6 resultados para Project 2002-004-B : Noise Management in Urban Environments
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
The aim of this study was to contribute to the assessment of exposure levels of ultrafine particles in the urban environment of Lisbon, Portugal, due to automobile traffic, by monitoring lung deposited alveolar surface area (resulting from exposure to ultrafine particles) in a major avenue leading to the town center during late spring, as well as in indoor buildings facing it. Data revealed differentiated patterns for week days and weekends, consistent with PM2.5 and PM10 patterns currently monitored by air quality stations in Lisbon. The observed ultrafine particulate levels may be directly correlated with fluxes in automobile traffic. During a typical week, amounts of ultrafine particles per alveolar deposited surface area varied between 35 and 89.2 μm2/cm3, which are comparable with levels reported for other towns in Germany and the United States. The measured values allowed for determination of the number of ultrafine particles per cubic centimeter, which are comparable to levels reported for Madrid and Brisbane. In what concerns outdoor/indoor levels, we observed higher levels (32 to 63%) outdoors, which is somewhat lower than levels observed in houses in Ontario.
Resumo:
The aim of this study was to contribute to the assessment of exposure levels of ultrafine particles in the urban environment of Lisbon, Portugal, due to automobile traffic, by monitoring lung deposited alveolar surface area (resulting from exposure to ultrafine particles) in a major avenue leading to the town center during late spring, as well as in indoor buildings facing it. Data revealed differentiated patterns for week days and weekends, consistent with PM2.5 and PM10 patterns currently monitored by air quality stations in Lisbon. The observed ultrafine particulate levels may be directly correlated with fluxes in automobile traffic. During a typical week, amounts of ultrafine particles per alveolar deposited surface area varied between 35 and 89.2 mu m2/cm3, which are comparable with levels reported for other towns in Germany and the United States. The measured values allowed for determination of the number of ultrafine particles per cubic centimeter, which are comparable to levels reported for Madrid and Brisbane. In what concerns outdoor/indoor levels, we observed higher levels (32 to 63%) outdoors, which is somewhat lower than levels observed in houses in Ontario.
Resumo:
In this paper, a novel mixed-integer nonlinear approach is proposed to solve the short-term hydro scheduling problem in the day-ahead electricity market, considering not only head-dependency, but also start/stop of units, discontinuous operating regions and discharge ramping constraints. Results from a case study based on one of the main Portuguese cascaded hydro energy systems are presented, showing that the proposedmixed-integer nonlinear approach is proficient. Conclusions are duly drawn. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
The investigation which employed the action research method (qualitative analysis)was divided into four fases. In phases 1-3 the participants were six double bass students at Nossa Senhora do Cabo Music School. Pilot exercises in creativity were followed by broader and more ambitious projects. In phase 4 the techniques were tested and amplified during a summer course for twelve double bass students at Santa Cecilia College.
Resumo:
The Tagus estuary is bordered by the largest metropolitan area in Portugal, the Lisbon capital city council. It has suffered the impact of several major tsunamis in the past, as shown by a recent revision of the catalogue of tsunamis that struck the Portuguese coast over the past two millennia. Hence, the exposure of populations and infrastructure established along the riverfront comprises a critical concern for the civil protection services. The main objectives of this work are to determine critical inundation areas in Lisbon and to quantify the associated severity through a simple index derived from the local maximum of momentum flux per unit mass and width. The employed methodology is based on the mathematical modelling of a tsunami propagating along the estuary, resembling the one occurred on the 1 November of 1755 that followed the 8.5 M-w Great Lisbon Earthquake. The employed simulation tool was STAV-2D, a shallow-flow solver coupled with conservation equations for fine solid phases, and now featuring the novelty of discrete Lagrangian tracking of large debris. Different sets of initial conditions were studied, combining distinct tidal, atmospheric and fluvial scenarios, so that the civil protection services were provided with comprehensive information to devise public warning and alert systems and post-event mitigation intervention. For the most severe scenario, the obtained results have shown a maximum inundation extent of 1.29 km at the AlcA cent ntara valley and water depths reaching nearly 10 m across Lisbon's riverfront.
Resumo:
The concerns on metals in urban wastewater treatment plants (WWTPs) are mainly related to its contents in discharges to environment, namely in the final effluent and in the sludge produced. In the near future, more restrictive limits will be imposed to final effluents, due to the recent guidelines of the European Water Framework Directive (EUWFD). Concerning the sludge, at least seven metals (Cd, Cr, Cu, Hg, Ni, Pb and Zn) have been regulated in different countries, four of which were classified by EUWFD as priority substances and two of which were also classified as hazardous substances. Although WWTPs are not designed to remove metals, the study of metals behaviour in these systems is a crucial issue to develop predictive models that can help more effectively the regulation of pre-treatment requirements and contribute to optimize the systems to get more acceptable metal concentrations in its discharges. Relevant data have been published in the literature in recent decades concerning the occurrence/fate/behaviour of metals in WWTPs. However, the information is dispersed and not standardized in terms of parameters for comparing results. This work provides a critical review on this issue through a careful systematization, in tables and graphs, of the results reported in the literature, which allows its comparison and so its analysis, in order to conclude about the state of the art in this field. A summary of the main consensus, divergences and constraints found, as well as some recommendations, is presented as conclusions, aiming to contribute to a more concerted action of future research. © 2015, Islamic Azad University (IAU).