46 resultados para Primary level
em Repositório Científico do Instituto Politécnico de Lisboa - Portugal
Resumo:
Introduction: Standard Uptake Value (SUV) is a measurement of the uptake in a tumour normalized on the basis of a distribution volume and is used to quantify 18F-Fluorodeoxiglucose (FDG) uptake in tumors, such as primary lung tumor. Several sources of error can affect its accuracy. Normalization can be based on body weight, body surface area (BSA) and lean body mass (LBM). The aim of this study is to compare the influence of 3 normalization volumes in the calculation of SUV: body weight (SUVW), BSA (SUVBSA) and LBM (SUVLBM), with and without glucose correction, in patients with known primary lung tumor. The correlation between SUV and weight, height, blood glucose level, injected activity and time between injection and image acquisition is evaluated. Methods: Sample included 30 subjects (8 female and 22 male) with primary lung tumor, with clinical indication for 18F-FDG Positron Emission Tomography (PET). Images were acquired on a Siemens Biography according to the department’s protocol. Maximum pixel SUVW was obtained for abnormal uptake focus through semiautomatic VOI with Quantification 3D isocontour (threshold 2.5). The concentration of radioactivity (kBq/ml) was obtained from SUVW, SUVBSA, SUVLBM and the glucose corrected SUV were mathematically obtained. Results: Statistically significant differences between SUVW, SUVBSA and SUVLBM and between SUVWgluc, SUVBSAgluc and SUVLBMgluc were observed (p=0.000<0.05). The blood glucose level showed significant positive correlations with SUVW (r=0.371; p=0.043) and SUVLBM (r=0.389; p=0.034). SUVBSA showed independence of variations with the blood glucose level. Conclusion: The measurement of a radiopharmaceutical tumor uptake normalized on the basis of different distribution volumes is still variable. Further investigation on this subject is recommended.
Resumo:
Of vital importance to the successful implementation of the teaching of FLs in the 1st Cycle...
Resumo:
A biomonitoring study, using transplanted lichens Flavoparmelia caperata, was conducted to assess the indoor air quality in primary schools in urban (Lisbon) and rural (Ponte de Sor) Portuguese sites. The lichens exposure period occurred between April and June 2010 and two types of environments of the primary schools were studied: classrooms and outdoor/courtyard. Afterwards, the lichen samples were processed and analyzed by instrumental neutron activation analysis (INAA) to assess a total of 20 chemical elements. Accumulated elements in the exposed lichens were assessed and enrichment factors (EF) were determined. Indoor and outdoor biomonitoring results were compared to evaluate how biomonitors (as lichens) react at indoor environments and to assess the type of pollutants that are prevalent in those environments.
Resumo:
In this work, 14 primary schools of Lisbon city, Portugal, followed a questionnaire of the ISAAC - International Study of Asthma and Allergies in Childhood Program, in 2009/2010. The questionnaire contained questions to identify children with respiratory diseases (wheeze, asthma and rhinitis). Total particulate matter (TPM) was passively collected inside two classrooms of each of 14 primary schools. Two types of filter matrices were used to collect TPM: Millipore (IsoporeTM) polycarbonate and quartz. Three campaigns were selected for the measurement of TPM: Spring, Autumn and Winter. The highest difference between the two types of filters is that the mass of collected particles was higher in quartz filters than in polycarbonate filters, even if their correlation is excellent. The highest TPM depositions occurred between October 2009 and March 2010, when related with rhinitis proportion. Rhinitis was found to be related to TPM when the data were grouped seasonally and averaged for all the schools. For the data of 2006/2007, the seasonal variation was found to be related to outdoor particle deposition (below 10 μm).
Resumo:
Clean air is a basic requirement of life. The Indoor Air Quality (IAQ) has been the object of several studies due to an increasing concern within the scientific community on the effects of indoor air quality upon health, especially as people tend to spend more time indoors than outdoors. The quality of air inside homes, offices, schools or other private and public buildings is an essential determinant of healthy life and people’s well-being. People can be exposed to contaminants by inhalation, ingestion and dermal contact. In the past, scientists have paid much attention to the study of exposure to outdoor air contaminants, because they have realised the seriousness of outdoor air pollution problems. However, each indoor microenvironment has unique characteristics, determined by the local outdoor air, specific building characteristics and indoor activities. Indeed, hazardous substances are emitted from buildings, construction materials and indoor equipment or due to human activities indoors.
Resumo:
O sector dos edifícios é responsável por uma percentagem significativa dos consumos de energia primária e de energia eléctrica em Portugal, associada principalmente ao conforto térmico dos seus ocupantes. A União Europeia pretende uma redução de 20%, até 2020, dos consumos de energia e consequentes emissões de CO2 através da melhoria da eficiência energética dos edifícios públicos e residenciais. Em Portugal, o Plano Nacional para a Eficiência Energética (PNAEE) tem por objectivo obter uma poupança anual de energia de pelo menos 1% até ao ano de 2016, tomando como base a média de consumos de energia final, registados entre 2001 e 2005. Neste contexto, os edifícios anteriores a 1990 (primeira versão do RCCTE) podem apresentar um potencial significativo de melhoria da sua eficiência energética com base na sua reabilitação. Os edifícios “Gaioleiros” (1880 – 1930) constituindo uma parte importante do património histórico da cidade de Lisboa, para os quais a informação sobre o seu desempenho térmico é limitada, considerou-se pertinente efectuar um estudo destinado à sua caracterização experimental e numérica, face à especificidade do comportamento térmico das suas paredes caracterizadas pela elevada espessura. No presente trabalho, apresenta-se a metodologia e os resultados experimentais da medição da resistência térmica das paredes e da medição das necessidades térmicas de aquecimento da habitação. Estes resultados experimentais foram utilizados na validação do modelo de simulação térmica da habitação, que posteriormente serviu para avaliar as suas necessidades térmicas de aquecimento (Nic) e de arrefecimento (Nvc), identificar oportunidades de melhoria e avaliar o respectivo potencial de reabilitação. Neste trabalho, como contributos para uma reabilitação sustentável, apresentam-se avaliações de oportunidades de melhoria com base em estratégias de reforço do isolamento térmico. Dos resultados obtidos concluiu-se que melhorando o isolamento térmico das paredes e vãos envidraçados é possível baixar consideravelmente os consumos de energia associados à habitação, cumprindo assim as exigências estabelecidas no RCCTE ao nível dos requisitos de qualidade térmica da envolvente e consumos energéticos para edifícios novos e grandes reabilitações.
Resumo:
The devastating impact of the Sumatra tsunami of 26 December 2004, raised the question for scientists of how to forecast a tsunami threat. In 2005, the IOC-UNESCO XXIII assembly decided to implement a global tsunami warning system to cover the regions that were not yet protected, namely the Indian Ocean, the Caribbean and the North East Atlantic, the Mediterranean and connected seas (the NEAM region). Within NEAM, the Gulf of Cadiz is the more sensitive area, with an important record of devastating historical events. The objective of this paper is to present a preliminary design for a reliable tsunami detection network for the Gulf of Cadiz, based on a network of sea-level observatories. The tsunamigenic potential of this region has been revised in order to define the active tectonic structures. Tsunami hydrodynamic modeling and GIS technology have been used to identify the appropriate locations for the minimum number of sea-level stations. Results show that 3 tsunameters are required as the minimum number of stations necessary to assure an acceptable protection to the large coastal population in the Gulf of Cadiz. In addition, 29 tide gauge stations could be necessary to fully assess the effects of a tsunami along the affected coasts of Portugal, Spain and Morocco.
Resumo:
Desde há alguns anos que têm vindo a ser mobilizados esforços para a elaboração de uma regulamentação técnica unificada aplicável a nível Europeu, os Eurocódigos Estruturais, a qual visa estabelecer uma harmonização da regulamentação a utilizar na construção civil, promovendo a eliminação de anteriores barreiras técnicas. Actualmente, no âmbito Nacional, encontramo-nos numa fase de transição da regulamentação técnica em vigor para o dimensionamento de Edifícios em Betão Armado, do Regulamento de Segurança e Acções para Estruturas de Betão Armado (RSA) e Regulamento de Estruturas de Betão Armado e Pré-Esforçado (REBAP) para os Eurocódigos Estruturais, sendo que neste período de transição se verifica a coexistência de ambos devido à ainda não publicação em Diário da República da nova regulamentação a adoptar. No presente trabalho procura-se verificar a segurança da estrutura de um edifício com laje fungiforme, situado em Faro, projectado segundo a regulamentação nacional em vigor (RSA/REBAP), através da aplicação dos Eurocódigos Estruturais, nomeadamente o EC0, EC1, EC2 e EC8. Este tipo de edifícios, em que a laje fungiforme é utilizada como elemento sísmico primário, não é totalmente abordada no EC8, a verificação de segurança será então efectuada considerando duas abordagens de análise distintas. Numa primeira abordagem de análise adopta-se a estrutura como sendo da Classe de Ductilidade Baixa (DCL) considerando todos os elementos como sísmicos primários, e numa segunda abordagem de análise assume-se uma maior ductilidade da estrutura (DCM) classificando alguns elementos como sísmicos secundários.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Intervenção Cardiovascular.
Resumo:
This study explores a large set of OC and EC measurements in PM(10) and PM(2.5) aerosol samples, undertaken with a long term constant analytical methodology, to evaluate the capability of the OC/EC minimum ratio to represent the ratio between the OC and EC aerosol components resulting from fossil fuel combustion (OC(ff)/EC(ff)). The data set covers a wide geographical area in Europe, but with a particular focus upon Portugal, Spain and the United Kingdom, and includes a great variety of sites: urban (background, kerbside and tunnel), industrial, rural and remote. The highest minimum ratios were found in samples from remote and rural sites. Urban background sites have shown spatially and temporally consistent minimum ratios, of around 1.0 for PM(10) and 0.7 for PM(2.5).The consistency of results has suggested that the method could be used as a tool to derive the ratio between OC and EC from fossil fuel combustion and consequently to differentiate OC from primary and secondary sources. To explore this capability, OC and EC measurements were performed in a busy roadway tunnel in central Lisbon. The OC/EC ratio, which reflected the composition of vehicle combustion emissions, was in the range of 03-0.4. Ratios of OC/EC in roadside increment air (roadside minus urban background) in Birmingham, UK also lie within the range 03-0.4. Additional measurements were performed under heavy traffic conditions at two double kerbside sites located in the centre of Lisbon and Madrid. The OC/EC minimum ratios observed at both sites were found to be between those of the tunnel and those of urban background air, suggesting that minimum values commonly obtained for this parameter in open urban atmospheres over-predict the direct emissions of OC(ff) from road transport. Possible reasons for this discrepancy are explored. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Projeto de Intervenção apresentado à Escola Superior de Educação de Lisboa para obtenção do grau de Mestre em Didática da Língua Portuguesa no 1.º e 2.º Ciclo do Ensino Básico
Resumo:
Dissertação apresentada à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Ciências da Educação, especialidade Educação Especial – Problemas Cognitivos e Multideficiência
Resumo:
Projeto de Intervenção apresentado à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Ciências da Educação - Especialidade Educação Especial
Resumo:
Introdução - A prevalência da doença pulmonar obstrutiva crónica (DPOC) apresenta valores muito heterogéneos em todo o mundo. A iniciativa Burden of Obstructive Lung Disease (BOLD) foi desenvolvida para que a prevalência da DPOC possa ser avaliada com metodologia uniformizada. O objetivo deste estudo foi estimar a prevalência da DPOC em adultos com 40 ou mais anos numa população alvo de 2 700 000 habitantes na região de Lisboa, de acordo com o protocolo BOLD. Métodos - A amostra foi estratificada de forma aleatória multifaseada selecionando-se 12 freguesias. O inquérito compreendia um questionário com informação sobre fatores de risco para a DPOC e doença respiratória autoreportada; adicionalmente, foi efetuada espirometria com prova de broncodilatação. Resultados - Foram incluídos 710 participantes com questionário e espirometria aceitáveis. A prevalência estimada da DPOC na população no estadio GOLD I+ foi de 14,2% (IC 95%: 11,1; 18,1) e de 7,3% no estadio ii+ (IC 95%: 4,7; 11,3). A prevalência não ajustada foi de 20,2% (IC 95%: 17,4; 23,3) no estadio i+ e de 9,5% (IC 95%: 7,6; 11,9) no estadio ii+. A prevalência da DPOC no estadio GOLD II+ aumentou com a idade, sendo mais elevada no sexo masculino. A prevalência estimada da DPOC no estadio GOLD I+ foi de 9,2% (IC 95%: 5,9; 14,0) nos não fumadores versus 27,4% (IC 95%: 18,5; 38,5) nos fumadores com carga tabágica de ≥ 20 Unidades Maço Ano. Detetou-se uma fraca concordância entre a referência a diagnóstico médico prévio e o diagnóstico espirométrico, com 86,8% de subdiagnósticos. Conclusões - O achado de uma prevalência estimada da DPOC de 14,2% sugere que esta é uma doença comum na região de Lisboa, contudo com uma elevada proporção de subdiagnósticos. Estes dados apontam para a necessidade de aumentar o grau de conhecimento dos profissionais de saúde sobre a DPOC, bem como a necessidade de maior utilização da espirometria nos cuidados de saúde primários.
Resumo:
Mestrado em Contabilidade e Gestão das Instituições Financeiras