8 resultados para Radioactive Iodine
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Naturally Occurring Radioactive Materials (NORM) are materials that are found naturally in the environment and contain radioactive isotopes that can cause negative effects on the health of workers who manipulate them. Present in underground work like mining and tunnel construction in granite zones, these materials are difficult to identify and characterize without appropriate equipment for risk evaluation. The assessing methods were exemplified with a case study applied to the handling and processing of phosphoric rock where one found significant amounts of radioactive isotopes and consequently elevated radon concentrations in enclosed spaces containing these materials. © 2015 Taylor & Francis Group, London.
Resumo:
The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to increased interest in in vivo small animal imaging. Small animal imaging has been applied frequently to the imaging of small animals (mice and rats), which are ubiquitous in modeling human diseases and testing treatments. The use of PET in small animals allows the use of subjects as their own control, reducing the interanimal variability. This allows performing longitudinal studies on the same animal and improves the accuracy of biological models. However, small animal PET still suffers from several limitations. The amounts of radiotracers needed, limited scanner sensitivity, image resolution and image quantification issues, all could clearly benefit from additional research. Because nuclear medicine imaging deals with radioactive decay, the emission of radiation energy through photons and particles alongside with the detection of these quanta and particles in different materials make Monte Carlo method an important simulation tool in both nuclear medicine research and clinical practice. In order to optimize the quantitative use of PET in clinical practice, data- and image-processing methods are also a field of intense interest and development. The evaluation of such methods often relies on the use of simulated data and images since these offer control of the ground truth. Monte Carlo simulations are widely used for PET simulation since they take into account all the random processes involved in PET imaging, from the emission of the positron to the detection of the photons by the detectors. Simulation techniques have become an importance and indispensable complement to a wide range of problems that could not be addressed by experimental or analytical approaches.
Resumo:
Introdução – No caso de uma eventual contaminação radioativa esta deve ser quantificada, pelo que é necessário garantir que as condições de funcionamento de um monitor de contaminação de superfícies se encontrem adequadamente caracterizadas, através da determinação da sua eficiência de deteção. Este estudo tem como objetivo determinar a eficiência de deteção de um monitor de contaminação e analisar a influência da distância e da atividade. Metodologia – O monitor de contaminação Thermo Mini 900E e as fontes radioativas planas de referência de Carbono – 14 (C-14), Césio – 137 (Cs-137), Estrôncio – 90 (Sr-90), Cloro – 36 (Cl-36) e Amerício – 241 (Am-241) com débito de emissão superficial rastreável ao Physikalish Technischen Bundesanstalt (PTB) foram utilizadas. Fontes de Sr-90 e C-14 com dois débitos de emissão distintos para cada e distâncias de 1 a 20mm foram usados para estudar a sua influência na eficiência de deteção. Resultados – Verificou-se que as fontes radioativas emissoras de partículas de maior energia apresentam uma maior eficiência de deteção e que esta diminui com o aumento da distância do detetor à fonte, sendo que os radioisótopos de maior energia apresentam um decréscimo na eficiência de 15% ao longo de 20mm, enquanto os radioisótopos de menor energia apresentam um decréscimo de 10%. Não se verificou uma influência expressiva do débito de emissão na eficiência de deteção deste monitor de contaminação. Conclusão – A eficiência de deteção de um monitor de contaminação portátil é dependente da distância deste à contaminação bem como do tipo de radiação emitida e energia dos radioisótopos presentes na contaminação. - ABSTRACT - Introduction – A radioactive contamination needs to be quantified in case it eventually occurs. Therefore it is necessary to ensure that the operating conditions of a surface contamination monitor are characterized by determining its detection efficiency. This experimental study aims to determine the detection efficiency of a contamination monitor and evaluate the distance and surface emission rate influence on the detection efficiency. Methodology – A contamination monitor Thermo Mini 900E was tested with reference radiation sources of Carbon – 14 (C-14), Cesium – 137 (Cs-137), Strontium – 90 (Sr-90), Chlorine – 36 (Cl-36) and Americium – 241 (Am-241) with its emission rate traced to the Physikalish Technischen Bundesanstalt (PTB). Sources of Sr-90 and C-14 with two different emission rates for each one and distances of 1 to 20mm were used to study its influence in the detection efficiency. Results – With the increasing of distance, the detection efficiency decreases. The most energetic radiation sources have higher detection efficiency, boasting a 15% decrease over 20mm whereas the sources bearing a smaller efficiency decrease 10%. No influence of the surface emission rate in the detection efficiency was verified. Conclusion – Thus, it is concluded that the detection efficiency of a contamination monitor is dependent of the distance between it and the contamination as well as the type and energy of the radioisotopes present in the contamination.
Resumo:
Mestrado em Medicina Nuclear - Área de especialização: Radiofarmácia.
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Automação e Electrónica Industrial
Resumo:
Introdução e Objetivos – Os campos eletromagnéticos estão presentes naturalmente no Universo. Há alguns anos, os valores referentes a campos eletromagnéticos eram relativamente constantes. Com o desenvolvimento da tecnologia, a exposição a novas fontes de radiação eletromagnética aumentou. Desta forma, é normal que a preocupação pública, principalmente sobre os potenciais riscos para a saúde provenientes dos campos eletromagnéticos, tenha aumentado. O objetivo deste trabalho foi conhecer e analisar a preocupação e a perceção dos indivíduos sobre a radiação eletromagnética, tendo por base que um dos principais fatores para a adoção de medidas de precaução é o modo como o risco é percecionado pelo indivíduo. Metodologia – Trata-se de um estudo do tipo descritivo, de natureza quantitativa. A amostra, composta por 320 indivíduos, é de natureza não probabilística de conveniência. Resultados – Verificou-se que os inquiridos se manifestam “pouco preocupados” relativamente à exposição aos campos eletromagnéticos, desconhecem as fontes emissoras de radiação eletromagnética presentes no seu quotidiano e não tomam precauções relativamente à exposição a campos eletromagnéticos. Conclusões – Os indivíduos mostram imaturidade conscienciosa em relação à problemática da radiação eletromagnética, em parte justificada pela ausência de mecanismos sensoriais que a permitam detetar. A aposta na educação e sensibilização pode garantir um futuro com melhor qualidade de vida. É importante reunir esforços de várias entidades (saúde, meios de comunicação social e educação). A escola, através das crianças e jovens, constitui um meio privilegiado para a transmissão de informação.
Fisioterapia cardiorrespiratória em pacientes vítimas de queimaduras: projeto de intervenção precoce
Resumo:
Mestrado em Fisioterapia
Resumo:
Present study develops and implements a specific methodology for the assessment of health risks derived from occupational exposure of workers to ionizing radiation in the fertilizer manufacturing industry. Negative effects on the health of exposed workers are identified, according to the types and levels of exposure to which they are subject, namely an increase of the risk of cancer even with long term exposure to low level radiation. Ionizing radiation types, methods and measuring equipment are characterized. The methodology developed in a case study of a phosphate fertilizer industry is applied, assessing occupational exposure to ionizing radiation caused by external radiation and the inhalation of radioactive gases and dust.