38 resultados para RF Magnetron Sputtering
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Tin doped indium oxide (ITO) films were deposited on glass substrates by rf reactive magnetron sputtering using a metallic alloy target (In-Sn, 90-10). The post-deposition annealing has been done for ITO films in air and the effect of annealing temperature on the electrical, optical and structural properties of ITO films was studied. It has been found that the increase of the annealing temperature will improve the film electrical properties. The resistivity of as deposited film is about 1.3 x 10(-1) Omega*cm and decreases down to 6.9 x 10(-3) Omega*cm as the annealing temperature is increased up to 500 degrees C. In addition, the annealing will also increase the film surface roughness which can improve the efficiency of amorphous silicon solar cells by increasing the amount of light trapping.
Resumo:
Thin films of TiO2 were doped with Au by ion implantation and in situ during the deposition. The films were grown by reactive magnetron sputtering and deposited in silicon and glass substrates at a temperature around 150 degrees C. The undoped films were implanted with Au fiuences in the range of 5 x 10(15) Au/cm(2)-1 x 10(17) Au/cm(2) with a energy of 150 keV. At a fluence of 5 x 10(16) Au/cm(2) the formation of Au nanoclusters in the films is observed during the implantation at room temperature. The clustering process starts to occur during the implantation where XRD estimates the presence of 3-5 nm precipitates. After annealing in a reducing atmosphere, the small precipitates coalesce into larger ones following an Ostwald ripening mechanism. In situ XRD studies reveal that Au atoms start to coalesce at 350 degrees C, reaching the precipitates dimensions larger than 40 nm at 600 degrees C. Annealing above 700 degrees C promotes drastic changes in the Au profile of in situ doped films with the formation of two Au rich regions at the interface and surface respectively. The optical properties reveal the presence of a broad band centered at 550 nm related to the plasmon resonance of gold particles visible in AFM maps. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Amorphous and crystalline sputtered boron carbide thin films have a very high hardness even surpassing that of bulk crystalline boron carbide (≈41 GPa). However, magnetron sputtered B-C films have high friction coefficients (C.o.F) which limit their industrial application. Nanopatterning of materials surfaces has been proposed as a solution to decrease the C.o.F. The contact area of the nanopatterned surfaces is decreased due to the nanometre size of the asperities which results in a significant reduction of adhesion and friction. In the present work, the surface of amorphous and polycrystalline B-C thin films deposited by magnetron sputtering was nanopatterned using infrared femtosecond laser radiation. Successive parallel laser tracks 10 μm apart were overlapped in order to obtain a processed area of about 3 mm2. Sinusoidal-like undulations with the same spatial period as the laser tracks were formed on the surface of the amorphous boron carbide films after laser processing. The undulations amplitude increases with increasing laser fluence. The formation of undulations with a 10 μm period was also observed on the surface of the crystalline boron carbide film processed with a pulse energy of 72 μJ. The amplitude of the undulations is about 10 times higher than in the amorphous films processed at the same pulse energy due to the higher roughness of the films and consequent increase in laser radiation absorption. LIPSS formation on the surface of the films was achieved for the three B-C films under study. However, LIPSS are formed under different circumstances. Processing of the amorphous films at low fluence (72 μJ) results in LIPSS formation only on localized spots on the film surface. LIPSS formation was also observed on the top of the undulations formed after laser processing with 78 μJ of the amorphous film deposited at 800 °C. Finally, large-area homogeneous LIPSS coverage of the boron carbide crystalline films surface was achieved within a large range of laser fluences although holes are also formed at higher laser fluences.
Resumo:
This article presents the design and test of a receiver front end aimed at LMDS applications at 28.5 GHz. It presents a system-level design after which the receiver was designed. The receiver comprises an LNA, quadrature mixer and quadrature local oscillator. Experimental results at 24 GHz center frequency show a conversion voltage gain of 15 dB and conversion noise figure of 14 5 dB. The receiver operates from a 2 5 V power supply with a total current consumption of 31 mA.
Resumo:
Diatermia é um tipo de emissão eletromagnética que consta de carga elétrica e magnética. A importância desta energia está em que transforma a radiação eletromagnética em energia térmica devido à resistência dos tecidos. O efeito térmico depende do tamanho e forma do electrodo, tipo de emissão e do nível de energia aplicado. A eletroterapia de Alta Frequência pode definir-se como o uso terapêutico de oscilações eletromagnéticas, com frequências superiores a 300000 Hz. A energia eletromagnética é convertida em energia nos tecidos.
Resumo:
O objectivo deste trabalho consiste na construção de um protótipo de um aparelho para medir a componente real e imaginária da impedância de dispositivos em RF. Inicialmente é efectuado um estudo do significado de impedância e de outros conceitos a ela associados. Assim como dos vários métodos existentes para a sua medição. Com base nesse estudo é adoptado um tipo de medidor para implementação. Após a implementação do protótipo são efectuados testes de modo a caracterizar o desempenho do mesmo. O protótipo possui um microcontrolador que permite gerir os vários módulos que o compõem e é também o responsável pela comunicação com o utilizador a nível local e com um PC ou terminal remoto. Os dados das medições são enviados para o PC através de uma ligação série para posterior tratamento dos mesmos através de software desenvolvido em ambiente Matlab. Pretende-se também demonstrar que é possível actualmente construir um aparelho de custo moderado mas cujas prestações, em certas aplicações, são adequadas, evitando assim a necessidade de utilizar outros aparelhos de laboratório, normalmente utilizados para este fim, cujo custo é cem vezes superior.
Resumo:
To determine self-consistently the time evolution of particle size and their number density in situ multi-angle polarization-sensitive laser light scattering was used. Cross-polarization intensities (incident and scattered light intensities with opposite polarization) measured at 135 degrees and ex situ transmission electronic microscopy analysis demonstrate the existence of nonspherical agglomerates during the early phase of agglomeration. Later in the particle time development both techniques reveal spherical particles again. The presence of strong cross-polarization intensities is accompanied by low-frequency instabilities detected on the scattered light intensities and plasma emission. It is found that the particle radius and particle number density during the agglomeration phase can be well described by the Brownian free molecule coagulation model. Application of this neutral particle coagulation model is justified by calculation of the particle charge whereby it is shown that particles of a few tens of nanometer can be considered as neutral under our experimental conditions. The measured particle dispersion can be well described by a Brownian free molecule coagulation model including a log-normal particle size distribution. (C) 1996 American Institute of Physics.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Electrónica e Telecomunicações
Resumo:
Considering that recent european high-speed railway system has a traction power system of kV 50 Hz, which causes electromagnetic emission for the outside world, it is important to dimension the railway system emissions, using a frequency/distance dependent propagation model. This paper presents an enhanced theoretical model for VLF to UHF propagation, railway system oriented. It introduces the near field approach (crucial in low frequency propagation) and also considers the source characteristics and type of measuring antenna. Simulations are presented, and comparisons are set with earlier far field models. Using the developed model, a real case study was performed in partnership with Refer Telecom (portuguese telecom operator for railways). The new propagation model was used in order to predict the future high-speed railway electromagnetic emissions in the Lisbon north track. The results show the model's prediction capabilities and also its applicability to realistic scenarios.
Resumo:
Radio frequency (RF) energy harvesting is an emerging technology that will enable to drive the next generation of wireless sensor networks (WSNs) without the need of using batteries. In this paper, we present RF energy harvesting circuits specifically developed for GSM bands (900/1800) and a wearable dual-band antenna suitable for possible implementation within clothes for body worn applications. Besides, we address the development and experimental characterization of three different prototypes of a five-stage Dickson voltage multiplier (with match impedance circuit) responsible for harvesting the RF energy. Different printed circuit board (PCB) fabrication techniques to produce the prototypes result in different values of conversion efficiency. Therefore, we conclude that if the PCB fabrication is achieved by means of a rigorous control in the photo-positive method and chemical bath procedure applied to the PCB it allows for attaining better values for the conversion efficiency. All three prototypes (1, 2 and 3) can power supply the IRIS sensor node for RF received powers of -4 dBm, -6 dBm and -5 dBm, and conversion efficiencies of 20, 32 and 26%, respectively. © 2014 IEEE.
Resumo:
The erosion depth profile of planar targets in balanced and unbalanced magnetron cathodes with cylindrical symmetry is measured along the target radius. The magnetic fields have rotational symmetry. The horizontal and vertical components of the magnetic field B are measured at points above the cathode target with z = 2 x 10(-3) m. The experimental data reveal that the target erosion depth profile is a function of the angle. made by B with a horizontal line defined by z = 2 x 10(-3) m. To explain this dependence a simplified model of the discharge is developed. In the scope of the model, the pathway lengths of the secondary electrons in the pre-sheath region are calculated by analytical integration of the Lorentz differential equations. Weighting these lengths by using the distribution law of the mean free path of the secondary electrons, we estimate the densities of the ionizing events over the cathode and the relative flux of the sputtered atoms. The expression so deduced correlates for the first time the erosion depth profile of the target with the angle theta. The model shows reasonably good fittings to the experimental target erosion depth profiles confirming that ionization occurs mainly in the pre-sheath zone.
Resumo:
In the last decades, the value of research on neurological patients’ quality of life (QOL) has become unquestionable. In this context, most studies focus on the relationship between patients’ QOL and their sociodemographic and/or clinical and/or modifiable psychosocial characteristics. They give us information regarding the sociodemographic and clinical profile most prone to low QOL reports and also on ways to improve patients’ QOL (e.g., targeting their selfesteem). Nevertheless, little is known about the role nonmodifiable psychosocial variables can have on patients’ QOL perception. Consequently, the aim of the present study is to explore the relationship between QOL and personality in neurological patients.
Resumo:
A imagem de perfusão do miocárdio por tomografia computorizada de emissão de fotão único (SPECT, do acrónimo inglês Single Photon Emission Computed Tomography) é um dos exames complementares de diagnóstico mais indicados na cardiologia clínica. Os dois agentes tecneciados mais utilizados são o 99mTc-tetrofosmina e o 99mTc-sestamibi. Estes permitem avaliar a distribuição do fluxo sanguíneo no músculo cardíaco. O mecanismo de fixação é idêntico nos dois radiofármacos (RF’s). São excretados, do organismo, a partir do sistema hepatobiliar para o duodeno e para o intestino. Assim, o RF está presente tanto no coração como nos órgãos adjacentes. O coração encontra-se localizado sobre o diafragma, logo acima do lobo esquerdo do fígado e nas proximidades do estômago. Deste modo, os fotões difusos provenientes desses órgãos podem interferir com a interpretação das imagens SPECT, principalmente na parede inferior do ventrículo esquerdo, traduzindo-se na redução da razão alvo-fundo e na qualidade da imagem. Deste modo, a sensibilidade e a especificidade da Cintigrafia de Perfusão do Miocárdio (CPM) diminuem. Têm sido descritos na literatura vários métodos e técnicas para minimizar o efeito da actividade extra-miocárdica, como: a aquisição de imagens mais tardias, a ingestão de líquidos ou alimentos ricos em lípidos. Outras técnicas apontam para a alteração do posicionamento do paciente durante a aquisição. Assim, o objectivo deste estudo é identificar o protocolo da CPM a nível nacional e avaliar a percentagem de repetições de exames provocadas pela interferência de actividade extra-miocárdica.
Resumo:
Globalmente, o vírus do papiloma humano (HPV) é a segunda causa mais comum de cancro associado a mortalidade e morbilidade entre as mulheres devido ao seu relacionamento com o cancro do colo do útero (CCU) e caracteriza-se também como uma das doenças sexualmente transmissíveis (DST) mais prevalentes. Entre 2000 e 2006, foram diagnosticados cerca de 1.401.400 casos de CCU e estima-se que seja responsável por cerca de 260.000 mortes anuais. Aproximadamente 80% destas mortes ocorrem nos países em desenvolvimento. Um estudo Americano indicou que cerca de 30% a 40% das mulheres entre os 14 e 40 anos encontram-se infectadas pelo HPV e cerca de 75% foi infectada em alguma altura da sua vida. Estudos mostram que este vírus é também responsável por um razoável numero de casos de cancro da vulva, vagina, ânus, pénis, orofaríngeos e pulmonares. Com um número estimado de mais de 200 diferentes estirpes, este vírus é maioritariamente assintomático. Existem 13 a 18 tipos diferentes de HPV considerados de elevado risco oncogénico (HPV-ERO) responsáveis pela maioria dos casos de cancro. As estirpes consideradas de baixo risco oncogénico (HPV-BRO) estão intimamente relacionadas com riscos clínicos menores como lesões (e.g., verrugas) na mucosa oral, genital, anal e laríngea. Recentemente, o avançado conhecimento molecular da estrutura do HPV permitiu aos investigadores o desenvolvimento de medidas preventivas e de tratamento face ao vírus, incluindo a introdução de uma vacina no mercado aprovada pela FDA muito eficiente especialmente nas mulheres mais jovens.
Resumo:
Medicamento genérico (MG) é definido como uma fiel imitação de um medicamento original, terapeuticamente equivalente apresentando a mesma forma farmacêutica, composição qualitativa e quantitativa destinado a ser intercambiável com o produto original. Os MGs só podem ser comercializados depois de todas as patentes e certificados complementares de protecção (SPCs) que cobrem o produto original terem expirado. O papel dos MGs tem sido providenciar medicamentos essenciais que são de boa qualidade e de preço acessível em toda a União Europeia e o seu uso aumentou a acessibilidade dos pacientes e proporcionou uma poupança económica significativa para os sistemas de saúde. À medida que as despesas totais em cuidados de saúde têm vindo a aumentar e a maioria dessas despesas é composta de custos fixos (nomeadamente os serviços hospitalares), a indústria farmacêutica tem sido um objectivo de poupança em todos os países da Europa, que têm reformulado os seus sistemas nacionais de saúde de modo a responder ao rápido crescimento dos gastos em saúde. Os governos preocupados com o aumento do custo de produtos farmacêuticos dentro dos seus orçamentos nacionais de saúde, estão a esforçar-se para promover a utilização de genéricos em relação aos produtos originais de preço mais elevado. Portugal e Estónia são dois países pertencentes à União Europeia. Existem algumas diferenças no sector da saúde entre os dois países, especialmente no que concerne a medicamentos, seus preços e reembolso pelos sistemas de seguro obrigatório de saúde e serviços nacionais de saúde, no entanto apresentam em comum a preocupação com o custo dos medicamentos, incentivando o uso de MGs. Actualmente a Estónia apresenta uma quota de mercado de MGs superior a Portugal, que ocupa uma posição inferior à média Europeia. À medida que os sistemas governamentais vão incentivando o uso de MGs e o seu consumo vai aumentando é importante perceber as opiniões que os consumidores têm acerca destes medicamentos. Este estudo teve como objectivo avaliar a aceitação e as crenças dos utentes sobre MGs em relação aos medicamentos de marca (MM), comparando resultados entre Portugal e Estónia.