP são atribuídos, maioritariamente, aos efeitos secundários da RTE, como mucosite e dor, que afetam a deglutição e conduzem ao emagrecimento, contribuindo para a instabilidade da posição do doente durante o tratamento, aumentando as incertezas de posicionamento. Os movimentos da próstata devem-se principalmente às variações de preenchimento vesical, retal e gás intestinal. O desconhecimento dos DP afeta negativamente a precisão da RTE. É importante detetá-los e quantificá-los para calcular margens adequadas e a magnitude dos erros, aumentando a precisão da administração de RTE, incluindo o aumento da segurança do doente. - ABSTRACT - Background and Purpose – In an era where precision is an increasing necessity in external radiotherapy (RT), modern medical imaging techniques provide means for measuring, quantifying and evaluating the impact of treatment execution and movement error. The aim of this paper is to review the current literature on the quantification of setup deviations (SD) in patients with head and neck (H&N) or prostate tumors, using Cone Beam Computed Tomography (CBCT) or Electronic Portal Image Device (EPID). Methods – According to the study protocol, MEDLINE/PubMed and b-on databases were searched for trials, which were analyzed using selection criteria based on the quality of the articles. Results – After assessment of 35 papers, 13 studies were included in this analysis and nine were authenticated (6 for prostate and 3 for H&N tumors). The SD in the treatment of H&N cancer patients is in the interval of 0.1 to 1.2mm, whereas in prostate cancer this interval is 0.0 to 7.1mm. Discussion – The reproducibility of patient positioning is the biggest barrier for higher precision in RT, which is affected by geometrical uncertainty, positioning errors and inter or intra-fraction organ movement. There are random and systematic errors associated to patient positioning, introduced since the treatment planning phase or through physiological organ movement. Conclusion – The H&N SD are mostly assigned to the Radiotherapy adverse effects, like mucositis and pain, which affect swallowing and decrease secretions, contributing for the instability of patient positioning during RT treatment and increasing positioning uncertainties. Prostate motion is mainly related to the variation in bladder and rectal filling. Ignoring SD affects negatively the accuracy of RT. Therefore, detection and quantification of SD is crucial in order to calculate appropriate margins, the magnitude of error and to improve accuracy in RTE and patient safety.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Following work on tantalum and chromium implanted flat M50 steel substrates, this work reports on the electrochemical behaviour of M50 steel implanted with tantalum and chromium and the effect of the angle of incidence. Proposed optimum doses for resistance to chloride attack were based on the interpretation of results obtained during long-term and accelerated electrochemical testing. After dose optimization from the corrosion viewpoint, substrates were implanted at different angles of incidence (15°, 30°, 45°, 60°, 75°, 90°) and their susceptibility to localized corrosion assessed using open-circuit measurements, step by step polarization and cyclic voltammetry at several scan rates (5–50 mV s-1). Results showed, for tantalum implanted samples, an ennoblement of the pitting potential of approximately 0.5 V for an angle of incidence of 90°. A retained dose of 5 × 1016 atoms cm-2 was found by depth profiling with Rutherford backscattering spectrometry. The retained dose decreases rapidly with angle of incidence. The breakdown potential varies roughly linearly with the angle of incidence up to 30° falling fast to reach -0.1 V (vs. a saturated calomel electrode (SCE)) for 15°. Chromium was found to behave differently. Maximum corrosion resistance was found for angles of 45°–60° according to current densities and breakdown potentials. Cr+ depth profiles ((p,γ) resonance broadening method), showed that retained doses up to an angle of 60° did not change much from the implanted dose at 90°, 2 × 1017 Cr atoms cm-2. The retained implantation dose for tantalum and chromium was found to follow a (cos θ)8/3 dependence where θ is the angle between the sample normal and the beam direction.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Brain dopamine transporters imaging by Single Emission Tomography (SPECT) with 123I-FP-CIT (DaTScanTM) has become an important tool in the diagnosis and evaluation of Parkinson syndromes.This diagnostic method allows the visualization of a portion of the striatum – where healthy pattern resemble two symmetric commas - allowing the evaluation of dopamine presynaptic system, in which dopamine transporters are responsible for dopamine release into the synaptic cleft, and their reabsorption into the nigrostriatal nerve terminals, in order to be stored or degraded. In daily practice for assessment of DaTScan TM, it is common to rely only on visual assessment for diagnosis. However, this process is complex and subjective as it depends on the observer’s experience and it is associated with high variability intra and inter observer. Studies have shown that semiquantification can improve the diagnosis of Parkinson syndromes. For semiquantification, analysis methods of image segmentation using regions of interest (ROI) are necessary. ROIs are drawn, in specific - striatum - and in nonspecific – background – uptake areas. Subsequently, specific binding ratios are calculated. Low adherence of semiquantification for diagnosis of Parkinson syndromes is related, not only with the associated time spent, but also with the need of an adapted database of reference values for the population concerned, as well as, the examination of each service protocol. Studies have concluded, that this process increases the reproducibility of semiquantification. The aim of this investigation was to create and validate a database of healthy controls for Dopamine transporters with DaTScanTM named DBRV. The created database has been adapted to the Nuclear Medicine Department’s protocol, and the population of Infanta Cristina’s Hospital located in Badajoz, Spain.