12 resultados para Prostate -Diseases
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
In this work, 14 primary schools of Lisbon city, Portugal, followed a questionnaire of the ISAAC - International Study of Asthma and Allergies in Childhood Program, in 2009/2010. The questionnaire contained questions to identify children with respiratory diseases (wheeze, asthma and rhinitis). Total particulate matter (TPM) was passively collected inside two classrooms of each of 14 primary schools. Two types of filter matrices were used to collect TPM: Millipore (IsoporeTM) polycarbonate and quartz. Three campaigns were selected for the measurement of TPM: Spring, Autumn and Winter. The highest difference between the two types of filters is that the mass of collected particles was higher in quartz filters than in polycarbonate filters, even if their correlation is excellent. The highest TPM depositions occurred between October 2009 and March 2010, when related with rhinitis proportion. Rhinitis was found to be related to TPM when the data were grouped seasonally and averaged for all the schools. For the data of 2006/2007, the seasonal variation was found to be related to outdoor particle deposition (below 10 μm).
Resumo:
Quando aplicada no âmbito da Anatomia Patológica, a imuno-histoquímica tem constituído um poderoso meio de identificação/caracterização de várias estruturas histológicas, permitindo delinear prognóstico e terapêutica para várias patologias. Tendo em conta que as amostras histológicas analisadas podem ser conservadas ao longo de vários anos, interessa avaliar a manutenção da antigenicidade ao longo do tempo, de forma a garantir a qualidade final da técnica quando aplicada em material de arquivo. Assim, o principal objetivo deste trabalho foi comparar a imunorreatividade do material histológico arquivado durante um, quatro e sete anos. Foi utilizado material histológico de próstata, pulmão e mama, no qual se procedeu à imunomarcação de citoqueratinas (Clones AE1/AE3), CD34 e proteína p63, por método de multímero/HRP no sistema Ventana BenchMark Ultra®. Foi realizado um ensaio com recuperação antigênica por alta temperatura (RAAT) e outro sem esta etapa. As imunomarcações (n=162) foram classificadas por três avaliadores independentes num escore quantitativo final (escala 0-100). O par média/desvio-padrão do escore final para os casos com sete anos foi de 69,06/19,05, para os casos com quatro anos foi de 66,47/20,73 e para os casos com um ano foi de 69,08/19,35, não se tendo encontrado diferenças estatisticamente significativas. Os casos sem RAAT obtiveram um par média/desvio-padrão de 54,90/17,00, enquanto os casos com RAAT obtiveram 81,50/11,60, o que revelou diferenças estatisticamente significativas (p=0,000). Para os casos em estudo conclui-se que o fator “tempo de arquivo” não está associado a alterações da imunorreatividade. A importância da RAAT na obtenção de imunomarcação de qualidade sai fortemente realçada. ABSTRACT - When applied within the framework of Pathology, immunohistochemistry has been a powerful means of identification/characterization of various histological structures, allowing to outline prognosis and therapy for various diseases. Given that the analyzed histological samples can be preserved for several years, it is interesting to assess the retention of antigenicity over time in order to ensure the quality of the final technique, when applied to stored material. Thus, the main objective of this study was to compare the immunoreactivity of the histological material archived for one, four and seven years. It was used histological material from prostate, lung and breast, in which it was performed the immunostaining of cytokeratins (clones AE1/AE3), CD34 and p63 protein by the method of multimer/HRP system on a Ventana BenchMark Ultra®. It was conducted a test with heat induced epitope retrieval (HIER) and another one without this step. The stained slides (n=162) were classified by three independent assessors using a quantitative score (scale 0-100). The pair mean/standard deviation of the score for cases with seven years was 69,06/19,05, for cases with four years was 66,47/20,73 and for cases with one year was 69,08/19,35, which did not revealed any statistically significant differences. The cases without HIER had a couple mean/standard deviation of 54.90/17.00 while the cases with HIER obtained 81.50/11.60, which revealed statistically significant differences (p=0.000). For this case study it was concluded that the factor archive period is not associated with changes in immunoreactivity. The importance of HIER in obtaining high quality immunostaining comes out strongly highlighted.
Resumo:
Since last decade, the debate on the parameter which reflects prostate cancer sensitivity to fractionation in a radiotherapy treatment, the α/β, has become extensive. Unlike most tumors, the low labeling indices (LI) and large potential doubling time that characterize the prostate tumor led some authors to consider that it may behave as a late responding tissue. So far, the existing studies with regard to this subject point to a low value of α/β, around 2.7 Gy, which may be considered as a therapeutic gain in relation to surrounding normal tissues by using fewer and larger fractions. The aim of this paper is to review several estimates that have been made in the last few years regarding the prostate cancer α/β both from clinical and experimental data, as well as the set of factors that have potentially influenced these evaluations.
Resumo:
Purpose/Objective: The purpose of this work was to determine biologically equivalent alternative regimens for the treatment of prostate cancer using External Beam Radiotherapy (EBRT) and Low Dose-Rate Brachytherapy (LDRBT) with 125I implants and to evaluate the sensitivity of these regimens to different sets of radiobiological parameters of the Linear-Quadratic (LQ) model.
The use of non-standard CT conversion ramps for Monte Carlo verification of 6 MV prostate IMRT plans
Resumo:
Monte Carlo (MC) dose calculation algorithms have been widely used to verify the accuracy of intensity-modulated radiotherapy (IMRT) dose distributions computed by conventional algorithms due to the ability to precisely account for the effects of tissue inhomogeneities and multileaf collimator characteristics. Both algorithms present, however, a particular difference in terms of dose calculation and report. Whereas dose from conventional methods is traditionally computed and reported as the water-equivalent dose (Dw), MC dose algorithms calculate and report dose to medium (Dm). In order to compare consistently both methods, the conversion of MC Dm into Dw is therefore necessary. This study aims to assess the effect of applying the conversion of MC-based Dm distributions to Dw for prostate IMRT plans generated for 6 MV photon beams. MC phantoms were created from the patient CT images using three different ramps to convert CT numbers into material and mass density: a conventional four material ramp (CTCREATE) and two simplified CT conversion ramps: (1) air and water with variable densities and (2) air and water with unit density. MC simulations were performed using the BEAMnrc code for the treatment head simulation and the DOSXYZnrc code for the patient dose calculation. The conversion of Dm to Dw by scaling with the stopping power ratios of water to medium was also performed in a post-MC calculation process. The comparison of MC dose distributions calculated in conventional and simplified (water with variable densities) phantoms showed that the effect of material composition on dose-volume histograms (DVH) was less than 1% for soft tissue and about 2.5% near and inside bone structures. The effect of material density on DVH was less than 1% for all tissues through the comparison of MC distributions performed in the two simplified phantoms considering water. Additionally, MC dose distributions were compared with the predictions from an Eclipse treatment planning system (TPS), which employed a pencil beam convolution (PBC) algorithm with Modified Batho Power Law heterogeneity correction. Eclipse PBC and MC calculations (conventional and simplified phantoms) agreed well (<1%) for soft tissues. For femoral heads, differences up to 3% were observed between the DVH for Eclipse PBC and MC calculated in conventional phantoms. The use of the CT conversion ramp of water with variable densities for MC simulations showed no dose discrepancies (0.5%) with the PBC algorithm. Moreover, converting Dm to Dw using mass stopping power ratios resulted in a significant shift (up to 6%) in the DVH for the femoral heads compared to the Eclipse PBC one. Our results show that, for prostate IMRT plans delivered with 6 MV photon beams, no conversion of MC dose from medium to water using stopping power ratio is needed. In contrast, MC dose calculations using water with variable density may be a simple way to solve the problem found using the dose conversion method based on the stopping power ratio.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Área de especialização: Terapia com Radiações
Resumo:
Radiotherapy is one of the therapeutics selected for localized prostate cancer, in cases where the tumour is confined to the prostate, penetrates the prostatic capsule or has reached the seminal vesicles (T1 to T3 stages). The radiation therapy can be administered through various modalities, being historically used the 3D conformal radiotherapy (3DCRT). Other modality of radiation administration is the intensity modulated radiotherapy (IMRT), that allows an increase of the total dose through modulation of the treatment beams, enabling a reduction in toxicity. One way to administer IMRT is through helical tomotherapy (TH). With this study we intent to analyze the advantages of helical tomotherapy when compared with 3DCRT, by evaluating the doses in the organs at risk (OAR) and planning target volumes (PTV).
Resumo:
Intensity Modulated Radiotherapy (IMRT) is a technique introduced to shape more precisely the dose distributions to the tumour, providing a higher dose escalation in the volume to irradiate and simultaneously decreasing the dose in the organs at risk which consequently reduces the treatment toxicity. This technique is widely used in prostate and head and neck (H&N) tumours. Given the complexity and the use of high doses in this technique it’s necessary to ensure as a safe and secure administration of the treatment, through the use of quality control programmes for IMRT. The purpose of this study was to evaluate statistically the quality control measurements that are made for the IMRT plans in prostate and H&N patients, before the beginning of the treatment, analysing their variations, the percentage of rejected and repeated measurements, the average, standard deviations and the proportion relations.
Resumo:
Aim - To use Monte Carlo (MC) together with voxel phantoms to analyze the tissue heterogeneity effect in the dose distributions and equivalent uniform dose (EUD) for (125)I prostate implants. Background - Dose distribution calculations in low dose-rate brachytherapy are based on the dose deposition around a single source in a water phantom. This formalism does not take into account tissue heterogeneities, interseed attenuation, or finite patient dimensions effects. Tissue composition is especially important due to the photoelectric effect. Materials and Methods - The computed tomographies (CT) of two patients with prostate cancer were used to create voxel phantoms for the MC simulations. An elemental composition and density were assigned to each structure. Densities of the prostate, vesicles, rectum and bladder were determined through the CT electronic densities of 100 patients. The same simulations were performed considering the same phantom as pure water. Results were compared via dose-volume histograms and EUD for the prostate and rectum. Results - The mean absorbed doses presented deviations of 3.3-4.0% for the prostate and of 2.3-4.9% for the rectum, when comparing calculations in water with calculations in the heterogeneous phantom. In the calculations in water, the prostate D 90 was overestimated by 2.8-3.9% and the rectum D 0.1cc resulted in dose differences of 6-8%. The EUD resulted in an overestimation of 3.5-3.7% for the prostate and of 7.7-8.3% for the rectum. Conclusions - The deposited dose was consistently overestimated for the simulation in water. In order to increase the accuracy in the determination of dose distributions, especially around the rectum, the introduction of the model-based algorithms is recommended.
Resumo:
The MCNPX code was used to calculate the TG-43U1 recommended parameters in water and prostate tissue in order to quantify the dosimetric impact in 30 patients treated with (125)I prostate implants when replacing the TG-43U1 formalism parameters calculated in water by a prostate-like medium in the planning system (PS) and to evaluate the uncertainties associated with Monte Carlo (MC) calculations. The prostate density was obtained from the CT of 100 patients with prostate cancer. The deviations between our results for water and the TG-43U1 consensus dataset values were -2.6% for prostate V100, -13.0% for V150, and -5.8% for D90; -2.0% for rectum V100, and -5.1% for D0.1; -5.0% for urethra D10, and -5.1% for D30. The same differences between our water and prostate results were all under 0.3%. Uncertainties estimations were up to 2.9% for the gL(r) function, 13.4% for the F(r,θ) function and 7.0% for Λ, mainly due to seed geometry uncertainties. Uncertainties in extracting the TG-43U1 parameters in the MC simulations as well as in the literature comparison are of the same order of magnitude as the differences between dose distributions computed for water and prostate-like medium. The selection of the parameters for the PS should be done carefully, as it may considerably affect the dose distributions. The seeds internal geometry uncertainties are a major limiting factor in the MC parameters deduction.
Resumo:
Backgound - In developed countries people are living longer and the incidence of chronic disease is increasing. Chronic disease and its treatments can have a negative impact on sexual functioning and sexual satisfaction. Aim of study - To explore and to compare sexual function and sexual satisfaction in people with stable chronic diseases.
Resumo:
Since the first in vivo studies of cerebral function with radionuclides by Ingvar and Lassen, nuclear medicine (NM) brain applications have evolved dramatically, with marked improvements in both methods and tracers. Consequently it is now possible to assess not only cerebral blood flow and energy metabolism but also neurotransmission. Planar functional imaging was soon substituted by single-photon emission computed tomography (SPECT) and positron emission tomography (PET); it now has limited application in brain imaging, being reserved for the assessment of brain death.